Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFUELING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Advanced space transportation technologies

A wide range of propulsion technologies for space transportation are discussed in the literature. It is clear from the literature review that a single propulsion technology cannot satisfy the many mission needs in space. Many of the technologies tested, proposed, or in experimental stages relate to: chemical and nuclear fuel; radiative and corpuscular external energy source; tethers; cannons; and electromagnetic acceleration. The scope and limitation of these technologies is well tabulated in the literature. Prior experience has shown that an extensive amount of fuel needs to be carried along for the return mission. This requirement puts additional constraints on the lift off rocket technology and limits the payload capacity. Consider the possibility of refueling in space. If the return fuel supply is guaranteed, it will not only be possible to lift off more payload but also to provide security and safety of the mission. Exploration to deep space where solar sails and thermal effects fade would also be possible. Refueling would also facilitate travel on the planet of exploration. This aspect of space transportation prompts the present investigation. The particle emissions from the Sun's corona will be collected under three different conditions: in space closer to the Sun, in the Van Allen Belts; and on the Moon. It is proposed to convert the particle state into gaseous, liquid, or solid state and store it for refueling space vehicles. These facilities may be called space pump stations and the fuel collected as space fuel. Preliminary estimates of fuel collection at all three sites will be made. Future work will continue towards advancing the art of collection rate and design schemes for pumping stations.

Raj, Rishi S.↗

A Practical, Affordable Cryogenic Propellant Depot Based on ULA's Flight Experience

Mankind is embarking on the next step in the journey of human exploration. We are returning to the moon and eventually moving to Mars and beyond. The current Exploration architecture seeks a balance between the need for a robust infrastructure on the lunar surface, and the performance limitations of Ares I and V. The ability to refuel or top-off propellant tanks from orbital propellant depots offers NASA the opportunity to cost effectively and reliably satisfy these opposing requirements. The ability to cache large orbital quantities of propellant is also an enabling capability for missions to Mars and beyond. This paper describes an option for a propellant depot that enables orbital refueling supporting Exploration, national security, science and other space endeavors. This proposed concept is launched using a single EELV medium class rocket and thus does not require any orbital assembly. The propellant depot provides cryogenic propellant storage that utilizes flight proven technologies augmented with technologies currently under development. The propellant depot system, propellant management, flight experience, and key technologies are also discussed. Options for refueling the propellant depot along with an overview of Exploration architecture impacts are also presented.

Kutter, Bernard F.↗

Conduit Coating Abrasion Testing

During my summer internship at NASA I have been working alongside the team members of the RESTORE project. Engineers working on the RESTORE project are creating ·a device that can go into space and service satellites that no longer work due to gas shortage or other technical difficulties. In order to complete the task of refueling the satellite a hose needs to be used and covered with a material that can withstand effects of space. The conduit coating abrasion test will help the researchers figure out what type of thermal coating to use on the hose that will be refueling the satellites. The objective of the project is to determine whether or not the conduit coating will withstand the effects of space. For the RESTORE project I will help with various aspects of the testing that needed to be done in order to determine which type of conduit should be used for refueling the satellite. During my time on the project I will be assisting with wiring a relay board that connected to the test set up by soldering, configuring wires and testing for continuity. Prior to the testing I will work on creating the testing site and help write the procedure for the test. The testing will take place over a span of two weeks and lead to an informative conclusion. Working alongside various RESTORE team members I will assist with the project's documentation and records. All in all, throughout my internship at NASA I hope to learn a number of valuable skills and be a part of a hard working team of engineers.

Sullivan, Mary K.↗

Restore-L Intern Final Report

Every year, approximately 20 satellites are retired because their propellants are exhausted. Primarily limited by fuel, the satellites are usually fully functioning otherwise. The lifetimes of satellites can be extended with the capability of refueling. Not only would refueling extend satellite lifetime, it would also provide future satellites flexibility to prioritize other elements of their missions. Restore-L is a Goddard Space Flight Center Satellite Servicing Projects Division mission with the primary objectives of developing tools, technologies, and techniques to extend the lifetime of satellites - even if they were not designed to be serviced in or- bit. Equipped with five key servicing technology elements, the Restore-L Servicing Vehicle will demonstrate industry-changing satellite servicing technologies. The primary goal of the Restore-L mission is to rendezvous with, grasp, refuel, and relocate a government-owned satellite to extend its lifetime. The Propellant Transfer Subsystem (PTS) is required to deliver measured amounts of fuel to the client satellite in a safe manner.

Negi, Abhay↗

How the Allocation of Lander Functions Impacts Human Lunar Exploration Architecture Propellant Demands

As NASA looks to the moon as a proving ground for the technologies required to conduct the first human exploration campaign of Mars, this study assesses the potential propellant demands that a sustained human lunar presence would require. In particular, this study evaluates how the allocation and distribution of vehicle functions to a different number of vehicles can impact the propellant required to conduct a human lunar exploration mission. Four different transportation architectures for human lunar exploration and three different refueling assumptions were defined. The impact on the propellant required for a mission was assessed for all architectures and refueling assumptions for ranges of crew payload mass, vehicle inert mass fraction, and a sensitivity to the mission maneuver velocity magnitudes. The results of this analysis show that aggregating vehicle functions to a single-stage lander vehicle can have a positive impact on the architecture's level of vehicle reusability and that an increase in the number of refueling opportunities reduces the mass of the vehicles and of the propellant required per mission.

Matteo A. Clark↗

Gateway at the Crossroads of Sustainable Lunar Exploration

The Gateway Program has made substantial design and development progress toward delivering a small, human-tended lunar space station purposefully designed to enable sustainable human exploration. The Program integrates partners and providers organizationally and physically as part of the spacecraft. The Power and Propulsion Element (PPE) and the Habitation and Logistics Outpost (HALO) with the European System Providing Refueling, Infrastructure and Telecommunications (ESPRIT) HALO Lunar Communications System (HLCS) have begun manufacturing the long lead components and will be launched first as a Co-Manifested Vehicle (CMV). The International Habitat (I-Hab) and ESPRIT Refueling Module (ERM) are passing life cycle milestones and include capabilities key for human crewmembers, such as windows, private sleeping quarters, and galley functions. The Logistics Module (LM) may provide a variety of services to Gateway depending on each mission. Requirements for the airlock have been developed, including requests that it support the integrated spacecraft with functions like augmenting heat rejection capabilities, and interfaces with new spacesuits will soon be developed in more detail. As a critical element of the architecture for solar system exploration, Gateway implements key tenets and features of international interoperability standards necessary to operate with multiple visiting vehicles and lunar assets, especially avionics, communications, and docking. Specific choices such as software architecture and standards, power standards, and robotics standards make it possible to utilize heritage or proprietary technology, yet still operate as one spacecraft. Engineering teams are evaluating many possible future missions to be executed at or utilizing the Gateway. The system architecture protects for an evolvable, extensible, and flexible capability. Designing systems robust enough to serve as a cornerstone of exploration activities for decades while remaining adaptable is not without its challenges. The detailed integration activities have revealed challenges and the need to mature key technologies. Refueling is a key component of achieving long life for Gateway, with unique operations to plan, safety concerns to mitigate, and risk reduction activities to conduct to better understand the system. The constraints and impacts of the design of visiting vehicles is also an important concern, with orientation constraints, control of attitude and orbit of the Gateway with docked visiting vehicles. Tradeoffs between robust maintainable systems and lightweight, compact systems must be balanced. Opportunities still exist for adding additional advanced capabilities to increase and extend Gateway’s benefits, such as intravehicular robotics, autonomous Guidance Navigation and Control (GN&C), and augmented control propulsion, heat rejection, or other services.

Molly S Anderson↗

Gateway at the Crossroads of Sustainable Lunar Exploration

The Gateway Program has made substantial design and development progress toward delivering a small, human-tended lunar space station purposefully designed to enable sustainable human exploration. The Program integrates partners and providers organizationally and physically as part of the spacecraft. The Power and Propulsion Element (PPE) and the Habitation and Logistics Outpost (HALO) with the European System Providing Refueling, Infrastructure and Telecommunications (ESPRIT) HALO Lunar Communications System (HLCS) have begun manufacturing the long lead components and will be launched first as a Co-Manifested Vehicle (CMV). The International Habitat (I-Hab) and ESPRIT Refueling Module (ERM) are passing life cycle milestones and include capabilities key for human crewmembers, such as windows, private sleeping quarters, and galley functions. The Logistics Module (LM) may provide a variety of services to Gateway depending on each mission. Requirements for the airlock have been developed, including requests that it support the integrated spacecraft with functions like augmenting heat rejection capabilities, and interfaces with new spacesuits will soon be developed in more detail. As a critical element of the architecture for solar system exploration, Gateway implements key tenets and features of international interoperability standards necessary to operate with multiple visiting vehicles and lunar assets, especially avionics, communications, and docking. Specific choices such as software architecture and standards, power standards, and robotics standards make it possible to utilize heritage or proprietary technology, yet still operate as one spacecraft. Engineering teams are evaluating many possible future missions to be executed at or utilizing the Gateway. The system architecture protects for an evolvable, extensible, and flexible capability. Designing systems robust enough to serve as a cornerstone of exploration activities for decades while remaining adaptable is not without its challenges. The detailed integration activities have revealed challenges and the need to mature key technologies. Refueling is a key component of achieving long life for Gateway, with unique operations to plan, safety concerns to mitigate, and risk reduction activities to conduct to better understand the system. The constraints and impacts of the design of visiting vehicles is also an important concern, with orientation constraints, control of attitude and orbit of the Gateway with docked visiting vehicles. Tradeoffs between robust maintainable systems and lightweight, compact systems must be balanced. Opportunities still exist for adding additional advanced capabilities to increase and extend Gateway’s benefits, such as intravehicular robotics, autonomous Guidance Navigation and Control (GN&C), and augmented control propulsion, heat rejection, or other services.

Molly S Anderson↗

Modeling Low-G Slosh Using Negative Mass

The modeling of the behavior of fluids in low- or microgravity is a field with little validated data but of great interest to space agencies and companies in the face of humanity’s expanding presence beyond low Earth orbit. Efforts to refuel and repair satellites in geostationary orbit require an understanding of the behavior of sloshing fuel in microgravity. The stability of remote sensing equipment and satellites depends on robust fluid slosh dampening or very accurate modeling, and the Artemis program includes the refueling of large landing systems in its architecture. However, current methodologies are quite binary: either use a relatively low-accuracy equivalent mechanical model or use computational fluid dynamics which are not practical for onboard systems due to their relatively high computational cost. In this work, a novel method of tracking the bubble rather than tracking the fuel itself is presented. Computational fluid dynamics simulations are used to validate the model based on available experimental data, and the dynamics of a refueler spacecraft based on Gateway’s Logistics Module are simulated both for the sloshing case and without sloshing considered.

Matthew M. Wittal↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flexible Grid-Based Electrolysis Hydrogen Production for Fuel Cell Vehicles Reduces Costs and Greenhouse Gas Emissions

Hydrogen fuel cell electric vehicles (FCEVs) have been proposed as an option for lowering carbon dioxide (CO 2 ) and pollutants emissions from the transportation sector, when implemented in combination with green hydrogen production methods such as water electrolysis powered by renewable electricity. FCEVs also have the added advantages of high specific energy density and rapid refueling, two important challenges that battery electric vehicles have not yet fully overcome. Moreover, flexible operation of electrolysis could support the grid and lower electricity costs. In this paper, we simulate time-varying FCEV hydrogen refueling demand for light, medium- and heavy-duty vehicles met using electrolysis systems distributed throughout the Western U.S. power system. We find that by oversizing electrolyzers the resulting load flexibility results in different hydrogen generation temporal profiles, average electricity costs, renewable curtailment levels, and CO2 emissions. Our results indicate that increasing hydrogen production flexibility lowers hydrogen and electricity generation cost and CO 2 emissions, but there is a tradeoff between lowering operational cost and increasing electrolyzer capital cost, yielding a minimum total system cost at a size corresponding to between 80% and 90% annual capacity factor assuming a future electrolyzer cost of $300/kW.

25 ENERGY STORAGE↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a separate effects MiniFuel irradiation experiment investigating microstructure evolution in high burnup UO 2

The microstructural evolution of UO 2 fuel pellets during commercial operation in light water reactors (LWRs) is known to vary significantly across the pellet radius due to spatial variations in local temperature and burnup. The primary obstacle to extending LWR refueling cycles to 24-month intervals is the susceptibility of certain high burnup fuel microstructures to fuel fragmentation, relocation, and dispersal (FFRD) during a loss of coolant accident (LOCA). Although FFRD of the high burnup structure in the rim region of a pellet is well studied, the fine fragmentation that has been observed in a second region, near the midradius of the pellet (termed the “dark zone”) following mock LOCA testing of high burnup commercial fuel rods is less understood. This paper describes the design, analysis, and execution of a separate effects MiniFuel irradiation experiment that aims to identify the specific temperature and burnup regimes under which FFRD-susceptible dark zone microstructures form. The small disc specimens (3 mm diameter by ∼0.3 mm thick) enable more precise control of the relatively uniform temperature and burnup conditions. A total of 42 specimens were fabricated with typical LWR fuel densities (∼96%–98% of theoretical density) and grain sizes (∼12 μm) and are being irradiated over a range of temperatures (600°C–1000°C) and discharge burnups (50–72 MWd/kg-U) that bound the midradius region of high burnup LWR fuel. Fuel specimens with identical 235 U enrichments were inserted in two irradiation locations in the High Flux Isotope Reactor and are currently undergoing irradiation to further evaluate the impact of rate effects (fission rate, time at temperature) on the microstructural evolution. The fuel fabrication and the thermal and neutronic simulations used for designing the experiment are detailed in this paper. A secondary objective of the experiment is to observe fission gas release (FGR) under the various irradiation conditions, and this work provides first-order predictions of FGR from all fuel specimens. The insights gained from these experiments will inform future high burnup core designs that could minimize the formation of susceptible microstructures and ultimately enable 24-month refueling cycles while minimizing the fraction of the fuel susceptible to FFRD.

FFRD↗

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗

An On-Demand Electric Transit Case Study of New Rochelle, New York

Here, this article characterizes the performance and ridership patterns of an on-demand transit (ODT) service utilizing lightweight electric vehicles (EVs) in New Rochelle, New York. Ridership sociodemographics, travel patterns (both temporal and spatiotemporal), and energy use from the service were explored using travel and survey data from September 2019 through December 2023. The ODT service was found to be used more by women (nearly 60%) and younger demographics (>65% under the age of 42), with peak use in the middle of the day and a grocery store as a top origin and destination. The service was utilized primarily for short trips (86% under 2 mi), with approximately one-third of riders using the ODT service to connect to a train or bus. The costs associated with fueling/charging were compared for different types of fleet vehicles, and the small, right-sized EVs were found to have annual charging costs that were roughly half of the refueling costs for conventional hybrid vans, and 24 times lower than a fleet of diesel buses. Evaluating the vehicle fleet and mapping current socio-spatial travel demand can inform system performance, guide service area development, and support future planning such as expansion to nearby communities and transit hubs. The findings in this case study suggest that on-demand electric transit may be a significant and growing space for advancing highly valued public mobility services. Public transport interventions that consider right-sized, electric, on-demand vehicles can help improve mobility access and reduce energy use and refueling costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗