Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDUAL GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

HD gas purification for polarized HDice targets production at Jefferson Lab

Solid, frozen-spin targets of molecular HD were rst developed for nuclear physics by a collaboration between Syracuse University and Brookhaven National Lab. They have been successfully used in measurements with photon beams, rst at the Laser-Electron-Gamma-Source [1] and most recently at Je erson Lab during the running of the E06-101 (g14) experiment [2]. Preparations are underway to utilize the targets in future electron experiments after the completion of the 12 GeV JLab upgrade [3]. HD is an attractive target since all of the material is polarizable, of low Z, and requires only modest holding elds. At the same time, the small contributions from the target cell can be subtracted from direct measurements. Reaching the frozen-spin state with both high polarization and a signi cant spin relaxation time requires careful control of H2 and D2 impurities. Commercially available HD contains 0.5 - 2% concentrations of H2 and D2. Low-temperature distillation is required to reduce these concentrations to the 104 level to enable useful target production. This distillation is done using a column lled with heli-pack C [4] to give good separation e ciency. Approximately 12 moles of commercial HD is condensed into the mechanically refrigerated system at the base temperature of 11K. The system is then isolated and the temperature stabilized at 18K producing liquid HD, which is boiled by a resistive heater. The circulation established by the boil-o condensing throughout the column then ltering back down produces a steady-state isotopic separation permitting the extraction of HD gas with very low H2 and D2 content. A residual gas analyzer initially monitors distillation. Once the H2 concentration falls below its useful operating range, samples are periodically collected for analysis using gas chromatography [5] and Raman scattering. Where the measurement techniques overlap, good agreement is obtained. The operation of the distillery and results of gas analysis will be discussed. References [1] Phy. Rev. Lett. 101 (2009) 172002. [2] www.jlab.org/exp_prog/proposals/06/PR-06-101.pdf [3] www.jlab.org/exp_prog/proposals/12/PR12-12-009.pdf, www.jlab.org/exp_prog/proposals/12/PR12-12-010.pdf, and www.jlab.org/exp_prog/proposals/11/PR12-11-111.pdf [4] Nucl. Inst. Meth. 664 (2012) 347, www.wilmad-labglass.com/Products/LG-6730-104/ [5] Rev. Sci. Instrum. 82, 024101 (2011).

Whisnant, Charles↗

Water and Ammonia Desorption from 5A Zeolite

The objective of this project is to demonstrate the adsorption and desorption characteristics of water and ammonia on 5A zeolite during regeneration conditions. As discussed in literature, zeolite material is a crystalline hydrated aluminosilicate material. Zeolites have high cation exchange ability and are commonly used as adsorbents in separation and purification processes. The property of uniformly sized pores allows zeolites to selectively separate gases. Because they have varying ion selectivity, there is competitive adsorption in a multicomponent mixture. 5A zeolite has a uniform pore diameter of 5 Angstroms. Water and ammonia are miscible components with similar molecular weights and size. This makes distinguishing the two compounds difficult using mass spectrometry. In a previous study, it was shown that water tends to desorb from 5A zeolite from 40 deg. C to 353 deg. C with peaks at 177 deg. C and 244 deg. C, while ammonia tends to desorb from 300 deg. C to 580 deg. C with a peak at 436 deg. C as determined using a Micromeritics AutoChem 2920 Instrument. The one drawback of using a Micromeritics Instrument is that only a few milligrams of sample material can be used. Bench scale tests can better demonstrate desorption characteristics of water and ammonia during regeneration from 5A zeolite material. Water in argon carrier gas and ammonia in hydrogen carrier gas will be tested separately, then a mixture of the two will be tested. Initial bake-out conditions: hydrogen carrier gas, slowly raise temp to approximately 450 deg. C until desired moisture content <100 ppm is achieved. Water loading: argon carrier gas through bubbler until breach is observed using the residual gas analyzer (RGA). Ammonia loading: hydrogen carrier gas through system until breach is observed using RGA. Regeneration conditions: hydrogen carrier gas, raise temp to approximately 300 deg. C, then slowly to 450 deg. C. Observe signals on RGA. Weigh samples between tests and integrate RGA signals. Accomplishments: Developed work control documentation and completed safety related requirements; Flow sheet and test system development; Initial bake-out of first sample. Testing will determine if regenerating zeolite material can be safely accomplished by high-temperature bake-out to remove ammonia. If unsuccessful, ammonia would only be removed at the end of life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Simulations for Ion-Production and Back-Bombardment in GaAs Photo-guns

GaAs-based DC high voltage photo-guns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. Specifically, the operating lifetime is dominated by ion back-bombardment of the photocathode from ionized residual gas. While numerous experiments have been performed to characterize the operating lifetime under various conditions, detailed simulations of the ion back-bombardment mechanism that explains these experiments are lacking. Recently, a new user routine was implemented using the code General Particle Tracer (GPT) to simulate electron impact ionization of residual beam line gas and simultaneously track the incident electron, the ejected electron, and the newly formed ion. This new routine was benchmarked against analytical calculations and then applied to experiments performed at the CEBAF injector at the Thomas Jefferson National Accelerator Facility to study the effectiveness of limiting ions from entering the cathode-anode gap using a positively biased anode. These simulations were performed using detailed 3D field maps produced with CST Microwave Studio describing the photo-gun electrostatics. Discussion of the experiment and the application of this new GPT routine to model the experiments will be presented at the workshop.

Yoskowitz, Joshua↗

Impact-induced devolatilization and hydrogen isotopic fractionation of serpentine: Implications for planetary accretion

Impact-induced devolatilization of porous serpentine was investigated using two independent experimental methods, the gas recovery and the solid recovery method, each yielding nearly identical results. For shock pressures near incipient devolatilization, the hydrogen isotopic composition of the evolved H2O is very close to that of the starting material. For shock pressures at which up to 12 percent impact-induced devolatilization occurs, the bulk evolved gas is significantly lower in deuterium than the starting material. There is also significant reduction of H2O to H2 in gases recovered at these higher shock pressures, probably caused by reaction of evolved H2O with the metal gas recovery fixture. Gaseous H2O-H2 isotopic fractionation suggests high temperature isotopic equilibrium between the gaseous species, indicating initiation of devolatilization at sites of greater than average energy deposition. Bulk gas-residual solid isotopic fractionations indicate nonequilibrium, kinetic control of gas-solid isotopic ratios. Impact-induced hydrogen isotopic fractionation of hydrous silicates during accretion can strongly affect the long-term planetary isotopic ratios of planetary bodies, leaving the interiors enriched in deuterium. Depending on the model used for extrapolation of the isotopic fractionation to devolatilization fractions greater than those investigated experimentally can result from this process.

Tyburczy, James A.↗

A Study of Single Pass Ion Effects at the ALS

We report the results of experiments on a 'fast beam-ion instability' at the Advanced Light Source (ALS). This ion instability, which can arise even when the ions are not trapped over multiple beam passages, will likely be important for many future accelerators. In our experiments, we filled the ALS storage ring with helium gas, raising the pressure approximately two orders of magnitude above the nominal pressure. With gaps in the bunch train large enough to avoid conventional (multi-turn) ion trapping, we observed a factor of 2-3 increase in the vertical beam size along with coherent beam oscillations which increased along the bunch train. Ion trapping has long been recognized as a potential limitation in electron storage rings. The ions, generated by beam-gas collisions, become trapped in the negative potential of the beam and accumulate over multiple beam passages. The trapped ions are then observed to cause a number of deleterious effects such as an increasing beam phase space, a broadening and shifting of the beam transverse oscillation frequencies (tunes), collective beam instabilities, and beam lifetime reductions. All of these effects are of concern for the next generation of accelerators, such as the B-factories or damping rings for future linear colliders, which will store high beam currents with closely spaced bunches and ultra-low beam emittances. One of the standard solutions used to prevent ion trapping is to include a gap in the bunch train which is long compared to the bunch spacing. In this case, the ions are first strongly-focused by the passing electron bunches and then over-focused in the gap. With a sufficiently large gap, the ions can be driven to large amplitudes where they form a diffuse halo and do not affect the beam. In this paper, we describe experiments that study a new regime of transient ion instabilities predicted to arise in future electron storage rings, and linacs with bunch trains. These future rings and linacs, which will be operated with higher beam currents, small transverse beam emittances, and long bunch trains, will use ion clearing gaps to prevent conventional ion trapping. But, while the ion clearing gap may suppress the conventional ion instabilities, it will not suppress a transient beam-ion instability where ions generated and trapped during the passage of a single train lead to a fast instability. While both conventional and transient ion instabilities have the same origin, namely ions produced by the beam, they have different manifestations and, more importantly, the new transient instability can arise even after the conventional ion instability is cured. This new instability is called the 'Fast Beam-Ion Instability' (FBII). In many future rings, the FBII is predicted to have very fast growth rates, much faster than the damping rates of existing and proposed transverse feedback systems, and thus is a potential limitation. To study the FBII, we performed experiments at the ALS, a 1.5 GeV electron storage ring. At the nominal ALS pressure of about 0.24 nTorr, the FBII is not evident. To study the instability, we intentionally added helium gas to the storage-ring vacuum system until the residual gas pressure was increased about 80 nTorr. This brought the predicted growth rate of the instability at least an order of magnitude above the growth rate of conventional multibunch instabilities driven by the RF cavities and above the damping rate of the transverse feedback system (TFB) in the ALS and, thereby, established conditions very similar to those in a future storage ring. We then filled the ring with a relatively short train of bunches, suppressing conventional ion instabilities. In the following, we will first briefly describe This paper describes the experiment and results in more detail.

43 PARTICLE ACCELERATORS↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Polycrystalline silicon on tungsten substrates

Thin films of electron-beam-vaporized silicon were deposited on fine-grained tungsten substrates under a pressure of about 1 x 10 to the -10th torr. Mass spectra from a quadrupole residual-gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. During separate silicon depositions, the atomically clean substrates were maintained at various temperatures between 400 and 780 C, and deposition rates were between 20 and 630 A min. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry before and after cleaning, deposition, and annealing. Auger depth profiling, X-ray analysis, and SEM in the topographic and channeling modes were utilized to characterize the samples with respect to silicon-metal interface, interdiffusion, silicide formation, and grain size of silicon. The onset of silicide formation was found to occur at approximately 625 C. Above this temperature tungsten silicides were formed at a rate faster than the silicon deposition. Fine-grain silicon films were obtained at lower temperatures.

Bevolo, A. J.↗

Efficient solar cells by space processing

Thin films of electron beam evaporated silicon were deposited on molybdenum, tantalum, tungsten and molybdenum disilicide under ultrahigh vacuum conditions. Mass spectra from a quadrapole residual gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry. The presence of phosphorus in the silicon was responsible for attaining elevated temperatures with silicide formations. Heteroepitaxial silicon growth was sensitive to the presence of oxygen during deposition, the rate and length of deposition as well as the substrate orientation.

Schmidt, F. A.↗

Carbothermal Reduction Demonstration (CaRD) Gas Analysis Subsystem Development

The Carbothermal Reduction Demonstration (CaRD) project is currently developing a subscale system to demonstrate the operation and performance of the carbothermal reduction process and quantify the production of molar equivalent oxygen (carbon monoxide (CO) and carbon dioxide (CO2)). Traditionally, gas chromatography (GC) systems are utilized to qualify gases due to their ability to separate the volatile compounds within the gas mixture, followed by quantification of the isolated component of interest. Despite these capabilities, GCs require consumables for their operational mobile phase and consequently are not often considered a flight-forward option. An alternative analytical technique known as mass spectrometry measures the presentence of gas phase molecules based on their mass-to-charge ratio. Residual gas analyzers (RGAs) which utilize mass spectrometry are not traditionally used to quantify analytes, but proper design and calibrations can result in a flight-forward analytical instrument capable of direct quantification of volatile gases of interest. Kennedy Space Center's role for the project is to design a gas analyzer system to detect and quantify the CO and CO2 gas produced during the carbothermal reaction utilizing a commercial version of the Mass Spectrometer Observing Lunar Operations (MSolo) instrument. MSolo is a modified commercial off-the-shelf mass spectrometer which consists of quadrupole mass filter and space rated electronics. MSolo is currently a TRL 6 technology and manifested on the PRIME-1 and VIPER missions. This paper describes leveraging MSolo based instrumentation to develop a gas analysis system for the work outlined in the 2023 International Conference on Environmental Systems (ICES) paper number 313. The design and testing of the brassboard phase of the project will be described along with the current work underway which will cover the design and preliminary test results of the prototype phase.

Ryan Patrick Gott↗

A laser-wire beam-energy and beam-profile monitor at the BNL linac

In 2009 a beam-energy monitor was installed in the high energy beam transport (HEBT) line at the Brookhaven National Lab linac. This device measures the energies of electrons stripped from the 40mA H{sup -} beam by background gas. Electrons are stripped by the 2.0x10{sup -7}torr residual gas at a rate of {approx}1.5x10{sup -8}/cm. Since beam electrons have the same velocities as beam protons, the beam proton energy is deduced by multiplying the electron energy by m{sub p}/m{sub e}=1836. A 183.6MeV H{sup -} beam produces 100keV electrons. In 2010 we installed an optics plates containing a laser and scanning optics to add beam-profile measurement capability via photodetachment. Our 100mJ/pulse, Q-switched laser neutralizes 70% of the beam during its 10ns pulse. This paper describes the upgrades to the detector and gives profile and energy measurements.

43 PARTICLE ACCELERATORS↗

Beam Lifetime and Emittance Growth in RHIC under Normal Operating Conditions, with the Hydrogen Gas Jet, the Cluster-Jet and Pellet targets

The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions’ influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the “vacuum capture”. The beam lifetime is presented as an exponential decay where the loss rate of the beam particles is given by: $\frac{1}{\tau} = \frac{1}{N} \frac{dN}{dt} = n l f (\sigma_N + \sigma_C)$, where $f$ is the revolution frequency, $l$ is the path of the projectiles (the circumference of RHIC is equal to C = 3833.845 m).

43 PARTICLE ACCELERATORS↗

Beam lifetime and emittance growth in RHIC under normal operating conditions with the hydrogen gas jet, the cluster-jet and pellet targets

The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the 'vacuum capture'.

08 HYDROGEN↗

Correlation of chemical composition and electrical properties of rf sputtered alumina films

Alumina films were prepared by radio frequency magnetron sputtering from an aluminum oxide target on an indium tin oxide covered glass. The purpose of the study was to test the influence of the sputter parameters on the elemental composition, surface morphology, and electrical insulation properties (breakdown fields and leakage currents). Tested parameters were the sputter gas (Ar) pressure, the sputter rate, the sputter power, the sputter gas composition (Ar:O{sub 2}), the conditioning of the target, the residual base pressure, and the substrate temperature. The surface morphology of the films was investigated by atomic force microscopy. Depth profiles of the elemental compositions were measured by elastic recoil detection using energetic heavy ions, and the insulation properties were investigated by current voltage measurements and impedance spectroscopy. The main finding is that the leakage currents increase by about five orders of magnitude, if the atomic ratio of O:Al increases from 1.35 to 2.0. In parallel the breakdown fields decrease by a factor of 100, and the character of the breakdowns changes from soft to hard. The highest breakdown fields (2.4 MV/cm) and smallest leakage currents (6.5x10{sup -8} A/cm{sup 2} at 2.0 MV/cm) are obtained for slightly Al rich films with small atomic concentrations of H (<0.5 at. %). These films were sputtered in pure Ar and under the lowest possible pressure of the residual gas.

36 MATERIALS SCIENCE↗

Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Insulation-Testing Cryostat With Lifting Mechanism

The figure depicts selected aspects of an apparatus for testing thermal-insulation materials for cryogenic systems at temperatures and under vacuum or atmospheric conditions representative of those encountered in use. This apparatus, called "Cryostat-100," is based on the established cryogen-boil-off calorimeter method, according to which the amount of heat that passes through an insulation specimen to a cryogenic fluid in a container, and thus the effective thermal conductance of the specimen, is taken to be proportional to the amount of the cryogenic fluid that boils off from the container. The design of Cryostat-100 is based partly on, and incorporates improvements over, the design of a similar prior apparatus called "Cryostat-1" described in "Improved Methods of Testing Cryogenic Insulation Materials" (KSC-12107 & KSC- 12108), NASA Tech Briefs, Vol. 24, No. 12 (December 2000), page 46. The design of Cryostat-100 also incorporates the best features of two other similar prior apparatuses called "Cryostat-2" (also described in the cited prior article) and "Cryostat- 4." Notable among the improvements in Cryostat-100 is the addition of a lifting mechanism that enables safe, rapid, reliable insertion and removal of insulation specimens and facilitates maintenance operations that involve lifting. As in Cryostat-1, the cold mass is a vertical stainless-steel cylindrical vessel subdivided into a larger measurement vessel with smaller thermal-guard vessels at both ends. During operation, all three vessels are kept filled with liquid nitrogen near saturation at ambient pressure (temperature .77.4 K). The cold mass of Cryostat-100 has a length of 1 m and diameter of 168 mm. Each specimen has a corresponding nominal length and inner diameter and a nominal thickness of 25.4 mm. Specimens that are shorter and have thicknesses between 0 and 50 mm are also acceptable. Bulk-fill, foam, clam-shell, multilayer insulation, and layered materials can be tested over a very wide range of thermal transmission: apparent thermal conductivity from 0.01 to 60 mW/m-K and heat flux from 0.1 to 500 W/sq m. A test in Cryostat-100 can be conducted at any desired gas pressure between ambient atmospheric pressure at one extreme and a vacuum with residual pressure <10(exp -5) torr (<1.33 10(exp -3) Pa) at the other extreme. The residual gas (and purge gas) is typically nitrogen, but can be any suitable purge gas (e.g., helium, argon, or carbon dioxide). Usually, the temperature on the warm boundary of the insulation specimen is maintained near the ambient value (approximately 293 K), while the boiling of liquid nitrogen at atmospheric pressure in the cold mass maintains the temperature on the cold boundary of the specimen at approximately 77 K.

Fesmire, James↗

Effect of Vacuum Conditioning on the Bremsstrahlung Dose Rates at the NSLS-II Beamlines

Gas bremsstrahlung is produced by the interaction of the storage ring electron beam with residual gas molecules in the storage ring vacuum chamber. Such interactions are one of the sources of stored beam loss, result in beam decay, and occur continuously during the storage ring operation. Gas bremsstrahlung interactions take place all around the storage ring, but are a particular problem in the straight sections for the insertion devices. Bremsstrahlung produced as a narrow beam, sums up for the entire straight path in the line of sight of the insertion device beamlines and comes down through the beamlines along with the synchrotron radiation. The NSLS-II straight beam path in the line of sight for the insertion device beamlines is ~16 m in length. This poses a radiological safety issue at the beamlines.

36 MATERIALS SCIENCE↗

Outgassing of Flown and Unflown MIR Solar Cells

A solar panel array with more than ten years space exposure was removed from the Mir core module in November 1997, and an eight panel section was returned to Earth in January 1998. Several solar cells were removed from panel eight of the returned array and placed in a high vacuum system with a residual gas analyzer (200 amu mass spectrometer) and a cold finger. Similar unflown solar cells of the same vintage were later obtained from Energia. Several of the unflown cells were also placed in the vacuum system and outgassed residues were collected on the LN2 cold finger. Almost 3 mg of outgassed residue was collected -from a string of three unflown solar cells over a period of 94 hours under vacuum. The collected residue was weighed with a microbalance, and then the residue was analyzed by FTIR spectroscopy, and by gas chromatograph-mass spectroscopy. About 25 outgassed constituents were separated by the gas chromatograph, and a high-resolution mass spectrum was obtained of each constituent. Molecular identifications have been made for the constituents. The constituents are primarily cyclic siloxanes, and several of the constituents are isomers of the same molecule. Most of the outgassed constituents have a molecular mass of about 500 amu. Almost one mg of residue was extracted from one sq cm of coverglass/adhesive from a flown solar cell by soaking in isopropyl alcohol for 30 minutes. The gas chromatograph separated about 20 constituents. The constituents are mostly cyclic siloxanes with linear branches, hydrocarbons, and phthalates. The typical molecular mass is about 600 amu. These identifications of specific outgassing molecules have resulted in a more complete understanding of the SiO(x) contamination on the Mir solar cell coverglasses, and on the MEEP experiment trays and optical specimens during the Shuttle-Mir Phase One flight experiment program. Adjusted outgassing rates based on the data reported here, and/or measured outgassing rates and specific molecular identifications of ISS hardware samples are needed to input into model predictions of induced environment effects of the ISS.

Harvey, Gale A.↗