Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

A composite electrodynamic mechanism to reconcile spatiotemporally resolved exciton transport in quantum dot superlattices

Quantum dot (QD) solids are promising optoelectronic materials; further advancing their device functionality requires understanding their energy transport mechanisms. The commonly invoked near-field Förster resonance energy transfer (FRET) theory often underestimates the exciton hopping rate in QD solids, yet no consensus exists on the underlying cause. In response, we use time-resolved ultrafast stimulated emission depletion (STED) microscopy, an ultrafast transformation of STED to spatiotemporally resolve exciton diffusion in tellurium-doped cadmium selenide–core/cadmium sulfide–shell QD superlattices. We measure the concomitant time-resolved exciton energy decay due to excitons sampling a heterogeneous energetic landscape within the superlattice. The heterogeneity is quantified by single-particle emission spectroscopy. This powerful multimodal set of observables provides sufficient constraints on a kinetic Monte Carlo simulation of exciton transport to elucidate a composite transport mechanism that includes both near-field FRET and previously neglected far-field emission/reabsorption contributions. Uncovering this mechanism offers a much-needed unified framework in which to characterize transport in QD solids and additional principles for device design.

36 MATERIALS SCIENCE↗

time-resolved spectroscopy fit (trspecfit) v0.01

Analyze 2D time- and energy-resolved data, such as from a pump-probe spectroscopy experiment. User can select and input different peak shapes/ functions and background types to first fit a ground state/ unperturbed spectrum. This would be similar to how standard spectroscopy data is fit. Subsequently, to describe the time domain, users can choose functions that describe the temporal dynamics of one or more spectral features, such as a peak amplitude, peak position, etc. These time dynamics functions can be added or convoluted (e.g. describing an instrument response function) with each other. Functionality to integrate implicit variables leading to distributions of certain parameters/ functions is in development. Alternatively, 2D data can be analyzed one time step at a time to get an idea of the time dynamics of the system before deploying the global 2D fit described above. Typically people write custom software for this purpose. During my PhD I've seen five internal LBL and external researchers write one-off code in different languages to analyze time- and energy-resolved spectra. While this was specifically was for a laser pump - X-ray probe spectroscopy experiment, I'm trying to write a general package for the time-resolved spectroscopy community.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

A Vertically Resolved MSE Framework Highlights the Role of the Boundary Layer in Convective Self-Aggregation

Abstract Convective self-aggregation refers to a phenomenon in which random convection can self-organize into large-scale clusters over an ocean surface with uniform temperature in cloud-resolving models. Previous literature studies convective aggregation primarily by analyzing vertically integrated (VI) moist static energy (MSE) variance. That is the global MSE variance, including both the local MSE variance at a given altitude and the covariance of MSE anomalies between different altitudes. Here we present a vertically resolved (VR) MSE framework that focuses on the local MSE variance to study convective self-aggregation. Using a cloud-resolving simulation, we show that the development of self-aggregation is associated with an increase of local MSE variance, and that the diabatic and adiabatic generation of the MSE variance is mainly dominated by the boundary layer (BL; the lowest 2 km). The results agree with recent numerical simulation results and the available potential energy analyses showing that the BL plays a key role in the development of self-aggregation. Additionally, we find that the lower free troposphere (2–4 km) also generates significant MSE variance in the first 15 days. We further present a detailed comparison between the global and local MSE variance frameworks in their mathematical formulation and diagnostic results, highlighting their differences.

54 ENVIRONMENTAL SCIENCES↗

Resolved Gravity Waves in the Extratropical Stratosphere: Effect of Horizontal Resolution Increase from O (10) to O (1) km

Global ECMWF IFS simulations with horizontal grid spacings of 1, 4, and 9 km are used to assess gravity wave forcing (GWF) in the extratropical stratosphere. Results with important implications for GWF parameterizations at high and intermediate resolutions are presented. A doubling in the zonal-mean resolved GWF is observed when the horizontal resolution is increased from 9 to 1 km. Small-scale gravity waves with horizontal wavelengths < 100 km dominate this increase. Over most regions, excluding the polar night jet in the Antarctic spring, the total (resolved + parameterized) GWF at 9 km (4 km) is underestimated by up to 30% (15%). This implies that the parameterization of GWF is still required at 9 and 4 km horizontal resolutions. Despite the small land area in the Southern Hemisphere (SH), the resolved orographic and nonorographic GWF contribute equally to the total GWF in the SH at 1 km resolution. This is not reflected in the partitioning of the parameterized GWF, which has a significantly larger nonorographic contribution at 9 km. As a result, a zonal-mean momentum budget analysis reveals that the total GWF contributes one-third of SH springtime polar vortex deceleration at 1 km, whereas the contribution is as much as 50% at 9 km. In conclusion, this suggests that a rebalancing of the parameterized nonorographic and orographic GWF is required.

54 ENVIRONMENTAL SCIENCES↗

A protocol and analysis of year-long simulations of global storm-resolving models and beyond

We propose a protocol to evaluate and analyze year-long simulations of global storm-resolving models (GSRMs). The proposed protocol complements an earlier 40-day simulation protocol under the DYAMOND (DYnamics of the Atmospheric general circulation Modeled On Non-hydrostatic Domains) project to allow the analysis of the seasonal cycle and associated climatic relevant phenomena. This intercomparison aims to reveal how GSRMs, which can simulate mesoscale convective systems (MCSs) in the global domain, reproduce atmospheric large-scale structures related to convection beyond month-long simulations. The intercomparison for one-year simulations is conducted by either atmosphere-only models or atmosphere–ocean coupled models with atmospheric horizontal mesh sizes less than 5 km. We recommend the continuous four seasons from March 2020 to February 2021 as a target period for the intercomparison but with options for many groups to join more flexibly. The output variables are collected at 0.25° resolution, and archives of a small set of native grid variables are encouraged to analyze tropical cyclones and MCSs. Through the proposed global storm-resolving simulation, we will evaluate the climatological distributions of the atmospheric large-scale circulations, such as the Intertropical Convergence Zone (ITCZ), monsoon, midlatitude jets, their time evolution, and the upscale impacts on them. We present sample analyses from a one-year simulation using the 3.5 km mesh Nonhydrostatic Icosahedral Atmospheric Model (NICAM), revealing the realistic zonal contrast of tropical precipitation, no double ITCZ structure, the reasonable midlatitude jet position and intensity but a weak bias of storm track activities, and a warm bias over the Eurasia during boreal winter. We also clarify the cross-scale interaction, such as the effects of cold pools on mean precipitation over the Maritime Continent through the precipitation diurnal cycle and the effects of resolved gravity waves on midlatitude mean flows. The proposed one-year simulation protocol is referred to as the “Sendai Protocol.” This protocol is not unique or definite for evaluating GSRMs; we prospect a hierarchical set of experiments from short-term to multi-year simulations as GSRM intercomparisons.

54 ENVIRONMENTAL SCIENCES↗

High fidelity blade-resolved and actuator line data from a 16 turbine wind farm simulation using ExaWind

This data was generated with the ExaWind code suite (https://github.com/Exawind) as a demonstration of a large, 16 turbine wind farm simulation, calculated using two different levels of fidelity. The lower level of fidelity approach uses an actuator line approach to represent the turbines, and was simulated with AMR-Wind (https://github.com/Exawind/amr-wind/) as the background flow solver, coupled to OpenFAST (https://github.com/OpenFAST/openfast). The higher level of fidelity simulation uses a blade-resolved approach, and is done using AMR-Wind, Nalu-Wind (https://github.com/Exawind/nalu-wind), OpenFAST, and TIOGA (https://github.com/Exawind/tioga). In the blade-resolved simulation, ExaWind couples together a background flow solver, AMR-Wind, and a near-body solver, Nalu-Wind, through an overset technique from the TIOGA application. OpenFAST handles the structural dynamics of the turbine blades and towers, which informs the fluid-structure interaction of the wind turbines with the flow solvers. In the actuator line simulation, a mesh of 295M elements was used for a 5km x 5km domain, and it was simulated using 256 nodes (2048 GPU's) on the Oak Ridge Leadership Computing Facility Frontier supercomputer. For the blade-resolved simulation, 1.5B element mesh was used in the AMR-Wind background 5km x 5km domain, and 16M elements were used for each turbine in the Nalu-Wind domains, for a total of 1.7B elements. This was simulated using 384 nodes on Frontier, with each node using 56 cores for Nalu-Wind and 8 GPU cores. The data in this archive includes the turbine outputs from OpenFAST, 2D sampling planes from AMR-Wind, and full-field solution files from AMR-Wind and Nalu-Wind.

17 WIND ENERGY↗

Spatially-resolved measurements of spin valley polarization in MOCVD-grown monolayer WSe 2

Time-resolved Kerr rotation microscopy is used to generate and measure spin valley polarization in MOCVD-grown monolayer tungsten diselenide (WSe 2 ). The Kerr signal reveals bi-exponential decay with time constants of 100 ps and 3 ns. Measurements are performed on several triangular flakes from the same growth cycle and reveal larger spin valley polarization near the edges of the flakes. This spatial dependence is observed across multiple WSe 2 flakes in the Kerr rotation measurements but not in the spatially resolved reflectivity or microphotoluminescence data. Time-resolved pump-probe overlap measurements further reveal that the Kerr signal’s spatial dependence is not due to spin diffusion on the nanosecond timescale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast Dynamics of Molecules on Surfaces Studied with Time-Resolved XUV Photoelectron Spectroscopy (Final Report)

In this project we set out to make technical advances in time-resolved photoemission from surfaces and study molecule-surface charge transfer processes. Combining a novel light source developed at Stony Brook with a new type of time-of-flight photoemission electron microscope (TOF k-mic) developed in Mainz, Germany, we achieved the former goal. Our light source, based on cavity-enhanced high harmonic generation at 61 MHz repetition rate, enables ultrafast time-resolved photoemission experiments to be conducted with orders of magnitude higher photocurrents than otherwise possible. Critically, this provides the high dynamic range necessary to study perturbatively excited samples, such that one can study the intrinsic dynamics of electrons and holes as they would occur in a device. Combining our light source with the TOF k-mic, we’ve achieved an overall improvement in data rate of time- and angle-resolved photoemission (tr-ARPES) of approximately four orders of magnitude over the previous state-of-the-art using kHz-repetition rate sources and conventional hemispherical electron analyzers. This new instrument is now being used in experiments on 2D materials and organic semiconductors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Spatially Resolved Velocity Structures in Jets of DF Tau and UY Aur A

Young stars accrete mass and angular momentum from their circumstellar disks. Some of them also drive outflows, which can be distinguished in optical forbidden emission lines. We analyze a sample of binary T Tauri stars observed with long-slit spectroscopy by the Hubble Space Telescope between 1998 and 2000, searching for spatially resolved outflows. We detect resolved [O i] emission in 2 cases out of 21. In DF Tau we resolve high- and medium-velocity outflows in a jet and counterjet out to 60 au. The outflows are accelerated within the inner 12 au and retain a constant speed thereafter. In UY Aur, we detect a blue- and a redshifted outflow from UY Aur A, as well as a blueshifted jet from UY Aur B. All of these features have been seen in [Fe ii] with data taken 10 years apart indicating that the underlying outflow pattern is stable on these timescales.

79 ASTRONOMY AND ASTROPHYSICS↗

Dissecting Nearby Galaxies with piXedfit. I. Spatially Resolved Properties of Stars, Dust, and Gas as Revealed by Panchromatic SED Fitting

We study spatially resolved properties (on spatial scales of ~1–2 kpc out to at least 3 effective radii) of the stars, dust, and gas in 10 nearby spiral galaxies. The properties of the stellar population and dust are derived by fitting the spatially resolved spectral energy distribution (SED) with more than 20 photometric bands ranging from far-ultraviolet to far-infrared. Our newly developed software piXedfit performs point-spread function matching of images, pixel binning, and models the stellar light, dust attenuation, dust emission, and emission from a dusty torus heated by an active galactic nucleus simultaneously through the energy-balance approach. With this self-consistent analysis, we present the spatially resolved version of the IRX–βrelation, finding that it is consistent with the relationship from the integrated photometry. We show that the old stellar populations contribute to the dust heating, which causes an overestimation of the star formation rate (SFR) derived from the total ultraviolet and infrared luminosities on kiloparsec scales. With archival high-resolution maps of atomic and molecular gas, we study the radial variation of the properties of the stellar populations (including stellar mass, age, metallicity, and SFR), dust (including dust mass, dust temperature, and abundance of polycyclic aromatic hydrocarbon), and gas, as well as dust-to-stellar mass and dust-to-gas mass ratios. We observe a depletion of the molecular gas mass fraction in the central region of the majority of the galaxies, suggesting that the lack of available fuel is an important factor in suppressing the specific SFR at the center.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Magnetic-Field-Component Resolvers

New resolvers for vectorially summing outputs of aircraft-mounted magnetometers are lighter and more economical to fabricate than conventional electromagnetic resolvers. One resolver is based on potentiometric principles, the second uses polarization filters, and the third has variable-capacitance elements. Optical, capacitive and potentiometric devices have applications in aircraft navigation systems.

Garner, H. D.↗

Time-resolved spectroscopy of the Mercury 6 3P1 state

The time-resolved fluorescence was observed from the Hg 6 3P1 state under the influence of the earth's magnetic field and with applied fields of up to 14 G. Modulation of the fluorescence decay signal was observed as a function of both time and space and can be interpreted in terms of a classical precession of the excited atom about the magnetic field or as quantum beats resulting from interference between coherently populated Zeeman sublevels. This modulation was studied for each of the five resolvable components of the hyperfine structure separately. The fluorescence from the even isotopes was determined to be almost completely modulated while the fluorescence from the odd isotopes was only partially modulated. The frequency of modulation of the fluorescence from the mercury-202 isotope was observed as a function of the applied magnetic field and a value for the Lande factor of 1.46 + or - 0.03 was obtained. This is within experimental error of the accepted value of 1.486. In addition, the frequency of modulation as a function of applied magnetic field was determined for each of the three resolvable components with more than one contributing isotopic hyperfine line. An investigation of the effect of radiation trapping on the degree modulation was also made.

Halstead, J. A.↗