Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

LLRF System Upgrade for the SLAC Linac

The Linac Coherent Light Source (LCLS) at SLAC is in full user operation and has met the stability goals for stable lasing. The 250pC bunch can be compressed to below 100fS before passing through an undulator. In a new mode of operation a 20pC bunch is compressed to about 10fS. Experimenters are regularly using this shorter X-ray pulse and getting pristine data. The 10fS bunch has timing jitter on the order of 100fS. Physicists are requesting that the RF system achieve better stability to reduce timing jitter. Drifts in the RF system require longitudinal feedbacks to work over large ranges and errors result in reduced performance of the LCLS. A new RF system is being designed to help diagnose and reduce jitter and drift in the SLAC linac.

43 PARTICLE ACCELERATORS↗

Contact voltage-induced softening of RF microelectromechanical system gold-on-gold contacts at cryogenic temperatures

A series of experiments were performed in vacuum environments to investigate the impact of rf micromechanical system switch contact voltage versus resistance for gold-on-gold contacts at cryogenic temperatures. The purpose of this work was twofold as follows: (1) to examine whether asperity heating models already validated for high temperature contacts were also applicable at cryogenic temperatures and (2) to explore the implications and validity of prior suggestions that contact temperatures between 338 and 373 K are high enough to dissociate adsorbed film and/or push them aside but low enough to prevent asperities from becoming soft and adherent. Measurements on two distinct switch types, fabricated at independent laboratories, were performed in the temperature range 79-293 K and for contact voltages ranging from 0.01 to 0.13 V. Contact resistance values at all temperatures were observed to be lower for higher contact voltages, consistent with the aforementioned asperity heating models, whereby increased contact currents are associated with increased heating and softening effects. In situ removal of adsorbed species by oxygen plasma cleaning resulted in switch adhesive failure. Switches that had not been cleaned meanwhile exhibited distinct reductions in resistance at contact temperatures close to 338 K, consistent with suggestions that films begin to desorb, disassociate, and/or be pushed aside at that temperature.

36 MATERIALS SCIENCE↗

Design, Fabrication and Concept for the Surface Treatment of the SRF Cavity Prototype for the CLIC Damping Rings

The Compact Linear Collider (CLIC) Damping Rings (DRs) need to generate ultra-low emittance bunches to achieve high luminosity in CLIC. This requires many wiggler magnets with big energy loss which is compensated by the Radio Frequency (RF) system. The resulting strong beam loading transients lead to a challenging design for the RF system. A novel SRF cavity at 2 GHz with an ultra-low R/Q parameter of below 1 Ω is proposed to minimize the transient beam loading effects below acceptable level. The design and fabrication of the bulk Nb prototype based on turning from a single piece of Nb and EB welding is presented. Moreover, conceptual study of the system for cavity surface treatment to achieve the highest surface magnetic field which is the main goal of the prototype cold test is described as well. To enable excellent performance in this cavity, we plan to apply the 75/120C modified low temperature bake in combination with the cold electropolishing process. This surface treatment approach has been shown to consistently deliver high accelerating gradients and improved quality factors in TESLA-shaped 1.3 GHz SRF cavities. By adapting and implementing this process for the 2 GHz ultra-low R/Q design, we aim to maximize the achievable surface magnetic field while minimizing residual resistance and field emission. This treatment strategy will be critical for demonstrating that the cavity can meet the demanding performance requirements of the CLIC damping ring RF system under high beam loading conditions.

Bafia, Daniel P. [Fermilab]↗

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

The CEBAF Master Oscillator and Distribution Remodeling

Jefferson Lab's CEBAF accelerator operation requires various frequency references to be distributed along the site. Three signals: 10 MHz, 70 MHz and 499 MHz are synthesized in the Machine Control Center (MCC) while 1427 MHz and 429 MHz are derived from 499 MHz and 70 MHz signals in four separate locations. We are replacing our obsolete 10 MHz, 70 MHz and 499 MHz sources with new sources that will incorporate a GPS receiver to discipline a 10 MHz reference. In addition the MO (Master Oscillator) system will be redundant (duplicate MO) and a third signal source will be used as a system diagnostic. Moreover, the 12 GeV Energy Upgrade for CEBAF accelerator will be adding 80 new RF systems. To support them the distribution of 1427 MHz and 70 MHz signals has to be extended and be able to deliver enough LO (Local Oscillator) and IF (Intermediate Frequency) power to 320 old and 80 new 80 RF systems. This paper discusses the new MO and the drive line extension.

43 PARTICLE ACCELERATORS↗

Diffusion Dynamics of Charged Dust Particles in Capacitively Coupled RF Discharge System

Dusty plasma is loosely defined as electron-ion plasma with additional charged components of micron-sized dust particles. In this study, we developed a particle diagnostic technique based on light scattering and particle tracking velocimetry to investigate the dynamics of micron-sized titanium oxide particles in Argon gas capacitively coupled rf-discharge. The particle trajectories are constructed from sequence of image frames and treated as sample paths of charged Brownian motion. At specific sets of plasma parameters, disordered liquid-like dust particle configuration are observed. Mean-square-displacement of the particle trajectories are determined to characterize the transport dynamics. We showed that the dust particles in disordered liquid phase exhibit anomalous diffusion with different scaling exponents for short and large time scales, indicating the presence of slow and fast modes which can be related to caging effect and dispersive transport, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Solid State Marx Modulators for Emerging Applications

Emerging linear accelerator applications increasingly push the boundaries of RF system performance and economics. The power modulator is an integral part of RF systems whose characteristics play a key role in the determining parameters such as efficiency, footprint, cost, stability, and availability. Particularly within the past decade, solid-state switch based modulators have become the standard in high-performance, high power modulators. One topology, the Marx modulator, has characteristics which make it particularly attractive for several emerging applications. This paper is an overview of the Marx topology, some recent developments, and a case study of how this architecture can be applied to a few proposed linear accelerators.

43 PARTICLE ACCELERATORS↗

Spallation Neutron Source Proton Power Upgrade Low-Level RF Control System Development

The Proton Power Upgrade (PPU) Project is approved for the Spallation Neutron Source at Oak Ridge National Laboratory and will double the proton beam power capability from 1.4 MW to 2.8 MW with 2 MW beam power available to the first target station. A second target station is planned and will utilize the remaining beam power in the future. The proton power increase will be supported with the addition of twenty-eight new superconducting cavities powered by 700 kW peak power klystrons to increase beam energy while increases to the beam current will be done with a combination of existing RF margin, and DTL HPRF upgrades. The original low-level RF control system has proven to be reliable over the past 15 years of operations, but obsolescence issues mandate a replacement system be developed for the PPU project. The replacement system is realized in a µTCA.4 platform using a combination of commercial off-the-shelf boards and custom hardware to support the requirements of PPU. This paper presents the prototype hardware, firmware, and software development activities along with preliminary testing results of the new system.

Crofford, Mark↗

Application of Non-Linear Time-Domain RF Simulations to Longitudinal Emittance Studies for the LHC

A non-linear time-domain simulation has been developed that can determine technical limitations, effects of non-linearities and imperfections, and impact of additive noise on the interaction of the beam with the Impedance Control Radio Frequency (RF) systems [1]. We present a formalism for the extraction of parameters from the time domain simulation to determine the sensitivity of the beam longitudinal emittance and dilution on the RF system characteristics. Previous studies [2], [3] have estimated the effect of a noise source on the beam characteristics assuming an independent perturbation source of the RF voltage and a simplified beam model with no coupling. We present the methodology for the time-domain simulation study of the dependence of the accelerating voltage noise spectrum on the various RF parameters and the technical properties (such as non-linearities, thermal noise, frequency response etc.) of the Low Level RF (LLRF) system components. Future plans to expand this formalism to coupled bunch studies of longitudinal emittance growth in the LHC at nominal and upgraded beam currents are briefly summarized.

43 PARTICLE ACCELERATORS↗

First SELAP Algorithm Operational Experience of the New LLRF 3.0 RF Control System

The JLAB LLRF 3.0 system has been developed and is replacing the 30-year-old LLRF systems in the CEBAF accelerator. The LLRF system builds upon 25 years of design and operational RF control experience (digital and analog), and our recent collaboration in the design of the LCLSII LLRF system. The new system also incorporates a cavity control algorithm using a fully functional phase and amplitude locked Self Exciting Loop (SELAP). The first system (controlling 8 cavities) was installed and commissioned in August of 2021. Since then the new LLRF system has been operating with cavity gradients up to 20 MV/m, and electron beam currents up to 350 uA. This paper discusses the operational experience of the LLRF 3.0 SELAP algorithm along with other software and firmware tools like cavity and klystron characterization and quench detection.

Plawski, T. E.↗

Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

43 PARTICLE ACCELERATORS↗

MLS/Airplane system design. RF component design

Results of analysis and design conducted as part of multiyear Microwave Landing System (MLS) study are reported. Design of airborne radio frequency RF MLS components was performed. MLS omnidirectional antennas are developed using microstrip technology. A remote, low-noise, radio frequency (RF) preamplifier is designed for airborne MLS installations.

Walen, D. B.↗

Flat bunch creation and acceleration: a possible path for the LHC luminosity upgrade

Increasing the collider luminosity by replacing bunches having Gaussian line-charge distribution with flat bunches, but with same beam-beam tune shift at collision, has been studied widely in recent years. But, creation of 'stable' flat bunches (and their acceleration) using a multiple harmonic RF system has not been fully explored. Here, we review our experience with long flat bunches in the barrier RF buckets at Fermilab.We presentsome preliminary results from beam dynamics simulations and recent beam studies in the LHC injectors to create stable flat bunches using double harmonic RF systems. The results deduced from these studies will be used to model the necessary scheme for luminosity upgrade in the LHC. We have also described a viable (and economical) way for creation and acceleration of flat bunches in the LHC. The flat bunch scheme may have many advantages over the LHC baseline scenario, particularly because of the reduced momentum spread of the bunch for increased intensities.

43 PARTICLE ACCELERATORS↗

Modeling RF Feedback in Elegant for Bunch-Lengthening Studies for the Advanced Photon Source Upgrade

The proposed Advanced Photon Source (APS) multibend achromat (MBA) lattice includes a passive bunchlengthening cavity to alleviate lifetime and emittance concerns. Feedback in the main radio-frequency (rf) system affects the overall impedance presented to the beam in this double rf system. To aid beam stability studies, a realistic model of rf feedback has been developed and implemented in elegant and Pelegant.

Berenc, Tim↗

NSLS-II RF Cryogenic System

The National Synchrotron Light Source II is a 3 GeV X-ray user facility commissioned in 2014. A new helium refrigerator system has been installed and commissioned to support the superconducting RF cavities in the storage ring. Special care was taken to provide very stable helium and LN2 pressures and flow rates to minimize microphonics and thermal effects at the cavities. Details of the system design along with commissioning and early operations data will be presented.

43 PARTICLE ACCELERATORS↗

Ion Emittance Growth Due to Focusing Modulation from Slipping Electron Bunch

Low energy RHIC operation has to be operated at an energy ranging from γ = 4.1 to γ = 10. The energy variation causes the change of revolution frequency. While the rf system for the circulating ion will operate at an exact harmonic of the revolution frequency (h=60 for 4.5 MHz rf and h=360 for 28 MHz rf.), the superconducting rf system for the cooling electron beam does not have a frequency tuning range that is wide enough to cover the required changes of revolution frequency. As a result, electron bunches will sit at different locations along the ion bunch from turn to turn, i.e. the slipping of the electron bunch with respect to the circulating ion bunch. At cooling section, ions see a coherent focusing force due to the electrons’ space charge, which differs from turn to turn due to the slipping. We will try to estimate how this irregular focusing affects the transverse emittance of the ion bunch.

43 PARTICLE ACCELERATORS↗