Detection of surface carbon and hydrocarbons in hot spot regions of niobium superconducting rf cavities by Raman spectroscopy
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
N/A
The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times larger than the observed HOM-driven centroid oscillation within the macropulse and is consistent with a calculated short-range wakefield effect. Additional results for kick-angle compensations will be presented.
We report the direct observations of the correlation of higher order modes (HOMs) generated by off-axis electron beam steering in TESLA-type SCRF cavities and sub-macropulse beam centroid shifts (with the concomitant effect on averaged beam size and emittance). The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a PC rf gun injecting beam into two separated 9-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. The ~100-kHz oscillations with up to 300-μm amplitudes at downstream locations were observed in a 3-MHz micropulse repetition rate beam with charges of 500 and 1000 pC/b, although the effects were much reduced at 100 pC/b. The studies were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch data, and imaging cameras viewing multi-slit images for emittance assessments at 33 MeV. Initial calculations reproduced a key feature of the phenomena. In principle, these results may be scaled to cryomodule configurations of major accelerator facilities.
Nb3Sn films are a promising alternative material for su-perconducting RF cavities, with proven high quality factors at medium fields and predictions for increased superheating field as well. In this contribution, we de-scribe the latest results from the Fermilab Nb3Sn SRF program. Early experiments have been focused on single cell 1.3 GHz cavities. We briefly review efforts to bring the parameters used in the coating process into a range where they produce uniform surfaces without regions showing signs of excess tin or thin/uncoated areas. We then present the latest cavity results, after modifications to the coating recipe based on feedback from film appear-ance and RF performance. These results show high Q0 at medium fields and a maximum field of ~18 MV/m.
aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.
Recent SRF cavities (especially 1.3 GHz elliptical cells) made of bulk Nb are approaching its theoretical limit of E acc ~ 50 MV/m (B peak ~ 200 mT). While it is important to increase the production reliability and yield of high-quality Nb SRF cavities, finding a new material that could overcome the limit of Nb technology is becoming increasingly important for SRF technology to be more attractive and open up other opportunities.
Abstract not provided.
Abstract Not Provided
Explore the source record for details and available documents.
NSLS-II storage ring currently operates with two single-cell Cornell Electron Storage Ring (CESR) type niobium cavities at 500 MHz with a Q value of 79,000 [1,2] both in one straight section in cell 24. During the maintenance period, the cavities have to be conditioned to be ready for operation. The cavities are source of bremsstrahlung radiation due to the field emission and multipacting processes.
Industrial-Scale Electron Accelerators – the Need: Energy and Environment: Waste water and sludge; In-situ applications. Industrial: In-situ cross linking at deeper penetration; Food and medical device sterilization without 60 Co; Radiation driven chemistry. Safeguards and Security: Non-invasive and stand-off inspection.
Experiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times l arger than the observed HOM-driven centroid oscillation within the macropulse, and it is consistent with a calculated short-range wakefield effect using ASTRA simulations.
This note presents measurements that support the conclusion that it is feasible to achieve magnetic field values at the level of 5 milliGauss for a cryomodule in a realistic and representative ambient magnetic field environment.
Explore the source record for details and available documents.
Overview of National Laboratory Activities on Alternative Technologies
Explore the source record for details and available documents.
Explore the source record for details and available documents.