Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Technical Progress on the Ares I-X Flight Test

Ares I-X will be NASA's first test flight for a new human-rated launch vehicle since 1981, and the team is well on its way toward completing the vehicle's design and hardware fabrication for an April 2009 launch. This uncrewed suborbital development test flight gives NASA its first opportunities to: gather critical data about the flight dynamics of the integrated launch vehicle; understand how to control its roll during flight; better characterize the stage separation environments during future flight; and demonstrate the first stage recovery system. The Ares I-X Flight Test Vehicle (FTV) incorporates a mix of flight and mockup hardware. It is powered by a four-segment solid rocket booster, and will be modified to include a fifth, spacer segment; the upper stage, Orion crew exploration vehicle, and launch abort system are simulator hardware to make the FTV aerodynamically similar to the same size, shape, and weight of Ares I. The Ares IX first stage includes an existing Shuttle solid rocket motor and thrust vector control system controlled by an Ascent Thrust Vector Controller (ATVC) designed and built by Honeywell International. The avionics system will be tested in a dedicated System Integration Laboratory located at Lockheed Martin Space Systems (LMSS) in Denver, Colorado. The Upper Stage Simulator (USS) is made up of cylindrical segments that will be stacked and integrated at Kennedy Space Center (KSC) for launch. Glenn Research Center is already building these segments, along with their internal access structures. The active Roll Control System (RoCS) includes two thruster units harvested from Peacekeeper missiles. Duty cycle testing for RoCS was conducted, and fuel tanking and detanking tests will occur at KSC in early 2008. This important flight will provide valuable experience for the ground operations team in integrating, stacking, and launching Ares I. Data from Ares I-X will ensure the safety and reliability of America's newest launch vehicle.

Davis, S.R.↗

Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

Dempsey, Paula J.↗

Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

Dempsey, Paula J.↗

Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker

The determination of radius of curvature (ROC) of optics typically uses either a phase measuring interferometer on an adjustable stage to determine the position of the ROC and the optics surface under test. Alternatively, a spherometer or a profilometer are used for this measurement. The difficulty of this approach is that for large optics, translation of the interferometer or optic under test is problematic because of the distance of translation required and the mass of the optic. Profilometry and spherometry are alternative techniques that can work, but require a profilometer or a measurement of subapertures of the optic. The proposed approach allows a measurement of the optic figure simultaneous with the full aperture radius of curvature.

Hagopian, John↗

NASA Ares I Launch Vehicle Roll and Reaction Control Systems Lessons Learned

On April 15, 2010 President Barak Obama made the official announcement that the Constellation Program, which included the Ares I launch vehicle, would be canceled. NASA s Ares I launch vehicle was being designed to launch the Orion Crew Exploration Vehicle, returning humans to the moon, Mars, and beyond. It consisted of a First Stage (FS) five segment solid rocket booster and a liquid J-2X Upper Stage (US) engine. Roll control for the FS was planned to be handled by a dedicated Roll Control System (RoCS), located on the connecting interstage. Induced yaw or pitch moments experienced during FS ascent would have been handled by vectoring of the booster nozzle. After FS booster separation, the US Reaction Control System (ReCS) would have provided the US Element with three degrees of freedom control as needed. The lessons learned documented in this paper will be focused on the technical designs and producibility of both systems along with the partnership between NASA and Boeing, who was on contract to build the Ares I US Element, which included the FS RoCS and US ReCS. In regards to partnership, focus will be placed on integration along with technical work accomplished by Boeing with special emphasis on each task order. In summary, this paper attempts to capture key lessons learned that should be helpful in the development of future launch vehicle RCS designs.

Butt, Adam↗

Best Practices from the Design and Development of the Ares I Launch Vehicle Roll and Reaction Control Systems

On April 15, 2010 President Barak Obama made the official announcement that the Constellation Program, which included the Ares I launch vehicle, would be canceled. NASA s Ares I launch vehicle was being designed to launch the Orion Crew Exploration Vehicle, returning humans to the moon, Mars, and beyond. It consisted of a First Stage (FS) five segment solid rocket booster and a liquid J-2X Upper Stage (US) engine. Roll control for the FS was planned to be handled by a dedicated Roll Control System (RoCS), located on the connecting interstage. Induced yaw or pitch moments experienced during FS ascent would have been handled by vectoring of the booster nozzle. After FS booster separation, the US Reaction Control System (ReCS) would have provided the US Element with three degrees of freedom control as needed. The best practices documented in this paper will be focused on the technical designs and producibility of both systems along with the partnership between NASA and Boeing, who was on contract to build the Ares I US Element, which included the FS RoCS and US ReCS. In regards to partnership, focus will be placed on integration along with technical work accomplished by Boeing. This will include detailed emphasis on task orders developed between NASA and Boeing that were used to direct specific work that needed to be accomplished. In summary, this paper attempts to capture key best practices that should be helpful in the development of future launch vehicle and spacecraft RCS designs.

Butt, Adam↗

On Advanced Estimation Techniques for Exoplanet Detection and Characterization using Ground-based Coronagraphs

The direct imaging of planets around nearby stars is exceedingly difficult. Only about 14 exoplanets have been imaged to date that have masses less than 13 times that of Jupiter. The next generation of planet-finding coronagraphs, including VLT-SPHERE, the Gemini Planet Imager, Palomar P1640, and Subaru HiCIAO have predicted contrast performance of roughly a thousand times less than would be needed to detect Earth-like planets. In this paper we review the state of the art in exoplanet imaging, most notably the method of Locally Optimized Combination of Images (LOCI), and we investigate the potential of improving the detectability of faint exoplanets through the use of advanced statistical methods based on the concepts of the ideal observer and the Hotelling observer. We propose a formal comparison of techniques using a blind data challenge with an evaluation of performance using the Receiver Operating Characteristic (ROC) and Localization ROC (LROC) curves. We place particular emphasis on the understanding and modeling of realistic sources of measurement noise in ground-based AO-corrected coronagraphs. The work reported in this paper is the result of interactions between the co-authors during a week-long workshop on exoplanet imaging that was held in Squaw Valley, California, in March of 2012

coronagraphs↗

On Advanced Estimation Techniques for Exoplanet Detection and Characterization using Ground-Based Coronagraphs

The direct imaging of planets around nearby stars is exceedingly difficult. Only about 14 exoplanets have been imaged to date that have masses less than 13 times that of Jupiter. The next generation of planet-finding coronagraphs, including VLT-SPHERE, the Gemini Planet Imager, Palomar P1640, and Subaru HiCIAO have predicted contrast performance of roughly a thousand times less than would be needed to detect Earth-like planets. In this paper we review the state of the art in exoplanet imaging, most notably the method of Locally Optimized Combination of Images (LOCI), and we investigate the potential of improving the detectability of faint exoplanets through the use of advanced statistical methods based on the concepts of the ideal observer and the Hotelling observer. We provide a formal comparison of techniques through a blind data challenge and evaluate performance using the Receiver Operating Characteristic (ROC) and Localization ROC (LROC) curves. We place particular emphasis on the understanding and modeling of realistic sources of measurement noise in ground-based AO-corrected coronagraphs. The work reported in this paper is the result of interactions between the co-authors during a week-long workshop on exoplanet imaging that was held in Squaw Valley, California, in March of 2012.

instrumentation↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

An Overview of Communications Technology and Development Efforts for 2015 SBIR Phase I

This report highlights innovative SBIR 2015 Phase I projects specifically addressing areas in Communications Technology and Development which is one of six core competencies at NASA Glenn Research Center. There are fifteen technologies featured with emphasis on a wide spectrum of applications such as novel solid state lasers for space-based water vapor dial; wide temperature, high voltage and energy density capacitors for aerospace exploration; instrument for airborne measurement of carbonyl sulfide; high-power tunable seed laser for methane Lidar transmitter; ROC-rib deployable ka-band antenna for nanosatellites; a SIC-based microcontroller for high-temperature in-situ instruments and systems; improved yield, performance and reliability of high-actuator-count deformable mirrors; embedded multifunctional optical sensor system; switching electronics for space-based telescopes with advanced AO systems; integrated miniature DBR laser module for Lidar instruments; and much more. Each article in this booklet describes an innovation, technical objective, and highlights NASA commercial and industrial applications. space-based water vapor dial; wide temperature, high voltage and energy density capacitors foraerospace exploration; instrument for airborne measurement of carbonyl sulfide; high-power tunable seed laser formethane Lidar transmitter; ROC-rib deployable ka-band antenna for nanosatellites.

space-based water vapor dial; wide temperature↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.

JWST↗

First Measurements of Ambient PM2.5 in Kinshasa, Democratic Republic of Congo and Brazzaville, Republic of Congo Using Field-calibrated Low-cost Sensors

Estimates of air pollution mortality in sub-Saharan Africa are limited by a lack of surface observations of fine particulate matter (PM2.5). Despite being large metropolises, Kinshasa, Democratic Republic of the Congo (DRC), population 14.3 million, and Brazzaville, Republic of the Congo (ROC), population 2.4 million, have no reference air pollution monitors at the time of writing. Recently, a few reference monitors have been deployed in other parts of sub-Saharan Africa, including Kampala, Uganda. A low-cost PurpleAir PM2.5 monitor was collocated next to the Kampala US Embassy BAM-1020 (Met One Beta Attenuation Monitor) starting in August 2019. Raw PurpleAir data are strongly correlated with the BAM (r(exp 2) = 0.88), but have a mean absolute error of approximately 14 μg/cu.m. Two calibration models, multiple linear regression and a random forest approach, decrease mean absolute error (MAE) from 14.3 μg/cu.m to 3.4 µg/cu.m or less and improve the the r(exp 2) from 0.88 to 0.96. Given )the similarity in climate and emissions in Kampala, we apply the collocated field correction factors to four PurpleAir sensors in Kinshasa, DRC and one in neighboring Brazzaville, ROC deployed beginning April 2018. Annual average PM2.5 for 2019 in Kinshasa is estimated at 43.5 µg/cu.m, more than 4 times higher than WHO Interim Target 1 of 10 µg/cu.m. Surface PM2.5 and aerosol optical depth were each about 40% lower during the 2020 COVID19 lockdown period compared to the same time period in 2019, which cannot be explained by changes in meteorology or wildfire emissions alone. Our results highlight the need for clean air solutions implementation in the Congo.

Celeste McFarlane↗

An Orbiting Sample Capture and Orientation System Architecture for Potential Mars Sample Return

An orbiting sample capture and orientation system architecture for a Rendezvous and Orbiting Sample Capture System (ROCS) concept was developed to enable spacecraft based, in-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel as part of a potential Mars Sample Return (MSR) campaign. An analysis of the system functions, requirements, interactions, and constraints was performed. A trade study was carried out on relevant technologies, and a set of evaluation criteria was developed to help determine the most feasible concepts for implementation. The Mars Capture and Re-orientation for the potential Next Mars Orbiter (MACARONE) concept is proposed as a promising system architecture for the ROCS Capture and Orient Module (COM). The concept uses a sliding trap door for Orbiting Sample (OS) capture, a Motorized Cups Mechanism for OS orientation, and a 2 DOF Turret Arm with a paddle for transferring the OS into a containment vessel. This approach facilitates modularity, development flexibility, test-ability in a 1G environment, analyze-ability without the need to simulate or test for 0G contact dynamics, ability to encapsulate potential dust surrounding the OS, and ability to be ejected to reduce the probability of Earth exposure to non-sterilized Mars material.

Lalla, Karan↗

Statistical Classification of Biosignature Information using Multiple Instrument Observations

The accurate identification of biosignatures (indications of life) from data taken from remote or in situ planetary exploration is one of the most important challenges in astrobiology, the interdisciplinary field examining habitability and the potential for extraterrestrial life. This study employs machine learning algorithms to optimize the identification of biosignatures, with an emphasis on those which are agnostic to a specific biochemical basis. We exploit the wealth of terrestrial data available from biogenic and abiogenic systems to enhance efficient feature prioritization. Our dataset, pulled from public databases and laboratory recorded measurements, includes elemental abundance, isotopic fractionation, and VNIR/Raman spectra The data curation process included standardization for detection limits and ranges. Subsequent feature extraction yielded detailed inputs for machine learning, including combinations of elemental content, isotopic ratios, and parameters of spectral peaks and troughs. Feature significance was evaluated across diverse machine learning methodologies, such as k-nearest neighbors, logistic regression, Random Forest, support vector machines, and Gaussian Naïve Bayes, along with a combined voting classifier. We utilized Receiver Operating Characteristic Area Under the Curve (ROC AUC) across 2,000 50% test-train splits as a robust metric of model performance. Results revealed a promising ROC AUC of 0.853 for the combined voting classifier. Removing elemental abundance data notably reduced model accuracy (13% decrease in AUC), highlighting its critical role in biosignature detection. Several other individual data features exhibited significance within their respective data types, offering additional granularity. This research fortifies the relevance of machine learning to astrobiology, potentially enhancing life detection missions by allowing algorithmic prioritization of high-interest samples for further investigation. Future work will refine data standardization, expand the dataset to include more terrestrial systems, and incorporate convolutional neural networks for spectral feature extraction. The potential for public data sharing is also under exploration, reinforcing our commitment to collective scientific advancement.

Statistical↗

Determining Coal Ash Impacts on Radium and Thorium Background Levels in Soil Using Rare Earth Element Analyses - 18604

One challenge at large remediation sites contaminated with radiological materials is differentiating between low-level site-related contamination and NORM. This is because sites contaminated with radiological materials, such as thorium processing and mining and milling facilities, often generate wastes that contain contaminants that are similar to NORM deposits. For sites in urban areas, this issue is further compounded due to the presence of historic industrial fill (historic fill) containing materials such as fly ash, coal ash, and red brick, that exhibit elevated radioactivity levels. These materials often have activity levels near, or even well above, a site's cleanup goal. At a large Superfund Site in the eastern US (Site), many of the suspected Site-related fill areas are commingled with coal and fly ash. As the cleanup criteria for the radionuclides of concern (ROC), radium (Ra) and thorium (Th), is 5 pico-Curies per gram above background, a four-pronged approach was developed to determine if the coal and fly ash are impacting the background levels of the ROCs. This evaluation included a review of boring logs to visually confirm the presence of historic fill, as well as coal fragments and coal ash; a literature review to establish the typical concentrations of Ra and Th found in coal and fly ash from US sources; the use of rare earth analyses to establish chemical signatures for non-Site related historic fill containing coal ash versus Site-related fill; and a quantitative analysis of Site-related data to determine if the radioactivity levels in historic fill containing coal were elevated. Soil samples were collected from two locations at the Site; fill areas containing coal ash that were not suspected to be impacted by Site activities, as well as fill areas containing coal ash that were associated with the former processing facility. These samples were analyzed for rare earth elements (REE), as well as Ra-228 and Th-232 and the ratios of lanthanum, cerium, and neodymium to Ra-228 and Th-232 were established for each sample. Based on a comparison of these data, a strong correlation was established between the rare earth/thorium decay chain ratios and the classification of material as either Site or non-Site related. These data were used to develop a higher background activity for fill areas containing non-Site related NORM. While the cleanup level defined in the Record of Decision remained unchanged, the higher background derived from the fly ash/coal ash material, as identified by REE analyses, resulted in higher project screening levels, which ensured that excavation activities did not 'chase' material that was not Site-related. To date, use of the coal ash background level has saved millions of dollars in cleanup costs since non-Site related contamination is not being remediated. Use of this approach to determine the appropriate background level for a site is relatively straightforward since it relies on visual observation of the soil for coal and fly ash, along with REE analyses, which is an inexpensive, quick, and established analytical method for soil samples. As long as a good rare earth profile of both contaminated and natural (in this case fly ash and coal ash) material can be established, the results can be quite definitive, which could result in significant volume reduction by minimizing the amount of material excavated and disposed of. This will lead to cost and time savings for what could be an otherwise costly and potentially complex excavation. Anyone performing environmental remediation of NORM contaminated sites may benefit from this paper and presentation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A likelihood ratio anomaly detector for identifying within-perimeter computer network attacks

The rapid detection of attackers within firewalls of enterprise computer networks is of paramount importance. Anomaly detectors address this problem by quantifying deviations from baseline statistical models of normal network behavior and signaling an intrusion when the observed data deviates significantly from the baseline model. But, many anomaly detectors do not take into account plausible attacker behavior. As a result, anomaly detectors are prone to a large number of false positives due to unusual but benign activity. Our paper first introduces a stochastic model of attacker behavior which is motivated by real world attacker traversal. Then, we develop a likelihood ratio detector that compares the probability of observed network behavior under normal conditions against the case when an attacker has possibly compromised a subset of hosts within the network. Since the likelihood ratio detector requires integrating over the time each host becomes compromised, we illustrate how to use Monte Carlo methods to compute the requisite integral. We then present Receiver Operating Characteristic (ROC) curves for various network parameterizations that show for any rate of true positives, the rate of false positives for the likelihood ratio detector is no higher than that of a simple anomaly detector and is often lower. Finally, we demonstrate the superiority of the proposed likelihood ratio detector when the network topologies and parameterizations are extracted from real-world networks.

97 MATHEMATICS AND COMPUTING↗

Three-Dimensional Phthalocyanine Metal-Catecholates for High Electrochemical Carbon Dioxide Reduction

The synthesis of a new anionic 3D metal-catecholate framework, termed MOF-1992, is achieved by linking tetratopic cobalt phthalocyanin-2,3,9,10,16,17,23,24-octaol linkers with Fe 3 (-C 2 O 2 -) 6 (OH 2 ) 2 trimers into an extended framework of roc topology. MOF-1992 exhibits sterically accessible Co active sites together with charge transfer properties. Cathodes based on MOF-1992 and carbon black (CB) display a high coverage of electroactive sites (270 nmol cm -2 ) and a high current density (-16.5 mA cm -2 ; overpotential, -0.52 V) for the CO 2 to CO reduction reaction in water (faradaic efficiency, 80%). Finally, over the 6 h experiment, MOF-1992/CB cathodes reach turnover numbers of 5800 with turnover frequencies of 0.20 s -1 per active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soil physical and chemical measurements for topsoils collected during NEON campaign in East River, CO (06/14/2018-06/28/2018)

The package is part of the DOE Watershed Function Science Focus Area (SFA) project and includes soil physical and chemical measurements from topsoils collected at the East River, Colorado, in conjunction with the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) survey conducted in June 2018. The soil measurements include soil bulk density, soil volumetric water content, soil microbial biomass C (Carbon), N (Nitrogen) and C:N (C to N ratio), soil DNA yield, soil total extractable organic C, soil total extractable N, soil extractable nitrate, soil extractable ammonium, soil dissolved inorganic N, soil dissolved organic N, soil pH, soil TOC400 (total organic carbon at 400°C), soil ROC (residual oxidizable carbon), soil TIC (total inorganic carbon), soil TOC (total organic carbon), soil TC (total carbon), soil N, soil OM (organic matter) loss on ignition. Additional associated site metadata can be found in the ESS-DIVE package 10.15485/1618130. The dataset includes (1) 2018_NEON_soil_physical_chemical_measurements.csv: soil physical and chemical measurements indexed by soil sample IGSNs; (2) samples.csv: sample metadata file used to register International Generic Sample Numbers (IGSNs); (3) flmd.csv: file level metadata file; and (4) dd.csv: data dictionary file. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS (Catchment Hydrology and ↗