Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-T-241: Monte Carlo Simulation Study About the Prediction of Proton-Induced DNA Strand Breakage On the Double Helix Structure

Purpose: In particle therapy and radiobiology, the investigation of mechanisms leading to the death of target cancer cells induced by ionising radiation is an active field of research. Recently, several studies based on Monte Carlo simulation codes have been initiated in order to simulate physical interactions of ionising particles at cellular scale and in DNA. Geant4-DNA is the one of them; it is an extension of the general purpose Geant4 Monte Carlo simulation toolkit for the simulation of physical interactions at sub-micrometre scale. In this study, we present Geant4-DNA Monte Carlo simulations for the prediction of DNA strand breakage using a geometrical modelling of DNA structure. Methods: For the simulation of DNA strand breakage, we developed a specific DNA geometrical structure. This structure consists of DNA components, such as the deoxynucleotide pairs, the DNA double helix, the nucleosomes and the chromatin fibre. Each component is made of water because the cross sections models currently available in Geant4-DNA for protons apply to liquid water only. Also, at the macroscopic-scale, protons were generated with various energies available for proton therapy at the National Cancer Center, obtained using validated proton beam simulations developed in previous studies. These multi-scale simulations were combined for the validation of Geant4-DNA in radiobiology. Results: In the double helix structure, the deposited energy in a strand allowed to determine direct DNA damage from physical interaction. In other words, the amount of dose and frequency of damage in microscopic geometries was related to direct radiobiological effect. Conclusion: In this report, we calculated the frequency of DNA strand breakage using Geant4- DNA physics processes for liquid water. This study is now on-going in order to develop geometries which use realistic DNA material, instead of liquid water. This will be tested as soon as cross sections for DNA material become available in Geant4-DNA.

60 APPLIED LIFE SCIENCES↗

Coarse graining approach to First principles modeling of structural materials

Classical Molecular Dynamic (MD) simulations characterizing extended defects typically require millions of atoms. First principles calculations employed to understand these defect systems at an electronic level cannot, and should not deal with such large numbers of atoms. We present an e cient coarse graining (CG) approach to calculate local electronic properties of large MD-generated structures from the rst principles. We used the Locally Self-consistent Multiple Scattering (LSMS) method for two types of iron defect structures 1) screw-dislocation dipoles and 2) radiation cascades. The multiple scattering equations are solved at fewer sites using the CG. The atomic positions were determined by MD with an embedded atom force eld. The local moments in the neighborhood of the defect cores are calculated with rst-principles based on full local structure information, while atoms in the rest of the system are modeled by representative atoms with approximated properties. This CG approach reduces computational costs signi cantly and makes large-scale structures amenable to rst principles study. Work is sponsored by the USDoE, O ce of Basic Energy Sciences, Center for Defect Physics, an Energy Frontier Research Center. This research used resources of the Oak Ridge Leadership Computing Facility at the ORNL, which is supported by the O ce of Science of the USDoE under Contract No. DE-AC05-00OR22725.

coarse grained↗

A Review of Tungsten Heavy Alloy Utilization in Isotope Transport Containers - 13380

A common requirement for radioisotope transport containers is that they provide both durable and efficient shielding of penetrating gamma radiation. This is the case for transport of both spent nuclear fuel as well as intentionally created radioisotopes for medical or other uses. Tungsten heavy alloy (WHA) provides a unique engineering property set for such shielding - easily surpassing more commonly used lead alloys in both strength and attenuation. This family of alloys contains typically 90-98 wt.% W in combination with transition metals such as Ni and Fe. WHA is manufactured in near net shape blanks by liquid phase sintering of compacted powder shapes to full metallurgical density parts. This powder metallurgy approach is described in its ability to provide excellent material utilization and affords efficient manufacturing of various shapes required for gamma shields or collimators. WHAs offer very high density (approaching 19 g/cc) in combination with relatively high thermal conductivity, low thermal expansion, ambient corrosion resistance, and can be provided with mechanical properties comparable to many medium carbon steels. As such, they can be machined to complex, damage resistant geometries using common metal cutting tools and methods. WHA additionally provides a lower toxicity alternative to Pb- or U-based gamma shielding. Given the specialty nature of WHA, specific metallurgical characteristics are reviewed to assist shielding designers who may otherwise encounter difficulties locating important alloy selection and fabrication details. Contained within this materials and applications overview are guidelines for WHA component design, alloy selection, and practical machining, finishing, and assembly considerations. The microstructure of WHA is that of a metal matrix composite. This factor has specific implications in the design of components for stress service as well as their protection in the presence of electrolytes. WHA is also discussed in the broader context of materials compatibility, as it is rarely used in isolated monolithic shapes. Alloy selection for new applications is often made primarily on the basis of density. An alternative strategy to this selection approach is presented which proposes that mechanical requirements for a given shielding use be the primary selection criterion over density. Standard commercial grades of WHA for radiation shielding are defined by specifications such as AMS-T-21014 and ASTM B777. These specifications define 4 density classes of as-sintered WHA. Compositional options, as well as post-sinter processing of WHA, are discussed for shielding components that must exhibit higher levels of ductility or very low magnetic permeability. In addition to the mechanical advantages over Pb-based shielding, the higher linear attenuation of energetic photons for various grades of WHA (as calculated by the NIST XCOM routine) are presented for selected photon energies of interest to illustrate the shield volume reduction generally possible through the use of tungsten-based shielding. While W provides inefficient attenuation of neutrons in a mixed radiation environment, its secondary role in shielding gamma radiation produced as a result of neutron capture is also described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of period and amplitude of microwaviness on KH{sub 2}PO{sub 4} crystal's laser damage threshold

The laser induced damage threshold (LIDT) has become a technical bottleneck which restricts the application and development of the inertial confinement fusion. Using single point diamond turning method to process KH{sub 2}PO{sub 4} (KDP) crystals, the periodic microwaviness will be left on the machined surface which has a significant impact on the LIDT. In this paper, after acquiring the frequency information of machined surface of KDP crystals with the power spectral density method, we analyze quantitatively the influence of microwaviness on the LIDT of KDP crystal with the Fourier modal theory. Research results indicate that: the surface morphology of KDP crystal is consisted of the subwaviness with different characteristic spatial frequencies; and the reduced amount of the LIDT of KDP crystal leaded by such subwaviness is different; the experimental results of the LIDT are consistent with the theoretical calculations basically; for the machine tool and the processing technology we used, the leading frequency of microwaviness which caused the LIDT decreasing is between (350 {mu}m){sup -1} and (30 {mu}m){sup -1}, especially between (90 {mu}m){sup -1} and (180 {mu}m){sup -1}.

36 MATERIALS SCIENCE↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Sensitivity Calculations

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-3D calculations performed to generate sensitivity data, and the companion paper discusses the selection of critical experiments applicable for validation of the 11 MPC-32 DPCs considered. The generation of sensitivity data for as-loaded spent nuclear fuel (SNF) DPCs is a challenge given the detailed model of the fuel compositions generated by UNF ST&DARDS. Each fuel assembly is modeled with its own irradiation history in 18 axial nodes, unless the fuel assembly is damaged and thus considered as fresh by design basis. This results in a set of 576 fuel compositions, each of which must be processed separately in a multigroup (MG) calculation. Therefore, a continuous-energy (CE) TSUNAMI-3D method was chosen to alleviate this challenge. Two CE TSUNAMI-3D methods are available in SCALE 6.2.3: the iterated fission probability (IFP) and contribution-linked eigenvalue sensitivity/uncertainty estimation via track-length importance characterization (CLUTCH). Since the IFP method is not feasible because of memory requirements associated with its implementation in SCALE, the CLUTCH method was selected for these calculations. CLUTCH has been implemented in SCALE in parallel, allowing long calculations to be performed in reasonable timeframes. The two primary user inputs necessary for CLUTCH calculations are the F*(r) mesh and the number of latent generations used in determining the F*(r) function. This F*(r) function is used as the importance function for fission chains originating in a given volume element (voxel), and it is calculated using the IFP method in the skipped generations. A large number of skipped generations is thus required to ensure accurate calculation of this importance function. In these calculations, 500 generations were used to calculate the F*(r) function. For more information regarding the calculation of F*(r), see Jones [4]. The remainder of this paper is focused on the selection of the F*(r) mesh and the number of latent generations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonlinear electronic excitations in crystalline solids using meta-generalized gradient approximation and hybrid functional in time-dependent density functional theory

We develop methods to calculate electron dynamics in crystalline solids in real-time time-dependent density functional theory employing exchange-correlation potentials which reproduce band gap energies of dielectrics; a meta-generalized gradient approximation was proposed by Tran and Blaha [Phys. Rev. Lett. 102, 226401 (2009)] (TBm-BJ) and a hybrid functional was proposed by Heyd, Scuseria, and Ernzerhof [J. Chem. Phys. 118, 8207 (2003)] (HSE). In time evolution calculations employing the TB-mBJ potential, we have found it necessary to adopt the predictor-corrector step for a stable time evolution. We have developed a method to evaluate electronic excitation energy without referring to the energy functional which is unknown for the TB-mBJ potential. For the HSE functional, we have developed a method for the operation of the Fock-like term in Fourier space to facilitate efficient use of massive parallel computers equipped with graphic processing units. We compare electronic excitations in silicon and germanium induced by femtosecond laser pulses using the TB-mBJ, HSE, and a simple local density approximation (LDA). At low laser intensities, electronic excitations are found to be sensitive to the band gap energy: they are close to each other using TB-mBJ and HSE and are much smaller in LDA. At high laser intensities close to the damage threshold, electronic excitation energies do not differ much among the three cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The role of radiation transport in the thermal response of semitransparent materials to localized laser heating

Lasers are widely used to modify the internal structure of semitransparent materials for a wide variety of applications, including waveguide fabrication and laser glass damage healing. The gray diffusion approximation used in past models to describe radiation cooling is not adequate for these materials, particularly near the heated surface layer. In this paper we describe a computational model based upon solving the radiation transport equation in 1D by the P n method with ~500 photon energy bands, and by multi-group radiationdiffusion in 2D with fourteen photon energy bands. The model accounts for the temperature-dependent absorption of infrared laser light and subsequent redistribution of the deposited heat by both radiation and conductive transport. We present representative results for fused silica irradiated with 2–12 W of 4.6 or 10.6 µm laser light for 5–10 s pulse durations in a 1 mm spot, which is small compared to the diameter and thickness of the silica slab. Furthermore, we show that, unlike the case for bulk heating, in localized infrared laser heatingradiation transport plays only a very small role in the thermal response of silica.

36 MATERIALS SCIENCE↗

SU-F-T-686: Considerations About Dose Protraction Factor in TCP Calculations for Prostate VMAT Treatments

Purpose: Dose protraction factor should be considered in order to model the TCP calculations. Nevertheless, this study describes a brief discussion showing that the lack of its inclusion should not invalidate these calculations for prostate VMAT treatments. Methods: Dose protraction factor (G) modifies the quadratic term of the linear-quadratic expression in order to take into account the sublethal damage repair of protracting the dose delivery. If the delivery takes a short time (instantaneous), G = 1. For any other dose delivery pattern, G < 1. The Lea-Catcheside dose protraction factor for external beam radiotherapy contains terms depending of on the tissue specific repair parameter (λ) and the irradiation time (T). Expanding the exponential term using a Taylor’s series and neglecting terms of order (λT){sup 3}, the approximation leads to G = 1. The described situation occurs for 3DCRT techniques, where treatment times are about few minutes. For IMRT techniques, fraction times are prolonged compared to 3DCRT times. Wang et al. (2003) and Fowler et al. (2004) investigated the protraction effect with respect to IMRT treatments, reporting clinically significant loss in biological effect associated with IMRT delivery times. Results: Treatment times are noticeably reduced for prostate treatments using VMAT techniques. These times are comparable to 3DCRT times, leading to consider the previous approximation. Conclusion: Dose protraction factor can be approximated by G = 1 in TCP calculations for prostate treatments using VMAT techniques.

60 APPLIED LIFE SCIENCES↗

Runaway electrons in tokamaks

The generation of runaway electrons is a complex and important phenomenon that impacts many areas of plasma physics. Due to the decrease of electron collision frequency with increasing velocity, electrons under strong electric field can experience unlimited “runaway” acceleration. In tokamaks, runaway electrons can be produced in disruptions, due to the strong inductive electric field formed as the thermal energy of plasma gets rapidly lost. This population of runaway electrons can undergo an exponential growth, denoted the runaway electron avalanche, due to hard collisions between relativistic runaway electrons and low energy electrons. It is predicted that in a large tokamak device like the International Thermonuclear Experimental Reactor (ITER), a runway electron beam generated in a disruption event can potentially cause severe damage to the device, which poses a significant challenge for ITER to achieve its mission. It is therefore extremely important to seek an effective mitigation mechanism for runaway electrons. Experimental efforts have been made to study the properties of runaway electrons in tokamaks, including their generation, diffusion, and radiation. In order to understand these experimental results, extensive theoretical and simulation studies of runaway electron physics are required. The main topic of this thesis is to study the wave particle interaction associated with runaway electron beams in tokamaks. The runaway electrons can emit and absorb electromagnetic waves through resonances, and can be diffused in momentum space by the waves. Initially, we address the Cherenkov radiation of runaway electrons, which originates from the polarization of the plasma medium. The energy and momentum loss of the Cherenkov radiation can be modeled by adding a correction to the Coulomb logarithm in the collisional drag force. Subsequently, we address pitch angle scattering caused by normal modes in the plasma, which are driven unstable by the anisotropicity of the runaway electron beam. The fluctuating electromagnetic fields are found to act as a seed for the unstable normal modes. Numerical simulations show that the pitch angle scattering effect from the normal modes, mainly whistler waves, can be significantly larger than that from collisional pitch angle scattering. Finally, we present a synthetic diagnostic tool we developed to calculate the electron cyclotron emission (ECE) from the runaway electrons, and successfully reproduce the prompt growth of the ECE signal observed in DIII-D quiescent runaway electron (QRE) experiments. Within the thesis, we also present the application of the adjoint method to runaway electron research, and show the calculations of the runaway probability function (RPF) and the expected loss time (ELT). These calculations not only help depict the dynamics of runaway electrons in momentum space, but also can be used to efficiently calculate experimentally relevant quantities such as the critical electric field for runaway electron avalanche and the avalanche growth rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ab initio molecular dynamics simulations of ion-solid interactions in zirconate pyrochlores

In this paper, an ab initio molecular dynamics method is employed to study low energy recoil events in zirconate pyrochlores (A 2 Zr 2 O 7 , A = La, Nd and Sm). It shows that both cations and anions in Nd 2 Zr 2 O 7 and Sm 2 Zr 2 O 7 are generally more likely to be displaced than those in La 2 Zr 2 O 7 . The damage end states mainly consist of Frenkel pair defects, and the Frenkel pair formation energies in Nd 2 Zr 2 O 7 and Sm 2 Zr 2 O 7 are lower than those in La 2 Zr 2 O 7 . These results suggest that the order–disorder structural transition more easily occurs in Nd 2 Zr 2 O 7 and Sm 2 Zr 2 O 7 resulting in a defect-fluorite structure, which agrees well with experimental observations. Our calculations indicate that oxygen migration from 48f and 8b to 8a sites is dominant under low energy irradiation. A number of new defects, including four types of cation Frenkel pairs and six types of anion Frenkel pairs, are revealed by ab initio molecular dynamics simulations. The present findings may help to advance the fundamental understanding of the irradiation response behavior of zirconate pyrochlores.

36 MATERIALS SCIENCE↗

Non-extensive radiobiology

The expression of survival factors for radiation damaged cells is based on probabilistic assumptions and experimentally fitted for each tumor, radiation and conditions. Here we show how the simplest of these radiobiological models can be derived from the maximum entropy principle of the classical Boltzmann-Gibbs expression. We extend this derivation using the Tsallis entropy and a cutoff hypothesis, motivated by clinical observations. A generalization of the exponential, the logarithm and the product to a non-extensive framework, provides a simple formula for the survival fraction corresponding to the application of several radiation doses on a living tissue. The obtained expression shows a remarkable agreement with the experimental data found in the literature, also providing a new interpretation of some of the parameters introduced anew. It is also shown how the presented formalism may have direct application in radiotherapy treatment optimization through the definition of the potential effect difference, simply calculated between the tumour and the surrounding tissue.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage induced by intense synchrotron radiation sources is indispensable for the correct interpretation of scattering data, there is still a lack of effective methods to overcome radiation-induced aggregation and extract scattering profiles free from chemical or structural damage. It is found that radiation-induced aggregation mainly begins on the surface of the sample cell and grows along the beam path; the diameter of the damaged region is comparable to the x-ray beam size. Radiation-induced aggregation can be effectively avoided by using a two-dimensional scan (2D mode), with an interval as small as 1.5 times the beam size, at low temperature (e.g., 4 deg. C). A radiation sensitive protein, bovine hemoglobin, was used to test the method. A standard deviation of less than 5% in the small angle region was observed from a series of nine spectra recorded in 2D mode, in contrast to the intensity variation seen using the conventional stationary technique, which can exceed 100%. Wide-angle x-ray scattering data were collected at a standard macromolecular diffraction station using the same data collection protocol and showed a good signal/noise ratio (better than the reported data on the same protein using a flow cell). The results indicate that this method is an effective approach for obtaining precise measurements of protein solution scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution of electric field and energy flux around the cracks on the surfaces of Nd-doped phosphate glasses

We simulate and calculate numerically the electromagnetic field and energy flux around a surface crack of an Nd-doped phosphate laser glass by using the finite-difference time-domain method. Because of a strong interference between the incident wave and the total internal reflections from the crack and the glass surface, the electric field is redistributed and enhanced. The results show that the electric-field distribution and corresponding energy flux component depend sensitively on the light polarization and crack geometry, such as orientation and depth. The polarization of the incident laser beam relative to the crack surfaces will determine the profile of the electric field around the crack. Under TE wave incidence, the energy flux peak is always inside the glass. But under TM wave incidence, the energy flux peak will be located inside the glass or inside the air gap. For both incident modes, the light intensification factor increases with the crack depth, especially for energy flux along the surface. Because cracks on the polished surfaces are the same as the roots extending down, the probability for much larger intensification occurring is high. The results suggest that the surface laser-damage threshold of Nd-doped phosphate may decrease dramatically with subsurface damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation Tolerant Interfaces: Influence of Local Stoichiometry at the Misfit Dislocation on Radiation Damage Resistance of Metal/Oxide Interfaces

To understand how variations in interface properties such as misfit-dislocation density and local chemistry affect radiation-induced defect absorption and recombination, we have explored a model system of CrxV1-x alloy epitaxial films deposited on MgO single crystals. By controlling film composition, the lattice mismatch with MgO was adjusted so that the misfit-dislocation density varies at the interface. These interfaces were exposed to irradiation and in situ results show that the film with a semi-coherent interface (Cr) withstands irradiation while V film, which has similar semi-coherent interface like Cr, showed the largest damage. Theoretical calculations indicate that, unlike at metal/metal interfaces, the misfit dislocation density does not dominate radiation damage tolerance at metal/oxide interfaces. Rather, the stoichiometry, and the precise location of the misfit-dislocation density relative to the interface, drives defect behavior. Together, these results demonstrate the sensitivity of defect recombination to interfacial chemistry and provide new avenues for engineering radiation-tolerant nanomaterials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

60 APPLIED LIFE SCIENCES↗

Measurements of emittance at low energy

Ideally, experimental measurements of all beam parameters should be made at the exit of the injector. This has not been possible on DARHT Axis-II for various practical reasons. In particular, the emittance has not been measured there. This note reviews the methods we have used for emittance measurements on the linear induction accelerator (LIA) at low-energy (< 10 MeV). It includes a discussion of some of the issues associated with making those measurements on a beam from the injector. A successful plan for emittance measurements at any energy should incorporate measures to deal with these issues. To begin with, it should be recognized that emittance measurements at the injector are not critical for beam physics in the accelerator. The emittance at the injector has very little effect on accelerator beam dynamics except for an increase in size near the end, where the beam becomes emittance dominated. Therefore, imperfect knowledge has little effect on the design and implementation of a tune. This point is illustrated in Fig. 1, which shows beam envelope calculations for our present tune over a wide range of emittances. Compare this with using the wrong diode voltage in the tune design. Figure 2 shows the effect on the beam envelope of a 2% error in the measurement of diode voltage. Therefore, a few years ago, when we made plans for beam measurements at the diode while we were upgrading the injector cells, our highest priority was on magnetic spectrometer measurements of energy. These measurements were to be used to cross calibrate the diode-voltage monitor, so that accurate diode voltage measurements could be made on every shot after the spectrometer was removed. If emittance measurements at the injector are required, then three widely used methods should be considered. These are focusing magnet scans, the use of an emittance mask (pepper pot), and optical transition radiation (OTR). We have used all three of these on our accelerators. These are invasive methods. There are noninvasive methods that we have not yet used. For example, under some conditions the beam size obtained with diamagnetic loops can be used in conjunction with the envelope equation to infer emittance. To date our diamagnetic loop data has not been of sufficient quality to do this. Another technique is to measure the beam-distribution quadrupole moment with BPMs dispersed in a quadrupole magnet lattice. Our BPMs have this capability, but the only quad lattice is in the downstream transport (DST), so this method is deferred until we operate the DST. All three methods reviewed here are invasive, and require the insertion of a target into the beam. Therefore, there is always the accompanying risk of inadvertent destruction of the target, and scattering of target material throughout the accelerator or injector. The target damage mechanism is target heating to a temperature hot enough to evolve gas, which is impact ionized by the beam, which is then ion focused to a small enough spot for the energy density to damage the target material, often destructively. Target heating is directly proportional to beam current density and pulse length. Therefore, the key to minimizing risk of target damage is to design for a large beam at the target, low current from the diode, and the shortest possible current pulse. The large-beam requirement compromises emittance measurements with OTR or focal scans, but not with the pepper pot technique. Finally, to ensure a short pulse even if the crowbar fails, the Marx generator should be reconfigured to produce the shortest possible pulse.

43 PARTICLE ACCELERATORS↗

VERA-Grizzly Ex-Core Calculations: Watts Bar Unit 1 Cycles 1-2

The critical structures that comprise light-water reactor (LWR) nuclear power plants are subjected to operating environments that can challenge their integrity. Structures in close proximity to the reactor core, such as the reactor pressure vessel (RPV) and the biological shield wall, are subjected to high levels of radiation emanating from the core, as well as elevated temperatures. As the US fleet of operating LWRs ages, the effects of these operating environments on the integrity of these structures must be considered to ensure their continued safe operation. Extending the lifetime of commercial reactors and maintaining the aging reactor fleet require accurate prediction of the exposure of ex-core components to neutron and photon radiation. In particular, concrete degradation studies must be performed to evaluate the safety and long-term operation of reactors with lifetime extensions. The concrete reactor bioshield is important for providing radiological protection during operation and must last for the entire lifetime of the reactor. Recent interest in lifetime extensions furthers the need to accurately simulate concrete material degradation in the reactor bioshield. As a result of this need, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has funded this study to couple its tools, Virtual Environment for Reactor Applications (VERA) and Grizzly. VERA allows users to set up models to calculate time-dependent and fully coupled solutions (with thermal feedback) for ex-core quantities of interest such as vessel and coupon fluence and detector responses for multiple statepoints and cycles. Grizzly is a finite-element application based on the Multiphysics Object Oriented Simulation Environment (MOOSE) framework that is used to enable aging materials calculations. This report highlights the work performed to calculate the fluence in the vessel and concrete for Watts Bar Nuclear Plant Unit 1 (WBN1) Cycles 1 and 2. The fluences obtained from VERA were successfully transferred to Grizzly using a Python script. Four simulations were run with Grizzly: (1) the Mazars model with the initial Young’s modulus being the instantaneous modulus, (2) the Mazars model with the initial Young’s modulus being the delayed modulus, (3) the Mazars model with the initial Young’s modulus being the delayed modulus with the addition of the effects of micro-damage caused by irradiation, and (4) the Mazars model with the initial Young’s modulus being the instantaneous modulus, and with the addition of micro-damage and creep. Details regarding the methods used to obtain the fluence and the statistical errors associated with the VERA Monte Carlo Shift calculations are discussed in greater detail in this report. The results obtained from the four Grizzly models are also presented in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-645: Dose Enhancement to Cell Nucleus Due to Hard Collisions of Protons with Electrons in Gold Nanospheres

Purpose: The purpose of this study was to investigate the theoretical dose enhancement to a cell nucleus due to increased fluence of secondary electrons when gold nanospheres are present in the cytoplasm during proton therapy. Methods: We modeled the irradiation of prostate cancer cells using protons of variable energies when 10,000 gold nanoparticles, each with radius of 10 nm, were randomly distributed in the cytoplasm. Using simple analytical equations, we calculated the increased mean dose to the cell nucleus due to secondary electrons produced by hard collisions of 0.1, 1, 10, and 100 MeV protons with orbital electrons in gold. We only counted electrons with kinetic energy higher than 1 keV. In addition to calculating the increase in the mean dose to the cell nucleus, we also calculated the increase in local dose in the “shadow,” i.e., the umbra, of individual gold nanospheres due to forward scattered electrons. Results: For proton energies of 0.1, 1, 10, and 100 MeV, we calculated increases to the mean nuclear dose of 0.15, 0.09, 0.05, and 0.04%, respectively. When we considered local dose increases in the shadows of individual gold spheres, we calculated local dose increases of 5.5, 3.2, 1.9, and 1.3%, respectively. Conclusion: We found negligible, less than 0.2%, increases in the mean dose to the cell nucleus due to electrons produced by hard collisions of protons with electrons in gold nanospheres. However, we observed increases up to 5.5% in the local dose in the shadow of gold nanospheres. Considering the shadow radius of 10 nm, these local dose enhancements may have implications for slightly increased probability of clustered DNA damage when gold nanoparticles are close to the nuclear membrane.

60 APPLIED LIFE SCIENCES↗