Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Observation And Modeling Of Inner Divertor Re-attachment In Discharges With Lithium Coatings in NSTX

In the National Spherical Torus Experiment (NSTX), modifications to the inner divertor plasma regimes are observed in high triangularity, H-mode, NBI heated discharges due to lithium coatings evaporated on the plasma facing components. In particular, the drop in the recombination rate, the reduced neutral pressure and the reduced electron density (inferred from Stark broadening measurements of high-n deuterium Balmer lines) suggested that the inner divertor, which is usually detached in discharges without lithium, re-attached. Experimental results are compared to simulations obtained with a 1D partially ionized plasma transport model integrated in the non-local thermodynamic equilibrium radiation transport code CRETIN to understand how the reduced recycling affects the divertor parameters in NSTX discharges with lithium coatings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MCNPX-CINDER'90 Simulation of Photonuclear Mo-99 Production Experiments

The MCNPX and CINDER'90 codes were used to support design of experiments investigating Mo-99 production with a 20-MeV electron beam. Bremsstrahlung photons produced by the electron beam interacting with the target drive the desired Mo-100({gamma},n)Mo-99 reaction, as well as many undesired reactions important to accurate prediction of radiation hazards. MCNPX is a radiation transport code and CINDER'90 is a transmutation code. They are routinely used together for accelerator activation calculations. Low energy neutron fluxes and production rates for nonneutron and high energy neutron induced reactions computed using MCNPX are inputs to CINDER'90. CINDER'90 presently has only a neutron reaction cross section library up to 25 MeV and normally the other reaction rates come from MCNPX physics models. For this work MCNPX photon flux tallies modified by energy response functions prepared from evaluated photonuclear cross section data were used to tally the reaction rates for CINDER'90 input. The cross section evaluations do not provide isomer to ground state yield ratios so a spin based approximation was used. Post irradiation dose rates were calculated using MCNPX with CINDER'90 produced decay photon spectra. The sensitivity of radionuclide activities and dose rates to beam parameters including energy, position, and profile, as well as underlying isomer assumptions, was investigated. Three experimental production targets were irradiated, two natural Mo and one Mo-100 enriched. Natural Mo foils upstream of the targets were used to analyze beam position and profile by exposing Gafchromic film to the foils after each irradiation. Activation and dose rate calculations were rerun after the experiments using measured beam parameters for comparison with measured Mo-99 activities and dose rates.

Accelerator Design, Technology, and Operations↗

Fe kα profiles from simulations of accreting black holes

We present the first results from a new technique for the prediction of Fe Kα profiles directly from general relativistic magnetohydrodynamic (GRMHD) simulations. Data from a GRMHD simulation are processed by a Monte Carlo global radiation transport code, which determines the X-ray flux irradiating the disk surface and the coronal electron temperature self-consistently. With that irradiating flux and the disk’s density structure drawn from the simulation, we determine the reprocessed Fe Kα emission from photoionization equilibrium and solution of the radiation transfer equation. We produce maps of the surface brightness of Fe Kα emission over the disk surface, which—for our example of a 10M{sub ⊙} Schwarzschild black hole accreting at 1% the Eddington value—rises steeply one gravitational radius outside the radius of the innermost stable circular orbit and then falls ∝r {sup −2} at larger radii. We explain these features of the Fe Kα radial surface brightness profile as consequences of the disk’s ionization structure and an extended coronal geometry, respectively. We also present the corresponding Fe Kα line profiles as would be seen by distant observers at several inclinations. Both the shapes of the line profiles and the equivalent widths of our predicted Kα lines are qualitatively similar to those typically observed from accreting black holes. Most importantly, this work represents a direct link between theory and observation: in a fully self-consistent way, we produce observable results—iron fluorescence line profiles—from the theory of black hole accretion with almost no phenomenological assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear Resonance Fluorescence for Safeguards Applications

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of {gamma} rays with specific energies that are characteristic of the emitting isotope. The promise of NRF as a non-destructive analysis technique (NDA) in safeguards applications lies in its potential to directly quantify a specific isotope in an assay target without the need for unfolding the combined responses of several fissile isotopes as often required by other NDA methods. The use of NRF for detection of sensitive nuclear materials and other contraband has been researched in the past. In the safeguards applications considered here one has to go beyond mere detection and precisely quantify the isotopic content, a challenge that is discussed throughout this report. Basic NRF measurement methods, instrumentation, and the analytical calculation of NRF signal strengths are described in Section 2. Well understood modeling and simulation tools are needed for assessing the potential of NRF for safeguards and for designing measurement systems. All our simulations were performed with the radiation transport code MCNPX, a code that is widely used in the safeguards community. Our initial studies showed that MCNPX grossly underestimated the elastically scattered background at backwards angles due to an incorrect treatment of Rayleigh scattering. While new, corrected calculations based on ENDF form factors showed much better agreement with experimental data for the elastic scattering of photons on an uranium target, the elastic backscatter is still not rigorously treated. Photonuclear scattering processes (nuclear Thomson, Delbruck and Giant Dipole Resonance scattering), which are expected to play an important role at higher energies, are not yet included. These missing elastic scattering contributions were studied and their importance evaluated evaluated against data found in the literature as discussed in Section 3. A transmission experiment was performed in September 2009 to test and demonstrate the applicability of the method to the quantitative measurement of an isotope of interest embedded in a thick target. The experiment, data analysis, and results are described in Section 4. The broad goal of our NRF studies is to assess the potential of the technique in safeguards applications. Three examples are analyzed in Section 5: the isotopic assay of spent nuclear fuel (SNF), the measurement of {sup 235}U enrichment in UF{sub 6} cylinders, and the determination of {sup 239}Pu in mixed oxide (MOX) fuel. The study of NRF for the assay of SNF assemblies was supported by the Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy as part of a large multi-lab/university effort to quantify the plutonium (Pu) mass in spent nuclear fuel assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. NRF is one of 14 NDA techniques being researched. The methodology for performing and analyzing quantitative NRF measurements was developed for determining Pu mass in SNF and is extensively discussed in this report. The same methodology was applied to the assessment of NRF for the measurement of {sup 235}U enrichment and the determination of {sup 239}Pu in MOX fuel. The analysis centers on determining suitable NRF measurement methods, measurement capabilities that could be realized with currently available instrumentation, and photon source and detector requirements for achieving useful NDA capabilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Validation of the single-event method for low-energy electron transport via stopping power calculations with $\mathrm{MCNP}$

Monte Carlo simulations of low-energy ( <50 keV) electron transport in matter are essential for a broad range of application fields. Several Monte Carlo codes have developed specialized treatments for this case, but a comprehensive validation of low-energy electron transport for general-purpose simulations remains lacking in the literature. One approach to accomplish this validation is calculation of stopping power using low-energy electron transport physics, as stopping power is a fundamental radiation transport quantity which must be simulated accurately for nearly any application. Here in this work, we use the Monte Carlo N-Particle (MCNP) radiation transport code with the single-event method for electron transport to calculate stopping powers of low-energy electrons (50 eV to 30 keV) in 41 elemental solids, 14 compound solids, and five rare gas solids, comparing simulation results to published semi-empirical stopping power calculations from optical measurements. In general, the simulations give good agreement (typically within ±10%) with semi-empirical stopping power values at higher energies: 300 eV and above for most elemental solids, 1 keV and above for compound solids, and 400 eV and above for rare gas solids. Agreement between MCNP and semi-empirical values is worse below these energies. The most significant source of error is the EPRDATA14 cross section data, which does not account for changes in electronic structure due to solid-state bonding, particularly in compound materials. The simplistic model of atomic excitation used to generate the EPRDATA14 cross sections is another key source of error. Additionally, the breakdown of the continuous slowing-down approximation introduces significant uncertainty at low energies, although this is a limitation of the calculation method and not of the simulation procedure. Accounting for these and other uncertainty sources, the single event method in MCNP is robust and able to give good accuracy for a variety of low-energy electron transport problems through diverse kinds of materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of switching to the ICRP-74 neutron flux-to-dose equivalent rate conversion factors at the Sandia National Laboratory Building 818 Neutron Source Range.

Sandia National Laboratories (SNL) maintains a neutron calibration facility which supports the calibration, maintenance, and repair of Radiation Protection Instruments. The SNL neutron reference fields are calibrated using the following methodology: Fluence rate is initially established by calculation using the NIST traceable source emission rate (decay corrected). Correction factors for the effects of room return or scatter, and source anisotropy are then developed by using a suitable radiation transport code to model the geometry of the facility. The conventionally true neutron dose rates are then determined using the appropriate fluence-todose equivalent conversion coefficients at several reference positions. This report describes the impact on calculated neutron dose rates of switching from NCRP-38 to CRP-74 neutron flux-todose equivalent rate conversion factors. This switch is driven by recent changes to dosimetry requirements addressed in 10 CFR 835 (Occupational Radiation Protection).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo Laplace Transform Estimator for Radiation Transport

This work formulates and implements a Laplace transform estimator in a simple Monte Carlo radiation transport code. The estimator maps flux-based quantities of interest, like reaction rates, from a desired phase-space dimension to the complex Laplace domain. This on-the-fly Monte Carlo integration technique enables the spectral analysis of arbitrary nuclear systems via the Laplace transform. A simple code tests the estimator in neutron slowing-down problems across various infinite media, and the results compare well with Ganapol’s uninverted analytical solution of the neutron slowing-down equation.

97 MATHEMATICS AND COMPUTING↗

AFIT and LANL Collaboration Research Proposals [Slides]

MCNP is a general-purpose, continuous-energy, generalized-geometry, time-dependent, Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. MCNP has the capability to track particles on unstructured polyhedral meshes that are embedded into the legacy constructive solid geometry (CSG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm{sup 3}, respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm{sup 3}. The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom.

60 APPLIED LIFE SCIENCES↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

Determination of integral cross sections of 3 H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

Our results of 3 H production in Al foil monitors (~ 59 mg/cm 2 thickness) are presented. We irradiated these foils in 15×15 mm polyethylene bags of ~ 14 mg/cm 2 thickness together with foils of Cr (~ 395 mg/cm 2 thickness) and 56 Fe (~ 332 mg/cm 2 thickness) by protons of different energies in a range of 0.04 – 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U–10 under the ISTC Project # 3266 in 2006–2009. 3 H has been extracted from Al foils using an A307 Sample Oxidizer. We then used an ultra low level liquid scintillation spectrometer Quantulus1220 to measure the 3 H β–spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3 H activity determination. The values of the Al (p, x) 3 H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

42 ENGINEERING↗

Air Activation Calculations for Electron Linear Accelerators - Paper 114

Electron linear accelerators produce x-ray photons when the beam interacts with material such as beam stops or beamline components. These photons subsequently cause radioactivation in air, primarily through ({gamma},n) reactions. While most of these nuclides have short half-lives, they can lead to doses to personnel entering the accelerator or experimental areas and can be released to the environment. Accurate calculations are needed for the production, decay, and clearance of these nuclides. This paper discusses two treatments of air activation. An approximate treatment makes use of the fact that the Bremsstrahlung photon fluence is proportional to beam power and the path length in air, but does not account for heavily shielded loss points or how far the beam energy is above each reaction threshold. Using detailed radiation transport codes like MCNPX avoids these problems. Examples are provided for two electron linear accelerators at Argonne National Laboratory: the Low-Energy Accelerator Facility (LEAF) and the Argonne Wakefield Accelerator (AWA). MCNPX was used to calculate photonuclear reaction rates in the air at two electron accelerators at Argonne. Combined with realistic models for air exhaust, these results were used to calculate effects to facility staff, other personnel, and the environment. (authors)

43 PARTICLE ACCELERATORS↗

Review of Heavy Charged Particle Transport in MCNP6.2

The release of version 6.2 of the MCNP6 radiation transport code is imminent. To complement the newest release, a summary of the heavy charged particle physics models used in the 1 MeV to 1 GeV energy regime is presented. Several changes have been introduced into the charged particle physics models since the merger of the MCNP5 and MCNPX codes into MCNP6. Here, this article discusses the default models used in MCNP6 for continuous energy loss, energy straggling, and angular scattering of heavy charged particles. Explanations of the physics models’ theories are included as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MCNP6 Cosmic-Source Option

MCNP is a Monte Carlo radiation transport code that has been under development for over half a century. Over the last decade, the development team of a high-energy offshoot of MCNP, called MCNPX, has implemented several physics and algorithm improvements important for modeling galactic cosmic-ray (GCR) interactions with matter. In this presentation, we discuss the latest of these improvements, a new Cosmic-Source option, that has been implemented in MCNP6.

07 ISOTOPE AND RADIATION SOURCES↗

GPU Acceleration of Kernel Density Estimators in Monte Carlo Neutron Transport Simulations

Kernel Density Estimators (KDEs) have recently been explored for use in Monte Carlo radiation transport simulations as an alternative to histogram tallies for capturing spatially-resolved quantities such as neutron flux and reaction rates. Histogram tallies suffer from large uncertainties when detailed spatial resolution of the quantity of interest is required; increasing the resolution of the underlying mesh increases the uncertainty in each histogram bin. KDEs obtain estimates of underlying densities on user-defined points, with the uncertainty at those points being independent of the spatial resolution desired since collisions and particle-track segments are allowed to contribute to the score at multiple tally points. Thus, KDEs show potential for obtaining estimates of a smoother spatially-resolved with reduced variance when compared to a histogram. However, this ability that enables KDEs to obtain lower uncertainties per particle history is more computationally expensive than using a traditional histogram bins on a structured mesh. While KDEs are capable of producing lower tally uncertainties compared to histogram binning for a given number of histories, their increased computational cost may make them less efficient. Even so, it is possible to reduce this additional cost by exporting the KDE tally routines onto Graphics Processing Units (GPUs). GPUs are commonly found on high-performance computing machines as a means of increasing performance without adding additional compute nodes. While it is difficult for existing Monte Carlo radiation transport codes to take advantage of GPUs without rewriting large portions of the code, it is possible to leverage GPUs through heterogeneous computing. This work uses a modified version of OpenMC and exports the KDE tally routines onto a GPU to obtain problem-dependent speedups ranging between 1.6 and 5.0 for the problem studied in this paper. While this methodology is applied to KDEs, the same ideas can be applied to other computationally expensive vectorizable portions of Monte Carlo algorithms. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Application of MCNP6.2 Unstructured Mesh Geometry Capabilities to the Study of Heavy Ion Single Event Effect on Microelectronic Devices and the Reactor Physics Analysis - 25691

Unstructured meshes allow irregular or complex geometries to be modeled precisely in Monte Carlo radiation transport codes. Through this capability, it is possible to share an unstructured mesh model between multiple codes that use unstructured mesh geometry and thus improving coupled multi-physics simulations. In this work, unstructured meshes are used to model energy deposition from heavy ion strikes for single event effects on microelectronic devices as well as neutron flux mapping of nuclear reactor configurations. In each case, MCNP6.2's unstructured mesh functionality and applicability to the problem is demonstrated and analyzed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗