Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

𝐹 𝐾 ⁡/𝐹 𝜋 from Möbius domain-wall fermions solved on gradient-flowed HISQ ensembles

We report the results of a lattice quantum chromodynamics calculation of 𝐹 𝐾 ⁡/𝐹 𝜋 using Möbius domain-wall fermions computed on gradient-flowed 𝑁 𝑓 =2 +1 +1 highly improved staggered quark (HISQ) ensembles. The calculation is performed with five values of the pion mass ranging from 130 ≲ 𝑚 𝜋 ≲ 400 MeV , four lattice spacings of 𝑎 ∼ 0.15, 0.12, 0.09 and 0.06 fm and multiple values of the lattice volume. The interpolation/extrapolation to the physical pion and kaon mass point, the continuum, and infinite volume limits are performed with a variety of different extrapolation functions utilizing both the relevant mixed-action effective field theory expressions as well as discretization-enhanced continuum chiral perturbation theory formulas. We find that the 𝑎 ∼ 0.06 fm ensemble is helpful, but not necessary to achieve a subpercent determination of 𝐹 𝐾 ⁡/𝐹 𝜋 . We also include an estimate of the strong isospin breaking corrections and arrive at a final result of 𝐹 $\hat{K}$ + ⁡ /𝐹 $\hat{𝜋}$ + = 1.1942⁢(45) with all sources of statistical and systematic uncertainty included. This is consistent with the Flavour Lattice Averaging Group average value, providing an important benchmark for our lattice action. Combining our result with experimental measurements of the pion and kaon leptonic decays leads to a determination of |𝑉 𝑢⁢𝑠 |/|𝑉 𝑢⁢𝑑 | = 0.2311⁢(10).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Singular value decomposition of adjoint flux distributions for Monte Carlo variance reduction

Monte Carlo (MC) shielding calculations often use weight windows (WWs) and biased sources formed from a deterministic estimate of the adjoint flux to improve the convergence rate of tallies. This requires a significant amount of computer memory, which can limit the memory available for high-resolution tally output. A new method is proposed for reducing these memory requirements by using singular value decomposition (SVD) in linear or logarithmic space to approximate the adjoint flux. This method’s performance is evaluated using the Shift and Denovo codes for streaming and diffusion base case problems, followed by problems using the Westinghouse AP1000 and the Joint European Torus. The log SVD reduced WW memory requirements by an order of magnitude in all cases without a significant performance penalty. Additionally, the linear SVD reduced biased source memory requirements by an order of magnitude, but further investigation is needed to account for observed limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An analysis of gamma-ray data collected at traffic intersections in Northern Virginia

Gamma-ray spectral data were collected from sensors mounted to traffic signals around Northern Virginia. The data were collected over a span of approximately fifteen months. A subset of the data were analyzed manually and subsequently used to train machine-learning models to facilitate the evaluation of the remaining 50k anomalous events identified in the dataset. We describe the analysis approach used here and discuss the results in terms of radioisotope classes and frequency patterns over day-of-week and time-of-day spans. Data from this work has been archived and is available for future and ongoing research applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nucleon axial-vector form factor and radius from future neutrino experiments

Precision measurements of antineutrino elastic scattering on hydrogen from future neutrino experiments offer a unique opportunity to access the low-energy structure of protons and neutrons. We discuss the determination of the nucleon axial-vector form factor and radius from antineutrino interactions on hydrogen that can be collected at the future Long-Baseline Neutrino Facility and study the sources of theoretical and experimental uncertainties. The projected accuracy would improve existing measurements by 1 order of magnitude and be competitive with contemporary lattice-QCD determinations, potentially helping to resolve the corresponding tension with measurements from (anti)neutrino elastic scattering on deuterium. We find that the current knowledge of the nucleon vector form factors could be one of the dominant sources of uncertainty. We also evaluate the constraints that can be simultaneously obtained on the absolute ν ¯ μ flux normalization. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resonance Scattering Treatment with the Windowed Multipole Formalism

A new method for directly sampling the resonance upscattering effect is presented. Alternatives have relied on inefficient rejection sampling techniques or large tabular storage of relative velocities. None of these approaches, which require pointwise energy data, are particularly well suited to the windowed multipole cross-section representation. The new method, called multipole analytic resonance scattering, overcomes these limitations by inverse transform sampling from the target relative velocity distribution where the cross section is expressed in the multipole formalism. The closed-form relative speed distribution contains a novel special function we deem the incomplete Faddeeva function, and we present the first results on its efficient numerical evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Second Moment Method for k -Eigenvalue Acceleration with Continuous Diffusion and Discontinuous Transport Discretizations

The second moment method is a linear acceleration technique that couples the transport equation to a diffusion equation with transport-dependent additive closures. The resulting low-order diffusion equation can be discretized independent of the transport discretization, unlike diffusion synthetic acceleration, and is symmetric positive definite, unlike quasidiffusion. While this method has been shown to be comparable to quasidiffusion in iterative performance for fixed source and time-dependent problems, it is largely unexplored as an eigenvalue problem acceleration scheme due to the belief that the resulting inhomogeneous source makes the problem ill posed. Recently, a preliminary feasibility study was performed on the second moment method for eigenvalue problems. The results suggested comparable performance to quasidiffusion and more robust performance than diffusion synthetic acceleration. This work extends the initial study to more realistic reactor problems using state-of-the-art discretization techniques. Finally, the results in this paper show that the second moment method is more computationally efficient than its alternatives on complex reactor problems with unstructured meshes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revised decay properties of the key 93-keV resonance in the Mg 25 ( p , γ ) reaction and its influence on the MgAl cycle in astrophysical environments

The γ-decay properties of an excited state in 26 Al at 6398.3(8) keV have been reexamined using the 11 B+ 16 O fusion-evaporation reaction. This level represents a key 93.1(8)-keV resonance in the 25 Mg+p system and its relative branching to the 26 Al ground state, f 0 , has been determined to be 0.76 ± 0.03 (stat.) ± 0.10 (syst.). Furthermore, this is a significantly higher value than the most recent evaluation and implies a considerable increase in the production of cosmic γ rays from 26 Al radioactivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of φ-meson production in Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV

The PHENIX experiment reports systematic measurements at the Relativistic Heavy Ion Collider of φ-meson production in asymmetric Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and in U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV. Measurements were performed via the φ → K + K – decay channel at midrapidity |η| < 0.35. Features of φ- meson production measured in Cu + Cu, Cu + Au, Au + Au, and U + U collisions were found to not depend on the collision geometry, which was expected because the yields are averaged over the azimuthal angle and follow the expected scaling with nuclear-overlap size. The elliptic flow of the φ meson in Cu + Au, Au + Au, and U + U collisions scales with second-order-participant eccentricity and the length scale of the nuclear-overlap region (estimated with the number of participating nucleons). At moderate $p_T$ , φ-meson production measured in Cu + Au and U + U collisions is consistent with coalescence-model predictions, whereas at high $p_T$ the production is in agreement with expectations for in-medium energy loss of parent partons prior to their fragmentation. Finally, the elliptic flow for φ mesons measured in Cu + Au and U + U collisions is well described by a (2+1)-dimensional viscous-hydrodynamic model with specific-shear viscosity η/s = 1/4π.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗