Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Passive Microwave Radiometry and Active Radar Sounding as Complementary Tools for Geophysical Investigations of Icy Ocean Worlds

Juno Microwave Radiometer (MWR) observations of Europa and Ganymede offer critical insights into the icy shells of these moons ahead of NASA's Europa Clipper and ESA's JUpiter ICy moons Explorer (JUICE) missions. Both missions are equipped with active radar sounders designed to address key unknowns such as ice shell thickness, thermal state, and composition. In this study, we explore how passive microwave radiometry and active radar sounding can constrain ice shell properties, focusing on Europa. Using modeled microwave brightness temperature observations at 0.6 and 1.2 GHz alongside simulated radar attenuation rate observations, we show that each instrument can independently produce robust ice shell thickness constraints under idealized conditions. We then relax these assumptions, quantifying how uncertainties from non-ideal properties—including convective layers, freezing-point depression, and chloride-doped ice—affect thickness estimates. Finally, we demonstrate how combining observations from these complementary techniques breaks degeneracies between ice shell properties, enabling more robust constraints than either method alone. This approach will maximize the science return of Europa Clipper and JUICE, advancing our understanding of the thermophysical structure and habitability of icy ocean worlds.

58 GEOSCIENCES↗

Spatial variability in Arctic–boreal fire regimes influenced by environmental and human factors

Abstract Wildfire activity in Arctic and boreal regions is rapidly increasing, with severe consequences for climate and human health. Regional long-term variations in fire frequency and intensity characterize fire regimes. The spatial variability in Arctic–boreal fire regimes and their environmental and anthropogenic drivers, however, remain poorly understood. Here we present a fire tracking system to map the sub-daily evolution of all circumpolar Arctic–boreal fires between 2012 and 2023 using 375 m Visible Infrared Imaging Radiometer Suite active fire detections and the resulting dataset of the ignition time, location, size, duration, spread and intensity of individual fires. We use this dataset to classify the Arctic–boreal biomes into seven distinct ‘pyroregions’ with unique climatic and geographic environments. We find that these pyroregions exhibit varying responses to environmental drivers, with boreal North America, eastern Siberia and northern tundra regions showing the highest sensitivity to climate and lightning density. In addition, anthropogenic factors play an important role in influencing fire number and size, interacting with other factors. Understanding the spatial variability of fire regimes and its interconnected drivers in the Arctic–boreal domain is important for improving future predictions of fire activity and identifying areas at risk for extreme events.

Geology↗

A harmonized global nighttime light dataset 1992–2018

Nighttime light (NTL) data from the Defense Meteorological Satellite Program (DMSP)/Operational Linescan System (OLS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite provide a great opportunity for monitoring human activities from regional to global scales. Despite the valuable records of nightscape from DMSP (1992–2013) and VIIRS (2012–2018), the potential of the historical archive of NTL observations has not been fully explored because of the severe inconsistency between DMSP and VIIRS. In this study, we generated an integrated and consistent NTL dataset at the global scale by harmonizing the inter-calibrated NTL observations from the DMSP data and the simulated DMSP-like NTL observations from the VIIRS data. The generated global DMSP NTL time-series data (1992–2018) show consistent temporal trends. This temporally extended DMSP NTL dataset provides valuable support for various studies related to human activities such as electricity consumption and urban extent dynamics.

54 ENVIRONMENTAL SCIENCES↗

California wildfire spread derived using VIIRS satellite observations and an object-based tracking system

Changing wildfire regimes in the western US and other fire-prone regions pose considerable risks to human health and ecosystem function. However, our understanding of wildfire behavior is still limited by a lack of data products that systematically quantify fire spread, behavior and impacts. Here we develop a novel object-based system for tracking the progression of individual fires using 375 m Visible Infrared Imaging Radiometer Suite active fire detections. At each half-daily time step, fire pixels are clustered according to their spatial proximity, and are either appended to an existing active fire object or are assigned to a new object. This automatic system allows us to update the attributes of each fire event, delineate the fire perimeter, and identify the active fire front shortly after satellite data acquisition. Using this system, we mapped the history of California fires during 2012–2020. Our approach and data stream may be useful for calibration and evaluation of fire spread models, estimation of near-real-time wildfire emissions, and as means for prescribing initial conditions in fire forecast models.

54 ENVIRONMENTAL SCIENCES↗

Cloud micro- and macrophysical properties from ground-based remote sensing during the MOSAiC drift experiment

In the framework of the Multidisciplinary drifting Observatory for the Study of Arctic Climate Polarstern expedition, the Leibniz Institute for Tropospheric Research, Leipzig, Germany, operated the shipborne OCEANET-Atmosphere facility for cloud and aerosol observations throughout the whole year. OCEANET-Atmosphere comprises, amongst others, a multiwavelength Raman lidar, a microwave radiometer, and an optical disdrometer. A cloud radar was operated aboard Polarstern by the US Atmospheric Radiation Measurement program. These measurements were processed by applying the so-called Cloudnet methodology to derive cloud properties. To gain a comprehensive view of the clouds, lidar and cloud radar capabilities for low- and high-altitude observations were combined. Cloudnet offers a variety of products with a spatiotemporal resolution of 30 s and 30 m, such as the target classification, and liquid and ice microphysical properties. Additionally, a lidar-based low-level stratus retrieval was applied for cloud detection below the lowest range gate of the cloud radar. Based on the presented dataset, e.g., studies on cloud formation processes and their radiative impact, and model evaluation studies can be conducted.

54 ENVIRONMENTAL SCIENCES↗

Natural and enriched Cr target development for production of Manganese-52

52 Mn is a promising PET radiometal with a half-life of 5.6 days and an average positron energy of 242 keV. Typically, chromium of natural isotope abundance is used as a target material to produce this isotope through the nat/52 Cr(p,n) 52 Mn reaction. While natural Cr is a suitable target material, higher purity 52 Mn could be produced by transitioning to enriched 52 Cr targets to prevent the co-production of long-lived 54 Mn (t 1/2 = 312 day). Unfortunately, 52 Cr targets are not cost-effective without recycling processes in place, therefore, this work aims to explore routes to prepare Cr targets that could be recycled. Natural Cr foils, metal powder pellets, enriched chromium-52 oxide and Cr(III) electroplated targets were investigated in this work. Each of these cyclotron targets were irradiated, and the produced 52 Mn was purified, when possible, using a semi-automated system. An improved purification by solid-phase anion exchange from ethanol-HCl mixtures resulted in recoveries of 94.5 ± 2.2% of 52 Mn. The most promising target configuration to produce a recyclable target was electroplated Cr(III). This work presents several pathways to optimize enriched Cr targets for the production of high purity 52 Mn.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tuning aminopolycarboxylate chelators for efficient complexation of trivalent actinides

The complexation of trivalent lanthanides and minor actinides (Am 3+ , Cm 3+ , and Cf 3+ ) by the acyclic aminopolycarboxylate chelators 6,6'-((ethane-1,2-diylbis–((carboxymethyl)azanediyl))bis–(methylene))dipicolinic acid (H 4 octapa) and 6,6'-((((4-(1-(2-(2-(2-hydroxyethoxy)ethoxy)ethyl)-1H-1,2,3-triazol-4-yl)pyridine-2,6-diyl)bis–(methylene))bis–((carboxymethyl)azanediyl))bis–(methylene)) dipicolinic acid (H 4 pypa-peg) were studied using potentiometry, spectroscopy, competitive complexation liquid–liquid extraction, and ab initio molecular dynamics simulations. Two studied reagents are strong multidentate chelators, well-suited for applications seeking radiometal coordination for in-vivo delivery and f-element isolation. The previously reported H 4 octapa forms a compact coordination packet, while H 4 pypa-peg is less sterically constrained due to the presence of central pyridine ring. The solubility of H 4 octapa is limited in a non-complexing high ionic strength perchlorate media. However, the introduction of a polyethylene glycol group in H 4 pypa-peg increased the solubility without influencing its ability to complex the lanthanides and minor actinides in solution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards the stable chelation of radium for biomedical applications with an 18-membered macrocyclic ligand

Targeted alpha therapy is an emerging strategy for the treatment of disseminated cancer. [ 223 Ra]RaCl 2 is the only clinically approved alpha particle-emitting drug, and it is used to treat castrate-resistant prostate cancer bone metastases, to which [ 223 Ra]Ra 2+ localizes. To specifically direct [ 223 Ra]Ra 2+ to non-osseous disease sites, chelation and conjugation to a cancer-targeting moiety is necessary. Although previous efforts to stably chelate [223Ra]Ra2+ for this purpose have had limited success, here we report a biologically stable radiocomplex with the 18-membered macrocyclic chelator macropa. Quantitative labeling of macropa with [ 223 Ra]Ra 2+ was accomplished within 5 min at room temperature with a radiolabeling efficiency of >95%, representing a significant advancement over conventional chelators such as DOTA and EDTA, which were unable to completely complex [ 223 Ra]Ra 2+ under these conditions. [ 223 Ra][Ra(macropa)] was highly stable in human serum and exhibited dramatically reduced bone and spleen uptake in mice in comparison to bone-targeted [ 223 Ra]RaCl 2 , signifying that [ 223 Ra][Ra(macropa)] remains intact in vivo. Upon conjugation of macropa to a single amino acid b-alanine as well as to the prostate-specific membrane antigen-targeting peptide DUPA, both constructs retained high affinity for 223 Ra, complexing >95% of Ra 2+ in solution. Furthermore, [ 223 Ra][Ra(macropa-b-alanine)] was rapidly cleared from mice and showed low 223 Ra bone absorption, indicating that this conjugate is stable under biological conditions. Unexpectedly, this stability was lost upon conjugation of macropa to DUPA, which suggests a role of targeting vectors in complex stability in vivo for this system. Nonetheless, our successful demonstration of efficient radiolabeling of the b-alanine conjugate with 223 Ra and its subsequent stability in vivo establishes for the first time the possibility of delivering [ 223 Ra]Ra 2+ to metastases outside of the bone using functionalized chelators, marking a significant expansion of the therapeutic utility of this radiometal in the clinic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BeyondPlanck X. Bandpass and beam leakage corrections

We discuss the treatment of bandpass and beam leakage corrections in the Bayesian BeyondPlanck CMB analysis pipeline as applied to the Planck LFI measurements. As a preparatory step, we first apply three corrections to the nominal LFI bandpass profiles including removal of a known systematic effect in the ground measuring equipment at 61 GHz; smoothing of standing wave ripples; and edge regularization. The main net impact of these modifications is an overall shift in the 70 GHz bandpass of +0.6 GHz; we argue that any analysis of LFI data products, either from Planck or BeyondPlanck, should use these new bandpasses. In addition, we fit a single free bandpass parameter for each radiometer of the form Δ i = Δ 0 + $δ$ i , where Δ 0 represents an absolute frequency shift per frequency band and $δ$i is a relative shift per detector. The absolute correction is only fitted at 30 GHz with a full $\chi$ 2 -based likelihood, resulting in a correction of Δ 30 = 0.24 ± 0.03 GHz. The relative corrections are fitted using a spurious map approach, fundamentally similar to the method pioneered by the WMAP team, but without introducing many additional degrees of freedom. All bandpass parameters are sampled using a standard Metropolis sampler within the main BeyondPlanck Gibbs chain, and bandpass uncertainties are thus propagated to all other data products in the analysis. In total, we find that our bandpass model significantly reduces leakage effects. For beam leakage corrections, we adopt the official Planck LFI beam estimates without additional degrees of freedom, and only marginalize over the underlying sky model. We note that this is the first-time leakage from beam mismatch has been included for Planck LFI maps.

79 ASTRONOMY AND ASTROPHYSICS↗

DIII-D High Field Side Lower Hybrid Current Drive Experiment Overview

In preparation for high field side lower hybrid current drive (HFS LHCD) experiments in DIII-D, the HFS LHCD was to be commissioned and physics experiments commence once the system operated up to 300 kW for 0.5 s. The initial physics experiments sought to characterize coupling, wave propagation, and driven current measurements. In HFS LHCD first campaign, the maximum power was limited to <200 kW due to waveguide pressure leaks limiting the number of available modules and power per module. Here we summarize commissioning progress and initial physics observations. The HFS LHCD coupler was optimized for high qmin, DIII-D discharges where efficient off-axis current at r/a~0.6-0.8 is desired. The coupler n|| spectrum is peaked at 2.7 and is predicted to generate ~0.14 MA/MW coupled for 1.6 MW injected. In preparation, the HFS scrape-off layer density profile was characterized and found to have steeper profiles and lower fluctuation levels than the low field side. Furthermore, the HFS SOL density profile can be accurately predicted using global plasma quantities using machine learning. Thus far, one module has injected ~100 kW for 0.5 s with <5% reflected power. Nonthermal electrons have been observed on lower frequency channels of the electron cyclotron emission radiometer correlated with the LH power indicating core wave absorption. To avoid 30R neutral beam heat flux, a split launcher is proposed to avoid the high heat flux region while maintaining power spectrum and directivity.

Wukitch, Stephen J. [Massachusetts Inst. of Techno↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks

Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.

47 OTHER INSTRUMENTATION↗

Edge turbulence measurements in L-mode and I-mode at ASDEX Upgrade

The I-mode confinement regime is promising for future reactor operation due to high energy confinement without high particle confinement. However, the role of edge turbulence in creating I-mode's beneficial transport properties is still unknown. New measurements of edge turbulence (ρpol=0.9−1.0) in L-modes and I-modes at low and high densities at ASDEX Upgrade are presented in this paper. A high radial resolution correlation electron cyclotron emission radiometer measures the broadband turbulence throughout the L-mode and I-mode edge and pedestal. The weakly coherent mode (WCM) is measured in both L-mode and I-mode near the last closed flux surface with Te fluctuation levels of 2.3%–4.2%, with a frequency shift between the two phases related to a deeper Er well in I-mode. An neTe phase diagnostic captures a change of the WCM neTe phase between L-mode and I-mode from −171° to −143°. The thermal He beam diagnostic measures a WCM wavenumber range of −0.5 to −1.0 cm−1. A low-frequency edge oscillation (LFEO) appears in the I-mode phase of these discharges and displays coupling to the WCM, but the LFEO does not appear in the L-mode phase. Linear gyrokinetic simulations of the outer core and pedestal top turbulence indicate that while the dominant turbulent modes in the outer core are ion directed and electrostatic, the turbulence becomes increasingly electron directed and electromagnetic with increasing radius. Collisionality is not found to impact characteristics of the L-mode and I-mode edge turbulence with respect to the presence of the WCM; however, the quality of global confinement decreases with collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Pan-tropical daily L-band microwave land surface emissivity retrieval from GNSS-R observations

The uncertainties in microwave land surface emissivity (MLSE) measurements have long limited the use of spaceborne microwave radiometer data. As an emerging observation method, Global Navigation Satellite System Reflectometry (GNSS-R) has demonstrated great potential in several land and ocean applications. In this study, a method for obtaining daily MLSE dataset in the pan-tropical region from Cyclone GNSS (CYGNSS) observations is presented and evaluated. The CYGNSS observations are first aggregated into the Equal-Area-Scalable-Earth (EASE) 2.0 36 km grid by a combined weight function of distance, time, and signal-to-noise ratio variance. Then, the method employs a pixel-by-pixel regression algorithm to conduct the daily MLSE retrieval using reference emissivity derived from the Soil Moisture Active Passive (SMAP) brightness temperature. The CYGNSS MLSE shows good agreement with SMAP MLSE, delivering an overall root-mean-square error (RMSE) of 0.022 and 0.017 for horizontal and vertical polarization, respectively, during the training set spanning the whole year of 2018. Furthermore, on the test set from January 2019 to May 2019, the RMSE values amounted to 0.030 and 0.023 for horizontal and vertical polarization, respectively. Temperature records from the International Soil Moisture Network are employed to calculate the emissivity and for in-situ validation, which yield an RMSE of 0.034 and 0.026 for the two polarizations, respectively. The proposed algorithm provides an encouraging approach to obtain accurate daily MLSE dataset for microwave remote sensing. Compared to the SMAP MLSE, the CYGNSS MLSE has a remarkable improvement of 86% in temporal resolution, greatly complementing the existing microwave emissivity datasets.

54 ENVIRONMENTAL SCIENCES↗

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the divergence-free component of the polarization field, the B-mode component, reveals the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial divergence-free component of the polarization field, the B-mode, could reveal the presence of gravitational waves in the early Universe. The detection of such a component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: LSPE-Strip, a radiometer-based telescope on the ground in Tenerife-Teide observatory, and LSPE-SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2022/23 for LSPE-SWIPE, with a flight duration up to 15 days, and in Summer 2022 with two years observations for LSPE-Strip. In this work, we describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact on the performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE will reach a sensitivity in tensor-to-scalar ratio of σr < 0.01, set an upper limit r < 0.015 at 95% confidence level, and improve constraints on other cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗