Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real time analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Water quality monitor (EMPAX instrument)

The impetus of the Viking Mission to Mars led to the first miniaturization of a X-ray Fluorescence Spectrometer (XRFS). Two units were flown on the Viking Mission and successfully operated for two years analyzing the elemental composition of the Martian soil. Under a Bureau of Mines/NASA Technology Utilization project, this XRFS design was utilized to produce a battery powered, portable unit for elemental analysis of geological samples. This paper will detail design improvements and additional sampling capabilities that were incorporated into a second generation portable XRFS that was funded by the EPA/NASA Technology Utilization project. The unit, Environment Monitoring with Portable Analysis by X-ray (EMPAX), was developed specifically for quantitative determination of the need of EPA and and any industry affected by environmental concerns, the EMPAX fulfills a critical need to provide on-site, real-time analysis of toxic metal contamination. A patent was issued on EMPAX, but a commercial manufacturer is still being sought.

Kelliher, Warren C.↗

Evaluation of Neutron Detection Technology and Analysis Techniques to Support Fukushima Daiichi Decommissioning [Poster]

Decommissioning efforts and associated fuel debris retrieval from the damaged Units 1-3 require robust methods to monitor and assure subcriticality. These include adequate detection technologies capable to withstand high gamma radiation conditions within the units; as well as analysis methods capable to provide robust signatures to assure agile criticality monitoring in situation where material distribution is changing. This poster presents overview of experimental and analytical efforts focused on evaluation of neutronbased technologies and development of real-time analysis using state-of-the art capabilities available within the 1F Fuel Retrieval and Monitoring Experiments (1FRAME) project.

1FRAME↗

Analysis of SSEM Sensor Data Using BEAM

A report describes analysis of space shuttle main engine (SSME) sensor data using Beacon-based Exception Analysis for Multimissions (BEAM) [NASA Tech Briefs articles, the two most relevant being Beacon-Based Exception Analysis for Multimissions (NPO- 20827), Vol. 26, No.9 (September 2002), page 32 and Integrated Formulation of Beacon-Based Exception Analysis for Multimissions (NPO- 21126), Vol. 27, No. 3 (March 2003), page 74] for automated detection of anomalies. A specific implementation of BEAM, using the Dynamical Invariant Anomaly Detector (DIAD), is used to find anomalies commonly encountered during SSME ground test firings. The DIAD detects anomalies by computing coefficients of an autoregressive model and comparing them to expected values extracted from previous training data. The DIAD was trained using nominal SSME test-firing data. DIAD detected all the major anomalies including blade failures, frozen sense lines, and deactivated sensors. The DIAD was particularly sensitive to anomalies caused by faulty sensors and unexpected transients. The system offers a way to reduce SSME analysis time and cost by automatically indicating specific time periods, signals, and features contributing to each anomaly. The software described here executes on a standard workstation and delivers analyses in seconds, a computing time comparable to or faster than the test duration itself, offering potential for real-time analysis.

Zak, Michail↗

Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device (LHD) and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system's rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

Thomson scattering, real-time, LHD, plasma diagnos↗

High accuracy in-situ direct gas analysis of Li-ion batteries

Cycling of lithium-ion batteries containing Ni-rich NMC cathodes at high voltage involves intense gas generation. From the safety standpoint, it is critical to understand how different gas species respond to changes of upper cut-off voltages. In this manuscript, we introduce a novel experimental set up for real-time analysis of gas generation in prismatic pouch cells. In a typical experiment, a lithium-ion pouch cell is directly connected to a quadruple mass spectrometer by glass capillary. Pressure difference helps move the generated gases to the mass spectrometer column for full analysis. The gaseous species are probed during both formation cycle and aging cycles in Li-ion pouch cells comprising NMC811 cathode and graphite anode. The gases are generated upon the creation of the solid electrolyte interphase on graphite during the first formation charge. Besides ethylene gas, C 2 H 4 , whose occurrence is related to the decomposition of ethylene carbonate, a minor solvent decomposition happened at a lower voltage is demonstrated to be associated with residue water on the electrode. For aging cycles, three upper cut-off voltages have been selected to investigate the gas evolution behavior upon charging to 4.2, 4.4 and 4.6 V. Higher upper cut-off voltages do not affect the amount of O 2 measured as a part of the generated oxygen could have reacted with electrolytes. Quite similar and low amounts of O 2 remain in the cells upon charging to the selected cut-off voltages. On the other hand, the generation of CO 2 has been found to be very sensitive to upper cut-off voltage. During similar aging cycles, 6167 nmol $g_{NMC}^{-1}$ of CO 2 is generated at 4.6 V, versus 1650 nmol $g_{NMC}^{-1}$ of CO 2 at 4.4 V, versus 91 nmol $g_{NMC}^{-1}$ of CO 2 at 4.2 V.

25 ENERGY STORAGE↗

Online Electron Reconstruction at CLAS12

Online reconstruction plays a crucial role in monitoring and in real-time analysis of high energy and nuclear physics experiments. A vital aspect of reconstruction algorithms is particle identification, which combines information from various detector components to determine the type of particle. Electron identification is particularly significant in electro-production nuclear physics experiments like the CLAS12 spectrometer at Jefferson Laboratory as it is essential in data recording. A machine learning approach has been developed for CLAS12 experiments to reconstruct and identify electrons by combining raw signals from multiple detector components at the data acquisition level. This method achieves high electron identification purity while maintaining nearly 100% efficiency. Furthermore, the machine learning tools operate at rates exceeding data acquisition speed, enabling the real-time electron reconstruction. This advancement significantly improves online analyses and monitoring capabilities for CLAS12 experiments.

Tyson,, Richard [Thomas Jefferson National Acceler↗

Enhanced analysis of experimental x-ray spectra through deep learning

X-ray spectroscopic data from high-energy-density laser-produced plasmas has long required thorough, time-consuming analysis to extract meaningful source conditions. There are often confounding factors due to rapidly evolving states and finite spatial gradients (e.g., the existence of multi-temperature, multi-density, multi-ionization states, etc.) that make spectral measurements and analysis difficult. Here, in this paper, we demonstrate how deep learning can be applied to enhance x-ray spectral data analysis in both speed and intricacy. Neural networks (NNs) are trained on ensemble atomic physics simulations so that they can subsequently construct a model capable of extracting plasma parameters directly from experimental spectra. Through deep learning, the models can extract temperature distributions as opposed to single or dual temperature/density fits from standard trial-and-error atomic modeling at a significantly reduced computational cost compared to traditional trial-and-error methods. These NNs are envisioned to be deployed with high repetition rate x-ray spectrometers in order to provide detailed real-time analysis of experimental spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

Volatility Basis Set Distributions and Viscosity of Organic Aerosol Mixtures: Insights from Chemical Characterization Using Temperature-Programmed Desorption–Direct Analysis in Real-Time High-Resolution Mass Spectrometry

Quantitative assessment of gas-particle partitioning of individual components within complex atmospheric organic aerosols (OA) mixtures is critical for predicting and comprehending the formation and evolution of OA particles in the atmosphere. This investigation leverages previously documented data obtained through a temperature programmed desorption - direct analysis in real time – high resolution mass spectrometry (TPD-DART-HRMS) platform. This methodology facilitates the bottom-up construction of volatility basis set (VBS) distributions for constituents found in three biogenic secondary organic aerosol (SOA) mixtures produced through the ozonolysis of a-pinene, limonene, and ocimene. The apparent enthalpies (ΔH*, kJ mol -1 ) and saturated vapor mass concentrations (C T *, µg∙m -3 ) of individual SOA components, determined as a function of temperature (T, K), facilitated an assessment of changes in VBS distributions and gas-particle partitioning with respect to T and atmospheric total organic mass loadings (tOM, µg∙m -3 ). Further, the VBS distributions reveal distinct differences in volatilities among monomers, dimers, and trimers, enabling their categorization into separate volatility bins. At the ambient temperature of T = 298 K, only monomers efficiently partition between gas and particle phases across a broad range of atmospherically relevant total organic mass loadings (tOM) values of 1–100 µg∙m -3 . Partitioning of dimers and trimers becomes notable only at T > 360 K and T > 420 K, respectively. The viscosity of SOA mixtures is assessed using a bottom-up calculation approach, incorporating the input of elemental formulas, ΔH*, C T *, and particle-phase mass fractions of the SOA components. Through this approach, we are able to accurately estimate the variations in SOA viscosity that result from the evaporation of its components. These variations are, in turn, influenced by atmospherically relevant changes in tOM and T. Comparison of the calculated SOA viscosity and diffusivity values with literature reported experimental results shows close agreement, thereby validating the employed calculation approach. These findings underscore the significant potential for TPD-DART-HRMS measurements in enabling the untargeted analysis of organic molecules within OA mixtures. This approach facilitates quantitative assessment of their gas-particle partitioning and allows for the estimation of their viscosity and condensed-phase diffusion, thereby contributing valuable insights to atmospheric models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Radioactive 65 Zn Contamination using 3D Position Sensitive CdZnTe Detectors

SRNL NMG Goal: In collaboration with ORNL, the aim is to identify and explore innovative technology opportunities that accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, and improve worker safety and minimize program risks. • This process will include 3 glovebox systems that require personnel to dilute and package the plutonium for safe storage at WIPP. • For holdup monitoring and verification, gamma ray spectroscopy and imaging are the methods employed to achieve real time analysis of the plutonium waste. 2

Nwadeyi, Valerie E.↗

MCP-eGridGPT (MCP-Enabled Chatbot with Electrical Power System Analysis and Interactive Visualization Tool) [SWR-25-126]

This software is an advanced chatbot system that integrates the Model Context Protocol (MCP) to provide intelligent electrical power system analysis and automated visualization generation. The system enables users to interact with complex electrical engineering tools through natural language, automatically analyzes power system data for voltage violations and grid health assessment, and generates professional interactive HTML dashboards and reports. Key features include dynamic tool discovery from MCP servers, multi-LLM provider support, intelligent data interpretation using large language models, automated chart generation, and a web-based interface for real-time analysis. The software bridges sophisticated electrical engineering analysis with user-friendly interfaces, making power system diagnostics accessible through conversational AI.

Choi, Seong [National Laboratory of the Rockies (N↗

Data analysis study and performance evaluation of the scanning laser Doppler system

A simulation program which provided information on theoretically expected vortex spectra, evaluations of potential algorithms, and expected location accuracies for given scan patterns is presented. Field tests using an aircraft engine flow field and aircraft vortices during flyby tests were compared to the results of the simulation. From these studies, a vortex location algorithm was developed which provided vortex location for one or two vortices as a function of time. Results of this algorithm used on data from flyby tests were used to study vortex transport, to evaluate system performance, and to provide suggestions for real-time vortex location algorithms. The results of real-time analysis were compared to those which were expected based on theoretical considerations.

Sonnenschein, C. M.↗

Nanomechanical sampling of material for nanoscale mass spectrometry chemical analysis

The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SonicPy: a suite of programs for ultrasound pulse-echo data acquisition and analysis

Sound speed and elastic constants measurements in solids and liquids are commonly performed using the ultrasound pulse-echo technique. Recent advances have expanded the use of this technique at numerous high pressure synchrotron beamlines and offline laboratories. However, the increased experimental throughput has revealed many limitations in existing software for handling the rapid measurement and the subsequent data-reduction. Here, we report the development of a collection of computer programs for sound speed measurements using the ultrasound pulse-echo technique, compatible with stepped multi-frequency, as well as broadband-pulse, couplant-corrected methods. The programs provide a highly interactive graphical interface, enable efficient measurement, exploration and near real-time analysis of the ultrasound data, and contain features useful for working with samples under high pressure and/or high temperature. The included analysis programs can alleviate the time required for data reduction from hours to less than a minute, allowing users to make timely and informed decisions regarding the appropriate experimental parameters.

97 MATHEMATICS AND COMPUTING↗

An in Situ Technique for Elemental Analysis of Lunar Surfaces

An in situ analytical technique that can remotely determine the elemental constituents of solids has been demonstrated. Laser-Induced Breakdown Spectroscopy (LIBS) is a form of atomic emission spectroscopy in which a powerful laser pulse is focused on a solid to generate a laser spark, or microplasma. Material in the plasma is vaporized, and the resulting atoms are excited to emit light. The light is spectrally resolved to identify the emitting species. LIBS is a simple technique that can be automated for inclusion aboard a remotely operated vehicle. Since only optical access to a sample is required, areas inaccessible to a rover can be analyzed remotely. A single laser spark both vaporizes and excites the sample so that near real-time analysis (a few minutes) is possible. This technique provides simultaneous multielement detection and has good sensitivity for many elements. LIBS also eliminates the need for sample retrieval and preparation preventing possible sample contamination. These qualities make the LIBS technique uniquely suited for use in the lunar environment.

Kane, K. Y.↗

Application of a Modified Gas Chromatograph to Analyze Space Experiment Combustion Gases on Space Shuttle Mission STS-94

A space experiment designed to study the behavior of combustion without the gravitational effects of buoyancy was launched aboard the Space Shuttle Columbia on July 1, 1997. The space experiment, designated as Combustion Module-1 (CM-1), was one of several manifested on the Microgravity Sciences Laboratory - 1 (MSL-1) mission. The launch, designated STS-94, had the Spacelab Module as the payload, in which the MSL-1 experiments were conducted by the Shuttle crewmembers. CM-1 was designed to accommodate two different combustion experiments during MSL-1. One experiment, the Structure of Flame Balls at Low Lewis-number experiment (SOFBALL), required gas chromatography analysis to verify the composition of the known, premixed gases prior to combustion, and to determine the remaining reactant and the products resulting from the combustion process in microgravity. A commercial, off-the-shelf, dual-channel micro gas chromatograph was procured and modified to interface with the CM-1 Fluids Supply Package and the CM-1 Combustion Chamber, to accommodate two different carrier gases, each flowing through its own independent column module, to withstand the launch environment of the Space Shuttle, to accept Spacelab electrical power, and to meet the Spacelab flight requirements for electromagnetic interference (EMI) and offgassing. The GC data was down linked to the Marshall Space Flight Center for near-real time analysis, and stored on-orbit for post-flight analysis. The gas chromatograph operated successfully during the entire SOFBALL experiment and collected 309 runs. Because of the constraints imposed upon the gas chromatograph by the CM-1 hardware, system and operations, it was unable to measure the gases to the required accuracy. Future improvements to the system for a re-flight of the SOFBALL experiment are expected to enable the gas chromatograph to meet all the requirements.

Coho, William K.↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗