Service area size assessment for evaluating the spatial scale of solid waste recovery chains: A territorial perspective

Highlights: • A model to evaluate the service area size of a waste recovery chain is proposed. • A recovery performance score is given per waste source. •The areas to be collected in priority are the sources with the highest score. • The score depends on the source's characteristics and the recovery technology. •Replacing anaerobic digestion by composting decreases the facility's spatial scale. - Abstract: Waste recovery is an integrated part of municipal solid waste management systems but its strategic planning is still challenging. In particular, the service area size of facilities is a sensitive issue since its calculation depends on various factors related to treatment technologies (output products) and territorial features (sources waste production and location). This work presents a systemic approach for the estimation of a chain's service area size, based on a balance between costs and recovery profits. The model assigns a recovery performance value to each source, which can be positive, neutral or negative. If it is positive, the source should be included in the facility's service area. Applied to the case of Montreal for food waste recovery by anaerobic digestion, the approach showed that at most 23 out of the 30 districts should be included in the service area, depending on the indicator, which represents around 127,000 t of waste recovered/year. Due to the systemic approach, these districts were not necessarily the closest to the facility. Moreover, for the Montreal case, changing the facility's location did not have a great influence on the optimal service area size, showing that the distance to the facility was not a decisive factor at this scale. However, replacing anaerobic digestion by a composting plant reduced the break-even transport distances and, thus, the number of sources worth collecting (around 68,500 t/year). In this way, the methodology, applied to different management strategies, gave a sense of the spatial dynamics involved in the recovery chain's design. The map of optimal supply obtained could be used to further analyse the feasibility of multi-site and/or multi-technology systems for the territory considered.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DNA damage checkpoint recovery and cancer development

Cell cycle checkpoints were initially presumed to function as a regulator of cell cycle machinery in response to different genotoxic stresses, and later found to play an important role in the process of tumorigenesis by acting as a guard against DNA over-replication. As a counterpart of checkpoint activation, the checkpoint recovery machinery is working in opposition, aiming to reverse the checkpoint activation and resume the normal cell cycle. The DNA damage response (DDR) and oncogene induced senescence (OIS) are frequently found in precancerous lesions, and believed to constitute a barrier to tumorigenesis, however, the DDR and OIS have been observed to be diminished in advanced cancers of most tissue origins. These findings suggest that when progressing from pre-neoplastic lesions to cancer, DNA damage checkpoint barriers are overridden. How the DDR checkpoint is bypassed in this process remains largely unknown. Activated cytokine and growth factor-signaling pathways were very recently shown to suppress the DDR and to promote uncontrolled cell proliferation in the context of oncovirus infection. In recent decades, data from cell line and tumor models showed that a group of checkpoint recovery proteins function in promoting tumor progression; data from patient samples also showed overexpression of checkpoint recovery proteins in human cancer tissues and a correlation with patients' poor prognosis. In this review, the known cell cycle checkpoint recovery proteins and their roles in DNA damage checkpoint recovery are reviewed, as well as their implications in cancer development. This review also provides insight into the mechanism by which the DDR suppresses oncogene-driven tumorigenesis and tumor progression. - Highlights: • DNA damage checkpoint works as a barrier to cancer initiation. • DDR machinary response to genotoxic and oncogenic stress in similar way. • Checkpoint recovery pathways provide active signaling in cell cycle control. • Checkpoint recovery pathway plays a role in overriding tumor barrier in tumorigenesis. • Recovery protein dysregulation and human cancer development is correlated.

60 APPLIED LIFE SCIENCES↗

Monte Carlo-based Transmission and Subtransmission Recovery Simulation of Hurricanes

High-impact low-probability (HILP) events can wreak havoc on electric power systems without appropriate preparedness. In this paper, the recent development of a tool, named Recovery Simulator and Analysis (RSA), is described and demonstrated. While there are many issues to consider when recovering electric power systems, the focus of RSA is on the coordination of transmission and subtransmission recovery with generation dispatch to minimize unserved energy. RSA focuses on recovery simulation to evaluate resilience as part of a planning process. RSA is demonstrated on an approximately 1400-bus Puerto Rican power system for 100 simulated instances of Hurricane Maria. Analysis of the recovery determines how many lines are critical to the recovery and which loads may experience delayed recovery. The results demonstrate the potential uses of RSA for identifying recovery decisions with low unserved energy and for identifying assets critical to recovery which can then be hardened prior to a HILP event.

Maloney, Patrick R.↗

90 Sr Liquid Scintillation Urine Analysis Utilizing Different Approaches for Tracer Recovery

90 Sr is one of the isotopes most commonly produced by nuclear fission. This medium lived isotope presents serious challenges to radiation workers, the environment, and following a nuclear event, the general public. Methods of identifying this nuclide have been in existence for a number of years (e.g. Horwitz, E.P. [1], Maxwell, S.L.[2], EPA 905.0 [3]) which are time consuming, requiring a month or more for full analysis. This time frame is unacceptable in the present security environment. It is therefore important to have a dependable and rapid method for the determination of Sr. The purposes of this study are to reduce analysis time to less than half a day by utilizing a single method of radiation measurement while continuing to yield precise results. This paper presents findings on three methods that can meet this criteria; (1) stable Sr carrier, (2) 85 Sr by gamma spectroscopy, and (3) 85 Sr by LSC. Two methods of analyzing and calculating the 85 Sr tracer recovery were investigated (gamma spectroscopy and a low energy window-Sr85LEBAB by LSC) as well as the use of two different types of Sr tracer ( 85 Sr and stable Sr carrier). Three separate stock blank urine samples were spiked with various activity levels of 239 Pu, 137 Cs, 90 Sr / 90 Y to determine the effectiveness of the Eichrome Sr-spec™ resin 2mL extractive columns. The objective was to compare the recoveries of 85 Sr versus a stable strontium carrier, attempt to compare the rate at which samples can be processed by evaluating evaporation, neutralization, and removing the use of another instrument (gamma spectrometer) by using the LSC spectrometer to obtain 85 Sr recovery. It was found that when using a calibration curve comprised of a different cocktail and a non-optimum discriminator setting reasonable results (bias of ± 25%) were achieved. The results from spiked samples containing 85 Sr demonstrated that a higher recovery is obtained when using gamma spectroscopy (89-95%) than when using the LEB window from LSC (120-470%). The high recovery for 85 Sr by LSC analysis may be due to the interference/cross talk from the alpha region since alpha counts were observed in all sample sets. After further investigation it was determined that the alpha counts were due to 239 Pu breakthrough on the Sr-spec™ column. This requires further development to purify the Sr before an accurate tracer recovery determination can be made. Sample preparation times varied and ranged from 4-6 hours depending on the specific sample preparation process. The results from the spiked samples containing stable strontium nitrate Sr(NO 3 ) 2 carrier demonstrate that gravimetric analysis yields the most consistent high recoveries (97-101%) when evaporation is carefully performed. Since this method did not have a variation on the tracer recovery method, the samples were counted in 1) LEB/Alpha/Beta mode optimized for Sr-90, 2) DPM for Sr-90, and 3) general LEB/Alpha/Beta mode. The results (from the known) ranged from 79-104%, 107-177%, and 85-89% for 1, 2, and 3 respectively. Counting the prepared samples in a generic low energy beta/alpha/beta protocol yielded more accurate and consistent results and also yielded the shortest sample preparation turn-around-time of 3.5 hours.

Piraner, Olga↗

Preliminary Audit Report on "Management Controls over the Commonwealth of Virginia's Efforts to Implement the American Recovery and Reinvestment Act Weatherization Assistance Program"

The Department of Energy's (Department) Weatherization Assistance Program received $5 billion under the American Recovery and Reinvestment Act of 2009 (Recovery Act) to improve the energy efficiency of homes, multi-family rental units and mobile homes owned or occupied by low-income persons. Subsequently, the Department awarded a three-year Weatherization Assistance Program grant for $94 million to the Commonwealth of Virginia (Virginia). This grant provided more than a ten-fold increase in funds available to Virginia for weatherization over that authorized in Fiscal Year (FY) 2009. Corresponding to the increase in funding, the Recovery Act increased the limit on the average amount spent to weatherize a home (unit) from $2,500 to $6,500. Virginia's Department of Housing and Community Development (DHCD) administers the Recovery Act grant through 22 local community action agencies. These agencies (sub-grantees) are responsible for determining applicant eligibility, weatherizing homes, and conducting home assessments and inspections. Typical weatherization services include installing insulation; sealing ducts; tuning and repairing furnaces; and, mitigating heat loss through windows, doors and other infiltration points. Virginia plans to use its Recovery Act Weatherization funding to weatherize about 9,193 units over the life of the grant - a significant increase over the 1,475 housing units that were planned to be completed in FY 2009. Given the significant increase in funding and the demands associated with weatherizing thousands of homes, we initiated this audit to determine if Virginia had adequate safeguards in place to ensure that the Weatherization Program was managed efficiently and effectively. The State of Virginia's DHCD had not implemented financial and reporting controls needed to ensure Weatherization Program funds are spent effectively and efficiently. Specifically, DHCD had not: (1) Performed on-site financial monitoring of any of its sub-grantees under the Recovery Act; (2) Reviewed documentation supporting sub-grantee requests for reimbursements to verify the accuracy of amounts charged; (3) Periodically reconciled amounts paid to sub-grantees to the actual cost to weatherize units; (4) Maintained vehicle and equipment inventories as required by Federal regulations and state and Federal program directives; and (5) Accurately reported Weatherization Program results to the Department. Exacerbating weaknesses in DHCD's financial controls, the Department's most recent program monitoring visit to Virginia, made in 2008 before passage of the Recovery Act, did not include a required financial review. Hence, the financial control weaknesses discussed above were not detected and had not been addressed. As described in this report, these control and reporting weaknesses increase the risk that Recovery Act objectives may not be achieved and that fraud, waste or abuse can occur and not be detected in this critically important program.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An LCA model for waste incineration enhanced with new technologies for metal recovery and application to the case of Switzerland

Highlights: • An enhanced process-based LCA model for MSWI is featured and applied in case study. • LCA modeling of recent technological developments for metal recovery from fly ash. • Net release from Swiss MSWI 133 kg CO{sub 2}-eq/tonne waste from attributional LCA perspective. • Net savings from a consequential LCA perspective reach up to 303 kg CO{sub 2}-eq/tonne waste. • Impacts according to ReCiPe and CExD show similar pattern to climate change. - Abstract: A process model of municipal solid waste incinerators (MSWIs) and new technologies for metal recovery from combustion residues was developed. The environmental impact is modeled as a function of waste composition as well as waste treatment and material recovery technologies. The model includes combustion with a grate incinerator, several flue gas treatment technologies, electricity and steam production from waste heat recovery, metal recovery from slag and fly ash, and landfilling of residues and can be tailored to specific plants and sites (software tools can be downloaded free of charge). Application of the model to Switzerland shows that the treatment of one tonne of municipal solid waste results on average in 425 kg CO{sub 2}-eq. generated in the incineration process, and 54 kg CO{sub 2}-eq. accrue in upstream processes such as waste transport and the production of operating materials. Downstream processes, i.e. residue disposal, generates 5 kg CO{sub 2}-eq. Savings from energy recovery are in the range of 67 to 752 kg CO{sub 2}-eq. depending on the assumptions regarding the substituted energy production, while the recovery of metals from slag and fly ash currently results in a net saving of approximately 35 kg CO{sub 2}-eq. A similar impact pattern is observed when assessing the MSWI model for aggregated environmental impacts (ReCiPe) and for non-renewable resource consumption (cumulative exergy demand), except that direct emissions have less and no relevance, respectively, on the total score. The study illustrates that MSWI plants can be an important element of industrial ecology as they provide waste disposal services and can help to close material and energetic cycles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evidence of Polarization‐Type Potential‐Induced Degradation (PID‐p) in the Field and Investigation of the Recovery Mechanism on Bifacial p ‐PERC Modules

This study investigates the polarization-type potential-induced degradation (PID-p) of bifacial glass/glass p-type passivated emitter rear contact (p-PERC) modules in the field and their recovery behavior. Modules were installed with three mounting configurations providing different albedo conditions. System voltage (–600, –1500, and +1500 V) was applied to the cell circuits, with respect to the grounded module frames. No degradation was observed for positively biased modules, but PID-p was identified on the rear side when cells are negatively biased, with maximum power dropping during the first days and stabilizing at values up to 8% loss. Electroluminescence images revealed a variation of the cells' PID-p susceptibility within a module. Three parameters were shown to impact the degradation rate: rear albedo light, voltage, and wetness conditions. Degraded modules were recovered either by (1) a positive bias (+1500 V), (2) outdoor illumination with the front side facing sun, (3) outdoor illumination with the rear side facing sun, or (4) dark storage. A recovery pattern was identified with I–V parameters decreasing to a local minimum before increasing to full recovery. The proposed mechanism is based on the band bending at the rear p-type Si/AlO x/SiN x interface, going from inversion to depletion and accumulation states. Full recovery was achieved in 2–7 h for the modules recovered with the rear side facing sun, four to eight nights for the modules positively biased at night, and 10–20 days for the modules with the front side facing sun. Dark storage showed slower recovery rates as I–V parameters were not improving even after 1 month. Here, the recovery rates were correlated with the net Coulombs transferred during the preceding PID stress: When more Coulombs are transferred during the degradation, the extent of degradation is greater, leading to slower recovery rates.

14 SOLAR ENERGY↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

Simultaneous recovery of vanadium and nickel from power plant fly-ash: Optimization of parameters using response surface methodology

Highlights: • Leaching of vanadium and nickel from fly ash (14.43% V and 5.19% Ni) in sulfuric acid was performed. • Optimization of leaching parameters was carried out using a response surface methodology. • Using optimum conditions, 94.28% V and 81.01% Ni “actual recovery” was obtained. - Abstract: Simultaneous recovery of vanadium (V) and nickel (Ni), which are classified as two of the most hazardous metal species from power plant heavy fuel fly-ash, was studied using a hydrometallurgical process consisting of acid leaching using sulfuric acid. Leaching parameters were investigated and optimized in order to maximize the recovery of both vanadium and nickel. The independent leaching parameters investigated were liquid to solid ratio (S/L) (5–12.5 wt.%), temperature (45–80 °C), sulfuric acid concentration (5–25 v/v%) and leaching time (1–5 h). Response surface methodology (RSM) was used to optimize the process parameters. The most effective parameter on the recovery of both elements was found to be temperature and the least effective was time for V and acid concentration for Ni. Based on the results, optimum condition for metals recovery (actual recovery of ca.94% for V and 81% for Ni) was determined to be solid to liquid ratio of 9.15 wt.%, temperature of 80 °C, sulfuric acid concentration of 19.47 v/v% and leaching time of 2 h. The maximum V and Ni predicted recovery of 91.34% and 80.26% was achieved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrochemical Recovery of Rare-Earth Elements from Coal Fly Ash Using Ionic Liquids as both Extractant and Electrolyte

Rare-earth elements (REEs) are critical for medical technologies, electronics, and clean energy. Coal fly ash (CFA), a byproduct of coal combustion, offers a promising alternative REE source. However, efficient extraction and separation of REEs from CFA remain challenging due to the complex composition of CFA. This study introduces a sustainable method for REE recovery using a recyclable ionic liquid, betainium bis(trifluoromethylsulfonyl)imide ([Hbet]- [Tf 2 N]), which serves both as the extractant from CFA and as the electrolyte in electrodeposition. In the first stage, [Hbet][Tf 2 N] preferentially extracts REEs from CFA through leaching. In the second stage, the REE-enriched ionic liquid undergoes electrochemical deposition using amperometry techniques, where REEs are reduced and deposited onto the electrode. The deposition experiments were conducted from −0.5 to −2.0 V vs a Pt quasireference electrode in a three-electrode setup comprising titanium as the working electrode and platinum as both the reference and counter electrodes. Varying the applied potential enabled potential-dependent preferential REE deposition. At −0.5 V, neodymium (Nd) showed preferential recovery, reaching 25% with a separation factor of 37 over other REEs. In contrast, applying a more negative potential increased overall deposition, yielding ∼50% Nd recovery and 10−20% recovery for the remaining REEs. After recovery, the ionic liquid was regenerated and reused for a subsequent electrochemical recovery cycle. Overall, this study demonstrates a feasible approach for REE recovery from CFA waste, with potential to enhance resource utilization within the REE supply chain.

coal fly ash↗

Resolution recovery for Compton camera using origin ensemble algorithm

Purpose: Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. Methods: To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Results: Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2–3 orders of magnitude per iteration. Conclusions: The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.

60 APPLIED LIFE SCIENCES↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Rapid recovery of invasive wild pig (Sus scrofa) populations following density reduction

Abstract Trapping is an effective strategy for control of invasive wild pig (Sus scrofa), but eradication of populations via trapping alone typically is impractical throughout much of the species’ introduced range. Consequently, recovery of wild pig populations to pre-trapping levels following control is a major impediment to success of long-term control. In this study, we conducted camera-trap surveys to monitor recovery of two wild pig populations immediately following density reductions achieved via trapping on two sites on the Savannah River Site, SC. We used spatial capture-recapture models to estimate wild pig density during seven 3 week periods spanning 12 months to: (1) determine the time required for populations to recover to pre-trapping levels; and (2) evaluate trends in population growth, density, and distribution during recovery. Recovery of both wild pig populations started immediately after trapping ceased, with populations reaching pre-trapping levels in 3 and 5 months. Threeweek population growth rates for each wild pig population during recovery averaged 1.28 (range = 1.11–1.39 on site 1) and 1.24 (range = 0.64–1.92 on site 2), which corresponded to a 345% and 132% increase in abundance (an increase of 141 and 126 individual wild pigs on site 1 and 2, respectively) of each population by the last survey period. Rapid recovery and growth beyond pre-trapping levels of wild pig populations likely were driven by residual wild pigs not removed by trapping and compensatory reproduction and immigration. Our study is one of the first to provide information on how quickly wild pig populations can recover following overall density reductions of 54–68% and indicates practitioners should be prepared to reinitiate trapping efforts in as little as 3 months to prevent recovery of wild pig populations following control.

Biodiversity & Conservation↗

Downregulation of exocyst Sec10 accelerates kidney tubule cell recovery through enhanced cell migration

Highlights: • Exocyst Sec10 decreases by I/R injury and restores with functional recovery. • Sec10 inversely regulates kidney tubule cell wound healing after scratch injury. • Sec10 inversely regulates ruffle formation at the leading edge during recovery. • Upregulation of Sec10 increases DGKγ expression at the leading edge during recovery. • DGK inhibitor reversed Sec10-mediated ruffle formation and wound healing defect. Migration of surviving kidney tubule cells after sub-lethal injury, for example ischemia/reperfusion (I/R), plays a critical role in recovery. Exocytosis is known to be involved in cell migration, and a key component in exocytosis is the highly-conserved eight-protein exocyst complex. We investigated the expression of a central exocyst complex member, Sec10, in kidneys following I/R injury, as well as the role of Sec10 in wound healing following scratch injury of cultured Madin-Darby canine kidney (MDCK) cells. Sec10 overexpression and knockdown (KD) in MDCK cells were used to investigate the speed of wound healing and the mechanisms underlying recovery. In mice, Sec10 decreased after I/R injury, and increased during the recovery period. In cell culture, Sec10 OE inhibited ruffle formation and wound healing, while Sec10 KD accelerated it. Sec10 OE cells had higher amounts of diacylglycerol kinase (DGK) gamma at the leading edge than did control cells. A DGK inhibitor reversed the inhibition of wound healing and ruffle formation in Sec10 OE cells. Conclusively, downregulation of Sec10 following I/R injury appears to accelerate recovery of kidney tubule cells through activated ruffle formation and enhanced cell migration.

60 APPLIED LIFE SCIENCES↗

Recovery from slow inactivation in K + channels is controlled by water molecules

Application of a specific stimulus opens the intracellular gate of a K + channel (activation), yielding a transient period of ion conduction until the selectivity filter spontaneously undergoes a conformational change towards a non-conductive state (inactivation). Removal of the stimulus closes the gate and allows the selectivity filter to interconvert back to its conductive conformation (recovery). Given that the structural differences between the conductive and inactivated filter are very small, it is unclear why the recovery process can take up to several seconds. The bacterial K + channel KcsA from Streptomyces lividans can be used to help elucidate questions about channel inactivation and recovery at the atomic level. Although KcsA contains only a pore domain, without voltage-sensing machinery, it has the structural elements necessary for ion conduction, activation and inactivation. In this paper we reveal, by means of a series of long molecular dynamics simulations, how the selectivity filter is sterically locked in the inactive conformation by buried water molecules bound behind the selectivity filter. Potential of mean force calculations show how the recovery process is affected by the buried water molecules and the rebinding of an external K + ion. A kinetic model deduced from the simulations shows how releasing the buried water molecules can stretch the timescale of recovery to seconds. This leads to the prediction that reducing the occupancy of the buried water molecules by imposing a high osmotic stress should accelerate the rate of recovery, which was verified experimentally by measuring the recovery rate in the presence of a 2-molar sucrose concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The kinetics of static recovery by dislocation climb

Abstract The initial microstructure of a wide range of structural materials is conditioned by thermo-mechanical treatments such as hot-working, tempering, or solution annealing. At the elevated temperatures associated with these treatments the dislocation microstructure evolves, usually decreasing in density through a process known as static recovery. Despite its technological relevance, static recovery is not fully characterized from a theoretical standpoint, with even the controlling mechanisms subject to debate. In this study, a climb-enabled discrete dislocation dynamics (DDD) capability is leveraged to explore the kinetics of static recovery in pure Fe when controlled by dislocation climb. Quantitative data from these simulations is used to develop a revised static recovery law, and provides the parameters appropriate for predictive microstructure models in Fe. This law differs from previous analytical derivations invoking climb of dislocations, following the logarithmic trends typical of experimental observations where prior work did not. Direct comparison between the recovery law derived from DDD to experimental recovery data in alpha Fe shows strong agreement across a range of temperatures, and suggests that climb is the controlling mechanism for static recovery in pure metals.

36 MATERIALS SCIENCE↗

Photoinduced structural recovery dynamics of rare-earth nickelate thin films

Photoinduced structural dynamics of rare-earth nickelate thin films, NdNiO 3 and SmNiO 3 , grown on (001) oriented SrTiO 3 were studied using time-resolved x-ray diffraction. The evolution of the (002) Bragg peak was tracked following laser excitation. The recovery pathways were found to be strongly dependent on laser fluence for NdNiO 3 and distinct for the two rare-earth nickelates. The recovery of the (002) peak shifts was modeled using a one-dimensional thermal diffusion model which showed that the recovery processes are non-thermal at high fluences. For NdNiO 3 , the timescales for the recovery of the (002) peak shift were found to be closely related to Ni magnetism recovery, potentially indicating magneto-structural coupling. Moreover, the evolution of integrated intensity and full-width-half-maximum points towards the presence of a structural phase separation during recovery. In conclusion, our studies highlight structural recovery pathways in nickelates by comparing the distinct responses of the photoinduced metal-insulator transition in NdNiO 3 and SmNiO 3 .

36 MATERIALS SCIENCE↗

Battleground Energy Recovery Project

In October 2009, the project partners began a 36-month effort to develop an innovative, commercial-scale demonstration project incorporating state-of-the-art waste heat recovery technology at Clean Harbors, Inc., a large hazardous waste incinerator site located in Deer Park, Texas. With financial support provided by the U.S. Department of Energy, the Battleground Energy Recovery Project was launched to advance waste heat recovery solutions into the hazardous waste incineration market, an area that has seen little adoption of heat recovery in the United States. The goal of the project was to accelerate the use of energy-efficient, waste heat recovery technology as an alternative means to produce steam for industrial processes. The project had three main engineering and business objectives: Prove Feasibility of Waste Heat Recovery Technology at a Hazardous Waste Incinerator Complex; Provide Low-cost Steam to a Major Polypropylene Plant Using Waste Heat; and Create a Showcase Waste Heat Recovery Demonstration Project.