Performance of NOAA-20 VIIRS Solar Diffuser and Solar Diffuser Stability Monitor

Visible Infrared Imaging Radiometer Suite (VIIRS) radiometrically calibrates its reflective solar bands (RSBs) primarily through a sunlit onboard solar diffuser (SD). The sunlit SD provides a known radiance under the condition that the absolute product of the SD screen transmittance and the bidirectional reflectance distribution function (BRDF) along the SD-to-telescope direction is accurately known. The BRDF changes due to solar exposure. The change, referred to as the H-factor, is monitored by the onboard SD stability monitor (SDSM). The accuracy of the retrieved H-factor propagates to the retrieved F-factor which corrects the scene spectral radiance. High accuracy of the retrieved H-factor relies on high accuracies in the SDSM screen relative effective transmittance and the relative product of the SD screen effective transmittance and the BRDF at the mission start, and a high SDSM detector signal-to-noise ratio (SNR). This article briefly reviews the algorithms used for the NOAA-20 (N20) VIIRS RSB on-orbit radiometric calibration. Additionally, we show the performance of the N20 VIIRS SDSM, giving the SDSM detector SNRs and the SDSM detector gain temporal changes. We develop a model for the SNRs. The model shows that the decreased SNRs in time are due to the detector gain decreases. We also show the N20 VIIRS SD on-orbit performance, measured by the retrieved H-factor and the estimated standard deviation of its error. The H-factor for the telescope view is obtained from the H-factor for the SDSM view, multiplied by an H-factor angular dependence term. We use an innovative method to determine the angular dependence, using the dependence obtained for the Suomi National Polar-orbiting Partnership (SNPP) VIIRS.

VIIRS↗

Characterization of MODIS and SeaWiFS Solar Diffuser On-Orbit Degradation

MODIS has 20 reflective solar bands (RSB), covering the VIS, NIR, and SWIR spectral regions. They are calibrated on-orbit using a solar diffuser (SD) panel, made of space-grade Spectralon. The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor reference to the NIST reflectance standard. Its on-orbit degradation is tracked by an on-board solar diffuser stability monitor (SDSM). The SeaWifS on-orbit calibration strategy uses monthly lunar observations to monitor the long-term radiometric stability of the instrument and applies daily observations of its solar diffuser (an aluminum plate coated with YB71 paint) to track the short-term changes in the instrument response. This paper provides an overview of MODIS and SeaWiFS SD observations, applications, and approaches used to track their on-orbit degradations. Results from sensors are presented with emphasis on the spectral dependence and temporal trends of the SD degradation. Lessons and challenges from the use of SD for sensor on-orbit calibration are also discussed.

Xiong, X.↗

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent↗

BRDF Characterization and Calibration Inter-Comparison between Terra MODIS, Aqua MODIS, and S-NPP VIIRS

The inter-comparison of reflective solar bands (RSB) between Terra MODIS, Aqua MODIS, and SNPP VIIRS is very important for assessment of each instrument's calibration and to identify calibration improvements. One of the limitations of using their ground observations for the assessment is a lack of the simultaneous nadir overpasses (SNOs) over selected pseudo-invariant targets. In addition, their measurements over a selected Earth view target have significant difference in solar and view angles, and these differences magnify the effects of Bidirectional Reflectance Distribution Function (BRDF). In this work, an inter-comparison technique using a semi-empirical BRDF model is developed for reflectance correction. BRDF characterization requires a broad coverage of solar and view angles in the measurements over selected pseudo-invariant targets. Reflectance measurements over Libya 1, 2, and 4 desert sites from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for the calibration difference between the two instruments. The BRDF coefficients for three desert sites for MODIS bands 1 to 9 are derived and the wavelength dependencies are presented. The analysis and inter-comparison are for MODIS bands 1 to 9 and VIIRS moderate resolution radiometric bands (M bands) M1, M2, M4, M5, M7, M8, M10 and imaging bands (I bands) I1-I3. Results show that the ratios from different sites are in good agreement. The ratios between Terra and Aqua MODIS from year 2003 to 2014 are presented. The inter-comparison between MODIS and VIIRS are analyzed for year 2014.

Chang, Tiejun↗

On-Orbit Performance of MODIS On-Board Calibrators

The Terra MODIS (Moderate Resolution Imaging Spectroradiometer) was launched on December 18, 1999 and acquired the first scene data on February 24, 2000. It has 36 spectral bands covering spectral range from 0.41 to 14.2 microns and provides spatial resolutions of 250 (2 bands), 500 (5 bands), and 1000 m at Nadir. The instrument on-orbit calibration and characterization are determined and monitored through the use of a number of on-board calibrators (OBC). Radiometric calibration for the reflective solar bands (B1-B19, B26), from VIS (visible) to SWIR (short wavelength infrared) (0.41 to 2.1 microns), uses a Spectralon (tm) solar diffuser (SD) and a solar diffuser stability monitor (SDSM). For the thermal emissive bands (B20-B25, B27-B36), from MWIR (medium wavelength infrared) to LWIR (long wavelength infrared) (3.75 to 14.2 micron), a V-grooved flat panel blackbody is used. The instrument spectral for the VIS to SWIR bands and spatial co-registration characterizations for all bands are monitored on-orbit by the spectral radiometric calibration assembly (SRCA). In this report, we discuss the application and performance of the key MODIS on-board calibrators and their impacts on the instrument system calibration and characterization.

Xiong, X.↗

Characterization of MODIS Solar Diffuser On-Orbit Degradation

MODIS reflective solar bands (RSB) are calibrated using a solar diffuser (SD). The SD on-orbit degradation is determined by a solar diffuser stability monitor (SDSM) at 9 wavelengths from 0.41 to 0.94 microns via alternate observations of its sunlight reflected from the SD (SD view) and direct sunlight through an attenuation screen (Sun view). For each SDSM detector, a time series of ratios of its SD view to its Sun view responses tracks on-orbit changes in the SD bidirectional reflectance factor (BRF) at its wavelength. Due to an SDSM component design error, however, there exist large ripples in its Sun view responses, which have made it extremely difficult to use the original ratio approach for accurate characterization of SD on-orbit degradation. In order to mitigate the impact due to unexpected ripples, MODIS Characterization Support Team (MCST) developed a normalization approach. It relies on the fact that all SDSM detectors (D1 to D9) experience similar ripples and assumes that the SD degradation at its D9 wavelength (0.94 micron) is extremely small and can be ignored. As mission continues, the normalization approach becomes inadequate since the accumulated SD degradation at 0.94[tm can no longer be ignored. This paper presents a new approach to further improve on-orbit characterization of SD degradation. It uses a took-up table (LUT) with parameters derived from D9 observations made over a short period. Compared to other approaches, this approach can significantly reduce the impact due to ripples and that due to accumulated SD degradation at the reference detector wavelength.

Xiong, X.↗

Assessment of VIIRS Day-Night Band High Gain Calibration Using Stars

The VIIRS has a unique spectral band that can sense reflected light from space during both day and nighttime, thus referred to as the day-night band (DNB). This band operates in three different gain stages: low, mid, and high gain (LG, MG, and HG) that cover a remarkable dynamic range with its HG stage being extremely sensitive to low-light scenes. Similar to its reflective solar bands, the VIIRS uses an on-board solar diffuser for its DNB LG stage calibration, whereas the DNB MG and HG calibrations are performed using relative or ratioing approaches. In this paper, we provide an assessment of VIIRS DNB HG calibrations using stars that appear in the field-of-view of its space view (SV), focusing on the computation of the gain trending and associated tool development. We also describe various strategies and procedures developed for DNB HG calibration stability monitoring and inter-comparisons among different VIIRS instruments and discuss some of the complications and limits to this approach, including under-sampling of the stellar image, saturation, and crowding. For S-NPP VIIRS, it includes the use of the modulated relative spectral response (RSR) resulting from wavelength-dependent degradation of the sensor optics. Results show that the star-based response trending for the DNB HG is consistent with that derived from on-board solar diffuser and that the calibration difference between S-NPP and N-20 VIIRS DNB requires additional effort to address, especially for research studies and applications using data from both sensors.

VIIRS↗

S-NPP and N20 VIIRS RSB Bands Detector-to-Detector Calibration Differences Assessment Using a Homogeneous Ground Target

The S-NPP and N20 satellites have successfully operated since their launches on October 28, 2011 and November 18, 2017, respectively. This paper provides an assessment of the detector calibration stability for the reflective solar bands (RSBs) observed from both S-NPP and N20 VIIRS. Top-of-atmosphere radiances from near-nadir observations over the homogeneous Libya 4 desert site are extracted from the S-NPP VIIRS Collection 1 and N20 Collection 2 Level-1B products. The radiances from individual detectors per Half‐angle Mirror side are studied. The comparisons of the normalized radiance to all detector average values indicate that the detector calibration differences are wavelength dependent. The S-NPP detector differences have been slowly increasing in the past 8.5 years and bands M1-M4 have 1.3%- 2.2% detector differences in 2019. N20 detector differences are stable and small in the past two years except SWIR M bands. N20 M10 and M11 have 1.3% and 2.1% detector differences, respectively. S-NPP DNB detector differences are about 0.8% and N20 DNB detector differences are about 0.5%. Most bands HAM side differences are less than 0.25% in the past years except N20 VIIRS M1 HAM side differences are 0.57% in 2018 and 0.54% in 2019. The Libya 4 images have small but noticeable striping in S-NPP M1-M4 data as well as in N20 M1, M8, M10, and M11 data. These study results have been applied in the S-NPP Collection 2 new algorithm to remove the detector differences. This research help scientists and VIIRS users better understand detector calibration differences in different version VIIRS products.

Libya 4↗

Updates of Moderate Resolution Imaging Spectroradiometer On-Orbit Calibration Uncertainty Assessments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments have successfully operated for more than 18 and 16 years, respectively, on-board the NASA’s Earth Observing System Terra and Aqua spacecraft. Both Terra and Aqua MODIS have significantly contributed to the advance of global Earth remote sensing applications with a broad range of science products that have been continuously produced since the beginning of each mission and freely distributed to users worldwide. MODIS collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB), covering wavelengths from 0.41 to 14.4 μm. Its level 1B (L1B) data products, which provide the input for the MODIS high-level science products, include the top of the atmosphere reflectance factors for the RSB, radiances for both the RSB and TEB, and associated uncertainty indices (UI) at a pixel-by-pixel level. This paper provides a brief review of MODIS L1B calibration algorithms, including a number of improvements made in recent years. It presents an update of sensor calibration uncertainty assessments with a focus on several new contributors resulting from on-orbit changes in sensor characteristics, approaches developed to address these changes, and the impact due to on-orbit changes on the L1B data quality. Also discussed are remaining challenges and potential improvements to be made to continuously maintain sensor calibration and data quality, particularly those related to the quality of MODIS L1B uncertainty.

Spectroradiometer↗

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun↗

Initial Determination of the NOAA-20 VIIRS Screen Transmittances with Both Yaw Maneuver and Regular on Orbit Data

One of the scientific instruments aboard the NOAA-20 satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS regularly performs on-orbit radiometric calibration of its reflective solar bands, primarily through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD bidirectional reflectance distribution function (BRDF), denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). The eight SDSM detectors observe the sun through another attenuation screen (the SDSM screen) and the sunlit SD almost at the same time to measures the SD BRDF change. The products of the SD screen transmittance and the BRDF at t=0 and the SDSM screen transmittance were measured prelaunch. Large undulations in the H-factor were seen when using the prelaunch screen transmittances. Fifteen on-orbit yaw maneuvers were performed to validate and to further characterize the screens. Although significantly improved, the H-factor from the yaw maneuver data determined screen transmittance still has undulations as large as about 0.7-0.8%, revealing that the angular step size of the yaw maneuvers is too large. In this paper, we add regular on-orbit data to the yaw maneuver data to further improve the relative products and the relative SDSM screen transmittance. The H-factor time series derived from the newly determined screen transmittance is much smoother than that derived from using only the yaw maneuver data and thus improves considerably the radiometric calibration accuracy.

Lei, Ning↗

MODIS On-orbit Calibration: Key Issues and Approaches

MODIS, one of the key instruments for the NASA's Earth Observing System (EOS), is currently operating on both the Terra and Aqua spacecraft making continuous observations in 36 spectral bands from 0.4 to 14.4 micrometers. A complete suite of on-board calibrators (OBC) have been designed for the instruments' on-orbit calibration and characterization, including a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system for the radiometric calibration of the 20 reflective solar bands (RSB), a blackbody (BB) for the radiometric calibration of the 16 thermal emissive bands (TEZB), and a spectro-radiometric calibration assembly (SRCA) for the sensors' spatial and spectral characterization. The task of continuously performing high quality on-orbit calibration and characterization of all 36 spectral bands with a total of 490 detectors located on four focal plane assemblies is extremely challenging. The use of a large two-sided paddle wheel scan mirror with a +/- 55 deg scan angle range and a retractable pinhole attenuation screen in front of the SD panel for calibrating the high gain bands have resulted in additional unanticipated complexity. In this paper, we describe some of the key issues in the Terra and Aqua MODIS on-orbit calibration and characterization, and discuss the methods developed to solve these problems or to reduce their impact on the Level 1B calibration algorithms. Instrument performance and current issues are also presented.

Xiong, Xian-Xiong↗

Determination of the NOAA-20 VIIRS screen transmittance functions with both the yaw maneuver and regular on-orbit calibration data

The Visible Infrared Imaging Radiometer Suite (VIIRS) aboard theNOAA-20 satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs) through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and then scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD’s bidirectional reflectance distribution function (BRDF), referred to as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM) whose eight detectors alternately observe the Sun through another attenuation screen (the SDSM screen) and the sunlit SD. The products of the SD screen transmittance and the BRDF at the mission start for both the SDSM and RSBs and the SDSM screen effective transmittance were measured prelaunch. Large unrealistic undulations in the retrieved H-factor were seen when using the prelaunch screen functions. To improve the accuracy of the retrieved H-factor, shortly after the satellite launch, 15 yaw maneuvers were performed to further characterize the screens. Although significantly improved, the H-factor derived using the screen functions determined fromthe yaw maneuver data still has large unrealistic undulations, revealing that the solar azimuth angular step size of the yaw maneuvers is too large. In this paper,we add high-quality regular on-orbitSDcalibration data to the yaw maneuver data to further improve the relative product of the SD screen effective transmittance and the BRDF at the mission start for the SDSM and the SDSM screen relative effective transmittance. The H-factor time series derived from the newly determined screen transmittance functions is much smoother than that derived from using only the yaw maneuver data and thus considerably improves the radiometric calibration accuracy.

Ning Lei↗

CLARREO Pathfinder as a SI-traceable Reference for Satellite Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of an Earthviewing reflected solar (RS) spectrometer that will measure the Earth-reflected solar radiation from International Space Station with an SI-traceable radiometric uncertainty of 0.3% (1-sigma). The high-accuracy CPF measurements will provide an in-orbit reference for intercalibrating other spaceflight RS instruments. The CPF intercalibration team has been tasked to develop a state-of-the-art approach to calibrate the shortwave channel (300-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument and the reflective solar bands (RSB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, both onboard the NOAA-20 satellite, against the CPF benchmark measurements. The aimed intercalibration methodology uncertainty for both the target instruments is also 0.3%. To meet this stringent intercalibration accuracy, the CPF team has developed methods for mitigating the impacts of spatial, spectral, and angular differences between the intercalibration footprints from the CPF and target instruments. To further alleviate uncertainty, the CPF team will employ Polarization Distribution Models (PDMs) to characterize the polarization state of the Earth-reflected radiance as a function of the intercalibration footprint scene type, solar and viewing geometry, and wavelength. The PDMs will assist in identifying low-polarized scene radiances for meticulously intercalibrating the polarization sensitive VIIRS instrument against the significantly-less polarization-sensitive CPF instrument. This paper will highlight the CPF mission overview, the details of the CPF intercalibration approach, and additional outcomes of the CPF intercalibration studies that may benefit the broader remote sensing community.community.

Hyperspectral↗

Cross-Calibration of the Oceansat-2 Ocean Colour Monitor (OCM) with Terra and Aqua MODIS

The Ocean Colour Monitor (OCM) sensor on-board the Oceansat-2 spacecraft has been operational since its launch in September, 2009. The Oceansat 2 OCM primary design goal is to provide continuity to Oceansat-1 OCM to obtain information regarding various ocean-colour variables. OCM acquires Earth scene measurements in eight multi-spectral bands in the range from 402 to 885 nm. The MODIS sensor on the Terra and Aqua spacecraft has been successfully operating for over a decade collecting measurements of the earth's land, ocean surface and atmosphere. The MODIS spectral bands, designed for land and ocean applications, cover the spectral range from 412 to 869 nm. This study focuses on comparing the radiometric calibration stability of OCM using near-simultaneous TOA measurements with Terra and Aqua MODIS acquired over the Libya 4 target. Same-day scene-pairs from all three sensors (OCM, Terra and Aqua MODIS) between August, 2014 and September, 2015 were chosen for this analysis. On a given day, the OCM overpass is approximately an hour after the Terra overpass and an hour before the Aqua overpass. Due to the orbital differences between Terra and Aqua, MODIS images the Libya 4 site at different scan-angles on a given day. Some of the high-gain ocean bands for MODIS tend to saturate while viewing the bright Libya 4 target, but bands 8-10 (412 nm - 486 nm) provide an unsaturated response and are used for comparison with the spectrally similar OCM bands. All the standard corrections such as bidirectional reflectance factor (BRDF), relative spectral response mismatch, and impact for atmospheric water-vapor are applied to obtain the reflectance differences between OCM and the two MODIS instruments. Furthermore, OCM is used as a transfer radiometer to obtain the calibration differences between Terra and Aqua MODIS reflective solar bands.

Angal, Amit↗

Determination of Response Versus Scan Angle for the NOAA-20 Visible Infrared Imaging Radiometer Suite Thermal Emissive Bands from Emissive Radiation Measurements During the Pitch Maneuver

The visible infrared imaging radiometer suite (VIIRS) is a key sensor onboard the newly launched (November 18, 2017) NOAA-20 satellite and the early launched Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its onboard calibration components include a solar diffuser (SD) and a SD stability monitor for the reflective solar bands, a V-grooved blackbody for the thermal emissive bands (TEBs),and a space view port for background subtraction. These onboard calibrators are located at fixed scan angles. The response versus scan angle (RVS) of the VIIRS scan mirror was characterized prelaunch in lab-ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft-level pitch maneuver was scheduled during the initial intensive calibration and validation testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of the scan angle, which can be used to characterize the TEBRVS. We analyze the NOAA-20 pitch maneuver data and assess the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half-angle mirror.

Wu, Aisheng↗

Postlaunch Assessment of the Response Versus Scan Angle for the Thermal Emissive Bands of Visible Infrared Imaging Radiometer Suite On-Board the Suomi National Polar-Orbiting Partnership Satellite

The visible infrared imaging radiometer suite (VIIRS) is a key sensor carried on the Suomi national polar-orbiting partnership (S-NPP) satellite, which was launched in October 2011. It has several on-board calibration components, including a solar diffuser and a solar diffuser stability monitor for the reflective solar bands, a V-groove blackbody for the thermal emissive bands (TEB), and a space view port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle. Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first 3 months of intensive Cal/Val. The S-NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of Earth view scan angles, which can be used to characterize the TEB RVS. This study provides our analysis of the pitch maneuver data and assessment of the derived TEB RVS by comparison with prelaunch results. In addition, the stability of the RVS after the first 5 years of operation is examined using observed brightness temperatures (BT) over a clear ocean at various angles of incidence (AOI). To reduce the impact of variations in the BT measurements, the daily overpasses collected over the ocean are screened for cloud contamination, normalized to the results obtained at the blackbody AOI, and averaged each year.

Wu, Aisheng↗

Assessment of the NPP VIIRS RVS for the Thermal Emissive Bands Using the First Pitch Maneuver Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) (launched in October 2011). VIIRS sensor design draws on heritage instruments including AVHRR, OLS, SeaWiFS and MODIS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first three months of intensive Cal/Val. The NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of scan angles, which can be used to characterize the TEB RVS. This study will provide our analysis of the pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab tests will be conducted for each band, detector, and half angle mirror (HAM) side

Wu, A.↗