Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Visual scanning behavior and pilot workload

Sophisticated man machine interaction often requires the human operator to perform a stereotyped scan of various instruments in order to monitor and/or control a system. For situations in which this type of stereotyped behavior exists, such as certain phases of instrument flight, scan pattern was shown to be altered by the imposition of simultaneous verbal tasks. A study designed to examine the relationship between pilot visual scan of instruments and mental workload is described. It was found that a verbal loading task of varying difficulty causes pilots to stare at the primary instrument as the difficulty increases and to shed looks at instruments of less importance. The verbal loading task also affected the rank ordering of scanning sequences. By examining the behavior of pilots with widely varying skill levels, it was suggested that these effects occur most strongly at lower skill levels and are less apparent at high skill levels. A graphical interpretation of the hypothetical relationship between skill, workload, and performance is introduced and modelling results are presented to support this interpretation.

Tole, J. R.↗

The effectiveness of using real-time eye scanning information for pilot training

A study to evaluate the idea of providing pilots feedback on their scan behavior as an instrumentional training aid was conducted jointly by NASA, Piedmont Aviation, and Old Dominion University. The study used Langley's oculometer system to provide a real-time display of the trainee's scan to the instructor pilot in the aft part of the Boeing 737 training simulator at Piedmont. The trainees' scan behavior was also video-taped for viewing by the instructor and trainee after each training session. Based on qualitative data obtained during the study, scan behavior feedback was an effective tool for pilot training.

Spady, A. A., Jr.↗

Optimized three-dimensional lenses for wide-angle scanning

Three-dimensional bootlace lens antennas with two and four focal points can be optimized to produce high-quality scanned beams over a wide field of view. For two-dimensional scanning, the planar feed locus is replaced by a curved feed locus designed to minimize path length errors. Comparisons with previous bootlace lens designs demonstrate the advantages of this focal distribution. The bifocal lens shows good scanning performance in both principal and orthogonal planes. The quadrufocal lens performs better in its principal plane than in its orthogonal plane. It is also shown that the quadrufocal lens can be realized with a planar outer surface and a circular focal arc, and improved scanning performance is still achievable. Further optimization of the focal arc and/or relaxation of the planar outer surface condition results in quadrufocal lenses with negligible phase errors in the principal plane.

Rappaport, C. M.↗

Noninterlaced-To-Interlaced Television-Scan Converter

Computer text and ordinary images displayed together without text jitter. Scan converter enables superposition of alphanumerical text generated by computer-driven video generator on National Television System Committee (NTSC) standard interlaced-scan image. Made of commercially available integrated circuits and operates in conjunction with NTSC synchronizing-signal generator. Standard television picture transmitted in two interlaced fields. Without scan converter, text image moves up and down by one line as fields change. With scan converter, text image stands still.

Morales, Sergio↗

Systems for ultrasonic scanning, analysis and imagery

A variety of ultrasonic scanning and imagery techniques are used to investigate various aspects of materials and microstructures. Two ultrasonic scanning systems are in use by the Lewis Research Center's Structural Integrity Branch: an immersion scanner and a contact scanning system. The basic principles of scanning are reviewed, examples of images are presented, and structural features suggested by these images are discussed. Both of these systems are custom designed; their capabilities, advantages, and disadvantages are highlighted.

Stang, David B.↗

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Scan-independent slot arrays with parasitic wire arrays in stratified medium

The effect of a parasitic wire array on the scan admittance of a slot array has been investigated. Structures considered can consist of an infinite slot array and an arbitrary number of parasitic infinte arrays of piecewise linear wires, all arrays being embedded in a stratified medium. These include, as particular cases, phased arrays of Clavin elements. Expressing the fields from the arrays as plane waves, a procedure similar to the periodic moment method for infinite periodic structures is set up to obtain the the scan admittance of the slot array. Scan admittances are presented for a slot array with monopole arrays in free space, and a slot array with a tilted dipole array in a stratified medium. Blind spots at which the incident energy is mainly reflected rather than transmitted were found. Results obtained indicate the possibility of using parasitic wire arrays for scan compensation of active slot arrays.

Ng, Kwong T.↗

Tuning and scanning control system for high resolution alexandrite lasers

An alexandrite laser is spectrally narrowed and tuned by the use of three optical elements. Each element provides a successively higher degree of spectral resolution. The digitally controlled tuning and scanning control servo system simultaneously positions all three optical elements to provide continuous high resolution laser spectral tuning. The user may select manual, single, or continuous modes of automated scanning of ranges up to 3.00/cm and at scan rates up to 3.85/cm/min. Scanning over an extended range of up to 9.999/cm may be achieved if the highest resolution optic is removed from the system. The control system is also capable of being remotely operated by another computer or controller via standard RS-232 serial data link.

Smith, James C.↗

Unbalanced Rotating Masses For Scanning

Unbalanced rotating masses low-cost, low-power, lightweight means of generating scanning torques for scientific instruments. Imparts variety of scanning patterns; continuous circular, back-and-forth linear, and, with aid of indexing mechanism, raster. Scanning rate determined by sizes of moment arms and rotational velocities. System of unbalanced rotating masses proposed for scanning gimbaled sensors that observe Sun from balloon-borne gondola. Two unbalanced masses move sensor aim in circular pattern around center of the Sun.

Polites, Michael E.↗

Reconfiguring the RUM experiment to test circular scanning with rotating unbalanced-mass devices on gimbaled payloads

This paper describes a ground-based experiment designed to prove the concept of circular scanning a gimbaled payload with rotating unbalanced-mass (RUM) devices. The experiment is a modified version of a similar experiment which demonstrates line and raster scanning with RUM's. In this paper, a description of the experiment hardware is presented and a detailed design of the servos used in scanning is given. A computer simulation model of the entire system is discussed and simulation results are included. These verify the servo designs and show the RUM's to be an extremely power efficient method for circular scanning.

Polites, M. E.↗

Scanning Tunneling Microscope For Use In Vacuum

Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

Abel, Phillip B.↗

Radar sensitivity and antenna scan pattern study for a satellite-based Radar Wind Sounder (RAWS)

Modeling global atmospheric circulations and forecasting the weather would improve greatly if worldwide information on winds aloft were available. Recognition of this led to the inclusion of the LAser Wind Sounder (LAWS) system to measure Doppler shifts from aerosols in the planned for Earth Observation System (EOS). However, gaps will exist in LAWS coverage where heavy clouds are present. The RAdar Wind Sensor (RAWS) is an instrument that could fill these gaps by measuring Doppler shifts from clouds and rain. Previous studies conducted at the University of Kansas show RAWS as a feasible instrument. This thesis pertains to the signal-to-noise ratio (SNR) sensitivity, transmit waveform, and limitations to the antenna scan pattern of the RAWS system. A dop-size distribution model is selected and applied to the radar range equation for the sensitivity analysis. Six frequencies are used in computing the SNR for several cloud types to determine the optimal transmit frequency. the results show the use of two frequencies, one higher (94 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) for better penetration in rain, provide ample SNR. The waveform design supports covariance estimation processing. This estimator eliminates the Doppler ambiguities compounded by the selection of such high transmit frequencies, while providing an estimate of the mean frequency. the unambiguous range and velocity computation shows them to be within acceptable limits. The design goal for the RAWS system is to limit the wind-speed error to less than 1 ms(exp -1). Due to linear dependence between vectors for a three-vector scan pattern, a reasonable wind-speed error is unattainable. Only the two-vector scan pattern falls within the wind-error limits for azimuth angles between 16 deg to 70 deg. However, this scan only allows two components of the wind to be determined. As a result, a technique is then shown, based on the Z-R-V relationships, that permit the vertical component (i.e., rain) to be computed. Thus the horizontal wind components may be obtained form the covariance estimator and the vertical component from the reflectivity factor. Finally, a new candidate system is introduced which summarizes the parameters taken from previous RAWS studies, or those modified in this thesis.

Stuart, Michael A.↗

Directivity versus element spacing for a scanning array

The results of the present examination of the relationship of directivity with element spacings of linear, rectangular, and hexagonal arrays indicate that element spacings for optimal directivity vary with scan angles; this is especially true in the case of changes in aperture sizes and the appearance of grating lobes in the visible space. Grating lobe effects are more pronounced for isotropic than for directive element arrays. Directivity decreases as the beam scans off from boresight, and rapidly diminishes for scans over 30 deg. The hexagonal array has higher directivity for scans of less than 20 deg, and the linear array for those over 30 deg.

Zimmerman, M.↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Non-Scanning Radiometer Results for Earth Radiation Budget Investigations

The Earth Radiation Budget Experiment (ERBE) included non-scanning radiometers (Luther, 1986) flown aboard a dedicated mission of Earth Radiation Budget Satellite, and the NOAA-9 and -10 operational meteorological spacecraft (Barkstrom and Smith, 1986). The radiometers first began providing Earth radiation budget data in November 1984 and have remained operational, providing a record of nearly 8 years of data to date for researchers. Although they do not produce measurements with the resolution given by the scanning radiometers, the results from the non-scanning radiometers are extremely useful for climate research involving long-term radiation data sets. This paper discusses the non-scanning radiometers, their stability, the method of analyzing the data, and brief scientific results from the data.

Smith, G. Louis↗

Z-Scan Measurement of the Nonlinear Absorption of a Thin Gold Film

We have used the z-scan technique at a wavelength (532 nm) near the transmission window of bulk gold to measure the nonlinear absorption coefficient of continuous approximately 50-Angstrom-thick gold films, deposited onto surface-modified quartz substrates. For highly absorbing media such as metals, we demonstrate that determination of either the real or imaginary part of the third-order susceptibility requires a measurement of both nonlinear absorption and nonlinear refraction, i.e. both open- and closed-aperture z-scans must be performed. Closed-aperture z-scans did not yield a sufficient signal for the determination of the nonlinear refraction. However, open-aperture z-scans yielded values ranging from Beta = 1.9 x 10(exp -3) to 5.3 x 10(exp -3) cm/W in good agreement with predictions which ascribe the nonlinear response to a Fermi smearing mechanism. We note that the sign of the nonlinearity is reversed from that of gold nanoparticle composites, in accordance with the predictions of mean field theories.

Smith, David D.↗

Ground Based Operational Testing Of Holographic Scanning Lidars : The HOLO Experiments

Two aerosol backscatter lidar measurement campaigns were conducted using two holographic scanning lidars and one zenith staring lidar for the purposes of reliability testing under field conditions three new lidar systems and to develop new scanning measurement techniques and applications. The first campaign took place near the campus of Utah State University in Logan Utah in March of 1999 and is called HOLO-1. HOLO-2 was conducted in June of 1999 on the campus of Saint Anselm College, near the city of Manchester, New Hampshire. Each campaign covered a period of approximately one week of nearly continuous observation of cloud and aerosol backscatter in the visible and near infrared by lidar, and wide field visible sky images by video camera in the daytime. The scanning capability coupled with a high rep-rate, high average power laser enables both high spatial and high temporal resolution observations that Particularly intriguing is the possibility of deriving atmospheric wind profiles from temporal analysis of aerosol backscatter spatial structure obtained by conical scan without the use of Doppler techniques.

Schwemmer, Geary K.↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗