Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCREEN EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A model for the acoustic impedance of linear suppressor materials bonded on perforated plate

An analytical model is developed for the acoustic impedance of a composite made of a fine screen bonded to a perforated plate, the resistance having been modeled using steady flow theory and data, and including both linear and nonlinear components. The model of the screen resistance alone is derived first, and it is then extended to include a perforated plate bonded to the screen. Quantities such as effective open ratio and pressure recovery are evaluated. Conclusions are presented, including: (1) when the screen is bonded to a perforated plate, the linear resistance increases as the inverse of the perforate open area, (2) the nonlinearity in the screen resistance depends on the square of the screen wire diameter, and (3) when the resistance is considered as a function of approach velocity, the screen nonlinear term increases as the inverse of the square of the perforated plate open area ratio. The general theory can be applied to any screen structure, but final results are limited to a twilled square weave screen. Results can be applied to the study of sound absorbing materials used for lining the walls of aircraft engine duct suppressors.

Rice, E. J.↗

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi↗

Pressure drop and He II flow through fine mesh screens

Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.

Maddocks, J. R.↗

Adaptive Data Screening for Multi-Angle Polarimetric Aerosol and Ocean Color Remote Sensing Accelerated by Automatic Differentiation

Remote sensing measurements from multi-angle polarimeters (MAPs) contain rich aerosol microphysical property information, and these sensors have been used to perform retrievals in optically complex atmosphere and ocean systems. Previous studies have concluded that, generally, five moderately separated viewing angles in each spectral band provide sufficient accuracy for aerosol property retrievals, with performance gradually saturating as angles are added above that threshold. The Hyper-Angular Rainbow Polarimeter (HARP) instruments provide high angular sampling with a total of 90-120 unique angles across four bands, a capability developed mainly for liquid cloud retrievals. In practice, not all view angles are optimal for aerosol retrievals due to impacts of clouds, sun glint, and other impediments. The many viewing angles of HARP can provide resilience to these effects, if the impacted views are screened from the dataset, as the remaining views may be sufficient for successful analysis. In this study, we discuss how the number of available viewing angles impacts aerosol and ocean color retrieval uncertainties, as applied to two versions of the HARP instrument. AirHARP is an airborne prototype that was deployed in the ACEPOL field campaign, while HARP2 is an instrument in development for the upcoming NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. Based on synthetic data, we find that a total of 20-30 angles across all bands (i.e. five to eight viewing angles per band) are sufficient to achieve good retrieval performance. Following from this result, we develop an adaptive multi-angle polarimetric data screening (MAPDS) approach to evaluate data quality by comparing measurements with their best-fitted forward model. The FastMAPOL retrieval algorithm is used to retrieve scene geophysical values, by matching an efficient, deep learning-based, radiative transfer emulator to observations. The data screening method effectively identifies and removes viewing angles affected by thin cirrus clouds and other anomalies, improving retrieval performance. This was tested with AirHARP data, and we found agreement with the High Spectral Resolution Lidar-2 (HSRL-2) aerosol data. The data screening approach can be applied to modern satellite remote sensing missions, such as PACE, where a large amount of multi-angle, hyperspectral, polarimetric measurements will be collected.

multi-angle polarimeter↗

COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

Brusse, Jay A.↗

Fatigue failure of regenerator screens in a high frequency Stirling engine

Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenerator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain a 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.

Hull, David R.↗

Fatigue failure of regenerator screens in a high frequency Stirling engine

Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.

Hull, David R.↗

An experimental investigation of a large delta P settling chamber for a supersonic pilot quiet tunnel

The mean streamwise flow distributions and turbulence levels across the chamber were measured with a hot wire anemometer downstream of a series of porous Rigimesh plates which were shown to be an effective means of reducing the chamber acoustic disturbance levels due to upstream pipe and valve systems. Tests made with various types of flow conditioners downstream of the porous plates showed that a series of screens was the most effective means of achieving the objective of a uniform mean flow distribution with reduced vorticity levels downstream of the porous components. Frequency spectra obtained across the series of screens show that they reduce vorticity over a wide frequency range for several different initial upstream vorticity conditions. Improvements in the mechanical installation of the porous plates and damping screens and the use of porous plates with more uniform porosity should reduce the freestream velocity fluctuations to the minimum acoustic levels of about 0.5 percent.

Piatt, M.↗

Mutagenic screening of diamine monomers

The effects of phenyl ring coupling moieties, of isomeric amine positions relative to the coupling groups, and of insertion of other coupling groups on the mutagenic response of a series of dianilines were investigated using the Ames Salmonella assay. Generally, S-9 metabolic activation from Aroclor-induced rat liver was required for mutagenic expression. The range of mutagenicity of steric isomers of several dianiline series was also investigated. No mutagenicity was found for purified samples of o,o' and m,p' isomers of methylene dianiline (MDA) and diaminobenzophenone, while varying degrees of mutagenicity were found for other isomers. The mutagenicity of "benzylogs" of MDA decreased as the degree of linear separation of the m,m' anilino groups by aromatic rings increased. Methylation and two-year storage increased mutagenic response in certain isomers of MDA. However, high performance liquid chromatography indicated there was no discernible change in m,p'-MDA samples aged under varied conditions over four months. Likewise, no change in mutagenicity was found.

Ross, W. D.↗

Ionization of multielectron atoms by fast charged particles.

Using plane waves to describe the incident and scattered particles, and screened hydrogenic and Coulomb functions to describe the atomic electrons before and after ejections, we have calculated the differential and total ionization cross sections of 11 atoms and one ion by electron impact, and ionization of helium by proton impact. The effective charges of the screened hydrogenic functions are fixed by the Hartree-Fock calculations. Calculations have been carried out for the atomic s, p, and d electrons. For low atomic numbers, we find reasonable agreement with the experimental data. For intermediate atomic numbers, we expect our results to overestimate the actual cross sections, since our choice of a unit charge for the Coulomb function of the ejected electrons will overestimate the atomic dipole potential strength, and in turn the high-energy cross sections. The advantage of the method presented here is that the ionization amplitude is given in analytic form. This may allow further analysis on this amplitude, and facilitates extension of the numerical integration for the cross section to high impact energies.

Omidvar, K.↗

MODIS Solar Diffuser: Modelled and Actual Performance

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument's solar diffuser is used in its radiometric calibration for the reflective solar bands (VIS, NTR, and SWIR) ranging from 0.41 to 2.1 micron. The sun illuminates the solar diffuser either directly or through a attenuation screen. The attenuation screen consists of a regular array of pin holes. The attenuated illumination pattern on the solar diffuser is not uniform, but consists of a multitude of pin-hole images of the sun. This non-uniform illumination produces small, but noticeable radiometric effects. A description of the computer model used to simulate the effects of the attenuation screen is given and the predictions of the model are compared with actual, on-orbit, calibration measurements.

Waluschka, Eugene↗

Evidence against the involvement of ionically bound cell wall proteins in pea epicotyl growth

Ionically bound cell wall proteins were extracted from 7 day old etiolated pea (Pisum sativum L. cv Alaska) epicotyls with 3 molar LiCl. Polyclonal antiserum was raised in rabbits against the cell wall proteins. Growth assays showed that treatment of growing region segments (5-7 millimeters) of peas with either dialyzed serum, serum globulin fraction, affinity purified immunoglobulin, or papain-cleaved antibody fragments had no effect on growth. Immunofluorescence microscopy confirmed antibody binding to cell walls and penetration of the antibodies into the tissues. Western blot analysis, immunoassay results, and affinity chromatography utilizing Sepharose-bound antibodies confirmed recognition of the protein preparation by the antibodies. Experiments employing in vitro extension as a screening measure indicated no effect upon extension by antibodies, by 50 millimolar LiCl perfusion of the apoplast or by 3 molar LiCl extraction. Addition of cell wall protein to protease pretreated segments did not restore extension nor did addition of cell wall protein to untreated segments increase extension. It is concluded that, although evidence suggests that protein is responsible for the process of extension, the class(es) of proteins which are extracted from pea cell walls with 3 molar LiCl are probably not involved in this process.

NASA Program Space Biology↗

Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

Feiveson, Alan H.↗

Pulsar Polar Cap Heating and Surface Thermal X-ray Emission: Curvature Radiation Pair Fronts - 1

We investigate the effect of pulsar polar cap (PC) heating produced by positrons returning from the upper pair formation front. Our calculations are based on a self-consistent treatment of the pair dynamics and the effect of electric field screening by the returning positrons. We calculate the resultant X-ray luminosities and discuss the dependence of the PC heating efficiencies on pulsar parameters, such as characteristic spin-down age, spin period, and surface magnetic field strength. In this study we concentrate on the regime where the pairs are produced in a magnetic field by curvature photons emitted by accelerating electrons. Our theoretical results are not in conflict with the available observational x-ray data and suggest that the effect of PC heating should significantly contribute to the thermal x-ray fluxes from middle-aged and old pulsars. The implications for current and future x-ray observations of pulsars are briefly outlined.

Harding, Alice K.↗

Mechanism of ion pairing–induced co-ion penetration into the stern layer

In classical electric double layer (EDL) theory, co-ions—ions carrying the same charge as the electrode—are assumed to be excluded from the Stern layer because of electrostatic repulsion. However, ion pairing with adsorbed counterions may enable co-ions to access the EDL, a phenomenon that remains underexplored. Key questions therefore remain unresolved, including how deeply co-ions penetrate, how ion-specific properties govern them, and how ion pairing within the EDL differs from bulk solution. Here, in this study, we employ molecular dynamics simulations combined with well-tempered metadynamics to quantify co-ion penetration and ion-pairing thermodynamics at positively charged Mg-Al layered double hydroxide interfaces (σ = +20.6 μC/cm 2 ) in aqueous chloride electrolytes across 0.005–3 M range. We reveal a concentration-driven crossover: at dilute conditions, counterion–co-ion contact ion pairing (CIP) is thermodynamically unfavorable or only weakly favorable (ΔG CIP = +0.12 kcal/mol for Li + to −0.42 kcal/mol for K + ), leading to co-ion exclusion. As concentration increases (≥0.5 M), enhanced screening reduces surface repulsion and stabilizes CIP thermodynamics (ΔG CIP = −0.89 kcal/mol for Li + to −1.05 kcal/mol for K + at 3 M), enabling monovalent co-ions to penetrate the Stern layer following the hydration hierarchy K + > Na + > Li + , while divalent co-ions (Mg 2+ , Ca 2+ ) remain in the diffuse layer, forming only solvent-separated pairs. Comparison with bulk solution shows interfacial ion pairing is suppressed at low concentrations but converges to bulk-like thermodynamics at high concentrations, indicating surface effects vanish under strong screening. These results establish a quantitative framework linking ion-pairing thermodynamics to co-ion penetration and providing strategies to design electrochemical interfaces.

Co-ion penetration↗

Mutations in the gravity persistence signal loci in Arabidopsis disrupt the perception and/or signal transduction of gravitropic stimuli

Gravity plays a fundamental role in plant growth and development, yet little is understood about the early events of gravitropism. To identify genes affected in the signal perception and/or transduction phase of the gravity response, a mutant screen was devised using cold treatment to delay the gravity response of inflorescence stems of Arabidopsis. Inflorescence stems of Arabidopsis show no response to gravistimulation at 4 degrees C for up to 3 h. However, when gravistimulated at 4 degrees C and then returned to vertical at room temperature (RT), stems bend in response to the previous, horizontal gravistimulation (H. Fukaki, H. Fujisawa, M. Tasaka [1996] Plant Physiology 110: 933-943). This indicates that gravity perception, but not the gravitropic response, occurs at 4 degrees C. Recessive mutations were identified at three loci using this cold effect on gravitropism to screen for gravity persistence signal (gps) mutants. All three mutants had an altered response after gravistimulation at 4 degrees C, yet had phenotypically normal responses to stimulations at RT. gps1-1 did not bend in response to the 4 degrees C gravity stimulus upon return to RT. gps2-1 responded to the 4 degrees C stimulus but bent in the opposite direction. gps3-1 over-responded after return to RT, continuing to bend to an angle greater than wild-type plants. At 4 degrees C, starch-containing statoliths sedimented normally in both wild-type and the gps mutants, but auxin transport was abolished at 4 degrees C. These results are consistent with GPS loci affecting an aspect of the gravity signal perception/transduction pathway that occurs after statolith sedimentation, but before auxin transport.

NASA Discipline Plant Biology↗

Transport properties of epitaxial lift off films

Transport properties of epitaxially lifted-off (ELO) films were characterized using conductivity, Hall, and Shubnikov-de Haas measurements. A 10-15 percent increase in the 2D electron gas concentration was observed in these films as compared with adjacent conventional samples. We believe this result to be caused by a backgating effect produced by a charge build up at the interface of the ELO film and the quartz substrate. This increase results in a substantial decrease in the quantum lifetime in the ELO samples, by 17-30 percent, but without a degradation in carrier mobility. Under persistent photoconductivity, only one subband was populated in the conventional structure, while in the ELO films the population of the second subband was clearly visible. However, the increase of the second subband concentration with increasing excitation is substantially smaller than anticipated due to screening of the backgating effect.

Mena, R. A.↗