Electrically Isolating Thermally Coupled Device for Noise Suppression of Circuits in Deep Space

Mixed mode rad hard avionics Systems on a Chip (SoC) designed for deep space applications such as Europa orbiters and Europa Landers will require data isolation circuits to block noise. This paper presents the simulation performance for a novel rad hard SOI CMOS compatible thermal transducer used for on-chip data isolation in SoC. The research presented involves the use of commercially available computer aided design tools to model the transient electrothermal behavior of the transducer. Both one- and two-dimensional analyses of a prototype thermal transducer were performed. Results indicate that thermal-based data isolator technology can pass a data bit in under a microsecond and, as a measurement of feasibility, I(exp 2)C bus specifications can be met.

Mantooth, A.↗

Ultra-Sensitive Magnetoresistive Displacement Sensing Device

An ultrasensitive displacement sensing device for use in accelerometers, pressure gauges, temperature transducers, and the like, comprises a sputter deposited, multilayer, magnetoresistive field sensor with a variable electrical resistance based on an imposed magnetic field. The device detects displacement by sensing changes in the local magnetic field about the magnetoresistive field sensor caused by the displacement of a hard magnetic film on a movable microstructure. The microstructure, which may be a cantilever, membrane, bridge, or other microelement, moves under the influence of an acceleration a known displacement predicted by the configuration and materials selected, and the resulting change in the electrical resistance of the MR sensor can be used to calculate the displacement. Using a micromachining approach, very thin silicon and silicon nitride membranes are fabricated in one preferred embodiment by means of anisotropic etching of silicon wafers. Other approaches include reactive ion etching of silicon on insulator (SOI), or Low Pressure Chemical Vapor Deposition of silicon nitride films over silicon substrates. The device is found to be improved with the use of giant magnetoresistive elements to detect changes in the local magnetic field.

Olivas, John D.↗

Global Time-Variable Gravity and its Geophysical/Climatic Connections

Any large mass transport in the Earth system produces changes in the gravity field. Low harmonic degree components of such variations have been observed by the satellite-laser-ranging (SLR) technique, particularly in 52, the Earth's dynamic oblateness. 52 has long been observed to undergo a slight decrease due to the post-glacial rebound of the mantle -- until around 1998, when it switched quite suddenly to an increase trend which continued to 2001 before sharply turning back to normal , signifying a large change in global mass distribution whose 52 effect overshadows that of the post-glacial rebound over interannual timescales. Intriguing evidences have been found in the Ocean water distribution, especially related to the Pacific Decadal Oscillation in the extratropical Pacific basins, that may be responsible for this 52 anomaly. Besides the lowest-degree 52, recent updates in the SLR-derived time series of the Earth's low-degree gravity components also show shorter wavelength zonal and other longitudinal signals. While the formal uncertainty of these terms is significantly higher than that for 52, some of these series have significant signal that appears to be climatic in origin. For example, there is a significant correlation of the sectoral S2,2 with the Tahiti-Darwin Southern Oscillation Index (SOI), but preceding SO1 by about 1 year. Similar cases demonstrate the utility of assessing the mass component of climate variations. We will present these intriguing results.

Chao, Benjamin F.↗

Fabrication of Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the Next Generation Space Telescope (NGST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The NGST environment requires cryogenic operation at 45K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x100 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi-layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (RE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form frames and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force.

Li, Mary J.↗

Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the James Webb Space Telescope (JWST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The JWST environment requires cryogenic operation at 35K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 p. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi- layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (NE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form W e s and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force. . . . KEYWORDS: microshutter, MEMS, RIE, DRIE, micro-optics, near inbred, space telescope

Li, Mary J.↗

PDSOI and Radiation Effects: An Overview

Bulk silicon substrates are a common characteristic of nearly all commercial, Complementary Metal-Oxide-Semiconductor (CMOS), integrated circuits. These devices operate well on Earth, but are not so well received in the space environment. An alternative to bulk CMOS is the Silicon-On-Insulator (SOI), in which a &electric isolates the device layer from the substrate. SO1 behavior in the space environment has certain inherent advantages over bulk, a primary factor in its long-time appeal to space-flight IC designers. The discussion will investigate the behavior of the Partially-Depleted SO1 (PDSOI) device with respect to some of the more common space radiation effects: Total Ionized Dose (TID), Single-Event Upsets (SEUs), and Single-Event Latchup (SEL). Test and simulation results from the literature, bulk and epitaxial comparisons facilitate reinforcement of PDSOI radiation characteristics.

Forgione, Joshua B.↗

The four-gate transistor

The four-gate transistor or G4-FET combines MOSFET and JFET principles in a single SOI device. Experimental results reveal that each gate can modulate the drain current. Numerical simulations are presented to clarify the mechanisms of operation. The new device shows enhanced functionality, due to the combinatorial action of the four gates, and opens rather revolutionary applications.

neuro-prosthetic devices cortical signals↗

Characterization of Semiconductor Materials Using AOTF Instruments

A non-invasive characterization of silicon-on-insulator (SOI) wafers using white light interference measured by an AOTF polarimetric hyperspectral imaging instrument will be presented an an illustration of the technology potential. Experiments provided high resolution thickness maps of both silicon and oxide layers with accuracy and observed optically active imperfections and distributions in the structure.

polarimetric hyperspectral imaging silicon oxide↗

Critical monitoring of the Cassini Saturn Orbit Insertion maneuver

The Cassini-Huygens spacecraft will have spent seven years since launch by the time it reaches Saturn and its satellites. The primary mission will begin after the Saturn Orbit Insertion (SOI) scheduled for early July 2004. the insertion will require a critical navigational maneuver that involves firing the orbiter's thrusters leading to the capture in the gravity well of the planet. This paper will describe the challenges and plans by the Cassini Program to monitor the Saturn Orbit Insertion Maneuver.

Cassini↗

Cassini Distributed Instrument Operations: What We've Learned Since Saturn Orbit Insertion

The Cassini mission to Saturn is complex with 12 science teams conducting distributed operations across the United States and Europe. Each Team includes scientists from around the world who actively participate in operations, including observation design, instrument commanding, downlink processing, and archiving. This represents a change in how JPL complex deep-space missions have been operated. Since Saturn Orbit Insertion (SOI), the Cassini Project has spent 17 months conducting science operations and has gained real-world experience that has tested the assumptions and rationale for this approach. We have learned that many of the expected benefits have been realized, but there were numerous unexpected challenges as well. This paper will discuss the lessons learned from the Cassini Tour experience to date. It will revisit the assumptions and rationale behind the distributed instrument operations design and will describe the results, good and bad, of implementing this method of operations. We will describe how Instrument Teams are structured, their roles and responsibilities, what challenges they faced going into orbital operations (the 'tour') and what creative solutions were proposed when funding limitations and schedule milestones prevented optimum solutions. We will also discuss the problems that have been encountered both on the ground and with the instruments, how these problems and anomalies were overcome, and what was learned along the way about the characteristics of distributed instrument operations.

Cassini↗

Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment.

Kim, Myung-Hee Y.↗

Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

Kim, Myung-Hee Y.↗

Frequency Dependence of Single-Event Upset in Highly Advanced PowerPC Microprocessors

Single-event upset effects from heavy ions were measured for Motorola silicon-on-insulator (SOI) microprocessor with 90 nm feature sizes at three frequencies of 500, 1066 and 1600 MHz. Frequency dependence of single-event upsets is discussed. The results of our studies suggest the single-event upset in registers and D-Cache tend to increase with frequency. This might have important implications for the overall single-event upset trend as technology moves toward higher frequencies.

Cyclotron↗

The USNA MIDN Microdosimeter Instrument

This paper describes the MIcroDosimetry iNstrument (MIDN) mission now under development at the United States Naval Academy. The instrument is manifested to fly on the MidSTAR-1 spacecraft, which is the second spacecraft to be developed and launched by the Academy s faculty and midshipmen. Launch is scheduled for 1 September 2006 on an ATLAS-5 launch vehicle. MIDN is a rugged, portable, low power, low mass, solid-state microdosimeter designed to measure in real time the energy distributions of energy deposited by radiation in microscopic volumes. The MIDN microdosimeter sensor is a reverse-biased silicon p-n junction array in a Silicon-On-Insulator (SOI) configuration. Microdosimetric frequency distributions as a function of lineal energies determine the radiation quality factors in support of radiation risk estimation to humans.

Pisacane, V. L.↗