Ground Testing for a 10 K Sorption Cryocooler Flight Expeiment (BETSCE)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present the general principles of gas gap heat switches that impact their performances for the Planck cryocooler, develop two figures of merit relevant to this application, and present initial characterization results of switches using uranium or ZrNi as the hydriding material.
The Jet Propulsion Laboratory has built and delivered two continuous closed cycle hydrogen Joule-Thomson (JT) cryocoolers for the ESA Planck mission, which will measure the anisotropy in the cosmic microwave background. The metal hydride compressor consists of six sorbent beds containing LaNi4.78Sn0.22 alloy and a low pressure storage bed of the same material. Each sorbent bed contains a separate gas-gap heat switch that couples or isolates the bed with radiators during the compressor operating cycle. ZrNiHx hydride is used in this heat switch. The Planck compressor produces hydrogen gas at a pressure of 48 Bar by heating the hydride to approx.450 K. This gas passes through a cryogenic cold end consisting of a tube-in-tube heat exchanger, three pre-cooling stages to bring the gas to nominally 52 K, a JT value to expand the gas into the two-phase regime at approx.20 K, and two liquid - vapor heat exchangers that must remove 190 and 646 mW of heat respectively.
A regenerative adsorbent heat pump process and system for cooling and heating a space. A sorbent is confined in a plurality of compressors of which at least four are first stage and at least four are second stage. The first stage operates over a first pressure region and the second stage over a second pressure region which is higher than the first. Sorbate from the first stage enters the second stage. The sorbate loop includes a condenser, expansion valve, evaporator and the compressors. A single sorbate loop can be employed for single-temperature-control such as air conditioning and heating. Two sorbate loops can be used for two-temperature-control as in a refrigerator and freezer. The evaporator temperatures control the freezer and refrigerator temperatures. Alternatively the refrigerator temperature can be cooled by the freezer with one sorbate loop. A heat transfer fluid is circulated in a closed loop which includes a radiator and the compressors. Low temperature heat is exhausted by the radiator. High temperature heat is added to the heat transfer fluid entering the compressors which are desorbing vapor. Heat is transferred from compressors which are sorbing vapor to the heat transfer fluid, and from the heat transfer fluid to the compressors which are desorbing vapor. Each compressor is subjected to the following phases, heating to its highest temperature, cooling down from its highest temperature, cooling to its lowest temperature, and warming up from its lowest temperature. The phases are repeated to complete a cycle and regenerate heat.
UNKNOWN
Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.
Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.
Explore the source record for details and available documents.
This progress report (Level 3 Milestone Number M3SF-24LL010302052) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Crystalline Work Package Number SF-24LL01030205. The research is focused on actinide and radionuclide sequestration in hydrothermally altered repository materials. In FY24, we completed a rigorous analysis of Se sorption to iron oxide phases using our L-SCIE sorption database. This effort explicitly accounts for surface titration behavior of oxide surfaces that was the subject of a recently published manuscript (Han et al., 2023). With this in mind, our Se sorption analysis now yields a more robust workflow for developing self-consistent surface complexation modeling approaches that can be adapted to specific SCM conceptual and numerical approaches (i.e. non-electrostatic, diffuse layer, triple layer models). In late FY24, we plan to publish the results of our comprehensive surface complexation modeling of Se(IV) and Se(VI) sorption to iron oxide mineral phases and provide a path forward to developing robust radionuclide sorption models for use in performance assessment. In FY24, we also submitted a manuscript summarizing our approach to integrating radionuclide sorption and coprecipitation phenomena and evaluation of radionuclide partitioning values across a range of radionuclides relevant to performance assessment. We demonstrated our approach in detail using Se sorption and coprecipitation with iron oxide minerals as a test case. This manuscript was recently accepted for publication in Applied Geochemistry (Balboni et al., Accepted). We also continued experiments to identify radionuclide interaction with hydrothermally altered crystalline repository and backfill materials. Recent research performed at Los Alamos National Laboratory (LANL) and Sandia National Laboratory (SNL) has provided key insights regarding the hydrothermal alteration behavior of bentonite backfill in the presence of repository materials (steel, concrete, etc.). We are now examining how mineral alteration affects retardation behavior of a suite of radionuclides of interest to repository performance assessment. These experiments also allow us to test the predictive ability of our component additivity approach to surface complexation and ion exchange. Our guiding hypothesis is that a robust surface complexation/ion exchange model and associated database, developed using our L-SCIE approach, can effectively predict changes in radionuclide sorption behavior resulting from the hydrothermal alteration of mineralogy in a repository near field. A short update of results to date is presented below.
Coal Combustion Residual (CCR) landfills in the U.S. can lead to elevated contaminant concentrations in groundwater and runoff, particularly of arsenic, boron, and selenium. Zeolites can be readily synthesized from materials contained within the coal combustion ash impoundments and can be cation-exchanged to enhance adsorption capacity, selectivity, and reactivity. However, the optimization of zeolites becomes a daunting task when accounting for the variety of Si:Al ratios, the species of extra-framework cations present, and the zeolite pore structure. Molecular simulations provide methods to study and guide the design of zeolites for the sorption of contaminants from aqueous solution. In this work, models that predict the sorption of arsenic, boron, and selenium from water using cation-exchanged zeolites. Because of the lack of experimental adsorption data for these species of contaminants, models were parametrized to reproduce the results of first-principles calculations and then used to predict sorption for zeolites for a dataset containing 6000 combinations of zeolites and sorption conditions. Machine learning was used to train a model to predict sorption for materials in this database based on the results of the molecular simulations. Next, a genetic algorithm was used to optimize zeolites for the removal of each contaminant from aqueous solution for individual impoundment sites based on contaminant concentrations reported by the Electric Power Research Institute.
This progress report (Level 3 Milestone Number M3SF-25LL010302052) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Crystalline Host Rock Properties & Processes - LLNL Number SF-25LL01030205. Observed changes in radionuclide sorption after bentonite/clay heating have implications for radionuclide diffusive transport through engineered barriers and must be considered when designing waste disposal repositories. Recent research performed at Los Alamos National Laboratory (LANL) has provided key insights regarding the hydrothermal alteration behavior of bentonite backfill in the presence of repository materials (steel, concrete, etc.). We are examining how this mineral alteration affects retardation behavior of a suite of radionuclides of interest to repository performance assessment. Sorption experiments and data analysis for 233 U were initiated in FY24 following earlier experiments performed on 243 Am, 90 Sr, 137 Cs. In FY25, we completed the 233 U study and initiated and completed a study of 237 Np sorption. Below, we summarize the results and potential impacts of hydrothermal alteration on radionuclide retardation and assess the importance of this process to radionuclide migration from a GHRDC. We also use statistical tools (i.e. PCA) to help us determine the major drivers in affecting changes in measured Kd values induced by hydrothermal alteration. These experiments also allow us to test the predictive ability of our component additivity approach to surface complexation and ion exchange. Our guiding hypothesis is that a robust surface complexation/ion exchange model and associated database can effectively predict changes in radionuclide sorption behavior resulting from the hydrothermal alteration of mineralogy in a repository near field. In November 2024 the paper “Selenium interaction with iron minerals: Quantitative comparison of sorption and coprecipitation impacts on mobility” was published in Applied Geochemistry. A short update of results to date is presented below. In FY25, we also actively supported the DITUSC project, which is part of the EURADII initiative, as associate partners. We are executing the Migration2025 conference and support associated the NEA-TDB and Thermochimie workshops that will provide critical international engagements and develop consensus and synergy in thermodynamics as it relates to supporting the US nuclear waste repository program.
A study was conducted to evaluate sorbent technologies that can mitigate the presence of elemental mercury (Hg⁰) in waste containers for mercury-contaminated debris (MCD). Decontamination and demolition (D&D) activities at the Y-12 National Security Complex (Y-12) and other U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR) facilities generate MCD requiring offsite disposal. The debris is packaged in appropriate waste containers and may be temporarily stored onsite prior to transport for treatment and/or disposal. During transportation of loads that had no visible liquid Hg at the point of origin, temperature changes can cause Hg⁰ to evaporate, condense, and form droplets on container walls. Furthermore, vibration during transportation could cause beads of Hg to be released from the debris, container walls, and ceiling, resulting in pools of liquid Hg⁰ on the container floor. Waste acceptance criteria (WAC) limitations for commercial disposal facilities, the Nevada National Security Site (NNSS), and ORR mixed low-level waste landfills prohibit the presence of any free liquids in containers identified as a solid waste form. Potential solutions to mitigate the presence of residual liquids that could be formed through vapor condensation include the use of sorbents or similar materials to capture and stabilize volatile Hg⁰ vapors and thus ensure compliance with landfill WAC requirements. This report summarizes data from small-scale laboratory experiments conducted to evaluate sorbent materials for Hg⁰ vapor suppression and sorption of liquid Hg⁰ that could form under relevant transportation and disposal conditions. A series of experiments was conducted to evaluate commercial sorbent materials and their effectiveness for Hg⁰ sorption across a temperature range from 19.4°C to 60°C. The impact of residual moisture on sorption was investigated under relevant conditions, and leaching tests were performed to assess the stability of Hg⁰ captured sorbent materials. The results provide estimates for sorbent quantities needed for a given Hg⁰ mass loading based on experimental results exposing sorbents to gaseous and liquid Hg⁰ at various mass ratios. Overall, sorbents that were most effective for Hg⁰ vapor suppression were brominated activated carbons, mackinawite-based sorbents coated on vermiculite, and sulfur-modified granular activated carbon. Elevated temperatures and moisture conditions did not result in significant increases of Hg⁰ headspace concentrations, and the materials also demonstrated high sorption capacities for the sorption of liquid Hg⁰.
An enhancement of hydrophilicity for chlorided aluminas was demonstrated by the results obtained from gaseous H2O sorptions at 70-, 80-, and 86-percent relative humidity on alpha and gamma aluminum oxide particulates and on alpha and gamma aluminum oxide particulates with a chemisorbed surface chloride phase (produced by reactions of gaseous HCl + H2O on alumina). Continuous sorption histories for H2O on chlorided aluminas having specific surface areas that range from 7 to 227 sq m/g before chloriding indicated that initial sorption rates were directly linked to the extent of chemisorbed chlorided coverage and implied the same relationship for sorption capacities. The initial sorption rate on chlorided aluminas was found to be slower for the first exposure to H2O than for subsequent exposures (which reached equilibrated H2O coverages much faster), suggesting that slow chemical reactions between H2O and chlorided alumina may have been operative during initial exposures. Chlorided alumina particles were found to remain very hydrophilic (relative to nonchlorided analogs) for several H2O sorption/desorption cycles.
Results are presented on the development of a reversible carbon sorbent for trace-contaminant (TC) removal for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is deemed non-regenerable, while the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on concurrent sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, are presented in this paper. A carbon sorbent was fabricated by dry impregnation of a reticulated carbon-foam support with polyvinylidene chloride, followed by carbonization and thermal oxidation in air. Sorbent performance was tested for ammonia and formaldehyde sorption and vacuum regeneration, with and without water present in the gas stream. It was found that humidity in the gas phase enhanced ammonia-sorption capacity by a factor larger than two. Co-adsorption of ammonia and formaldehyde in the presence of water resulted in strong formaldehyde sorption (to the point that it was difficult to saturate the sorbent on the time scales used in this study). In the absence of humidity, adsorption of formaldehyde on the carbon surface was found to impair ammonia sorption in subsequent runs; in the presence of water, however, both ammonia and formaldehyde could be efficiently removed from the gas phase by the sorbent. The efficiency of vacuum regeneration could be enhanced by gentle heating to temperatures below 60 deg.
Catechol and hydroquinone are widely present hydroxybenzene isomers in the natural environment that induce environmental toxicities. These hydroxybenzene compounds can be effectively removed by manganese (Mn)-oxides via sorption and oxidative degradation processes. In the present study, we investigated the structure–reactivity relationships in the sorption and oxidation of catechol and hydroquinone on Mn-oxide surfaces. Two widely present Mn-oxides, including hydrous Mn oxide (HMO) and cryptomelane, comprised of layer and tunnel structures, respectively, are specifically studied. Effects of Mn-oxide structures and environmental pH conditions on the removal efficiency of these hydroxybenzene compounds, via sorption and oxidative degradation, are investigated. Cryptomelane, which has a higher specific surface area than HMO, possesses a higher sorption and oxidation capacity. The complexation mechanisms of catechol and hydroquinone vary due to their structure-induced difference in reactivity. Catechol reduced and dissolved more Mn from Mn-oxides than hydroquinone, accompanied by a higher C loss of catechol-C, suggesting a higher reactivity of catechol. Structural changes occurred in the Mn-oxides resulting from reaction with catechol and hydroquinone: reduction of Mn(IV), corresponding formation of Mn(III) and Mn(II) in the mineral, and free Mn 2+ ions released into the suspension. Finally, these insights could help us better understand and predict the fate of hydroxybenzene compounds in Mn-oxide-rich soils and wastewater treatment systems that generate Mn-oxides via Mn removal and the associated environmental toxicity.
This paper focuses on the influence of the grain size of a geopolymer based adsorbent on its Cs + adsorption performances both in batch and fixed-bed process. The geopolymer phase was used as a binder to support NaY zeolite particle in a 20 wt% charged porous composite with 160 m 2 .g –1 of porous surface area. These samples were shaped with three grain sizes (50 /100/500 µm) to remove 80–90 mg/g of Cs + in batch and column operations. After their microstructural and porous characterizations, their efficiency and adsorption characteristics were investigated through adsorption isotherms and kinetic in the two processes. While the grain size has no influence on the maximal extraction capacity of the adsorbent, it strongly affects the sorption kinetic. By coupling experimental data and a modelling approach, the complex sorption mechanism was highlighted, suggesting a new insight of the contaminant sorption kinetic. Then, comparison of batch and column adsorption experiments illustrates the detailed explanation of various process parameters for column study. The results show challenges for fixed-bed column utilization by the choice of the appropriate grain size as a compromise between the material sorption kinetic and hydrodynamic considerations. Furthermore, this is of high importance to more accurately optimize the design of column adsorption to assess the transport of Cs+ in multi-porous tailored grain size materials.