Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Exploring Offshore Regional Atlantic Carbon Storage and Infrastructure for Eastern USA (Supporting Communities and Industry for Mid-Atlantic Offshore Carbon Storage Hub)

This final technical report presents a summary of work completed for the project Supporting Communities and Industry for Mid-Atlantic Offshore Carbon Storage Hub (FE0032407), which has been designated EXPLORE-ACS (Exploring Potential Long-Term Offshore Regional Atlantic Carbon Storage). The project is part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) funding opportunity announcement 2799 for Regional Initiatives to Accelerate Carbon Capture, Utilization, and Storage (CCUS) Deployment. The objective of the DOE 2799 program is to identify and address the challenges facing commercial deployment of carbon capture, transport, and storage in specific regions of the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing flexibility for climate change using seasonal energy storage (aquifer thermal energy storage) in distributed energy systems

Long-term energy storage is expected to play a vital role in the deep decarbonization of building energy sectors, while enhancing the flexibility of buildings to withstand future climate variations. However, it is challenging to design distributed multi-energy systems (DMES) while taking into account the uncertainties introduced by climate change, since stochastic optimization of such systems is difficult. The present study introduces a stochastic optimization model to address this bottleneck, taking into account DMES including aquifer thermal energy storage (ATES) as the long-term thermal storage. For the first time, a novel optimization algorithm links ATES with the DMES optimization model with the support of a simplified geotechnical model. Subsequently, a case study was conducted, focusing on a residential district in Chicago where the impact of future climate condition, energy demand, and solar and wind energy potentials were evaluated using Weather Research and Forecasting (WRF) data (up to 2080) and the EnergyPlus model. The study revealed that ATES is an attractive way to improve the renewable energy penetration level and minimize the dependence on fossil fuels with reasonable support from the grid to assist the fluctuations in both demand and generation. Furthermore, ATES notably reduces fuel consumption and dependence while greatly enhancing the flexibility of the energy system to withstand fluctuations in demand and renewable energy generation brought by future climate variations. These qualities will make ATES an important part of distributed energy systems, even though it is not currently the lowest cost alternative due to lack of technology maturity. Furthermore, the design platform introduced in the present study can be used to design DMES enhancing flexibility to accommodate future climate variations.

25 ENERGY STORAGE↗

Fuel Aging in Storage and Transportation (FAST): Accelerated Characterization and Performance Assessment of the Used Nuclear Fuel Storage System

This Integrated Research Project (IRP) was established to characterize key limiting phenomena related to the performance of used nuclear fuel (UNF) storage systems. This was an applied engineering project with a specific application in view (i.e., UNF dry storage). The completed tasks made use of a mixture of basic science and engineering methods. The overall objective was to create, or enable the creation of, predictive tools in the form of observation methods, phenomenological models, and databases that will enable the design, installation, and licensing of dry UNF storage systems that will be capable of containing UNF for extended period of time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Economic Long-Duration Electricity Storage by Using Low-Cost Thermal Energy Storage and High-Efficiency Power Cycle (ENDURING)

The project involved considerable industry participation including General Electric (GE, power cycle analysis), Babcock & Wilcox (B&W), Allied Mineral Products (insulation materials), and Worley-Advisian (system integration). They provided insights on their products or services for component and system designs. The project successfully achieved the project goals of demonstrating technology feasibility for long duration energy storage with a technology path towards 5c/kWh levelized cost of storage. The project has generated four patent applications (one awarded patent and three under review), three published journal papers, a draft book chapter, and five manuscripts under preparation, with several conference papers and numerous presentations including invited talks. An intellectual properties (IP) option agreement has been signed with an U.S. manufacturer, with interests from energy developers. Four related projects with $5.5 million DOE funding support more developments for long duration energy storage and broad industry decarbonization.

25 ENERGY STORAGE↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗

A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Impacts of Storage Faults on HPC Applications: A methodology and insights

In recent years, the increasing complexity in scientific simulations and emerging demands for training heavy artificial intelligence models require massive and fast data accesses, which urges high-performance computing (HPC) platforms to equip with more advanced storage infrastructures such as solid-state disks (SSDs). While SSDs offer high-performance I/O, it remains unclear about the reliability challenges faced by the HPC applications under the SSD-related failures, in particular, failures resulting in data corruptions. The goal of this paper is to understand the impact of SSD-related data corruptions on the behaviors of complex HPC applications. To this end, we propose FFIS, a FUSE-based fault injection framework that systematically introduces storage faults into the application layer to model the errors originated from SSDs. FFIS is able to plant different I/O related faults into the data returned from underlying file systems, which also enables the investigation on the error resilience characteristics of the scientific file format for the first time. We demonstrate the use of FFIS with three representative real HPC applications, show how each application reacts to the data corruptions, and provide insights on the error resilience of the widely-adopted HDF5 file format for the HPC applications.

Fang, Bo↗

Secondary Use-Plug-and-Play Energy Storage System Composed of Multiple Energy Storage Technologies

Low-cost, grid-connectable energy storage technologies represent a significant challenge for the electric grid of the future. Energy storage technologies are in rapid development with targets to reduce the storage medium cost. However, a significant cost to deployment also comes in the integration. This paper presents the development of a plug-and-play system for supporting secondary use multiple battery systems into a single grid connectable unit. Results of the system design are demonstrated in a controller hardware in the loop (CHIL) platform. Simulations of two energy storage systems operating in parallel and dispatched optimally are presented.

Starke, Michael↗

Does More Storage Give California More Water?

Abstract Increasing reservoir storage is commonly proposed to mitigate increasing water demand and provide drought reserves, especially in semiarid regions such as California. This paper examines the value of expanding surface reservoir capacity in California using hydroeconomic modeling for historical conditions, a future warm‐dry climate, and California's recently adopted policy to end groundwater overdraft. Results show expanding surface storage capacity rarely provides sizable economic value in most of California. On average, expanding facilities north of California's Delta provides some benefit in 92% of 82 years modeled under historical conditions and in 61% of years modeled in a warm‐dry climate. South of California's Delta, expanding storage capacity provides no benefits in 14% of years modeled under historical conditions and 99% of years modeled with a warm‐dry climate. Results vary across facilities between and within regions. The limited benefit of surface storage capacity expansion to statewide water supply should be considered in planning California's water infrastructure.

Nover, D. M.↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

A Software Defined Storage Approach to Exascale Storage Services (Final Technical Report)

The Mochi project began in 2015 in recognition of a set of changes that were set to alter the landscape of storage and I/O for DOE science. On the one hand, an influx of new classes of applications including an initial set of data intensive and machine learning applications were operating with new types of data and in new ways, as compared to traditional computational science simulation codes. Simultaneously, new memory, storage, and networking technologies were driving a need to adapt software designs to a rapidly changing design space. The goal of the three-year Mochi project was to develop and demonstrate an approach for composing storage services which provides new levels of functionality, performance, and reliability for science applications at extreme scale. The team, including a mix of Laboratory, university, and industry collaborators, focused on systems and applications of interest to DOE Office of Science, tracking developments at NERSC and the LCFs as well as application trends within ECP and SciDAC. Technical work focused on three themes: composition (understand the building blocks needed to provide storage services that meet DOE mission needs and how these components are flexibly composed), application interfacing (what service compositions are most effective for common DOE application use cases), and consistency and synchronization (taking advantage of knowledge about, and from, the system and scientific applications to provide better service than would otherwise be possible). The project was highly successful, producing 13 publications and tens of thousands of lines of open source software that is now being used by multiple ECP teams, HPC software vendors, and international collaborators. The uptake of Mochi technologies speaks to both the value of the service composition model and the quality of architecture and software developed by the team. Through continued funding under ASCR and ECP, the Mochi team and its technologies are on track to further contribute to DOE science successes into the exascale timeframe.

97 MATHEMATICS AND COMPUTING↗

Storage 2020: A Vision for the Future of HPC Storage

The explosive growth in data over the next five years that will accompany exascale simulations and new experimental detectors will enable new data-driven science across virtually every domain. At the same time, new nonvolatile storage technologies will enter the market in volume and upend long-held principles used to design the storage hierarchy. The disruption that these forces will bring to bear on high-performance computing (HPC) will also create significant opportunities to innovate and accelerate scientific discovery. To ensure that NERSC fully capitalizes on these opportunities, we have developed a comprehensive vision for the future of storage in HPC and identified short- and long-term strategic goals to effectively realize this vision. This report presents the results of this effort and offers a blueprint for designing a storage infrastructure for supporting HPC through 2025 and beyond.

97 MATHEMATICS AND COMPUTING↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

GE networked mass storage solutions supporting IEEE network mass storage model

The General Electric Government Communications Systems Department (GE/GCSD) has developed a near real time digital data storage and retrieval system that extends the capabilities currently available in today's marketplace. This system called DuraStore uses commercially available rotary tape drive technology with ANSI/IEEE standards for automated magnetic tape based data storage. It uses a nonproprietary approach to satisfy a wide range of data rates and storage capabilities requirements and is compliant with the IEEE Network Storage Model. Rotary tape drives, standard interfaces, application specific hardware/software, networked automated tape libraries, library administrator, write protection, volume/physical media linkages, and maximum resource utilization are addressed.

Herzog, Donald↗