Grinding of additively manufactured silicon carbide surfaces for optical applications

Many of the properties of Silicon carbide (SiC) are advantageous for optical applications, such as telescope mirrors and industrial laser systems. However, the base shapes of complex components are costly and difficult to manufacture. Leveraging additive manufacturing, near net complex components are readily processed. In this work, we investigate the post processing of additively manufactured SiC (AM SiC) compared to chemical vapor deposited (CVD) SiC. The specific grinding energy for the AM SiC was lower than CVD, however the trends were the same. A specular finish was observed on both materials but the AM SiC finish was limited due to residual porosity.

36 MATERIALS SCIENCE↗

Spectroscopy of Palladium Nanoparticle Synthesis: Tailoring Nanoparticle Growth Parameters for Hydrogen Storage

Using palladium for hydrogen storage requires palladium (Pd) particles exhibiting specific parameters, including surface area, particle size, and particle shape, with increased interest in palladium nanoparticles (Pd NPs). In order to routinely monitor the synthesis of these particles a spectroscopic method is being developed using infrared (IR), Raman, and UV-Vis spectroscopy. By monitoring the production of Pd NPs, the growth of the NPs can be controlled to ensure quality of the product to match the desired finished particle specifications. For the reaction presented, the conversion of the intermediate tetraamminepalladium(II) chloride (PTC) to diamminepalladium(II) chloride (PDC) can influence the Pd NPs properties. This study is first being developed in lab bench scale quantities to allow ultimate control of the Pd NPs.

08 HYDROGEN↗

Separation characteristics of cations and natural organic matter in electrodialysis

Natural organic matter (NOM) in water can cause the formation of disinfection byproducts (DBPs) when NOM reacts with a disinfectant such as chlorine. Nanofiltration (NF) and reverse osmosis (RO) are effective treatment methods to remove NOM. However, the simultaneous presence of both NOM and divalent cations such as Ca 2+ can enhance fouling in NF and RO. Therefore, an appropriate pretreatment to remove such cations before NF or RO would delay fouling and perhaps improve water recovery and NOM removal efficiency. Electrodialysis (ED) is potentially an excellent pretreatment method because it separates inorganic ions well using ion exchange membranes (IEMs) but does not separate NOM well because of its size and consequent low diffusivity. This research focused on ion and NOM separation with ED using three different types of commercially available IEM pairs, two different commercially available NOM sources, and six different influents at 500 mg/L total dissolved solids in the presence or absence of both hardness (Ca 2+ and Mg 2+ ) and NOM. The target waters of interest in this research were drinking water supplies that require little or no desalination but substantial removal of NOM; after NOM separation in NF or RO, some or all of the ED concentrate can be added to the NF/RO permeate to create the finished water prior to disinfection. The results indicate that ED can effectively separate alkaline earth metal ions without separation of NOM. Cation exchange membranes with high exchange capacity, high selectivity for divalent cations are desirable, and both anion and cation exchange membranes should have low affinity for organic adsorption. As a result, the process would work particularly well for NOM with relatively low hydrophobicity, since NOM adsorption to most surfaces increases with hydrophobicity.

36 MATERIALS SCIENCE↗

Semi-transparent p-type barium copper sulfide as a back contact interface layer for cadmium telluride solar cells

Optically transparent p-type materials play a critical role in transparent electronics including photovoltaic (PV) devices. P-type sulfide materials offer an alternative to oxides for PV application due to improved hole transport properties. Here, we report the solution-based synthesis of earth-abundant p-type transparent conducting barium copper sulfide (α-BaCu 4 S 3 , BCS) thin films. These films were characterized using scanning electron microscopy, X-ray diffraction, UV–Vis–NIR spectrophotometry, Raman spectroscopy, and spectroscopic ellipsometry. BCS films of ~100 nm thickness transmit >70% of visible light. We report on tests of the hole transport properties of these BCS films for cadmium telluride (CdTe) photovoltaics, finding that the BCS deposition process forms a beneficial tellurium (Te) rich surface on CdTe by selectively removing Cd from the surface. Based on our study, the BCS interface layer plays dual functions for CdTe PV devices as a hole transport material and as an etchant, enhancing the resulting device performance. We observed a significant increase in open-circuit voltage of CdTe solar cells with the BCS buffer layer. Furthermore, we discuss semitransparent CdTe solar cells with BCS as a hole transport layer and indium tin oxide as a finishing electrode. Semitransparent CdTe solar cells shows 13.3% conversion efficiency for the front side illumination and 1.2% efficiency for back side illumination, indicating high recombination of charge carriers generated close to the rear CdTe/BCS/ITO contact.

36 MATERIALS SCIENCE↗

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Nanostructured Black Nickel Coating as Replacement for Black Cr(VI) Finish

This work compares different electrodeposition procedures to produce nickel black coatings as greener and less toxic alternatives to Cr(VI)-based coatings used in different applications. Nickel and nickel-plated brass served as substrates in studies with a Hull cell and polarization curves. After a set of comparative experiments, the best electrodeposition procedure was further studied and optimized. Optimal conditions were found with a bath consisting of 75 g/L NiCl2·6H2O + 30 g/L NaCl and a current density of 0.143 A dm−2 applied for 5 min at room temperature. Furthermore, a pre-treatment with 18.5 vol.% of hydrochloric acid in water was found to be necessary to warrant good coating adhesion to the substrate. The black color is attributed to the development of a nanostructured surface that absorbs the incident light. Corrosion testing was performed in 0.5 M NaCl aqueous solution using electrochemical impedance spectroscopy (EIS) and polarization tests.

Mennucci, Marina M. (ORCID:0000000171886804)↗

Advanced Mixed Waste Treatment Project Overcomes Challenges to Complete Treatment of Debris Waste - 20616

The Advanced Mixed Waste Treatment Project (AMWTP), operated by Fluor Idaho for the Department of Energy Idaho Operations Office, completed the last of its debris waste treatment in the fall of 2019. Concluding that work-scope was certainly not without its challenges. Fluor Idaho and its employees had to adapt to treating extremely challenging waste types, such as high-fissile gram materials and potentially pyrophoric and reactive wastes coming down the stretch. It also had to complete the sizing of large waste boxes from Mound Laboratories in inner-contamination enclosures designed to capture the extremely fine, 'flighty' plutonium-238 in its high-efficiency particulate air filters. Very few waste treatment facilities in the DOE Complex have completed their missions. In fact, most large-scale waste treatment facilities are still under construction with many months or years remaining before 'hot operations' begin. AMWTP is unique because it functioned as a 'one-stop shop.' Transuranic and low-level waste characterization, treatment, certification, and shipping all occurred there. AMWTP concluded the most challenging part of its mission and will continue to ship material out of the state of Idaho for the next decade. This paper will provide a background of the AMWTP mission, and the adaptations to its operating permit, equipment, or treatment processes to address challenging waste types. AMWTP will leave behind a legacy of being one of the most successful waste treatment facilities in the history of the DOE Complex. The facility was well-conceived, well-constructed, and well-executed; it was done right from start to finish. During the course of its waste treatment mission, the facility was required to adapt to changing conditions by treating extremely challenging waste types. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Calibrated Modeling of Residual Stresses Induced in Machining under Various Cooling and Lubricating Environments

Although many functional characteristics, such as fatigue life and damage resistance depend on residual stresses, there are currently no industrially viable ‘Digital Process Twin’ models (DPTs) capable of efficiently and quickly predicting machining-induced stresses. By leveraging advances in ultra-high-speed in-situ experimental characterization of machining and finishing processes under plane strain (orthogonal/2D) conditions, we have developed a set of physics-based semi-analytical models to predict residual stress evolution in light of the extreme gradients of stress, strain and temperature, which are unique to these thermo-mechanical processes. Initial validation trials of this novel paradigm were carried out in Ti-6Al4V and AISI 4340 alloy steel. A variety dry, cryogenically cooled and oil lubricated conditions were evaluated to determine the model’s ability to capture the tribological changes induced due to lubrication and cooling. The preliminarily calibrated and validated model exhibited an average correlation of better than 20% between the predicted stresses and experimental data, with calculation times of less than a second. Based on such fast-acting DPTs, the authors envision future capabilities in pro-active surface engineering of advanced structural components (e.g., turbine blades).

36 MATERIALS SCIENCE↗

Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)

The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.

54 ENVIRONMENTAL SCIENCES↗

Survey of the mechanical and physical behaviors of yttria-stabilized zirconia from multiple dental laboratories

Background: When selecting zirconia for a dental restoration, laboratory prescriptions often refer to high strength and high translucency. In this survey, zirconia specimens were ordered from various dental laboratories for posterior (high strength) and anterior (high translucency) clinical indications. The specimens were then tested and evaluated for their mechanical and physical behaviors. Methods: In a double-blinded manner, 9 laboratories provided 32 specimens from 17 different zirconia blanks, which were tested in the American Dental Association laboratory. Flexural strength tests were performed on standard specimens, and fracture surfaces were examined using both optical and scanning electron microscopy. Chemical composition, Vickers hardness, and absolute transmittance measurements were also performed. Results: A large scatter in the strength values was observed. The zirconia intended for posterior applications displayed strengths (SD) from 195 through 783 MPa (490 [183] MPa), which overlapped greatly with the strengths (SD) of the zirconia intended for anterior applications, 320 through 768 MPa (581 [136] MPa). However, when the strength values were recalculated on the basis of yttria content, the strengths (SD) were 584 (158) MPa for 3 mol% yttria and 373 (104) MPa for 5 mol% yttria. Conclusions: When a prescription was given to dental laboratories to request zirconia on the basis of clinical requirements, there was a large scatter and no consistency in the resulting strength values partly because of mixed use of 3 mol% and 5 mol% yttria zirconia. The 3 mol% materials had much higher strength when the strength values were grouped according to yttria content. Strength was also highly dependent on processing and finishing at the dental laboratories.

3 mol% yttria-tetragonal zirconia polycrystal (3Y-↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

Data and scripts associated with: “Burn severity and vegetation type control phosphorus concentration, molecular composition, and mobilization”

This data package is associated with the publication “Burn severity and vegetation type control phosphorus concentration, molecular composition, and mobilization” published in European Geophysical Union - Biogeosciences (Barnes et al. 2025). This study investigates how phosphorus (P) biogeochemistry is altered by burn severity in contrasting types of vegetation chars. This data package documents the workflow used to process and generate the main figures and statistics in the manuscript. The R scripts reference minimally processed P nuclear magnetic resonance (P-NMR) and X-ray absorption near edge structure (P-XANES) data, as well as fully processed data including total elemental composition of the solid chars, total elemental composition of the char leachates (particulate and aqueous phases), and leachate aqueous phase molybdate reactive P concentration. These source data and associated metadata can be found on ESS-DIVE at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1894135 (Grieger et al. 2022; v3). Files and scripts included in this data package finish the processing workflow for P-NMR and P-XANES data. These data can be used to gain a better understanding of bulk chemical changes in chars and their leachates, as well as detailed molecular changes to P. This data package is associated with the GitHub repository found at https://github.com/river-corridors-sfa/rcsfa-RC3-BSLE_P. This data package is comprised of a “data” folder and a series of data processing and analysis scripts. Details on how to recreate the workflow can be found in the Critical Details section of the readme and the “workflow_readme.md” file. The file-level metadata file (file ending in “flmd.csv”) lists all files contained in this data package and descriptions for each. The data dictionary (file ending in “dd.csv”) describes all tabular data columns and their respective definitions and units.

54 ENVIRONMENTAL SCIENCES↗

Lessons Learned from Demolition of Hanford's Plutonium Finishing Plant - 20507

U.S. Department of Energy (DOE) contractor CH2M Hill Plateau Remediation Company (CHPRC), a Jacobs owned company, is making significant progress demolishing the Plutonium Finishing Plant (PFP), which has long been known as one of the most hazardous buildings in the DOE Environmental Management Complex (DOE Complex). The facility is located on the Hanford Site and produced plutonium metal during the Cold War. Production was stopped in 1989, the facility was formally shut down in 1996, and material processing was completed in 2004. After approximately 25 years of demolition preparations, open-air demolition of the main portions of the Hazard Category II nuclear facility began in November 2016. To prepare the PFP for demolition, CHPRC employees performed some of the most hazardous work across the DOE Complex. In addition to extensive demolition preparations, including a wide-reaching communication strategy across the Hanford Site, CHPRC implemented robust controls and monitoring during demolition, and when necessary, adjusted demolition practices and sequence to maintain employee safety and project efficiency. Demolition of the main PFP building began in November 2016. The technical complexity, high hazards and radiological concerns have all led to a difficult demolition environment. Following a spread of contamination at the project site beyond the radiological boundaries in December 2017, work was halted and a recovery plan was generated to allow the demolition work to continue. After the implementation of additional controls and concurrence from regulatory agencies and DOE, the demolition was ready to resume work and reinitiated in August 2018. There are a number of lessons learned from the demolition activities and recovery plan process. This paper allows CHPRC and DoE's Richland Operations Office (RL) to share lessons learned and progress to date with other challenging and hazardous projects across the DOE Complex. Understanding the risk acceptance level is critical to execution of any open-air demolition project and is unique to each facility. Four key lessons learned from this project include: 1) plan execution issues, 2) stakeholder communication issues, 3) watching for summit fever and 4) minimizing exposed contaminated surfaces during demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AI-Enabled Discovery and Physics-Based Optimization of Energy Efficient Processing Strategies for Advanced Turbine Alloys (Final Technical Report)

In this project, the multi-organizational team of academic and industrial researchers from the University of Kentucky an aerospace and energy generation OEM partner has leveraged novel Digital Process Twin (DPT) models of process/structure interactions (i.e., process-induced surface integrity) to advance a paradigm of fully integrated computational materials engineering (ICME). Using efficient process models as the core of a digital process simulator for a reinforcement learning algorithm, the team has integrated industrial data and metrics of structure/performance/energy relationships and manufacturing-related energy metrics to optimize dynamic processing parameters for significantly improved life-cycle energy efficiency of advanced γ-TiAl low-pressure turbine (LPT) alloys, as indicated by a set of design relevant parameters (e.g., residual stresses and scrap rate). The key objective and anticipated outcome of the project was at least a 10% reduction in life-cycle embodied energy for a recently developed, γ-TiAl low-pressure turbine (LPT) alloy and nickel-based superalloy Inconel 718, through the adoption of the proposed AI-enabled process optimization approach. The final project outcomes significantly exceeded this original target, realizing manufacturing-related energy efficiency improvements of more than 130% for TiAl and up to 80% for Inconel 718. Rather than following the prevailing and highly inefficient empirical paradigm, the proposed study demonstrated the feasibility of adopting a digital, physics-based process design and optimization paradigm. The recurring need for manual intervention, rework, reinspection causes significant production bottlenecks and unnecessary expense associated with delivering the requisite component quality. The OEM partner, and turbine industry in general, expect to reap significant cost and resource savings if an AI-optimized set of parameters can be applied to specific machining operations. The technical scope of the proposed project involved the paving of a realistic path towards model-based and AI-enabled Integrated Computational Materials Engineering (ICME), and away from inefficient empirical process optimization and legacy manufacturing practices, which are no longer able to efficiently process novel high-performance turbine alloy materials. The project team will address the fundamental knowledge gap that currently exists within the ICME paradigm with respect to the process/structure/performance/energy impacts of finishing processes. While significant resources have been devoted to the ‘early stages’ of manufacturing, such as alloy design, primary and secondary processing, finishing processes have not been adequately integrated within ICME. To provide an actionable path towards model-based finishing process design (e.g., machining, burnishing, grinding, polishing), we will employ a novel AI-enabled process optimization paradigm, based on a computationally efficient, physics-based process simulator. Through limited experimental work to calibrate and validate our process simulator model via an advanced in-situ characterization technique and process optimization via reinforcement learning, the project will seek to demonstrate a viable alternative to the inefficient ‘legacy’ processing strategies, empirical testing and broad scope machining learning approaches, all of which fail to adequately consider complex process physics. The project team has identified an intermetallic γ-TiAl LPT alloy, which is currently being used as part of the OEM partner’s advanced gas turbine designs. This particular alloy poses significant manufacturing challenges during finishing operations, which limit the degree to which the current turbine design can be manufactured in an energy- and cost-efficient manner. Empirical testing and numerical modeling efforts to optimize processing parameters for γ-TiAl have not been able to resolve these manufacturing challenges, so the proposed physics-based AI-enabled optimization technology would offer a truly novel and transformative capability. The multi-organizational team of academic and industry experts from the UKY and the OEM partner will work together closely to demonstrate the analytical and experimental critical function and characteristic proof of concept of this novel approach.

20 FOSSIL-FUELED POWER PLANTS↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.