Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Efficient data acquisition and training of collisional-radiative model artificial neural network surrogates through adaptive parameter space sampling

Abstract Effective plasma transport modeling of magnetically confined fusion devices relies on having an accurate understanding of the ion composition and radiative power losses of the plasma. Generally, these quantities can be obtained from solutions of a collisional-radiative (CR) model at each time step within a plasma transport simulation. However, even compact, approximate CR models can be computationally onerous to evaluate, and in-situ evaluation of these models within a larger plasma transport code can lead to a rigid bottleneck. As a way to bypass this bottleneck, we propose deploying artificial neural network (ANN) surrogates to allow rapid evaluation of the necessary plasma quantities. However, one issue with training an accurate ANN surrogate is the reliance on a sufficiently large and representative training and validation data set, which can be time-consuming to generate. In this work we explore a data-driven active learning and training routine to allow autonomous adaptive sampling of the problem parameter space to ensure a sufficiently large and meaningful set of training data is assembled for the network training. As a result, we can demonstrate approximately order-of-magnitude savings in required training data samples to produce an accurate surrogate.

97 MATHEMATICS AND COMPUTING↗

Analysis of Organic Electron Materials using Neutron Scattering (Final Report)

Neutron scattering is a powerful suite of measurement techniques that enable unique analysis of structure and dynamics of a wide variety of materials. Specifically, neutrons interact strongly with protons, which enables excellent contrast in light element organic materials that cannot be obtained with any other measurements. This series of three proposals focused on using inelastic neutron scattering (INS) to study the vibrations (dynamics) of the organic molecules involved in organic electronic devices. Our main goals were to demonstrate that INS is capable of elucidating new, useful, and unique knowledge about organic electronic samples that could be used to improve the function of devices or to solve outstanding problems that could not be solved using other measurement techniques. Since all of the goal involved using INS or other neutron techniques to do something “new” a large part of the effort was focused on complex data interpretation and development of modeling workflows that could be used by other members of the organic electronics community to study their materials. To facilitate the goal of making INS measurements more accessible to a broader community and for a wider range of materials, we optimized and engineered the computational workflows to be well documented, publicly available, and user friendly. The individual titles of the three sequential DOE-BES awards are: (1) Engineering doping profiles in organic semiconducting materials, (2) Measurement and modeling of molecular dopant structure and dynamics, and (3) Quantification of Dynamic Disorder in Electronic and Excitonic Organic Materials. For readability, this report is organized to highlight the progress of the research thematically. Many of the ideas started in one grant period and then spilled over into later awards and collaborative research.

36 MATERIALS SCIENCE↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

Bioelectrochemical crossbar architecture screening platform for extracellular electron transfer

Electroactive microbes can serve as living components in bioelectronic devices, where their unique ability to transfer electrons enables applications in sensing, energy conversion, and synthesis, but they remain challenging to engineer because the bioelectrochemical systems (BESs) used for characterization are low throughput. Here, we present a bioelectrochemical crossbar architecture screening platform (BiCASP) that uses stacked and orthogonally arrayed electrodes to enable individual sample selection for characterization in arrayed formats. This device reports on the current generated by electroactive bacteria on the minute timescale, decreasing the time for data acquisition by several orders of magnitude compared to conventional BESs. This device increases the throughput of screening engineered biological components in cells, identifying mutants of the membrane protein wire MtrA in Shewanella oneidensis that retain the ability to support extracellular electron transfer (EET). BiCASP may be integrated with bioelectronics that need directed evolution of electroactive proteins.

Shewanella↗

Effect of particle characteristics on the evolution of particle size, particle morphology, and fabric of sands loaded under uniaxial compression

This work presents the results and analyses of uniaxial compression experiments performed on three silica sands. The sands have comparable particle-size distributions, but their particles differ in morphology and strength. Cylindrical samples of the three sands were compressed in a loading device placed inside an X-ray microscope (XRM) and scanned at multiple stress levels during uniaxial compression. 3D tomography data of the samples obtained from the XRM at different stress levels were then analyzed to obtain the distributions of particle size, particle morphology, and interparticle contact normals within the sample. Results indicate that: (1) the compressibility of the sands loaded under uniaxial compression is closely tied to particle morphology and strength and (2) the anisotropy in the orientations of interparticle contact normals generally increases with axial stress; however, this increase is limited by the occurrence of particle crushing in the sample.

3D X-ray computed tomography↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Beam-driven dynamics of aluminium dopants in graphene

Abstract Substituting heteroatoms into graphene can tune its properties for applications ranging from catalysis to spintronics. The further recent discovery that covalent impurities in graphene can be manipulated at atomic precision using a focused electron beam may open avenues towards sub-nanometer device architectures. However, the preparation of clean samples with a high density of dopants is still very challenging. Here, we report vacancy-mediated substitution of aluminium into laser-cleaned graphene, and without removal from our ultra-high vacuum apparatus, study their dynamics under 60 keV electron irradiation using aberration-corrected scanning transmission electron microscopy and spectroscopy. Three- and four-coordinated Al sites are identified, showing excellent agreement with ab initio predictions including binding energies and electron energy loss spectrum simulations. We show that the direct exchange of carbon and aluminium atoms predicted earlier occurs under electron irradiation, although unexpectedly it is less probable than the same process for silicon. We also observe a previously unknown nitrogen–aluminium exchange that occurs at Al–N double-dopant sites at graphene divacancies created by our plasma treatment.

36 MATERIALS SCIENCE↗

Artifact identification in X-ray diffraction data using machine learning methods

In situ synchrotron high-energy X-ray powder diffraction (XRD) is highly utilized by researchers to analyze the crystallographic structures of materials in functional devices ( e.g. battery materials) or in complex sample environments ( e.g. diamond anvil cells or syntheses reactors). An atomic structure of a material can be identified by its diffraction pattern along with a detailed analysis of the Rietveld refinement which yields rich information on the structure and the material, such as crystallite size, microstrain and defects. For in situ experiments, a series of XRD images is usually collected on the same sample under different conditions ( e.g. adiabatic conditions) yielding different states of matter, or is simply collected continuously as a function of time to track the change of a sample during a chemical or physical process. In situ experiments are usually performed with area detectors and collect images composed of diffraction patterns. For an ideal powder, the diffraction pattern should be a series of concentric Debye–Scherrer rings with evenly distributed intensities in each ring. For a realistic sample, one may observe different characteristics other than the typical ring pattern, such as textures or preferred orientations and single-crystal diffraction spots. Textures or preferred orientations usually have several parts of a ring that are more intense than the rest, whereas single-crystal diffraction spots are localized intense spots owing to diffraction of large crystals, typically >10 µm. In this work, an investigation of machine learning methods is presented for fast and reliable identification and separation of the single-crystal diffraction spots in XRD images. The exclusion of artifacts during an XRD image integration process allows a precise analysis of the powder diffraction rings of interest. When it is trained with small subsets of highly diverse datasets, the gradient boosting method can consistently produce high-accuracy results. The method dramatically decreases the amount of time spent identifying and separating single-crystal diffraction spots in comparison with the conventional method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

Exploring Cs 2 AgIn x Bi 1− x Cl 6 double perovskites for optoelectronics: insights from theoretical and photophysical approaches

Lead-free halide double perovskites (HDPs) have become attractive materials for optoelectronic applications owing to their nontoxicity, structural stability, and germane photoelectric properties. In this work, we report the synthesis of high-quality In-alloyed Cs 2 AgIn x Bi (1−x) Cl 6 nanocrystals (NCs) using the antisolvent recrystallization method and comprehensively investigate the effects of In alloying on the structural, morphological, optoelectronic, and temperature-dependent photoluminescence (TDPL) properties using the state-of-the-art experimental and computational tools. Both XRD and Raman spectroscopy analyses confirmed the synthesis of highly crystalline Cs 2 AgIn x Bi (1−x) Cl 6 materials, which exhibited cubic morphology, as confirmed by TEM analysis. Room-temperature photoluminescence (PL) measurements revealed a drastic increase in the intensity above 75% In concentration with dual emission, whereas the time-resolved PL (TR-PL) results show an increase in the average lifetime values with an increase in In content, suggesting that the materials have excellent optical properties and hence are suitable candidates for optoelectronics. The TDPL measurements revealed the smallest Huang–Rhys factor (18.6) for the Cs 2 AgIn x Bi (1−x) Cl 6 (x = 0.9) sample, indicating weak exciton–phonon coupling in this composition. When deployed in the fabrication of a photodetector device, the Cs 2 AgIn x Bi (1−x) Cl 6 (x = 0.9) sample exhibited significantly enhanced photoresponsivity and a faster response time, confirming its potential for photodetector applications. Complementary DFT calculations showed that In alloying modifies the band structure of Cs 2 AgIn x Bi (1−x) Cl 6 . Our results provide valuable insights for designing multifunctional Cs 2 AgIn x Bi (1−x) Cl 6 -based materials for next-generation energy and optoelectronic devices.

14 SOLAR ENERGY↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Deuterium supersaturated surface layer in tungsten: ion energy dependence

Abstract Properties of deuterium (D) supersaturated surface layers (DSSLs) formed in tungsten (W), such as thickness, internal microstructures, and D retention, are experimentally investigated as a function of the incident ion energy, E i . W samples were exposed to D plasmas in the PISCES-A linear plasma device in a range of E i ∼ 45–175 eV, while other plasma exposure parameters were fixed: sample temperature, T s , ∼423 K, ion flux, Γ i , ∼1.2 × 10 21 m −2 s −1 , and fluence, Φ i , ∼3.0 × 10 24 m −2 . High-resolution, cross-sectional, transmission electron microscopy observations confirm that (1) a DSSL forms even at the lowest E i ∼ 45 eV, (2) the DSSL thickness, Δ t DSSL , is found to decrease with decreasing E i from ∼11–12 nm at E i ∼ 175 eV to ∼5–6 nm at ∼45 eV, and to agree with approximately the maximum implantation depth calculated using SDTrimSP, and (3) high-density D nanobubbles with a diameter of ∼1 nm or less exist inside the DSSL, which is deemed to validate a theory-predicted vacancy stabilization process due to trapping of a solute D atom(s). Utilizing a D areal density of ∼4.2 × 10 19 m −2 in the first 14 nm from the surface at E i ∼ 75 eV from nuclear reaction analysis and the measured E i dependence of Δ t DSSL , our previous laser-induced breakdown spectroscopy data is updated: both dynamic and static D retention increase with decreasing E i , and the D/W atomic fraction during plasma exposure reaches ∼0.3 at E i ∼ 45 eV. A possible DSSL formation mechanism is proposed.

Physics↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

Problem-tailored Simulation of Energy Transport on Noisy Quantum Computers

The transport of conserved quantities like spin and charge is fundamental to characterizing the behavior of quantum many-body systems. Numerically simulating such dynamics is generically challenging, which motivates the consideration of quantum computing strategies. However, the relatively high gate errors and limited coherence times of today's quantum computers pose their own challenge, highlighting the need to be frugal with quantum resources. In this work we report simulations on quantum hardware of infinite-temperature energy transport in the mixed-field Ising chain, a paradigmatic many-body system that can exhibit a range of transport behaviors at intermediate times. We consider a chain with L = 12 sites and find results broadly consistent with those from ideal circuit simulators over 90 Trotter steps, containing up to 990 entangling gates. To obtain these results, we use two key problem-tailored insights. First, we identify a convenient basis – the Pauli Y basis – in which to sample the infinite-temperature trace and provide theoretical and numerical justifications for its efficiency relative to, e.g., the computational basis. Second, in addition to a variety of problem-agnostic error mitigation strategies, we employ a renormalization strategy that compensates for global nonconservation of energy due to device noise. We discuss the applicability of the proposed sampling approach beyond the mixed-field Ising chain and formulate a variational method to search for a sampling basis with small sample-to-sample fluctuations for an arbitrary Hamiltonian. This opens the door to applying these techniques in more general models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗