Search NASA⌕ Search

SEARCH · Search NASA

Results for “Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantitative analysis of cost savings and occupants’ preferences in grid-interactive smart home operation

Many utility companies in the United States have introduced time-of-use (TOU) rates for homeowners with the goal of regulating electricity consumption during peak hours. The electrical appliances in homes include various thermostatically controlled devices, such as air conditioners (AC) for thermal comfort, and nonthermostatically controlled devices such as clothes washers. As a result, homeowners face the complicated challenge of economically operating multiple electrical appliances in their homes while maintaining comfort and convenience. This is usually due to the lack of an explicit understanding of the correlation between cost saving and the users’ comfort. To understand the correlation, this article is designed to construct a framework by integrating three major components: a multi-objective optimization method accommodating multiple competing goals with different weights, a learning-based system modeling approach describing the dynamics and thermal coupling effects of appliances, and a novel comfort index method differentiating preferred and acceptable thermal comfort. Our proposed framework can allow the indoor air temperature to fall into the "preferred" range with a marginal cost increase. Furthermore, the simulation result shows that an additional 8 h for the preferred thermal comfort can be achieved with a cost increase of only 1.77%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗

Compensatory reserve detects subclinical shock with more expeditious prediction for need of life‐saving interventions compared to systolic blood pressure and blood lactate

Abstract Introduction We conducted a prospective observational study on 205 trauma patients at a level I trauma facility to test the hypothesis that a compensatory reserve measurement (CRM) would identify higher risk for progression to shock and/or need a life‐saving interventions (LSIs) earlier than systolic blood pressure (SBP) and blood lactate (LAC). Methods A composite outcome metric included blood transfusion, procedural LSI, and mortality. Discrete measures assessed as abnormal (ab) were SBP <90 mmHg, CRM <60%, and LAC >2.0. A graded categorization of shock was defined as: no shock (normal [n] SBP [n‐SBP], n‐CRM, n‐LAC); sub‐clinical shock (ab‐CRM, n‐SBP, n‐LAC); occult shock (n‐SBP, ab‐CRM, ab‐LAC); or overt shock (ab‐SBP, ab‐CRM, ab‐LAC). Results Three patients displayed overt shock, 53 displayed sub‐clinical shock, and 149 displayed no shock. After incorporating lactate into the analysis, 86 patients demonstrated no shock, 25 were classified as sub‐clinical shock, 91 were classified as occult shock, and 3 were characterized as overt shock. Each shock subcategory revealed a graded increase requiring LSI and transfusion. Initial CRM was associated with progression to shock (odds ratio = 0.97; p < .001) at an earlier time than SBP or LAC. Conclusions Initial CRM uncovers a clinically relevant subset of patients who are not detected by SBP and LAC. Our results suggest CRM could be used to more expeditiously identify injured patients likely to deteriorate to shock, with requirements for blood transfusion or procedural LSI.

Convertino, Victor A.↗

A Framework for Optimal Placement of Rooftop Photovoltaic: Maximizing Solar Production and Operational Cost Savings in Residential Communities

Optimizing the placement of photovoltaic (PV) panels on residential buildings has the potential to significantly increase energy efficiency benefits to both homeowners and communities. Strategic PV placement can lower electricity costs by reducing the electricity fed from the grid during on-peak hours, while maintaining PV panel efficiency in terms of the amount of solar radiation received. In this article, we present a framework that identifies the ideal location of PV panels on residential rooftops. Our framework combines energy and environmental simulation, parametric modeling, and optimization to inform PV placement as it relates to and affects the entire community (in terms of both energy use and financial cost), as well as individual buildings. Ensuring that our framework accounts for shading from nearby buildings, different utility rate structures, and different buildings’ energy demand profiles means that existing communities and future housing developments can be optimized for energy savings and PV efficiency. The framework comprises two workflows, each contributing to optimal PV placement with a unique target: (a) maximizing PV panel efficiency (i.e., solar generation) and (b) minimizing operational energy cost considering utility rate structures for operational energy. We apply our framework to a residential community in Fort Collins, Colorado, to demonstrate the optimal PV placement, considering the two workflow targets. Here, we present our results and illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost.

14 SOLAR ENERGY↗

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

Interregional Electricity Transmission in the United States: Realized Savings and Opportunities for Increased Value, 2014 to 2023

Interregional electricity trade in the United States reduces total energy costs, but falls short of maximizing the economic potential of existing transmission infrastructure. This analysis of thirty-two U.S. electricity system interfaces crossing grid or market seams finds an average achieved cost savings of at least $1,226 million per year. This positive impact is offset by an average annual cost of uneconomic interchange of $551 million. Additional value of at least $238 million per year could be enabled by increasing utilization. Notably, uneconomic flows and low utilization rates can persist even when the price spread between regions is large. These conclusions are derived from historical (2014–2023) data on the magnitude and direction of interregional price spreads, the magnitude and direction of net energy transfers, and how these variables coincide, but do not account for all system constraints. These findings motivate the development and deployment of solutions that improve interregional transmission operations, in parallel with robust transmission infrastructure planning. JEL Classification: Q40 Energy: General

Q40 Energy: General↗

BEPAM Model Code and CABBI Simulation Results for "Assessing the Additional Carbon Savings with Biofuel"

This dataset consists of various input data that are used in the GAMS model. All the data are in the format of .inc which can be read within GAMS or Notepad. Main data sources include: acreage data (acre), crop budget data ($/acre), crop yield data (e.g. bushel/acre), Soil carbon sequestration data (KgCO2/ha/yr). Model details can be found in the "Assessing the Additional Carbon Savings with Biofuel" and GAMS model package. ## File Description (1) GAMS Model.zip: This includes all the input files and scripts for running the model (2) Table*.csv: These files include the data from the tables in the manuscript (3) Figure2_3_4.csv: This contains the data used to create the figures in the manuscript (4) BaselineResults.csv: This includes a summary of the model results. (5) SensitivityResults_*.csv: Model results from the various sensitivity analyses performed (6) LUC_emission.csv: land use change emissions by crop reporting district for changes of pasturelands to annual crops.

Anticipated baseline approach↗

Code and Data for "Quantifying Uncertainties in Greenhouse Gas Savings and Mitigation Costs with Cellulosic Biofuels"

Use of cellulosic biofuels from non-feedstocks are modeled using the BEPAM (Biofuel and Environmental Policy Analysis Model) model to quantifying the uncertainties about induced land use change effects, net greenhouse gas saving potential, and economic costs. The code is in GAMS, general algebraic modeling language. NOTE: Column 3 is titled "BAU" in "merged_BAU.gdx", "merged_RFS.gdx", and "merged_CEM.gdx", but contains "RFS" data in "merged_RFS.gdx" and "CEM" data in "merged_CEM.gdx".

BEPAM↗

National Mandates Won’t Save Us!: How to Design Energy Efficiency Policies that Address Institutional Barriers to Change

There are many national policies aimed at driving an increase in energy efficiency (EE) implementation. But how effective are they? Over the past 20 years, the U.S. government has established five legal authorities mandating federal agencies to prioritize energy-efficient products when purchasing. As the largest single buyer of energy-consuming products, energy-efficient purchasing across the federal sector would result in huge energy savings and emissions reductions. Despite this, our research has found that only ~55% of federal purchases currently meet existing requirements. If national mandates are not enough to ensure that federal agencies are buying efficient products, what is? To answer this question, we surveyed 161 procurement and sustainability staff from 26 different federal agencies. Findings revealed that several institutional factors (i.e., the roles, rules, and tools within an organization) play a key role in determining how likely federal buyers are to prioritize EE. Ensuring that federal agencies comply with existing EE requirements is foundational to achieving a clean energy future. This will require more than national mandates, but also the design of policies that successfully identify and address the institutional factors that must be changed in order to increase EE implementation. This paper presents an overview of the data collection and analysis methods for our study, as well as key survey findings and the insights they offer for overcoming institutional barriers to compliance with existing EE requirements. We conclude by discussing how these strategies can be broadly applied to improve the design of EE policies in the U.S. and beyond.

Morabito, Molly↗

Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures, September 2011 - August 2020

This document has been updated in August 2020. This document was developed for the U.S. Department of Energy Uniform Methods Project (UMP). The UMP provides model protocols for determining energy and demand savings that result from specific energy-efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The protocols are updated on an as-needed basis. The UMP protocols can be used by utilities, program administrators, public utility commissions,evaluators, and other stakeholders for both program planning and evaluation. To learn more about the UMP, visit the website, https://energy.gov/eere/about-us/ump-home, or download the UMP introduction document at http://www.nrel.gov/docs/fy17osti/68557.pdf.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Saving Energy: A QuickStart Guide for Small/Medium Manufacturers

The Quick Start Guide aims to serve as an introduction to energy efficiency for small to medium manufacturers, explaining why energy management is important and achievable for all organizations, not just well-resourced, energy-intensive large organizations. It also makes connections to the tools and resources available from DOE to help small to medium manufacturers drive energy savings and sustain the progress. Finally, it provides a list of common energy efficiency opportunities for energy consuming systems such as steam, process heating, and motor-driven systems. Explore the guide to see how smaller manufacturing companies can get started with energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures (September 2011 - August 2020)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attack Scenarios Relating to Army Facility-Related Control Systems: Quantifying the Cost to Secure and Cost Savings of the Army’s FRCS Program

Pacific Northwest National Laboratory (PNNL) analyzed the cyber-threat environment to U.S. Army facilities. This report describes three key factors in securing Army-owned facility-related control systems (FRCS). First, Section 1.0 provides background information about the project. Section 2.0 describes the various types of cyber-attacks. Section 3.0 provides a series of attack scenarios from real-world use cases are described in Section 3. These examples are relevant to the Army because the targeted systems or operating environments are like those used at Army installations. An estimated range for the cost to secure these systems is described in Section 4.0. Finally, the cost savings of preventing these kinds of attacks are described in Section 5.0.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Achieving Energy Savings in Small- and Medium-Sized Public Facilities: A Strategic Approach to Prioritizing and Financing

This resource is for state, local government, and K-12 school staff managing small- and medium-sized facilities. Readers will learn to address the unique challenges of smaller energy-saving projects and make informed decisions about financing. Section 1 provides tools for obtaining the information required to prioritize potential energy upgrades. Section 2 presents financing options for energy upgrades, as well as insights that will help decision makers select the right financing model for their project and jurisdiction. Section 3 summarizes key takeaways and highlights additional resources for small- and medium-sized public facilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NTESS Savings and Income Plan, Summary Plan Description

National Technology & Engineering Solutions of Sandia, LLC (NTESS) has recently amended the NTESS Savings and Income (401(k) Plan). The updated Summary Plan Description (SPD) for the 401(k) Plan effective January 1, 2022 is provided.

99 GENERAL AND MISCELLANEOUS↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗