Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Exploring possible ferromagnetism of the LaAl O 3 / SrTi O 3 interface

We report on extensive investigations of magnetism at the n -type LaAl O 3 / SrTi O 3 interface performed by utilizing a spectrum of local and integrative analytical techniques: Scanning superconducting quantum interference device microscopy, polar Kerr magnetometry, ferromagnetic resonance, and magnetic torque magnetometry. The samples originated from the same wafers. For nominally fully oxidized samples, we find that the mere presence of the conducting interface does not induce magnetism to values exceeding already present magnetic signals originating from the substrates, irrespective of the measurement technique. With the controlled introduction of oxygen vacancies, however, the different analytical techniques with their inherently different sensitivities and potential interactions with possible magnetic moments in the samples yield different results concerning the existence of magnetism. These unexpected differences obtained with the various measurement techniques are a possible source of the disagreement in the literature about the existence of ferromagnetism at LaAl O 3 / SrTi O 3 interfaces.

36 MATERIALS SCIENCE↗

Search for the ν{sub μ} → ν{sub τ} oscillation with the OPERA hybrid detector

This work reviews the status of the international OPERA experiment aimed at searching for the ν{sub μ} → ν{sub τ} oscillation. Development of the emulsion techniques in the preceding DONUT and CHORUS experiments is described. A brief overview of the NOMAD experiment is given, in which properties of ν{sub τ} interactions were thoroughly investigated. Characteristics of the CERN-Gran Sasso (CNGS) neutrino beam are given, the structure of the OPERA hybrid detector and the functions of its subsystems are considered, and the automatic emulsion scanning technique is briefly reviewed. Uncertainties in reconstruction of event parameters using the electronic and emulsion detectors are discussed and the procedure adopted in the experiment for identification of ν{sub τ} interactions is described. The main sources of background in the search for ν{sub μ} → ν{sub τ} oscillation are considered. Topologies of the first two ν{sub τ} candidates observed in the OPERA emulsion detector are presented. Possibilities of increasing the ν{sub τ} interaction selection efficiency using multidimensional criteria are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Relating Quantitative Soil Structure Metrics to Saturated Hydraulic Conductivity

Core Ideas Soil structure quantified in the field using a 3D laser scanning technique (MLT). MLT data and coefficient of linear extensibility combined into a structure metric. Soil water contents recorded at four depths in a field lysimeter and used in HYDRUS‐1D. Saturated conductivity ( K s ) estimated with a Markov chain Monte Carlo approach. New metric better correlated to K s in horizons with strong soil structure. Soil structure affects saturated hydraulic conductivity ( K s ) by creating highly conductive macropores that preferentially transmit soil water. In this study, we explored the relationship between K s and macropores in an Oxyaquic Vertic Argiudoll in northeastern Kansas. Macropores were quantified from an excavation wall using multistripe laser triangulation (MLT) scanning. Soil water contents were measured at four depths within a soil lysimeter installed within 2 m of the MLT‐scanned soil profile and adjacent to an Ameriflux tower monitoring precipitation, air temperature, and solar radiation. Selected hydraulic properties of soil horizons within the lysimeter were optimized to water content data using a Markov chain Monte Carlo technique in combination with the mobile–immobile water (MIM) model in HYDRUS‐1D. Estimates of K s varied between 4198 cm d −1 in the A horizon and 0.6 cm d −1 in a 2Btss2 horizon with strongly expressed wedge structure. Approximately 87% of the variation in K s was explained by the geometric mean of the widths of pores quantified with the MLT technique and modified by the coefficient of linear extensibility (COLE). The use of the COLE allows the widths of the macropores obtained under dry conditions to be approximated at saturation. Two models that predict K s from either texture or water retention data resulted in K s estimates that were similar to each other but significantly lower than K s values predicted with MIM in horizons where structural pores dominate water flow. This technique shows a great deal of promise in better understanding and predicting the relationship of soil structure to water flow.

Eck, Dennis V.↗

Photosensor aperture shaping to reduce aliasing in optical-mechanical line-scan imaging systems.

Review of optical-mechanical scanning techniques that are generally employed in instruments specifically designed to characterize variations in scene brightness spectrally or radiometrically. Special attention is given to the effect of aliasing on the spatial detail of the reconstructed image. Aliasing may be caused by linescan sampling and can, in turn, severely degrade images that emphasize the spatial characterization of a scene. Photosensor aperture shaping and line-scan spacing are investigated as means for reducing this degradation.

Katzberg, S. J.↗

Holographic interferometry at the NASA-Ames Hypervelocity Free-Flight Aerodynamic Facility

A laser holographic interferometer has been designed and developed to improve flow visualization for models in free-flight at high velocities and low freestream static pressures. Of special interest is the flow structure due to high-temperature effects in the post-shock region of models traveling at hypervelocity. A dual-plate technique with a double-pass, Michelson-type configuration has been incorporated in an existing hypervelocity ballistic range. Holograms of 5-deg blunt conical models traveling at 5 km/sec in air at a freestream static pressure of 0.08 atm have been made. Finite- and infinite-fringe interferograms were reconstructed from the holograms and provided qualitative flowfield results. In addition, a digital scanning technique was also used to produce a 'synthetic' infinite-fringe interferogram from the analysis of an experimental finite-fringe interferogram. A 'synthetic' infinite-fringe interferogram shows detail in the wake region not found in the experimental interferograms.

Tam, Tim C.↗

Screening of metal matrix composites using ultrasonic C-scans

Ultrasonic C-scans can be used to find some types of defects in continuous fiber-reinforced metal matrix composites such as boron/aluminum composites. These defects are related to the fatigue behavior and fracture location of each inspected specimen. The C-scan technique determined the relative amount of defects in boron/aluminum composites. The defects were primarily identified as gaps in the fiber spacing. Those specimens with higher defect densities had shorter fatigue lives, lower fatigue endurance limits, and greater reductions in the elastic unloading modulus (that is, stiffness) because of fatigue cycling. This type of data could be used to set accept/reject levels for a composite panel based on C-scan indications.

Johnson, W. S.↗

Enhanced resonant nonlinear absorption and optical limiting in Er3+ ions doped multicomponent tellurite glasses

Highlights: • Nonlinear optical properties of TPBKZFEr glasses investigated by Z-scan technique. • Optical limiting property of the TPBKZFEr glasses is studied for the first time. • Nonlinearity of the prepared glasses found to be enhanced with Er{sup 3+} concentration. • The mechanism behind the nonlinear properties is successfully explained. • It is evident that these glasses can be developed as tunable optical limiters. - Abstract: Nonlinear optical properties of multicomponent tellurite glasses doped with Er{sup 3+} ions were investigated by open aperture Z-scan measurements. Compositional and linear optical properties of the glasses were examined by the energy dispersive X-ray spectrum and UV–vis–NIR absorption spectrum analysis respectively. The mechanism behind the optical nonlinearity and optical limiting efficiency was successfully explained by evaluating the physical properties such as density, refractive index and polarizability of the glasses. The nonlinear properties critically depend on the polarizability, which is found to increase with the addition of Er{sup 3+} ions by the creation of non-bridging oxygen ions. By the systematic addition of Er{sup 3+} ions, we have dictated the physical properties and thus tuned the optical limiting efficiency of the glasses. This makes the Er{sup 3+}-doped multicomponent tellurite glasses flexible tunable optical limiters for potential device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrochemical Imaging of Interfaces in Energy Storage via Scanning Probe Methods: Techniques, Applications, and Prospects

Developing a deeper understanding of dynamic chemical, electronic, and morphological changes at interfaces is key to solving practical issues in electrochemical energy storage systems (EESSs). To unravel this complexity, an assortment of tools with distinct capabilities and spatiotemporal resolutions have been used to creatively visualize interfacial processes as they occur. This review highlights how electrochemical scanning probe techniques (ESPTs) such as electrochemical atomic force microscopy, scanning electrochemical microscopy, scanning ion conductance microscopy, and scanning electrochemical cell microscopy are uniquely positioned to address these challenges in EESSs. We describe the operating principles of ESPTs, focusing on the inspection of interfacial structure and chemical processes involved in Li-ion batteries and beyond. We discuss current examples, performance limitations, and complementary ESPTs. Finally, we discuss prospects for imaging improvements and deep learning for automation. We foresee that ESPTs will play an enabling role in advancing EESSs as we transition to renewable energies.

25 ENERGY STORAGE↗

Z-Scan Measurement of the Nonlinear Absorption of a Thin Gold Film

We have used the z-scan technique at a wavelength (532 nm) near the transmission window of bulk gold to measure the nonlinear absorption coefficient of continuous approximately 50-Angstrom-thick gold films, deposited onto surface-modified quartz substrates. For highly absorbing media such as metals, we demonstrate that determination of either the real or imaginary part of the third-order susceptibility requires a measurement of both nonlinear absorption and nonlinear refraction, i.e. both open- and closed-aperture z-scans must be performed. Closed-aperture z-scans did not yield a sufficient signal for the determination of the nonlinear refraction. However, open-aperture z-scans yielded values ranging from Beta = 1.9 x 10(exp -3) to 5.3 x 10(exp -3) cm/W in good agreement with predictions which ascribe the nonlinear response to a Fermi smearing mechanism. We note that the sign of the nonlinearity is reversed from that of gold nanoparticle composites, in accordance with the predictions of mean field theories.

Smith, David D.↗

Statistical coverage for supersymmetric parameter estimation: a case study with direct detection of dark matter

Models of weak-scale supersymmetry offer viable dark matter (DM) candidates. Their parameter spaces are however rather large and complex, such that pinning down the actual parameter values from experimental data can depend strongly on the employed statistical framework and scanning algorithm. In frequentist parameter estimation, a central requirement for properly constructed confidence intervals is that they cover true parameter values, preferably at exactly the stated confidence level when experiments are repeated infinitely many times. Since most widely-used scanning techniques are optimised for Bayesian statistics, one needs to assess their abilities in providing correct confidence intervals in terms of the statistical coverage. Here we investigate this for the Constrained Minimal Supersymmetric Standard Model (CMSSM) when only constrained by data from direct searches for dark matter. We construct confidence intervals from one-dimensional profile likelihoods and study the coverage by generating several pseudo-experiments for a few benchmark sets of pseudo-true parameters. We use nested sampling to scan the parameter space and evaluate the coverage for the benchmarks when either flat or logarithmic priors are imposed on gaugino and scalar mass parameters. The sampling algorithm has been used in the configuration usually adopted for exploration of the Bayesian posterior. We observe both under- and over-coverage, which in some cases vary quite dramatically when benchmarks or priors are modified. We show how most of the variation can be explained as the impact of explicit priors as well as sampling effects, where the latter are indirectly imposed by physicality conditions. For comparison, we also evaluate the coverage for Bayesian credible intervals, and observe significant under-coverage in those cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Biomaterials Using Micro-Computerized Tomography

Micro-computed tomography or Micro-CT is a high resolution, non-invasive, x-ray scanning technique that allows precise three-dimensional imaging and quantification of micro-architectural and structural parameters of objects. Tomographic reconstruction is based on a cone-beam convolution-back-projection algorithm. Micro-architectural and structural parameters such as porosity, surface area to volume ratio, interconnectivity, pore size, wall thickness, anisotropy and cross-section area of biomaterials and bio-specimens such as trabecular bone, polymer scaffold, bio-ceramics and dental restorative were evaluated through imaging and computer aided manipulation of the object scan data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frisker Response to Soil Concentrations (Bq/g) Compared to NaI(Tl) - 19338

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Portions of the site land areas have become radiologically contaminated through the 1952 National Reactor Experimental (NRX) accident and/or waste management activities over the past 70 years of site operations. The Environmental Remediation Projects Group (ERP) characterizes, and performs risk assessment, and remedial actions, as required over these contaminated land areas. ERP work activities are subject to controls established by CRL's Radiation Protection (RP) Group such that RP establishes the radiological controls and monitoring requirements for ERP field work activities. The different methods of monitoring soil contamination between ERP and the RP program present some challenges in the interpretation and comparison of the two sets of results and the soil disposition. ERP utilizes NaI(Tl) scintillation detectors and MARSSIM land scanning techniques to measure soil concentrations between sample locations and in excavated materials. Whereas, RP utilizes surface contamination monitoring equipment in the form of a 15.5 cm{sup 2} open area pancake Geiger-Mueller (GM) tube detector to measure soil contamination levels reported in counts per minute (cpm). This paper presents a method to evaluate the theoretical best responses that could be obtained from surface contamination monitoring instrumentation for a known concentration (1 Bq/g) of various radionuclides. A static efficiency of cpm/Bq{sup -1} g{sup -1} is obtained from these calculations. These contamination monitoring sensitivities are then used in a MARSSIM scanning sensitivity equation and compared to the scanning sensitivity of an NaI(Tl) scintillation detector. The results demonstrate that the sensitivity of the frisker probes to particle radiations (betas for pancake) tend to fall in a range of only a few cpm/Bq{sup -1} g{sup -1}. Rather, the primary static response of the pancake probe to soil contamination is from gamma radiation where a value of 36 cpm/Bq{sup -1} g{sup -1} for Cs-137 was obtained at 2.54 cm distance without the application of scanning statistics. In comparison, a 7.6 cm x 7.6 cm NaI(Tl) detector has a Cs-137 static response factor of 10,000 cpm/Bq{sup -1} g{sup -1} at 15 cm distance without applying scanning statistics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-Molecule Interfacial Electron Transfer

This project is focused on the use of single-molecule high spatial and temporal resolved techniques to study molecular dynamics in condensed phase and at interfaces, especially, the complex reaction dynamics associated with electron and energy transfer rate processes. The complexity and inhomogeneity of the interfacial ET dynamics often present a major challenge for a molecular level comprehension of the intrinsically complex systems, which calls for both higher spatial and temporal resolutions at ultimate single-molecule and single-particle sensitivities. Combined single-molecule spectroscopy and electrochemical atomic force microscopy approaches are unique for heterogeneous and complex interfacial electron transfer systems because the static and dynamic inhomogeneities can be identified and characterized by studying one molecule at a specific nanoscale surface site at a time. The goal of our project is to integrate and apply these spectroscopic imaging and topographic scanning techniques to measure the energy flow and electron flow between molecules and substrate surfaces as a function of surface site geometry and molecular structure. We have been primarily focusing on studying interfacial electron transfer under ambient condition and electrolyte solution involving both single crystal and colloidal TiO 2 and related substrates. The resulting molecular level understanding of the fundamental interfacial electron transfer processes will be important for developing efficient light harvesting systems and broadly applicable to problems in fundamental chemistry and physics. We have made significant advancement on deciphering the underlying mechanism of the complex and inhomogeneous interfacial electron transfer dynamics in dyesensitized TiO 2 nanoparticle systems that strongly involves with and regulated by molecule-surface interactions. We have studied interfacial electron transfer on TiO 2 nanoparticle surfaces by using ultrafast single-molecule spectroscopy and electrochemical AFM metal tip scanning microscopy, focusing on understanding the interfacial electron transfer dynamics at specific nanoscale electron transfer sites with high-spatially and temporally resolved topographic-and-spectroscopic characterization at individual molecule basis, characterizing single-molecule rate processes, reaction driving force, and molecule-substrate electronic coupling. One of the most significant characteristics of our new approach is that we are able to interrogate the complex interfacial electron transfer dynamics by actively pin-point energetic manipulation of the surface interaction and electronic couplings, beyond the conventional excitation and observation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The electron microprobe as a metallographic tool

The electron microprobe (EMP) is shown to represent one of the most powerful techniques for the examination of the microstructure of materials. It is an electron optical instrument in which compositional and topographic information is obtained from regions smaller than 1 micron in diameter on a specimen. Photographs of compositional and topographic changes in 1-sq-mm to 20-sq-micron areas on various types of specimens can also be obtained. These photographs are strikingly similar to optical photomicrographs. Various signals measured in the EMP (X-rays, secondary electrons, backscattered electrons, etc.) are discussed, along with their resolution and the type of information they may help obtain. In addition to elemental analysis, solid state detecting and scanning techniques are reviewed. Various techniques extending the EMP instrument capabilities, such as deconvolution and soft X-ray analysis, are also described.

Goldstein, J. I.↗

Atomic Scale Crystal Field Mapping of Polar Vortices in Oxide Superlattices

Polar vortices in oxide superlattices can be utilized as potential candidates for data storage applications due to their unique polarization topologies. The structure and dipole arrangement in polar vortices has been studied via X-ray scattering techniques, (scanning) transmission electron microscopy ((S)/TEM) and computational calculations. However, the fundamental correlation between the atomic structure and the electronic structure (which is manifested in the chemical bonding) has heretofore not been explored. Further, The hybridization between nominally empty $\textit{d}$ orbitals on the B-site with the occupied O 2$\textit{p}$ orbitals favors the condensation of a polar (ferroelectric) state in $\textit{AB}$O 3 perovskite oxides. The complex, continuously rotating local polarization texture of the vortices, in turn, can result in especially intricate $\textit{d}$- orbital interactions. Soft X-ray spectroscopy can probe these interactions at the transition metal $\textit{L}$-edge, but these techniques do not have the spatial resolution to resolve variations within one vortex (~5 nm region). Electron energy loss spectroscopy (EELS) in the STEM mode uses inelastically scattered electrons to probe the core-shell excitations (empty density of states) of transition metals at atomic resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗

The CNAO dose delivery system for modulated scanning ion beam radiotherapy

Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.

60 APPLIED LIFE SCIENCES↗

TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax.

42 ENGINEERING↗

Nonlinear refraction properties of nickel oxide thin films at 800 nm

Measurements of the nonlinear refractive index, n{sub 2}, of nickel oxide films prepared by controlled oxidation of nickel films deposited on substrates of soda-lime glass are reported. The structure and morphology of the samples were characterized by scanning electron microscopy, atomic force microscopy, and x-ray diffractometry. Samples of excellent optical quality were prepared. The nonlinear measurements were performed using the thermally managed eclipse Z-scan technique at 800 nm. A large value of n{sub 2}approx =10{sup -12} cm{sup 2}/W and negligible nonlinear absorption were obtained.

36 MATERIALS SCIENCE↗