Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Study of the time-differentiated particle flux density at various distances from EAS axis

The EAS time structure is studied using the enlarged EAS array of the Moscow State University. The time measurements are made using 22 scintillators which form 13 rectanges of 180x190 sq m size covering the entire array area. The array is triggered by a signal of 4-fold coincidences of the pulses from the detectors forming each of the rectangles. The data were obtained during 2200 hours of the array operation in 1984. A total of 816 showers, to which at least 14 of 22 scintillator detectors responded, were selected among all those detected. The coordinates of the EAS axis in the observation plane and the EAS sizes were determined by the maximum likelihood method using a computer on the assumption that the electron LDF is the NKG form. A total of 492 showers in the interval of EAS size Ne = 5x10 to the 6th power - 2x10 to the 8th power (N bar e = 1.7x 10 to the 7th power) with zenith angles theta or = 45 deg and axes within the array are analyzed.

Atrashkevich, V. G.↗

High resolution spectroscopy from low altitude satellites

The P 78 1 satellite to be placed in a synchronous polar orbit at an altitude of 550-660 km will carry two identical high resolution spectrometers each consisting of a single (approximately 85 cc) intrinsic germanium IGE detector. The payload also includes a pair of phoswitch scintillators, an array of CdTe detectors and several particle detectors, all of which are mounted on the wheel of the satellite. The intrinsic high purity IGE detectors receive cooling from two Stirling cycle refrigerators and facilitate the assembly of large and complex detector arrays planned for the next generation of high sensitivity instruments such as those planned for the gamma ray observatory. The major subsystems of the spectrometer are discussed as well as its capabilities.

Nakano, G. H.↗

Spectroscopy in X-ray astronomy

Detailed features in cosmic X-ray sources and their associated temporal variation over a wide energy range were studied. Excess emission and absorption at approximately 6 to 7 kiloelectron volts in the spectra of supernova remnants, binary X-ray sources, and clusters of galaxies were observed. A gas scintillation proportional counter (GSPC) will be used as the detector system. In the gas scintillator the principal limitation is due to the statistics of the initial ionization process only.

Andresen, R.↗

Hard X-ray and low-energy gamma-ray spectrometers

Basic principles of operation and characteristics of scintillation and semi-conductor detectors used for solar hard X-ray and gamma-ray spectrometers are presented. Scintillation materials such as NaI offer high stopping power for incident gamma rays, modest energy resolution, and relatively simple operation. They are, to date, the most often used detector in solar gamma-ray spectroscopy. The scintillator BGO has higher stopping power than NaI, but poorer energy resolution. The primary advantage of semi-conductor materials such as Ge is their high-energy resolution. Monte-Carlo simulations of the response of NaI and Ge detectors to model solar flare inputs show the benefit of high resoluton for studying spectral lines. No semi-conductor material besides Ge is currently available with adequate combined size and purity to make general-use hard X-ray and gamma-ray detectors for solar studies.

Gehrels, N.↗

Character of energy flow in air shower core

Energy per charged particle near the core of air showers was measured by 9 energy flow detectors, which were the combination of Cerenkov counters and scintillators. Energy per particle of each detector was normalized to energy at 2m from the core. The following results were obtained as to the energy flow: (1) integral frequency distribution of mean energy per particle (averaged over 9 detectors) is composed of two groups separated distinctly; and (2) showers contained in one group show an anisotropy of arrival direction.

Mizushima, K.↗

Time Variations of Cosmic-Ray Helium Isotopes with BESS-Polar I

The Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is configured with a solenoidal superconducting magnet and a suite of precision particle detectors, including time-of-flight hodoscopes based on plastic scintillators, a silica-aerogel Cherenkov detector, and a high resolution tracking system with a central jet-type drift chamber. The charges of incident particles are determined from energy losses in the scintillators. Their magnetic rigidities (momentum/charge) are measured by reconstructing each particle trajectory in the magnetic field, and their velocities are obtained by using the time-of-flight system. Together, these measurements can accurately identify helium isotopes among the incoming cosmic-ray helium nuclei up to energies in the GeV per nucleon region. The BESS-Polar I instrument flew for 8.5 days over Antarctica from December 13th to December 21st, 2004. Its long-duration flight and large geometric acceptance allow the time variations of isotopic fluxes to be studied for the first time. The time variations of helium isotope fluxes are presented here for rigidities from 1.2 to 2.5 GV and results are compared to previously reported proton data and neutron monitor data.

Cosmic-ray flux time variations↗

Signal Conditioning for Satellite Borne Energetic-Charged-Particle Experiments

Many of the spacecraft launched thus far have carried detectors for investigating cosmic rays, solar protons, solar plasmas, and the geomagnetically trapped radiation. These detectors, which will find continued application in the future, include ion chambers; proportional, Geiger-Muller, scintillation, Cerenkov, and solid state detectors; ion collectors; and nuclear emulsions. The instrumentation required to condition the signals from these detectors prior to telemetering is steadily growing more complex in order to permit more meaningful measurements. This report describes a number of instrumentation elements typical of the present state of the art, and a present-generation three-detector system which illustrates the integration of such basic elements into a complex system.

Ludwig, George H.↗

A versatile pulse amplifier

Versatile pulse amplifier for use with scintillation counters, surface barrier detectors, proportional counters or channel electron multipliers

Lampton, M.↗

Spectra and angular distributions of atmospheric gamma rays from 0.3 to 10 MeV at lambda = 40 deg

Measurements of the spectral and angular distributions of atmospheric gamma sq cm rays in the energy range 0.3-10 MeV over Palestine, Texas, at residual depths of 2.5 and 70 g/sq cm are reported. In confirmation of the general features of a model prediction, the measurements show at 2.5 g/sq cm upward moving fluxes greater than the downward moving fluxes, the effect increasing with energy, and approximate isotropy at 70 g/sq cm. Numerous characteristic gamma-ray lines were observed, most prominently at 0.511, 1.6, 2.3, 4.4, and 6.1 MeV. Their intensities were also compared with model predictions. Observations were made with an actively shielded scintillator counter with two detectors, one of aperture 50 deg FWHM and the other of 120 deg FWHM. Above 1 MeV, contributions to the counting rate from photons penetrating the shield annulus and from neutron interactions were large; they were studied by means of a Monte Carlo code and are extensively discussed.

Ling, J. C.↗

Joint ROSAT-Compton GRO observations of the X-ray bright Seyfert galaxy IC 4329A

We report a simultaneous ROSAT and Gamma Ray Observatory (GRO) observation of the X-ray-bright Seyfert galaxy IC 4329A. For the GRO Oriented Scintillation Spectrometer Experiment (OSSE) detector, we also present the sum of the data for this and earlier observations. The overall spectrum is very well described as a power law with an energy spectral index of approximately 1 absorbed at low energies plus a strong Compton reflection component, typical for Seyfert 1 galaxies. The low energy absorption can be well described by a sum of a neutral column density of approximately 3 x 10(exp 21)sq cm, most of which is associated with the edge-on galactic disk of IC 4329A, plus an edgelike feature at approximately 700 eV; this feature implies either complex absorption (due to additional ionized material, or due to a partial covering), or a soft excess. The data only weakly constrain the presence of a high-energy cutoff in the underlying power law; they are compatible with an exponential cutoff at any energy E(sub c) approximately greater than 100 keV. The relative steepness of the OSSE data, with the power-law energy index of 1.6 +/- 0.2, can be accounted for entirely by the contribution of the high-energy tail of the reflection component when E(sub c) approaches infinity. (We find that the definite cutoff at an energy E(sub c)approximately 130 keV suggested in the recently published analysis of the OSSE data for this subject is due to a data reduction error.) Including nonsimultaneous Ginga observations with 2 keV fluxes matching well that of ROSAT gives us likely broad-band X-ray/gamma-ray spectra of the object from approximately 0.1 keV up to several hundred keV. We also report the ROSAT spectrum of the companion object to the Seyfert galaxy, the elliptical galaxy IC 4329.

Madejski, G. M.↗

Assay of the Martian Regolith with Neutrons

Different aspects of assaying Martian regolith using neutrons have been investigated. The epithermal portion of moderated neutrons spectra is dramatically effected by the presence of hydrogen (usually in the form of water). A simple analytic formula has been derived to describe the amplitude of this portion of the neutron spectrum as a function of water concentration. Several demonstration experiments have been performed and modeled with a Monte Carlo code. Results of these experiments generally agreed with the calculations to within 20%. In addition to He-3 detectors, lithium-glass scintillators and U-238 fission ion chambers were investigated to determine their applicability to space experiments.

Drake, Darrell M.↗

The HERO Program: High-Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy replicated optics for a balloon-borne hard-x-ray telescope. When completed, the telescope will have around 150 square cm of effective collecting area up to 65 keV, and an angular resolution of around 30 arc seconds, half power diameter. When used in conjunction with an array of focal plane imaging detectors, for which Gas Scintillation Proportional Counters are under development, the payload will provide unprecedented sensitivity for pointed observations in the hard-x-ray band. We will present an overview of the High Energy Replicated Optics (HERO) program together with test data from the first mirror units. The overall sensitivity of the full payload, when flown on long- and ultra-long-duration balloon flights, will be compared with past and planned satellite-borne hard-x-ray missions.

Ramsey, B. D.↗

Comparison of Measured and Simulated Albedo Signals in the ATIC Experiment

Albedo, radiation backscattered from an interaction and from the subsequent shower development, provides a 'background' for calorimeter experiments. In ATIC (Advanced Thin Ionization Calorimeter), a balloon borne instrument to measure cosmic ray composition and energy spectra for elements from hydrogen to iron from 30 GeV to near 100 TeV, a fully active BGO calorimeter follows a carbon interaction target and scintillator holdoscopes. The first detector is a silicon matrix constructed of 4480 individual silicon pixels, each 2 cm x 1.5 cm, that provide a measurement of the charge of the primary particle in the presence of albedo. ATIC had two successful balloon flights in Antarctica: from 28 Dec 2000 to 13 Jan 2001 (ATIC-1) and from 29 Dec 2002 to 18 Jan 2003 (ATIC-2). A comparison of albedo signals in the silicon matri:x in ATIC-1 experiment with simulations performed using the GEANT 3.21 code and the QGSM event generator for nucleus-nucleus interactions is presented.

Zatsepin, V. I.↗

Airborne Lightning Observatory for FEGS and TGFs (ALOFT)

The ALOFT campaign is a unique suborbital campaign to advance the science of highenergy radiation emissions from thunderstorms, validate existing spaceborne lightning mappers and evaluate design concepts for next-generation mappers, and study convection from a suborbital platform. ALOFT is a collaboration between NASA, the University of Bergen, and other institutions that will fly the ER-2 aircraft over tropical thunderstorms around the Gulf of Mexico, Central America, and the Caribbean. The payload will consist of lightning detectors, gamma-ray scintillators, and a mixture of passive and/or active microwave sensors. Supporting the flights will be a diverse groundbased network of lightning instruments spread across the region of interest.

Nikolai Ostgaard↗