Search NASA⌕ Search

SEARCH · Search NASA

Results for “Screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ocular screening tests of elementary school children

This report presents an analysis of 507 abnormal retinal reflex images taken of Huntsville kindergarten and first grade students. The retinal reflex images were obtained by using an MSFC-developed Generated Retinal Reflex Image System (GRRIS) photorefractor. The system uses a 35 mm camera with a telephoto lens with an electronic flash attachment. Slide images of the eyes were examined for abnormalities. Of a total of 1835 students screened for ocular abnormalities, 507 were found to have abnormal retinal reflexes. The types of ocular abnormalities detected were hyperopia, myopia, astigmatism, esotropia, exotropia, strabismus, and lens obstuctions. The report shows that the use of the photorefractor screening system is an effective low-cost means of screening school children for abnormalities.

Richardson, J.↗

Development of standardized specifications for screening space level integrated circuits and semiconductors

Standardized methods are established for screening of JAN B microcircuits and JANTXV semiconductor components for space mission or other critical applications when JAN S devices are not available. General specifications are provided which outline the DPA (destructive physical analysis), environmental, electrical, and data requirements for screening of various component technologies. This standard was developed for Air Force Space Division, and is available for use by other DOD agencies, NASA, and space systems contractors for establishing common screening methods for electronic components.

Source record↗

Gas flow across a wet screen - Analogy to a relief valve with hysteresis

The flow of gas through a wet fine-mesh screen is analyzed in terms of the capillary forces of the liquid wetting the screen and the pressure difference across the screen thickness driving the gas flow. Several different types of time-dependent flow are shown to be possible. The most interesting type is one in which the pressure difference opens small channels in the liquid, which are then closed rapidly by the wetting action of the liquid. The opening and closing exhibit hysteresis, and the flow is highly oscillatory.

Nachman, A.↗

Test and evaluation of the 2.4-micron photorefractor ocular screening system

An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

Richardson, J. R.↗

Vapor-screen flow-visualization experiments in the NASA Langley 0.3-m transonic cryogenic tunnel

The vortical flow on the leeward side of a delta-wing model has been visualized at several different tunnel conditions in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel using a vapor-screen flow-visualization technique. Vapor-screen photographs of the subject flow field are presented and interpreted relative to phenomenological implications. Results indicate that the use of nitrogen fog in conjunction with the vapor-screen technique is feasibile.

Selby, G. V.↗

Anharmonic and screening corrections to the melting of a two-dimensional charged colloidal crystal

The Kosterlitz-Thouless-Halperin-Nelson-Young theory of melting is applied to a two-dimensional charged colloidal crystal. The renormalization of elastic constants due to anharmonic and dislocation pair-screening effects is calculated. For colloidal spheres ('polyballs') suspended in a thin film of water confined between two glass plates whose surfaces are highly charged, as in recent experimental configurations, the corrections to the harmonic results simply require an altered effective polyball charge to reproduce virtually the identical melting curve of the harmonic approximation (which agrees well with experiment). The effect on the melting curve of added salt is also calculated; the corresponding experiments have yet to be performed. For a film between uncharged surfaces the anharmonic correction again softens the lattice significantly. Dislocation pair screening causes an additional but minor reduction of the elastic constants. Neither correction eliminates a nonmelting behavior characteristic of the two-dimensional screened Coulomb system in this configuration.

Chang, Enson↗

Cloud-screening for Africa using a geographically and seasonally variable infrared threshold

A spatially variable monthly, infrared cloud-threshold data base has been used to screen cloud-contaminated observations from radiances measured by the NOAA-9 AVHRR over Africa. Cloud-screening through a monthly average infrared threshold based on measured surface air temperature, which is geographically dependent, shows an improvement over using a seasonally and geographically independent thermal cloud threshold of 287 K. It is found that differences in cloud-screening for these two thresholds occur for cases of lower altitude clouds or subpixel clouds where the radiative temperature is higher than the 287 K infrared threshold, yet colder than the variable threshold developed by Stowe et al. (1988) for the Nimbus-7 global cloud climatology. The variable IR threshold is shown to be effective over persistently cloud-covered regions, such as the coastal region of the Gulf of Guinea, but may introduce some erroneous cloud identifications over mountains.

Eck, T. F.↗

Vaporization heat transfer of dielectric liquids on enhanced surfaces covered with screen wicks

Experiments were conducted to investigate the vaporization heat transfer characteristics for the dielectric liquid FC-72 on several wicking surfaces which may be used in flat-plate heat pipes. The wicking materials studied included microstructure enhanced surfaces and coarse surfaces covered with screen meshes. Experimental data for q versus deltaT curves and critical heat fluxes were obtained for the two different operating conditions of a heat pipe, evaporation, and shallow pool boiling. When the liquid level was above the heated surface, the height of the liquid level above the surface was varied from 0 to 10 mm. When the liquid level was below the heated surface, the distance from the liquid level to the edge of the surface was adjusted from 0 to 15 mm. Experimental results revealed that for shallow pool boiling when the heated surface was covered with a wire screen mesh, the heat transfer coefficient increased at lower heat fluxes but the critical heat flux (CHF) decreased for all the surfaces tested. In the case of evaporation, both CHF and the heat transfer coefficient increased as the microstructure surfaces were covered with screen meshes.

Gu, C. B.↗

A hydrodynamic model of the oscillating screen viscometer

The viscometer consists of an oscillating screen immersed in a fluid and free to rotate about an axis in its plane. The viscosity can be determined from the measured ratio of the periodic driving force to the screen motion when an adequate hydrodynamical model of the immersed oscillator is available. The screen is formed by a square mesh of thin wire whose dimensions invite comparison with asymptotic results for narrow hollow bodies translating in Stokes flow. These indicate that the closed hole structure of the grid plays an important role in determining its motion. It is shown that this role diminishes as the frequency increases. The computed results, obtained from a system of linear equations, are consistent with experimental values over the appropriate range of frequency.

Davis, A. M. J.↗

Variation with Mach Number of Static and Total Pressures Through Various Screens

Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

Adler, Alfred A↗

The field of a screened magnetic dipole

The purpose of this note is to quantitatively study the asymptotic behavior of the dipole magnetic field in the tail region of a paraboloidal or cylindrical model of the magnetosphere, assuming the complete screening of the internal field by magnetopause currents. This screening assumption is equivalent to imposing the boundary condition that the normal component of the magnetic field is zero at the magnetopause. With this boundary condition, the screened dipole field falls off exponentially with distance down the tail, in sharp constrast to the bare dipole field. Analytic expressions for a cylindrical and paraboloidal magnetopause are given.

Greene, J. M.↗

Comparison of Adsorbed Mercury Screening Method With Cold-Vapor Atomic Absorption Spectrophotometry for Determination of Mercury in Soil

A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.

Easterling, Donald F.↗

Phase Screen Determination for the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency airborne radar interferometric mapping instrument designed to obtain high resolution and high accuracy digital elevation models. The X-band inteferometric antennas are mounted beneath the fuselage with a separation distance of 2.6 m. Midway between the antennas along the aircraft centerline is a large fairing housing the Laser Baseline metrology System (LBMS) and Inertial Navigtion Units (INUs). The P-band antennas are mounted in wingtip pods approximately 10 m from the aircraft centerline. Multipath signals reflected from the LBMS fairing cause phase distortions corrupting the topograhic height measurements for both the X-band and P-band systems. In addition multipath off the wing affects the P-band phase measurements. In this paper we discuss a technique used to mitigate the amount of X-Band multipath and methods calibrating and correcting the phase for both X-Band and P-Band using a high accuracy DEM. Height differences between the interferometrically derived elevations and a photogrammetrically derived DEM are converted into phase differences. Multipath phase errors are sinusoidal with spatial frequency and amplitude related to the magnitude of reflection of the multipath reflection point and its distance from the interferometric antennas. These phase residuals are fitted using a Chebyshev polynomial sequence and used as a phase screen in the processor to correct the phase prior to height reconstruction. Based on the correction signal it is possible to estimate the location and magnitude of the multipath signal. This information can then be used to extend the domain of the phase screen over mapping angles not covered during the calibration passes. Keywords: SAR,interferometry,phase screen

Hensley, Scott↗

Screening for Psychopathology Versus Selecting for Suitability: Ethical and Legal Considerations

The current system for psychological selection of U.S. astronauts is divided into two phases: The select-out phase and the select-in phase. The select-out phase screens candidates for psychopathology; candidates who do not meet the baseline psychiatric requirements are immediately disqualified. The select-in phase assesses candidates for suitability to fly short- and long-duration missions. Suitability ratings are given for ten factors found to be critical for short and long-duration space missions. There are qualitative differences in the purpose of the two phases (select-in vs. select-out) and in the nature of the information collected in each phase. Furthermore, there are different logistic, ethical, and legal issues related to a medical or psychiatric (select-out) screening versus a suitability (select-in) psychological screening process . The purpose of this presentation is to contrast the ethical and legal environment surrounding the select-out and select-in phases of the psychological selection system. Issues such as data collection, data storage and management, the federal statutory environment, and personnel training will be discussed. Further, a summary of the new standards for psychological testing is presented, along with their implications for astronaut selection.

Holland, Albert W.↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical Xrays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Center's Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glenn↗

PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

Teverovsky, Alexander↗

Auto-Thermal Reforming of Jet-A Fuel over Commercial Monolith Catalysts: MicroReactor Evaluation and Screening Test Results

This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.

Yen, Judy C. H.↗

Dynamic balance control in elders: gait initiation assessment as a screening tool

OBJECTIVE: To determine whether measurements of center of gravity-center of pressure separation (CG-CP moment arm) during gait initiation can differentiate healthy from disabled subjects with sufficient specificity and sensitivity to be useful as a screening test for dynamic balance in elderly patients. SUBJECTS: Three groups of elderly subjects (age, 74.97+/-6.56 yrs): healthy elders (HE, n = 21), disabled elders (DE, n = 20), and elders with vestibular hypofunction (VH, n = 18). DESIGN: Cross-sectional, intact-groups research design. Peak CG-CP moment arm measures how far the subject will tolerate the whole-body CG to deviate from the ground reaction force's CP; it represents dynamic balance control. Screening test cutoff points at 16 to 18 cm peak CG-CP moment arm predicted group membership. RESULTS: The magnitude of peak CG-CP moment arm was significantly greater in HE than in DE and VH subjects (p<.01) and was not different between the DE and VH groups. The peak CG-CP moment arm occurred at the end of single stance phase in all groups. As a screening test, the peak moment arm has greater than 50% sensitivity and specificity to discriminate the HE group from the DE and VH groups with peak CG-CP moment arm cutoff points between 16 and 18 cm. CONCLUSIONS: Examining dynamic balance through the use of the CG-CP moment arm during single stance in gait initiation discriminates between nondisabled and disabled older persons and warrants further investigation as a potential tool to identify people with balance dysfunction.

NASA Discipline Neuroscience↗