Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The CNO Concentration in Cosmic Ray Spectrum as Measured From The Advanced Thin Ionization Calorimeter Experiment

We present preliminary results on the spectra of CNO nuclei in the cosmic radiation as measured in the first flight of the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) which lasted for 16 days, starting in December, 2000 with a launch from McMurdo, Antarctica. ATIC is a multiple, long duration balloon flight, investigation for the study of cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pads capable of charge identification in cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction "target".

Fazely, A. R.↗

Fabry-Perot Interferometer-Based Electrooptic Modulator using LiNbO3 and Organic Thin Films

We report the study of a Fabry-Perot electro-optical modulator using thin crystalline film NPP, and Crystalline LiNbO3. We are able to observe 14, and 60 percent degree of modulation. Measurements were carried using a standard lock-in amplifier with a silicon detector. The proposal to design a Fabry-Perot electro-optic modulator with an intracavity electro-optically active organic material was based on the initial results using poled polymer thin films. The main feature of the proposed device is the observation that in traditional electrooptic modulators like a Packets cell, it requires few kilovolts of driving voltage to cause a 3 dB modulation even in high figure-of-merit electrooptic materials like LiNbO3. The driving voltage for the modulator can be reduced to as low as 10 volts by introducing the electrooptic material inside die resonant cavity of a Fabry-Perot modulator. This is because the transmission of the Fabry-Perot cavity varies nonlinearly with the change of refractive index or phase of light due to applied electric field.

Banks, C.↗

Detection of High Energy Cosmic Rays with Advanced Thin Ionization Calorimeter, ATIC

The author presents preliminary results of the first flight of the Advanced Thin Ionization Calorimeter (ATIC). ATIC is a multiple, long duration balloon flight, investigation for the study of cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pads capable of charge identification of cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction 'target'.

Adams, J. H.↗

Detection of High Energy Cosmic Ray with the Advanced Thin Ionization Calorimeter (ATIC)

ATIC is a balloon-borne investigation of cosmic ray spectra, from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Gemmate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pixels capable of charge identification in cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction 'target'. Very high energy gamma-rays and their energy spectrum may provide insight to the flux of extremely high energy neutrinos which will be investigated in detail with several proposed cubic kilometer scale neutrino observatories in the next decade.

Fazely, Ali R.↗

Results from the Martian Radiation Environment Experiment MARIE

One of the three science instruments aboard the 2001 Mars Odyssey spacecraft is the Martian Radiation Environment Experiment, MARIE. MARIE consists of a stack of silicon detectors, augmented by a Cerenkov detector. MARIE is designed to measure a portion of the particle spectrum of the Galactic Cosmic Rays (GCR), as well as the high fluxes of low-energy protons (energies less than about 100 MeV) that are intermittently produced by active regions on the sun in Solar Particle Events (SPE). MARIE is providing the first detailed information about the radiation environment near Mars.measurements. MARIE has been operating successfully for nearly a year. Solar particle events of considerable interest have been observed, and data have been obtained that will yield GCR spectra from a novel observation point in the solar system.

Zeitlin, C.↗

Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

manned↗

Heavy fragment production cross sections from 1.05 GeV/nucleon 56Fe in C, Al, Cu, Pb, and CH2 targets

We have obtained charge-changing cross sections and partial cross sections for fragmentation of 1.05 GeV/nucleon Fe projectiles incident on H, C, Al, Cu, and Pb nuclei. The energy region covered by this experiment is critical for an understanding of galactic cosmic ray propagation and space radiation biophysics. Surviving primary beam particles and fragments with charges from 12 to 25 produced within a forward cone of half-angle 61 mrad were detected using a silicon detector telescope to identify their charge and the cross sections were calculated after correction of the measured yields for finite target thickness effects. The cross sections are compared to model calculations and to previous measurements. Cross sections for the production of fragments with even-numbered nuclear charges are seen to be enhanced in almost all cases.

NASA Center HQS↗

The fragmentation of 670A MeV neon-20 as a function of depth in water. I. Experiment

We present the final analysis of an experiment to study the interaction of a beam of 670A MeV neon ions incident on a water column set to different thicknesses. The atomic number Z (and, in some cases, the isotopic mass A) of primary beam particles and of the products of nuclear interactions emerging from the water column close to the central axis of the beam was obtained for nuclei between Be (Z = 4) and Ne (Z = 10) using a time-of-flight telescope to measure the velocity and a set of silicon detectors to measure the energy loss of each particle. The fluence of particles of a given charge was obtained and normalized to the incident beam intensity. Corrections were made for accidental coincidences between multiple particles triggering the TOF telescope and for interactions in the detector. The background due to beam particles interacting in beam line elements upstream of the detector was calculated. Sources of experimental artifacts and background in particle identification experiments designed to characterize heavy ion beams for radiobiological research are summarized, and some of the difficulties inherent in this work are discussed. Complete tables of absolutely normalized fluence spectra as a function of LET are included for reference purposes.

NASA Discipline Radiation Health↗

Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Cosmic Radiation↗

Real-Time Radiographic In-Situ Characterization Of Ply Lift In Composite Aerospace Materials

The problem of ply lifting in composite materials is a significant issue for various aerospace and military applications. A fundamental element in the prevention or mitigation of ply lift is determination of the timing of the ply lifting event during exposure of the composite material to flight conditions. The Marshall Space Flight Center s Nondestructive Evaluation Team developed a real-time radiographic technique for the detection of ply lift in carbon phenolic ablative materials in situ during live firings of subscale test motors in support of NASA s Reusable Solid Rocket Motor program, using amorphous silicon detector panels. The radiographic method has successfully detected ply lifting in seven consecutive carbon phenolic converging cones attached to solid fuel torches, providing the time of ply lift initiation in each test. Post-processing of the radiographic images improved the accuracy of timing measurements and allowed measurement of the ply lifting height as a function of time. Radiographic data correlated well with independent pressure and temperature measurements that indicate the onset of ply lift in the nozzle material.

Beshears, Ronald D.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

The Energetic Trans-Iron Nuclei Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)" which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.3 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of ~20 m2sr. Measurements made in space for a period of 3 years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized heavy elements (Pu and Cm), what the age of that component is, and test the model of the OB association origin of galactic cosmic rays. Additionally, it will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas.

Binns, W. R.↗

The Energetic Trans-Iron Cosmic-ray Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)", which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.5 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of approx.20 sq m sr. Measurements made in space for a period of three years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized transuranic elements (Pu-94 and Cm-96), to measure the age of that component, and to test the model of the OB association origin of galactic cosmic rays. Additionally, these observations will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas. Keywords: cosmic rays Galaxy:abundances

Binns, W. R.↗

Modeling the Proton Radiation Belt With Van Allen Probes Relativistic Electron-Proton Telescope Data

An empirical model of the proton radiation belt is constructed from data taken during 2013-2017 by the Relativistic Electron-Proton Telescopes on the Van Allen Probes satellites. The model intensity is a function of time, kinetic energy in the range 18-600 megaelectronvolts, equatorial pitch angle, and L shell of proton guiding centers. Data are selected, on the basis of energy deposits in each of the nine silicon detectors, to reduce background caused by hard proton energy spectra at low L. Instrument response functions are computed by Monte Carlo integration, using simulated proton paths through a simplified structural model, to account for energy loss in shielding material for protons outside the nominal field of view. Overlap of energy channels, their wide angular response, and changing satellite orientation require the model dependencies on all three independent variables be determined simultaneously. This is done by least squares minimization with a customized steepest descent algorithm. Model uncertainty accounts for statistical data error and systematic error in the simulated instrument response. A proton energy spectrum is also computed from data taken during the 8 January 2014 solar event, to illustrate methods for the simpler case of an isotropic and homogeneous model distribution. Radiation belt and solar proton results are compared to intensities computed with a simplified, on-axis response that can provide a good approximation under limited circumstances.

Selesnick, R. S.↗

Uncooled Doped-Si Thermopiles for Thermal Land Imaging Applications

Sustained and enhanced land imaging is crucial for providing high-quality science data on change in land use, forest health, environment, and climate. Future thermal land imaging instruments operating in the 10-12 micron band will provide essential information for furthering our hydrologic understanding at scales of human influence, and producing field-scale moisture information through accurate retrievals of evapotranspiration (ET). To address the need for cost-effective future thermal land imaging missions we are developing novel uncooled doped-silicon thermopile detectors, an extension of a detector design concept originally developed at NASA-Goddard for planetary science applications. These doped-Si thermopile detectors have the potential to offer superior performance in terms of sensitivity, speed, and customization, when compared to current commercial-off-the-shelf uncooled detector technologies. Because cryocooler technology does not need to be fielded on the instrument, these and other uncooled detectors offer the benefit of greatly reduced instrument cost, mass, and power at the expense of some acceptable loss in detector sensitivity. We present the motivation for an uncooled thermal imaging instrument, our doped-Si thermopile detector concept, and performance expectations and comparisons. We also provide an update on the current status of this detector technology development.

Thermopiles↗

Intensified silicon photodiode array detector linearity Application to coherent anti-Stokes Raman spectroscopy

The linearity of an intensified silicon photodiode array multichannel detector is studied with coherent anti-Stokes Raman and other similar signals. Studies with diffuse and focused (spherically and cylindrically) signals resolved apparent saturation problems which limit the dynamic range of the detector. In addition, it has been shown that there is no short-range wavelength (473-532-nm) dependence on this saturation. Theoretical explanations for these phenomena are also included.

Antcliff, R. R.↗

Neutral particle background in cosmic ray telescopes composed of silicon solid state detectors

The energy loss-spectrum of secondary charged particles produced by the interaction of gamma-rays and energetic neutrons in silicon solid state detectors has been measured with a satellite-borne cosmic ray telescope. In the satellite measurements presented here two distinct neutral background effects are identified: secondary protons and alpha particles with energies of about 2 to 100 MeV produced by neutron interactions, and secondary electrons with energies of about 0.2 to 10 MeV produced by X-ray interactions. The implications of this neutral background for satellite measurements of low energy cosmic rays are discussed, and suggestions are given for applying these results to other detector systems in order to estimate background contamination and optimize detector system design.

Mewaldt, R. A.↗

Predictions of silicon avalanche photodiode detector performance in water vapor differential absorption lidar

Performance analyses are presented which establish that over most of the range of signals expected for a down-looking differential absorption lidar (DIAL) operated at 16 km the silicon avalanche photodiode (APD) is the preferred detector for DIAL measurements of atmospheric water vapor in the 730 nm spectral region. The higher quantum efficiency of the APD's, (0.8-0.9) compared to a photomultiplier's (0.04-0.18) more than offsets the higher noise of an APD receiver. In addition to offering lower noise and hence lower random error the APD's excellent linearity and impulse recovery minimize DIAL systematic errors attributable to the detector. Estimates of the effect of detector system parameters on overall random and systematic DIAL errors are presented, and performance predictions are supported by laboratory characterization data for an APD receiver system.