Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Delaminations Investigated With Ultrasonic Spectroscopy

A previous study suggested that the ultrasonic spectroscopy technique identified possible disbonds or delaminations in polymer matrix composite (PMC) rings sectioned from flywheel rotors (ref. 1). These results went unsubstantiated by other nondestructive evaluation (NDE) methods. To explain the results, PMC rings were further investigated with ultrasonic spectroscopy (ref. 2). The ultrasonic spectroscopy system utilizes a continuous-swept sine waveform as the input. After the swept sine wave traverses the material, the captured waveform is subjected to two fast Fourier transforms. The second fast Fourier transform along with equalization of the frequency spectrum, allows for evaluation of the fundamental resonant frequency. The full-thickness resonance, the resonance corresponding to the location of the intentional disbond, and the frequency spectrum were examined in an effort to characterize the sensitivity of the NDE method to various delamination conditions.

Cosgriff, Laura M.↗

Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

Schwarze, Gene E.↗

High-Voltage, Asymmetric-Waveform Generator

The shapes of waveforms generated by commercially available analytical separation devices, such as some types of mass spectrometers and differential mobility spectrometers are, in general, inadequate and result in resolution degradation in output spectra. A waveform generator was designed that would be able to circumvent these shortcomings. It is capable of generating an asymmetric waveform, having a peak amplitude as large as 2 kV and frequency of several megahertz, which can be applied to a capacitive load. In the original intended application, the capacitive load would consist of the drift plates in a differential-mobility spectrometer. The main advantage to be gained by developing the proposed generator is that the shape of the waveform is made nearly optimum for various analytical devices requiring asymmetric-waveform such as differential-mobility spectrometers. In addition, this waveform generator could easily be adjusted to modify the waveform in accordance with changed operational requirements for differential-mobility spectrometers. The capacitive nature of the load is an important consideration in the design of the proposed waveform generator. For example, the design provision for shaping the output waveform is based partly on the principle that (1) the potential (V) on a capacitor is given by V=q/C, where C is the capacitance and q is the charge stored in the capacitor; and, hence (2) the rate of increase or decrease of the potential is similarly proportional to the charging or discharging current. The proposed waveform generator would comprise four functional blocks: a sine-wave generator, a buffer, a voltage shifter, and a high-voltage switch (see Figure 1). The sine-wave generator would include a pair of operational amplifiers in a feedback configuration, the parameters of which would be chosen to obtain a sinusoidal timing signal of the desired frequency. The buffer would introduce a slight delay (approximately equal to 20 ns) but would otherwise leave the fundamental timing signal unchanged. The buffered timing signal would be fed as input to the level shifter. The output of the level shifter would serve as a timing and control signal for the high-voltage switch, causing the switch to alternately be (1) opened, allowing the capacitive load to be charged from a high-voltage DC power supply; then (2) closed to discharge the capacitive load to ground. Hence, the output waveform would closely approximate a series of exponential charging and discharging curves (see Figure 2).

Beegle, Luther W.↗

Digital Receiver Phase Meter

The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

Marcin, Martin↗

Prediction of Spacecraft Vibration using Acceleration and Force Envelopes

The base forces in the GLAST X- and Z-axis sine vibration tests were similar to those derived using generic inputs (from users guide and handbook), but the base forces in the sine test were generally greater than the flight data. Basedrive analyses using envelopes of flight acceleration data provided more accurate predictions of the base force than generic inputs, and as expected, using envelopes of both the flight acceleration and force provided even more accurate predictions The GLAST spacecraft interface accelerations and forces measured during the MECO transient were relatively low in the 60 to 150 Hz regime. One may expect the flight forces measured at the base of various spacecraft to be more dependent on the mass, frequencies, etc. of the spacecraft than are the corresponding interface acceleration data, which may depend more on the launch vehicle configuration.

Gordon, Scott↗

Phase measurement device using inphase and quadrature components for phase estimation

A phasemeter for estimating the phase of a signal. For multi-tone signals, multiple phase estimates may be provided. An embodiment includes components operating in the digital domain, where a sampled input signal is multiplied by cosine and sine terms to provide estimates of the inphase and quadrature components. The quadrature component provides an error signal that is provided to a feedback loop, the feedback loop providing a model phase that tends to track the phase of a tone in the input signal. The cosine and sine terms are generated from the model phase. The inphase and quadrature components are used to form a residual phase, which is added to the model phase to provide an estimate of the phase of the input signal. Other embodiments are described and claimed.

Halverson, Peter G.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

A New Large Vibration Test Facility Concept for the James Webb Space Telescope

The James Webb Space Telescope consists of three main components, the Integrated Science Instrument Module (ISIM) Element, the Optical Telescope Element (OTE), and the Spacecraft Element. The ISIM and OTE are being assembled at the National Aeronautics and Space Administration's Goddard Spaceflight Center (GSFC). The combined OTE and ISIM Elements, called OTIS, will undergo sine vibration testing before leaving Goddard. OTIS is the largest payload ever tested at Goddard and the existing GSFC vibration facilities are incapable of performing a sine vibration test of the OTIS payload. As a result, a new large vibration test facility is being designed. The new facility will consist of a vertical system with a guided head expander and a horizontal system with a hydrostatic slip table. The project is currently in the final design phase with installation to begin in early 2015 and the facility is expected to be operational by late 2015. This paper will describe the unique requirements for a new large vibration test facility and present the selected final design concepts.

test facilities↗

A New Large Vibration Test Facility Concept for the James Webb Space Telescope

The James Webb Space Telescope consists of three main components, the Integrated Science Instrument Module (ISIM) Element, the Optical Telescope Element (OTE), and the Spacecraft Element. The ISIM and OTE are being assembled at the National Aeronautics and Space Administration's Goddard Spaceflight Center (GSFC). The combined OTE and ISIM Elements, called OTIS, will undergo sine vibration testing before leaving Goddard. OTIS is the largest payload ever tested at Goddard and the existing GSFC vibration facilities are incapable of performing a sine vibration test of the OTIS payload. As a result, a new large vibration test facility is being designed. The new facility will consist of a vertical system with a guided head expander and a horizontal system with a hydrostatic slip table. The project is currently in the final design phase with installation to begin in early 2015 and the facility is expected to be operational by late 2015. This paper will describe the unique requirements for a new large vibration test facility and present the selected final design concepts.

vibration↗

Fixed Base Modal Testing Using the NASA GRC Mechanical Vibration Facility

The Space Power Facility at NASA's Plum Brook Station houses the world's largest and most powerful space environment simulation facilities, including the Mechanical Vibration Facility (MVF), which offers the world's highest-capacity multi-axis spacecraft shaker system. The MVF was designed to perform sine vibration testing of a Crew Exploration Vehicle (CEV)-class spacecraft with a total mass of 75,000 pounds, center of gravity (cg) height above the table of 284 inches, diameter of 18 feet, and capability of 1.25 gravity units peak acceleration in the vertical and 1.0 gravity units peak acceleration in the lateral directions. The MVF is a six-degree-of-freedom, servo-hydraulic, sinusoidal base-shake vibration system that has the advantage of being able to perform single-axis sine vibration testing of large structures in the vertical and two lateral axes without the need to reconfigure the test article for each axis. This paper discusses efforts to extend the MVF's capabilities so that it can also be used to determine fixed base modes of its test article without the need for an expensive test-correlated facility simulation.

Modal Test and Analysis↗

Global Ecosystem Dynamics Investigation (GEDI) Structural Verification Unit (SVU) Vibration Test

This presentation describes the vibration test campaign of the Structural Verification Unit for the Global Ecosystem Dynamics Investigation (GEDI) mission The Structural Verification Unit test campaign served multiple purposes including the qualification of the instrument primary structure, verification of the structure's stiffness, Aperture Control Mechanism assembly level verification, and validation of the control approach for protoflight instrument vibration testing. Testing included three axes of sine burst, random, and sine vibration excitation. This test sequence required a high number of response instrumentation sensors that included tri-axial accelerometers and tri-axial force gauges. Multiple response limiting methods that included acceleration, force, and moment measurements were used to ensure the safety of the flight hardware. The lessons and specific test details learned on the structural verification unit test campaign will reduce test risks for the upcoming instrument-level vibration tests.

Structural Verification Unit↗

Evaluation of Conservatism in Low Frequency Vibration Test Control

Aerospace structures are typically qualified for low frequency flight environments by using a swept-sine vibration test method. However, this ground testing has a tendency to produce substantial overtesting at certain frequencies. This paper presents an evaluation of the response conservatism present with a typical swept-sine and two transient vibration tests when applied to a typical spacecraft component. The absolute conservatism between a typical launch transient response and the test environment responses is measured using alternative characterizations of transient vibrations previously used in shock testing. The characterizations used include the Shock Intensity Spectrum, Shock Response Spectrum, Acceleration Root Mean Square in both frequency and time domains, and Ranked Peaks. Control of the test/flight conservatism is shown to be possible through the overtest factor (OTF) parameter.

Conservatism↗

NICER X-ray Observations of Seven Nearby Rotation-powered Millisecond Pulsars

The Neutron star Interior Composition Explorer observed several rotation-powered millisecond pulsars (MSPs) to search for or confirm the presence of X-ray pulsations. When broad and sine-like, these pulsations may indicate thermal emission from hot polar caps at the magnetic poles on the neutron star surface. We report confident detections (≥4.7σ after background filtering) of X-ray pulsations for five of the seven pulsars in our target sample: PSR J0614−3329, PSR J0636+5129, PSR J0751+1807, PSR J1012+5307, and PSR J2241−5236, while PSR J1552+5437 and PSR J1744−1134 remain undetected. Of those, only PSR J0751+1807 and PSR J1012+5307 had pulsations previously detected at the 1.7σ and almost 3σ confidence levels, respectively, in XMM-Newton data. All detected sources exhibit broad sine-like pulses, which are indicative of surface thermal radiation. As such, these MSPs are promising targets for future X-ray observations aimed at constraining the neutron star mass–radius relation and the dense matter equation of state using detailed pulse profile modeling. Furthermore, we find that three of the detected MSPs exhibit a significant phase offset between their X-ray and radio pulses.

Sebastien Guillot↗

Benchmark Data for Evaluation of NASA Impedance Eduction Methods

Results achieved with three acoustic liner configurations are used to evaluate the effects of recent modifications to the NASA Normal Incidence Tube and Grazing Flow Impedance Tube. These include a calibration liner, a wire mesh liner, and a perforate liner. The effects of source type, source level, and mean flow Mach number on the impedances educed with these liners are explored. Existing models are used to predict the impedance for each test condition and are compared with educed impedance spectra to determine their validity. The results suggest that educed impedances are similar for either a stepped sine or swept sine source. The predicted models are acceptable for the perforate liner and are quite good for the calibration and wire mesh liners.

acoustic↗

Benchmark Data for Evaluation of NASA Impedance Eduction Methods

Results achieved with three acoustic liner configurations are used to evaluate the effects of recent modifications to the NASA Normal Incidence Tube and Grazing Flow Impedance Tube. These include a calibration liner, a wire mesh liner, and a perforate liner. The effects of source type, source level, and mean flow Mach number on the impedances educed with these liners are explored. Existing models are used to predict the impedance for each test condition, and are compared with educed impedance spectra to determine their validity. The results suggest that educed impedances are similar for either a stepped sine or swept sine source. The predicted models are acceptable for the perforate liner, and are quite good for the calibration and wire mesh liners.

acoustic↗

Computationally Efficient Frequency Domain Method for Dynamic Control Derivative Estimation with Application to Transonic Truss-Braced Wing

This paper presents a computationally efficient method for dynamic control derivative estimation technique via control surface oscillation numerical experiments. Unsteady RANS CFD simulations in FUN3D are performed to simulate the control surface oscillations with a prescribed truncated square wave containing sufficient frequencies of interest. The truncated square wave oscillation offers the computational efficiency which reduces the computational cost by almost an order of magnitude compared to a sine wave oscillation. The nonlinear effect of large control surface oscillation amplitudes creates a spillover effect whereby the frequency response at the same input frequencies contains not only the linear aerodynamic response but also nonlinear aerodynamic response. A correction procedure is developed to remove the spillover effect from the linear aerodynamic response. A frequency-domain regression is performed to estimate the dynamic control derivatives after the correction. The results generally agree with the previous results obtained from the sine wave oscillation.

Stability and Control↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Enhancing photoionization rate calculations in low-temperature plasmas using spectral methods

Photoionization plays a central role in the development of streamer discharges and other non-equilibrium plasma phenomena. It creates seed electrons, which are essential for positive streamer propagation, allowing the ionization front to move forward. Because of this, accurate modeling of photoionization is very important for predicting streamer behavior and plasma evolution. The photoionization process in air (N 2 – O 2 mixture) is often described by the Zheleznyak model (1982). This model is usually solved through Helmholtz-type equations that approximate the Zheleznyak photoionization model (Zheleznyak et al. 1982) as Partial Differential Equations (PDEs). Conventional numerical methods, such as the Finite Difference Method (FDM) or Finite Volume Method (FVM), are widely used to solve these equations. Although they are prevalent, the computational cost of these methods due to their need for matrix operations and iterative solver is demanding. To address this challenge, this work develops a spectral solver based on the Fast Fourier Transform (FFT) combined with Discrete Cosine Transform (DCT) and Discrete Sine Transform (DST) to calculate the photoionization rate efficiently in an axisymmetric cylindrical domain. This method naturally satisfies the boundary conditions used in the model and converts the PDE into algebraic ones in spectral space. Thus, avoids the need for iterative matrix solvers. When compared with FDM results, it is demonstrated that the new solver not only maintains accuracy, but also reduces the computational cost, showing a performance increase of approximately 100 compared to FDM over a wide range of problem sizes. The method is parallelized using Message Passing Interface (MPI) and has been integrated into a fluid plasma model for streamer simulation. Here, this FFT-based approach provides a fast and reliable alternative for calculating photoionization in fluid models, helping large-scale plasma simulations run faster and efficiently, and allows higher-resolution simulation without extra computational cost.

Axisymmetric system↗