Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

151 records · Page 9

Common Information Model for Electromagnetic Transients (CIM for EMT): CRADA 533 [Abstract only}

The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TROPOMI observations allow for robust exploration of the relationship between solar-induced chlorophyll fluorescence and terrestrial gross primary production

Solar-induced chlorophyll fluorescence (SIF) observed by satellites has advanced the monitoring of terrestrial photosynthesis regionally and globally. The relationship between SIF and gross primary production (GPP) at leaf, canopy, and ecosystem scales has received tremendous attention in recent years. It remains controversial whether the SIF-GPP relationship at the ecosystem scale is universal or dependent upon vegetation type. New SIF observations from the TROPOspheric Monitoring Instrument (TROPOMI) with unprecedented high spatial and temporal resolution provide a new opportunity to elucidate the SIF-GPP relationship. Here, we examine the SIF-GPP relationship for seven major vegetation types across the U.S. with TROPOMI SIF and in-situ GPP data for 83 eddy covariance flux sites. We find that TROPOMI SIF shows a strong and consistent relationship with tower-based GPP at both satellite footprint and grid-cell levels. The slope of the SIF-GPP relationship is similar among all the vegetation types except croplands, demonstrating a nearly universal (converging to ~13.5 g C m -2 d -1 /W m -2 μm -1 sr -1) rather than vegetation type-specific SIF-GPP relationship. This confirms that TROPOMI SIF can be used as a proxy for GPP across a wide variety of vegetation types and can also be used to quantify GPP by avoiding uncertainty associated with land cover maps. The C 4 crops have a much higher slope than the C 3 crops, and therefore croplands tend to have a higher slope than C 3 -dominated vegetation types (e.g., forests, shrublands, savannas). We also find that the TROPOMI SIF is well correlated with GPP under normal or wetter conditions, while their relationship becomes weaker under water stress. In conclusion, our TROPOMI-based study could improve our understanding of the SIF-GPP relationship at the ecosystem scale and advance the mapping of GPP globally with SIF observations from space.

54 ENVIRONMENTAL SCIENCES↗

Equivalent Breakeven Installed Cost: A Tradeoff-Informed Measure for Technoeconomic Analysis of Candidate Heliostat Improvements

Technoeconomic analysis (TEA) is commonly used to determine economic viability of power-generating technologies, including concentrating solar power (CSP) and thermal (CST) production plants. Levelized cost of electricity (LCOE) and analogous measures provide an estimate of long-term costs for operating power plants over their designed lifetimes by accounting for revenues and costs in a time-discounted manner. While these measures are effective when assessing a technology’s total lifecycle costs and productivity under various designs, TEA of candidate incremental technology improvements from the lens of LCOE can be limited when required investment and LCOE impacts are small. In this work, we propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. We illustrate the usefulness of this metric using the example of candidate heliostat improvements for a CSP tower plant. Here, the results suggest that a reduction in mirror washing costs yield a total plant O&M cost of $37/kWe-yr, which is a breakeven proposition if the average reflectance is reduced from 0.90 to 0.85 as a result of the cost savings.

Zolan, Alexander (ORCID:0000000326017604)↗

Generating high-resolution total canopy SIF emission from TROPOMI data: Algorithm and application

Solar-induced chlorophyll fluorescence (SIF) is a rapidly advancing front in modeling global terrestrial gross primary production (GPP). Canopy total SIF emissions (SIF total ) are mechanistically linked to the plant photosynthesis, and can be estimated from satellite observed SIF (SIF obs ) through radiative transfer modeling. However, the current satellite SIF obs and thus SIF total are available only at coarse spatial resolutions from several kilometers to tens of kilometers, inhibiting the application at fine spatial scales. Here, in this work, we proposed an algorithm to generate both global high-resolution SIF total (HSIF total ) and high-resolution SIF obs (HSIF obs ) at 1 km from low-resolution SIF obs (LSIF obs ) from the TROPOspheric Monitoring Instrument (TROPOMI), which has a spatial resolution at nadir of 3.5 km by 5.6–7 km. Our statistical method is based on the law of energy conservation and uses satellite derived fraction of absorbed photosynthetically active radiation, fluorescence efficiency, and the escape probability of fluorescence. We evaluated the accuracy of our HSIF total using the Orbiting Carbon Observatory-2 SIF (R 2 = 0.78). We found that the spatial resolution had clear effects on the relationship between HSIF total and GPP. We also compared HSIF total to 8-day averaged tower GPP from 135 flux sites and found that they were better correlated when HSIF total was averaged over a 1-km radius around the tower than when averaged over a larger radius. Our study provided a unique high-resolution HSIF total product, which will advance the estimation of GPP by extrapolating site-level relationships to the global scale.

54 ENVIRONMENTAL SCIENCES↗

Stand-Alone and Hybrid Electric Thermal Energy Storage in the System Advisor Model

This project developed stand-alone electric-thermal energy storage (ETES), stand-alone pumped thermal energy storage (PTES), and hybrid molten-salt power tower (MSPT)-ETES performance and dispatch optimization techno-economic models. The models are available to the public through the System Advisor Model (SAM) software, scripting, and as open-source code. We compared results of the dispatch model to PLEXOS dispatch of a similar generator using the same initial grid pricing signal and found our dispatch model performed well, but closer agreement between the models was limited by the inherent differences between price-taker and unit commitment models. Nevertheless, the price-taker models developed in this project are useful to analyze proposed ETES and PTES technologies because they provide more detailed system and component models, solve several orders of magnitude faster, and are available as free open-source software. The model results represent the most optimistic returns considering grid arbitrage from the input electricity pricing, so the financial results can be applied as a feasibility stage-gate. We also submitted a journal draft paper that describes the ETES dispatch model methodology and demonstrates model functionality. An accepted journal article will serve as peer-reviewed documentation for the models, along with the open-source code, SAM help-menu content, and eventually this final project report.

14 SOLAR ENERGY↗

NGEE Arctic CO2, CH4 and Energy Eddy-Covariance (EC) Flux Tower Auxiliary Measurements, Utqiagvik (Barrow), Alaska, 2012 - 2019

Measurements began in September 2012 and are generally made throughout the snow-free growing season starting from April (pre-thawing) until November (freeze-up) when the instrumentation is taken down for maintenance and instrument calibration. CO2, CH4 and energy fluxes using the Eddy Covariance (EC) technique (Baldocchi 2003) and meteorological measurements are reported as 30-minute averages. The tower site is registered with AmeriFlux as US-NGB. See http://ameriflux.lbl.gov/sites/siteinfo/US-NGB for more information. Reported data include: (1) additional/extra meteorological and eddy covariance CO2, CH4 and energy flux data, (2) binned spectra for the three wind components, the sonic temperature and gas densities together with the binned cospectra for covariances of w (vertical wind component) and gas densities, (3) binned ogives (cumulative (co)spectra) for the three wind components, the sonic temperature and gas densities, and (4) tower site footprint matrices. Meteorological and eddy covariance CO2, CH4 and energy flux data (AmeriFlux BASE data product) are available from AmeriFlux https://doi.org/10.17190/AMF/1436326. The tower site is adjacent to the NGEE Arctic Tram system with several complementary time-series measurements https://doi.org/10.5440/1558782.This dataset supersedes the previously released dataset "Eddy-Covariance and auxiliary measurements, NGEE-Barrow, 2012-2013" DOI:10.5440/1124200 as this new product includes data for the longer time period processed using consistent methods for the entire record. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) near Utqiagvik (Barrow), Alaska and 2) multiple areas in the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗