Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Technology Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Open-Source Framework for Rapid Validation of Scientific ASICs

Spacely is an open-source framework for the post-silicon validation of analog, digital, and mixed-signal ASICs (Application-Specific Integrated Circuits) which maximizes the reuse of hardware and software, reducing the time taken to achieve meaningful test results. Spacely specifically addresses the needs of small, flexible ASIC design teams commonly found in academia or research institutions which benefit most from sharing the overhead of test stand creation between many unique ASIC designs. Spacely is a set of software, firmware, and design practices. It targets two primary hardware platforms (NI-PXI and Caribou) as well as offering extensible support for bench instruments. Spacely provides a high-level Python interface to all test hardware for accessibility, while also giving more sophisticated teams the opportunity to integrate custom test firmware. The design principles of Spacely are presented, along with a demonstrative example of using Spacely to test a pixel detector readout ASIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fusion product measurements by nuclear diagnostics in the Joint European Torus deuterium–tritium 2 campaign (invited)

We report a new deuterium–tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 10 17 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Influence of Vegetation Canopy Architecture on Dynamics of Spatiotemporal Light Distribution and its Effect on Land-Biosphere-Atmosphere Fluxes of Energy, Carbon, and Water

The dynamic spatiotemporal distribution of light and micro climatic variables (wind speed, atmospheric CO 2 concentration, humidity, pressure, and air temperature) within the plant canopy as determined by the canopy architecture play a critical role in land-biosphere-atmosphere (LBA) photosynthetic carbon uptake, transpiratory water loss and energy partitioning. Vegetation models that include effects of sun and shade flecks, leaf temperature and energy balance partitioning between sensible and latent heat fluxes, and reduced turbulent mixing in dense vegetation canopies can accurately predict canopy performance, particularly its shaded leaves, which can constitute 80% of leaf area and contribute up to 50% of carbon update and 65% of water loss. However, current vegetation models with their bulk characterization of shaded leaves poorly represent the complex three dimensional (3D) canopy architecture are insufficient to capture the spatiotemporal dynamics of shaded leaves. Here, we propose to employ an x-ray computed tomography (XCT) imaging technique in combination with an automated, high throughput, image processing pipeline (3DArch, to be developed) to obtain an explicit 3D triangulated surface mesh of a plant canopy (Fig 1). 3DArch would provide a much needed technological jump in 3D LBA modeling where computer generated artificial 3D models suffer from lack of high resolution detailed canopy architecture parameters. The 3D canopy surface mesh output from 3DArch is coupled with an explicit 3D forward ray tracing model (fastTracer) to obtain a high resolution representation of the dynamic spatiotemporal light environment within the canopy over the course of a day (Fig 1). The results from the light attenuation model are then coupled with a process based multi-scale bio-physical canopy and leaf model of photosynthesis (PlantGro) to get fluxes of carbon, water and energy at the leaf and canopy scale, in addition to estimating whole plant carbon uptake, and water loss. Our proposed model framework would be the first of its kind to provide a breakthrough capability in the field of process-based plant modeling that bridges the key technological gap in shaded leaf modeling through explicit representation of 3D canopy architecture. Computer generated artificial 3D model canopy simulations on grasses show that the canopy light distribution does not follow an exponential behavior as assumed in most 1D vegetation models, but rather exhibits a heterogeneous behavior, with a small but significant portion of interior canopy leaves experiencing peak light levels due to sun flecks while the rest of the canopy receives substantially lower light levels. These results indicate a bias in traditional models that overestimates shaded leaf contribution towards whole canopy photosynthesis by up to 15% and underestimate transpiration by up to 12% with an associated increase in sensible heat fluxes since photosynthesis, transpiration and energy partitioning are tightly coupled processes. However, these test results need to be validated using the 3D architecture obtained from a real plant imaged in 3D using 3DArch, rather than an artificial model plant. Our proposed model framework would allow us to identify inefficiencies in canopy light distribution and prescribe optimal canopy architectures (leaf optical properties, leaf area, leaf angles, row spacing, planting density, etc.) to traditional and genetic engineering based crop breeders, for maximizing target functions such as light use efficiency, water use efficiency, drought tolerance, crop yield, crop resilience etc., with important applications in biofuel crops such as sorghum, and switchgrass. Our model can also be applied for designing optimal canopy architecture that increase surface albedo as a mitigation strategy for global warming and projections of crop yield for future food and water security under climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges and Opportunities in Magnetospheric Space Weather Prediction

Abstract Space Weather is the study of the dynamics of the coupled Solar‐Terrestrial environment, as these dynamics impact technological systems and human activity. This paper reviews a selection of the advances, challenges, and new opportunities for magnetospheric space weather, and while the focus is on specific phenomena, many other aspects of space weather will have similar challenges and needs. As a scientific field with direct applications, the field of space weather is partly driven by imperatives from both policy and operations. We provide an introduction to some of the context in which the field exists and discuss how this might shape future developments and norms within the space weather enterprise. We briefly examine benchmarking, as a policy and operationally driven activity, as it provides immediate societal relevance and an opportunity to stretch scientific understanding. As numerical space weather prediction now becomes routine, and exascale computing is in the near future, we identify challenges relating to computational expense and big data, capturing and accounting for uncertainties, and specification of boundary conditions. Here, as with the observations supporting numerical space weather prediction, the key challenge lies in extending the lead time of predictions. We also discuss the role of data, particularly in regard to model validation and empirical modeling. Due to the growing societal impact of space weather, we also examine the relationships between space weather and its terrestrial counterpart and look at the importance of continuous evaluation, monitoring progress in predictive capability, and communication with researchers, forecasters, and end users.

79 ASTRONOMY AND ASTROPHYSICS↗

High-efficiency catalytic reduction of residual oxygen for purification of carbon dioxide streams from high-pressure oxy-combustion systems

Pressurized oxy-combustion is a promising technology for carbon capture, utilization, and storage. For the captured CO 2 to be used for enhanced oil recovery or stored in geological formations, flue gas impurities, including residual O 2 in the CO 2 stream, must be purified to meet the purity specifications. A catalytic approach to reducing residual O 2 with CH 4 was investigated in this study. Five CoMn- and Cu-based catalysts were synthesized or acquired, and a reverse-flow fixed-bed reactor was used to assess their performance for O 2 removal from a simulated oxy-combustion flue gas at 15 bar. The impacts of the operating parameters on O 2 removal, such as temperature, gas hourly space velocity, O 2 /CH 4 ratio, and gas pressure, were investigated. Among the tested catalysts, the two CoMn catalysts were superior in both activity and selectivity, with the reaction lighting off at about 350 °C and achieving 99% O 2 removal at about 500 °C. Finally, the kinetics of the catalytic reaction is discussed, and the Mars–van Krevelen redox mechanism is deemed valid for describing the reaction pathway for the top-performing CoMn catalysts. The catalytic reaction was determined to be first order in CH 4 and zero order in O 2 under the test conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An improved synthetic signal injection routine for HAYSTAC

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of 10-24 W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion's spectral distribution, which is derived from a Maxwell-Boltzmann distribution. In addition, we show that the synthetic axion's power can be calibrated with reference to the system noise. Compared to the synthetic axion injection in HAYSTAC phase I, we demonstrated synthetic signal injection with a more realistic lineshape and calibrated power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Dissipative ground state preparation in ab initio electronic structure theory

Dissipative engineering is a powerful tool for quantum state preparation, and has drawn significant attention in quantum algorithms and quantum many-body physics in recent years. In this work, we introduce a novel approach using the Lindblad dynamics to efficiently prepare the ground state for general ab initio electronic structure problems on quantum computers, without variational parameters. These problems often involve Hamiltonians that lack geometric locality or sparsity structures, which we address by proposing two generic types of jump operators for the Lindblad dynamics. Type-I jump operators break the particle number symmetry and should be simulated in the Fock space. Type-II jump operators preserves the particle number symmetry and can be simulated more efficiently in the full configuration interaction space. For both types of jump operators, we prove that in a simplified Hartree-Fock framework, the spectral gap of our Lindbladian is lower bounded by a universal constant. For physical observables such as energy and reduced density matrices, the convergence rate of our Lindblad dynamics with Type-I jump operators remains universal, while the convergence rate with Type-II jump operators only depends on coarse grained information such as the number of orbitals and the number of electrons. To validate our approach, we employ a Monte Carlo trajectory-based algorithm for simulating the Lindblad dynamics for full ab initio Hamiltonians, demonstrating its effectiveness on molecular systems amenable to exact wavefunction treatment.

Quantum chemistry↗

Machine Learning for Automated Metadata Assignment in Buildings: Cooperative Research and Development (Final Report, CRADA Number CRD-18-00767)

RealTerm Energy and NREL have identified a shared vision to evaluate opportunities to facilitate the organization and assignment of metadata to building control system (BCS) data via industry-informed machine learning (ML). Manual metadata assignment is labor intensive and costly, slowing down any Energy Management and Information System (EMIS) deployment in the building space. This project aims to develop methodologies to accurately assign this metadata and significantly decrease the level of effort associated with deploying EMIS. The objective of this project is to identify/design methodologies to assign metadata to HVAC control points automatically. The identified methodologies will be programmed in analytics algorithms so they can ingest a list of points and produce a detailed tagging following the Haystack classification nomenclature. To validate the efficacy of each methodology, tagging results will be compared utilizing a list of points extracted from RealTerm's building database-as well as data extracted from the NREL campus via the Intelligent Campus program-enabling testing against large datasets with real world challenges. The developed methodologies may leverage building manager/operator input on a limited basis to add context to the classifying algorithms. The partnership aims to advance global efforts in areas related to the DOE missions through improving operational performance of commercial buildings. It is well documented that buildings fall out of commission after they are occupied, wasting significant energy and incurring associated costs simply due to poor operational performance. Emerging EMIS technologies that perform continuous commissioning help to address this issue, yet integration of these systems can be labor intensive both for the technology vendor and the building owner/operator. This project will enable more efficient and cost-effective analytics for buildings, enabling improvement in building operations at lower cost points.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Metaplectic geometrical optics for ray-based modeling of caustics: Theory and algorithms

The optimization of radio frequency-wave (RF) systems for fusion experiments is often performed using ray-tracing codes, which rely on the geometrical-optics (GO) approximation. However, GO fails at caustics such as cutoffs and focal points, erroneously predicting the wave intensity to be infinite. This is a critical shortcoming of GO, since the caustic wave intensity is often the quantity of interest, e.g., RF heating. Full-wave modeling can be used instead, but the computational cost limits the speed at which such optimizations can be performed. Here, we have developed a less expensive alternative called metaplectic geometrical optics (MGO). Instead of evolving waves in the usual x (coordinate) or k (spectral) representation, MGO uses a mixed X$\equiv$Ax+Bk representation. By continuously adjusting the matrix coefficients A and B along the rays, one can ensure that GO remains valid in the X coordinates without caustic singularities. The caustic-free result is then mapped back onto the original x space using metaplectic transforms. Here, we overview the MGO theory and review algorithms that will aid the development of an MGO-based ray-tracing code. We show how using orthosymplectic transformations leads to considerable simplifications compared to previously published MGO formulas. We also prove explicitly that MGO exactly reproduces standard GO when evaluated far from caustics (an important property that until now has only been inferred from numerical simulations), and we relate MGO to other semiclassical caustic-removal schemes published in the literature. Finally this discussion is then augmented by an explicit comparison of the computed spectrum for a wave bounded between two cutoffs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral beam prompt loss in LTX-β

Prompt loss of beam injected fast ions approaches 100% in lithium tokamak experiment-beta (LTX-β) discharges, though significantly improved confinement is expected for the higher current plasmas made available by a recent upgrade to the Ohmic heating power supply. Modeling of fast ions using TRANSP/NUBEAM finds a maximum coupled beam fraction of 76% at the near-term limits of the LTX-β operating space. The full ion orbit code POET is employed to validate NUBEAM results against possible non-adiabatic effects on fast ion orbits, but corrections to the prompt loss fraction due to collisionless transport are found to be small. The graphical method code CONBEAM is used to investigate the topology of fast ion phase space as it relates to neutral beam deposition, and counter-injected NBI is considered as a way to access a region of high field side beam deposition. A metric is developed within the CONBEAM using a beam filament model to estimate the prompt loss fraction and shown to agree well with both POET and NUBEAM, enabling near real-time analysis and potential feedback to operators between plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dark Energy Survey Year 6 results: Galaxy-galaxy lensing

Here, we present galaxy-galaxy lensing measurements from the full six years of data from the Dark Energy Survey (DES Y6), covering 4031 deg 2 and used in the DES Y6 3×2 pt cosmological analysis. We use the Maglim++ lens sample, containing ∼9 million galaxies divided into six redshift bins, and the Metadetection source catalog, including ∼140 million galaxies divided into four redshift bins. The mean tangential shear signal achieves a total signal-to-noise ratio (S/N) of 173, corresponding to a 17% improvement over DES Y3. After applying the scale cuts used in the cosmological analysis, with 𝑅 min =6 Mpc/ℎ (4 Mpc/ℎ) for the linear (nonlinear) galaxy-bias model, the S/N is reduced to 75 (90). A comprehensive suite of validation tests demonstrates that the measurement is robust against observational and astrophysical systematics at the statistical precision required for the DES Y6 analysis. Although not used in the main cosmological analysis, we extract high signal-to-noise geometric shear-ratio measurements from the galaxy-galaxy lensing signal on small angular scales. These measurements provide an internal consistency check on the photometric redshift distributions and shear calibration used in the 3 ×2 pt analysis.

cosmological parameters↗