Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space water systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

A dehydrated space-weathered skin cloaking the hydrated interior of Ryugu

Abstract Without a protective atmosphere, space-exposed surfaces of airless Solar System bodies gradually experience an alteration in composition, structure and optical properties through a collective process called space weathering. The return of samples from near-Earth asteroid (162173) Ryugu by Hayabusa2 provides the first opportunity for laboratory study of space-weathering signatures on the most abundant type of inner solar system body: a C-type asteroid, composed of materials largely unchanged since the formation of the Solar System. Weathered Ryugu grains show areas of surface amorphization and partial melting of phyllosilicates, in which reduction from Fe 3+ to Fe 2+ and dehydration developed. Space weathering probably contributed to dehydration by dehydroxylation of Ryugu surface phyllosilicates that had already lost interlayer water molecules and to weakening of the 2.7 µm hydroxyl (–OH) band in reflectance spectra. For C-type asteroids in general, this indicates that a weak 2.7 µm band can signify space-weathering-induced surface dehydration, rather than bulk volatile loss.

Astronomy & Astrophysics↗

Information Content of a Synergy of Ground-Based and Space-Based Infrared Sounders. Part I: Clear-Sky Environments

Abstract Profiles of atmospheric temperature and water vapor from remotely sensed platforms provide critical observations within the temporal and spatial gaps of the radiosonde network. The 2017 National Academies of Science Decadal Survey highlighted that observations of the planetary boundary layer (PBL) from the current space-based observing system are not of the necessary accuracy or resolution for monitoring and predicting high-impact weather phenomena. One possible solution to improving observations of the PBL is supplementing the existing space-based observing system with a network of ground-based profilers. A synthetic information content study is developed utilizing profiles from the Atmospheric Radiation Measurement (ARM) program sites at the Southern Great Plains (SGP), east North Atlantic (ENA), and North Slope of Alaska (NSA) to assess the benefits, in terms of degrees of freedom (DOF), vertical resolution, and uncertainties, of a synergy between the ground-based Atmospheric Emitted Radiance Interferometer (AERI) with space-based hyperspectral infrared (IR) sounders. A combination of AERI with any of the three polar-orbiting IR sounders: the Atmospheric Infrared Sounder (AIRS), the Cross-track Infrared Sounder (CrIS), or the Infrared Atmospheric Sounding Interferometer (IASI), results in a DOF increase of 30%–40% in the surface-to-700-hPa layer compared to the space-based instrument alone. Introducing AERI measurements to the observing system also results in significant improvements to vertical resolution and uncertainties in the bottom 1000 m of the atmosphere compared to CrIS measurements alone. A synergy of CrIS and AERI exceeds the 1-km-vertical-resolution goal set by the Decadal Survey in the lowest 1000 m.

54 ENVIRONMENTAL SCIENCES↗

Optimizing cost-effective and benchmarked industry standards to quantify nutrient bioextraction by seaweed

Interest in the utility of seaweed farms to mitigate coastal eutrophication, or nutrient loading, has grown commensurate with the recent rise of the farmed seaweed industry in the U.S. But economic valuation of this ecosystem service remains elusive in part because of challenges in quantifying this spatiotemporally variable biological process with reproducible and comparable metrics. Regulatory bodies that permit wastewater discharge or lease area for aquaculture farms require water quality testing and reporting of dissolved total nitrogen (N) in nearshore marine environments. These metrics must meet EPA standards for testing and reporting (e.g., Total Kjeldahl Nitrogen - TKN). However, these metrics are inherently highly variable over space and time in dynamic nearshore systems, and expensive to evaluate with sufficient breadth to constrain this variance, creating a critical bottleneck to direct quantification of farmed seaweed net uptake rates in situ.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated parameter and process learning for hydrologic and biogeochemical modules in Earth System Models

Focus area: Primary focal area #2; secondary focal area #3: Learning about parameters and processes of land surface hydrologic and biogeochemical models in Earth System models by integrating machine learning, physics, and big data. Science challenges: How do we maximally leverage big-data observations to improve hydrobiogeochemical process description and parameterization so that such modules more realistically capture hydrologic and vegetation responses and feedbacks under the future climate? For example, how can we leverage physics, limited observations of vegetation and streamflow to better estimate evapotranspiration, and, relatedly, net primary productivity, especially for drought areas? Vegetation plays a critical role in regional and global water cycles; however, existing vegetation models have failed to predict vegetation response to droughts (McDowell & Xu, 2017) , arctic greening (Keenan & Riley, 2018) , and critical transitions between forest and savanna (Hirota et al., 2011) . These studies suggest that when we build process-based models (PBM) parameterized from regional and global plant traits, we tend to poorly describe plant adaptation and local-scale competition processes. The models and their associated parameters assigned for different regions in the world are not capturing essential heterogeneity in vegetation responses at finer spatial scales. Many parameters of the land surface models control hydrology and vegetation dynamics at the same time. The heterogeneity in vegetation response is a function of (i) plant type, (ii) plant size, (iii) competition and succession, (iv) environmental controls, and (v) local variations due to the unique ecological community that are very difficult to describe (e.g., the size of gaps resulting from fire that facilitated the coexistence of pioneering species). In the demographic models, only factors (i) and (iv) were captured, and plant types were generally described only by leaf phenology and climate zones. With current demographic models, we generally consider more traits to define plant types (i) and calibrate these traits to consider factors (ii), (iii) and (iv); however, it is substantially challenging to scale to regional and global simulations due to trait variations across space (Ali et al., 2016). Moreover, it has been noted that hillslope processes, including ridge-to-valley flow and sunny vs. shady slopes are primary organizers of water, energy, and vegetation (Clark et al., 2015; Fan et al., 2019) . Although gradual improvements in the hydrologic model component in earth system models may reduce this error (at a remarkably slow pace), the long-term, gradual impact of hydrology on plant traits are not well captured. Recent work showed that the hydrologic controls exerted by groundwater and lateral flow are primary regulators of rooting depth (Fan et al., 2017) . Such hydrologic controls have seldom been reflected in vegetation model parameterizations.

54 ENVIRONMENTAL SCIENCES↗

Temperature Effect on Photoelectrochemical Water Splitting: A Model Study Based on BiVO 4 Photoanodes

Photoelectrochemical (PEC) water splitting is typically studied at room temperature. In this work, the temperature effect on PEC water splitting is studied using crystalline BiVO4 thin film photoanode as a model system. Systematic temperature-dependent electrochemical study demonstrates that the PEC activity is boosted at elevated electrolyte temperatures and indicates that thermal energy plays a main role in improving charge carrier transport in the bulk of BiVO 4 . Irreversible surface reconstruction is observed after PEC reactions at elevated temperature in the presence of hole scavengers, with regularly spaced stripes emerging on BiVO4 grains. The surface-reconstructed photoanode exhibits up to 40% improvement in photocurrent densities and ~0.25 V shift of photocurrent onset to favorable direction. Detailed investigation shows the formation of amorphous layer without stoichiometric change at the reconstructed surface. Furthermore, this work provides insights of temperature effect on photoelectrode in solar water splitting and reveals the non-negligible effect of hole scavengers in photoelectrochemical measurement.

36 MATERIALS SCIENCE↗

Energetics of water expulsion from intervening space between two particles during aggregation

Solvent expulsion away from an intervening region between two approaching particles plays important roles in particle aggregation yet remains poorly understood. Here, in this work, we use metadynamics molecular simulations to study the free energy landscape of removing water molecules from gibbsite and pyrophyllite slit pores representing the confined spaces between two approaching particles. For gibbsite, removing water from the intervening region is both entropically and enthalpically unfavorable. The closer the particles approach each other, the harder it is to expel water molecules. For pyrophyllite, water expulsion is spontaneous, which is different from the gibbsite system. A smaller pore makes the water removal more favorable. When water is being drained from the intervening region, single chains of water molecules are observed in gibbsite pore, while in pyrophyllite pore water cluster is usually observed. Water-gibbsite hydrogen bonds help stabilize water chains, while water forms clusters in pyrophyllite pore to maximize the number of hydrogen bonds among themselves. This work provides the first assessment into the energetics and structure of water being drained from the intervening region between two approaching particles during oriented attachment and aggregation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydration structure and energetics of iron-exchanged montmorillonite

The interaction between iron released from corroded steel canisters and bentonite is a key process influencing the long-term performance of nuclear waste repositories. In particular, the migration of Fe²⁺ into montmorillonite (Mnt) interlayers may alter its hydration, swelling, and ion-transport properties. In the present study, molecular dynamics simulations were performed to investigate the hydration behavior, structural response, and transport properties of Fe-exchanged montmorillonite (Fe-Mnt) under varying hydration states. The simulations focus on short- to intermediate-time-scale Fe 2+ and Fe 3+ interlayer exchange and hydration effects, and do not consider long-term structural substitution, Fe-bearing clay phase stabilization, or secondary iron mineral precipitation. Systems containing Na + -, Fe 2+ -, and Fe 3+ -Mnt were examined using both periodic and edge-exposed configurations to evaluate interlayer structure, ion exchange, and free energy of Fe intercalation. The results show that Fe ions influence the interlayer spacing primarily at low water contents (<1 bilayer), where Fe-Mnt exhibits a d-spacing 1–2 Å larger than Na-Mnt due to stronger hydration. The calculated hydration energies follow the order Fe 2+ $<$Fe 3+ $<$Na + . Both water and ion diffusion coefficients decrease upon Fe ion intercalation, with Fe 2+ ions diffusing an order of magnitude more slowly than those of Na + . Free energy profiles further confirm that Fe 2+ and Fe 3+ ions are thermodynamically favored in the interlayer, with Fe 3+ being the most stable. In conclusion, these findings provide molecular-scale insights into the mechanisms of Fe–Na exchange and their implications for bentonite alteration in repository environments.

clay↗

Mesoscale Convective Systems in a Superparameterized E3SM Simulation at High Resolution

Accurately representing mesoscale convective systems (MCSs) is crucial to simulating the energy and water cycles in global climate models. Using a novel MCS identification and tracking algorithm applied to observations and model simulations, we evaluate how well the Energy Exascale Earth System Model simulates MCSs over the central US. Simulations performed by E3SM at 25 km grid spacing with (SP-E3SM) and without (E3SM) superparameterization are compared and evaluated against observations using multiple metrics highlighting important MCS characteristics. Compared to E3SM, SP-E3SM better simulates MCS number and MCS precipitation amount, diurnal cycle, propagation, and the probability distribution of precipitation rate in both spring and summer. The improvement from SP is partly contributed by improvement in simulating the large-scale environments, featuring enhanced atmospheric low-level moisture and larger moisture transport to the central US relative to E3SM. However, SP-E3SM still underestimates MCS precipitation amount, particularly in summer. This underestimation is closely related to the negative bias in MCS precipitation intensity, although the drier environments simulated during summer also contributes to underestimation of MCS frequency. Without SP, the larger bias in MCS precipitation amount is closely related to the negative bias in MCS frequency, while the substantial dry bias in the large-scale environments also contributes to underestimation of MCS intensity. Our results suggest that SP improves MCS simulation by improving modeling of the large-scale environments and convection initiation, which are both major limiting factors in E3SM even at 25 km grid spacing where deep convection is represented by a cumulus parameterization.

54 ENVIRONMENTAL SCIENCES↗

Computational Study of Hydraulic Performance of South Carolina DOT Catch Basins Type CB 1, CB 16, and CB 17

Proper design of surface drainage of roadways is essential to minimize flooding and provide for traffic safety. Inlets collect the excess storm water from the drainage area of a roadway and discharge it to storm drains. Knowing the hydraulic efficiency of inlets, defined as the percentage of intercepted flow to the total street flow, is necessary in drainage design to determine inlet spacing such that the system can transport all or the majority of the road surface flow during rain events off of the road into the catch basins.

42 ENGINEERING↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Modeling Geologic Waste Repository Systems Below Residual Saturation

The heat generated by high-level radioactive waste can pose numerical and physical challenges to subsurface flow and transport simulators if the liquid water content in a region near the waste package approaches residual saturation due to evaporation. Here, residual saturation is the fraction of the pore space occupied by liquid water when the hydraulic connectivity through a porous medium is lost, preventing the flow of liquid water. While conventional capillary pressure models represent residual saturation using asymptotically large values of capillary pressure, here, residual saturation is effectively modeled as a tortuosity effect alone. Treating the residual fluid as primarily dead-end pores and adsorbed films, relative permeability is independent of capillary pressure below residual saturation. To test this approach, PFLOTRAN is then used to simulate thermal-hydrological conditions resulting from direct disposal of a dual-purpose canister in unsaturated alluvium using both conventional asymptotic and revised, smooth models. Importantly, while the two models have comparable results over 100 000 years, the number of flow steps required is reduced by approximately 94%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Enhanced Laplace Pressures for Functional Surfaces: Wicking, Switchability, and Selectivity

Abstract Wetting functionalities of rough surfaces are largely determined by the Laplace pressure generated across liquid–gas interfaces formed within surface structures. Typically, rough wetting surfaces create negative Laplace pressures, enabling capillary wicking, while rough non‐wetting surfaces create positive Laplace pressures, exhibiting fluid repellency. Here, with microfabricated reentrant structures, it is shown that the same surface can exhibit either a negative or positive Laplace pressure, regardless of its intrinsic wettability. This material‐independent Laplace pressure duality enables or enhances a range of wetting functionalities including wicking, switchability, and selectivity. On the same surface, capillary rise, capillary dip, and the combination of the two which leads to further enhancement of the total sustainable capillary height and Laplace pressure, the driving force for wicking is demonstrated. Further, active switching of wetting states between the hemiwicking and the repellent Cassie state on reentrant structures is shown. Moreover, with a water‐hexane mixture system, selective wetting of reentrant structures are demonstrated, that is, water can be selectively wicked or repelled in the presence of hexane, and vice versa. These functionalities are achieved, which would typically require complex chemical coatings, solely using surface structures, thus largely expanding the design space for a wide range of thermofluidic applications.

36 MATERIALS SCIENCE↗

A multi-dimensional parametric study of variability in multi-phase flow dynamics during geologic CO 2 sequestration accelerated with machine learning

Successful geologic CO 2 storage projects depend on numerical simulations to predict reservoir performance during site selection, injection verification, and post-injection monitoring phases of the project. These numerical simulations solve non-linear sets of coupled partial differential equations, while accounting for multi-phase fluid dynamics on the basis of constitutive equations that are embedded into the solution scheme. As a consequence, individual simulations often require tens to hundreds of hours to complete on high-performance computing clusters. Moreover, laboratory experiments reveal that parametric functions for capillary pressure and relative permeability exhibit substantial variability, even within the same rock type. This combination of computational expense and wide-ranging parametric variability means that there remains substantial uncertainty in the behavior of multi-phase CO 2 -water systems, particularly in the context of feedbacks between relative permeability and capillary pressure. To bridge this knowledge gap, here we develop a novel workflow that utilizes physics-based numerical simulation to train an artificial neural network (ANN) emulator for interrogating the multivariate parameter space that governs both capillary pressure and relative permeability. With this approach, the ANN is trained to emulate both fluid pressure distribution and CO 2 saturation, which are then interrogated quantitatively to generate parametric response surface mappings with high-fidelity resolution. Results from this study initially show that capillary entry pressure is the dominant control on both CO 2 plume geometry and fluid pressure propagation when considering the combined effects of capillary pressure and relative permeability, particularly when phase interference is low and residual CO 2 saturation is high. Moreover, the ANN emulator provides tremendous computational speed-up by computing 2691 individual simulations in several minutes; whereas, the same simulation ensemble would have required ~3 years of simulation time using only physics-based simulation methods (25,000 times speed up).

58 GEOSCIENCES↗

Semi-automated Design of Artificial Intelligence Earth Science Models

Prediction and observation of water cycles involve not only patterns isolated in space and time, but rather modeling complex spatio-temporal relationships across multiple sources of data and domains. For instance, Evapotranspiration (ET) and Leaf Area Indexes (LAI) are two critical components in DOE’s Energy Exascale Earth System Model (E3SM). Accurate assessments of ET and LAI are critical for understanding hydrological processes, deforestation, crop yield, and irrigation impacts. However, current ET estimates for global simulations are available at very coarse spatial resolution. They are usually derived from satellite data based on broad plant functional types (PFT), which fail to capture the fine-scale variations due to change in vegetation type across the globe. Within this context and in light of the data-model integration challenges highlighted in the EESSD Strategic Plan, the new era of AI model development for geosciences calls for data-driven methods that provide domain scientists with estimations of parameters such as PFT and LAI in an efficient, interpretable, and easy-to-operate manner.

Ambrozio Dias, Philipe↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Titanium Carbide MXene Shows an Electrochemical Anomaly in Water-in-Salt Electrolytes

Identifying and understanding charge storage mechanisms is important for advancing energy storage. Well-separated peaks in cyclic voltammograms (CVs) are considered key indicators of diffusion-controlled electrochemical processes with distinct Faradaic charge transfer. Herein, we report on an electrochemical system with separated CV peaks, accompanied by surface-controlled partial charge transfer, in 2D Ti 3 C 2 T x MXene in water-in-salt electrolytes. The process involves the insertion/desertion of desolvation-free cations, leading to an abrupt change of the interlayer spacing between MXene sheets. This unusual behavior increases charge storage at positive potentials, thereby increasing the amount of energy stored. This also demonstrates opportunities for the development of high-rate aqueous energy storage devices and electrochemical actuators using safe and inexpensive aqueous electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗