Earth Radiation Budget Experiment instrument design status

The design configuration of Earth Radiation Budget Experiment (ERBE) instruments are presented. The ERBE scanners and nonscanners are discussed in terms of hardware and optical development, operational parameters, and calibration plans for ground and flight systems. The various instrument designs are given and described in detail. It is emphasized that the design goal is to approach state-of-the-art laboratory radiometric accuracies with spaceflight qualified hardware in an earth orbit environment with a projected operational lifetime of over two years. Accurate inputs to models of weather and climate are expected which will allow a better understanding of radiation transfer and the energy balance of the earth.

Kopia, L. P.

A Triboelectric Sensor Array for Electrostatic Studies on the Lunar Surface

The moons electrostatic environment requires careful consideration in the development of future lunar landers. Electrostatically charged dust was well documented during the Apollo missions to cause thermal control, mechanical, and visibility issues. The fine dust particles that make up the surface are electrostatically charged as a result of numerous charging mechanisms. The relatively dry conditions on the moon creates a prime tribocharging environment during surface operations. The photoelectric effect is dominant for lunar day static charging, while plasma electrons are the main contributor for lunar night electrostatic effects. Electrostatic charging is also dependent on solar intensity, Earth-moon relative positions, and cosmic ray flux. This leads to a very complex and dynamic electrostatic environment that must be studied for the success of long term lunar missions.In order to better understand the electrostatic environment of planetary bodies, Kennedy Space Center, in previous collaboration with the Jet Propulsion Laboratory, has developed an electrostatic sensor suite. One of the instruments included in this package is the triboelectric sensor array. It is comprised of strategically selected materials that span the triboelectric series and that also have previous spaceflight history. In this presentation, we discuss detailed testing with the triboelectric sensor array performed at Kennedy Space Center. We will discuss potential benefits and use cases of this low mass, low cost sensor package, both for science and for mission success.

Charging

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system has been guided by our under-standing of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure, and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-excesses of chiral amino acids or sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. However, studies of primitive meteorites have revealed that they contain extraterrestrial amino acids and sugar acids with large enantiomeric excesses (60% and higher) that resulted from non-biological processes [1], complicating the use of chiral asymmetry by itself as a definitive biosignature. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, is an objective of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks by the Sample Analysis at Mars (SAM) instrument suite on Mars [2-5], NASA’s Curiosity rover has found evidence of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars [5], indigenous achiral amino acids have been identified in one martian meteorite [6]. It is expected that amino acid racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [7]. The ESA/Roscosmos ExoMars mission scheduled for launch next year includes the Rosalind Franklin rover designed to acquire samples from a depth of ~2 m and deliver them to a suite of instruments, including the Mars Organic Molecule Analyzer (MOMA). The MOMA instrument contains a wet chemistry experiment designed specifically for the detection of amino acids and measurement of their enantiomeric compositions [8]. The complexity and limited duration of spaceflight operations, and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic com-pounds in ancient rocks, make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, bulk and molecule-specific isotopic, and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars derives from bio-tic or abiotic processes. Ultimately, Mars Sample Return of rock cores collected by NASA’s Perseverance rover may be our best chance of identifying chemical biosignatures, including any chiral amino acid asymmetry resulting from a past or present martian biota, if one ever existed on Mars. Here we review our current knowledge of the distributions, and enantiomeric and isotopic com-positions of amino acids found in meteorites compared to terrestrial biochemistry. We also propose a set of measurement criteria that should be used to help establish the sources of any amino acids detected in samples returned from Mars using state-of-the-art gas and liquid chromatography mass spectrometry techniques [1].

D P Glavin

Designing for Reliability and Robustness

Long duration spaceflight has a negative effect on the human body, and exercise countermeasures are used on-board the International Space Station (ISS) to minimize bone and muscle loss, combatting these effects. Given the importance of these hardware systems to the health of the crew, this equipment must continue to be readily available. Designing spaceflight exercise hardware to meet high reliability and availability standards has proven to be challenging throughout the time the crewmembers have been living on ISS beginning in 2000. Furthermore, restoring operational capability after a failure is clearly time-critical, but can be problematic given the challenges of troubleshooting the problem from 220 miles away. Several best-practices have been leveraged in seeking to maximize availability of these exercise systems, including designing for robustness, implementing diagnostic instrumentation, relying on user feedback, and providing ample maintenance and sparing. These factors have enhanced the reliability of hardware systems, and therefore have contributed to keeping the crewmembers healthy upon return to Earth. This paper will review the failure history for three spaceflight exercise countermeasure systems identifying lessons learned that can help improve future systems. Specifically, the Treadmill with Vibration Isolation and Stabilization System (TVIS), Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), and the Advanced Resistive Exercise Device (ARED) will be reviewed, analyzed, and conclusions identified so as to provide guidance for improving future exercise hardware designs. These lessons learned, paired with thorough testing, offer a path towards reduced system down-time.

Svetlik, Randall G.

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record

Carbon Nanotubes on Titanium Substrates for Stray Light Suppression

A method has been developed for growing carbon nanotubes on a titanium substrate, which makes the nano tubes ten times blacker than the current state-of-the-art paints in the visible to near infrared. This will allow for significant improvement of stray light performance in scientific instruments, or any other optical system. Because baffles, stops, and tubes used in scientific observations often undergo loads such as vibration, it is critical to develop this surface treatment on structural materials. This innovation optimizes the carbon nano - tube growth for titanium, which is a strong, lightweight structural material suitable for spaceflight use. The steps required to grow the nanotubes require the preparation of the surface by lapping, and the deposition of an iron catalyst over an alumina stiction layer by e-beam evaporation. In operation, the stray light controls are fabricated, and nanotubes (multi-walled 100 microns in length) are grown on the surface. They are then installed in the instruments or other optical devices.

Hagopian, John

Compact spaceflight solution crystal-growth system

A versatile, miniaturized, stand alone, crystal solution growth chamber design is presented which is based on fiber optics, diode lasers, and holographic optical elements in conjunction with knowledge gained from previous Spacelab work. Diagnostics instrumentation is based on a crystal growth monitor, a growth/dissolution monitor with feedback, solution diagnostics, multiple wavelength holography, and single wavelength or color Schlieren with video recording.

Trolinger, James D.

50 Years of Spaceflight with Fourier Transform Spectrometers (FTS) Built at NASA GSFC

Over the past 50 years, NASA Goddard Space Flight Center (GSFC) has been developing, building, testing and flying a series of Fourier Transform Spectrometers (FTS). This began with the IRIS instruments on the Earth-orbiting Nimbus satellites and progressed to more sophisticated designs optimized for interplanetary spacecraft sent to Mars and later to the outer solar system. Adaptions have been made over time, including progressively higher spectral resolution, sensitivity, numbers of detectors and complexity. Instrument operating temperatures have decreased to enable remote sensing of the cold giant planet systems. In this paper we describe the historical evolution of this instrument line, comparing and contrasting different aspects such as optical design and materials, detector types and data handling. We conclude by looking towards the future. At present the CIRS-Lite prototype is being tested at NASA GSFC for potential use on a future mission to the ice giants, Uranus and Neptune. Surpassing the previous performance of the Voyager IRIS instruments remains challenging, and new technologies that could enable these measurements are discussed.

Nixon, Conor A.

Improved Whole-Blood-Staining Device

Dramatic improvements have been made in NASA s Whole Blood Staining Device (WBSD) since it was last described in "Whole-Blood-Staining Device," NASA Tech Briefs, Vol. 23, No. 10 (October 1999), page 64. The new system has a longer shelf life, a simpler and more effective operational procedure, improved interface with instrumentation, and shorter processing time. More specifically, the improvements have targeted bag and locking clip materials, sampling ports, and air pocket prevention. The WBSD stains whole blood collected during spaceflight for subsequent flow cytometric analysis. In short, the main device stains white blood cells by use of monoclonal antibodies conjugated to various fluorochromes, followed by lysing and fixing of the cells by use of a commercial reagent that has been diluted according to NASA safety standards. This system is compact, robust, and does not require electric power, precise mixing, or precise incubation times. Figure 1 depicts the present improved version for staining applications, which is a poly(tetrafluoroethylene) bag with a Luer-lock port and plastic locking clips. An InterLink (or equivalent) intravenous- injection port screws into the Luer-lock port. The inflatable/collapsible nature of the bag facilitates loading and helps to minimize the amount of air trapped in the fully loaded bag. Some additional uses have been identified for the device beyond whole blood staining. The WBSD has been configured for functional assays that require culture of live cells by housing sterile culture media, mitogens, and fixatives prior to use [Figure 2(a)]. Simple injection of whole blood allows cell-stimulation culture to be performed in reduced gravity conditions, and product stabilization prior to storage, while protecting astronauts from liquid biohazardous materials. Also, the improved WBSD has reconstituted powdered injectable antibiotics by mixing them with diluent liquids [Figure 2(b)]. Although such mixing can readily be performed on Earth by shaking in glass vials, it cannot readily be performed this way in outer space without entraining air bubbles. The present device can be preloaded with the powder and diluent(s) in separate compartments. The powder and diluent( s) can be mixed, without introducing air bubbles, by removing the clip(s), then shaking. This use of the device could also be advantageous in terrestrial applications because it maintains the isolation of the constituents until the time of use.

Sams, Clarence F.

A New Large Vibration Test Facility Concept for the James Webb Space Telescope

The James Webb Space Telescope consists of three main components, the Integrated Science Instrument Module (ISIM) Element, the Optical Telescope Element (OTE), and the Spacecraft Element. The ISIM and OTE are being assembled at the National Aeronautics and Space Administration's Goddard Spaceflight Center (GSFC). The combined OTE and ISIM Elements, called OTIS, will undergo sine vibration testing before leaving Goddard. OTIS is the largest payload ever tested at Goddard and the existing GSFC vibration facilities are incapable of performing a sine vibration test of the OTIS payload. As a result, a new large vibration test facility is being designed. The new facility will consist of a vertical system with a guided head expander and a horizontal system with a hydrostatic slip table. The project is currently in the final design phase with installation to begin in early 2015 and the facility is expected to be operational by late 2015. This paper will describe the unique requirements for a new large vibration test facility and present the selected final design concepts.

test facilities

A New Large Vibration Test Facility Concept for the James Webb Space Telescope

The James Webb Space Telescope consists of three main components, the Integrated Science Instrument Module (ISIM) Element, the Optical Telescope Element (OTE), and the Spacecraft Element. The ISIM and OTE are being assembled at the National Aeronautics and Space Administration's Goddard Spaceflight Center (GSFC). The combined OTE and ISIM Elements, called OTIS, will undergo sine vibration testing before leaving Goddard. OTIS is the largest payload ever tested at Goddard and the existing GSFC vibration facilities are incapable of performing a sine vibration test of the OTIS payload. As a result, a new large vibration test facility is being designed. The new facility will consist of a vertical system with a guided head expander and a horizontal system with a hydrostatic slip table. The project is currently in the final design phase with installation to begin in early 2015 and the facility is expected to be operational by late 2015. This paper will describe the unique requirements for a new large vibration test facility and present the selected final design concepts.

vibration

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph

IceCube: CubeSat 883-GHz Radiometry for Future Ice Cloud Remote Sensing

Ice clouds play a key role in the Earth's radiation budget, mostly through their strong regulation of infrared radiation exchange. Accurate observations of global cloud ice and its distribution have been a challenge from space, and require good instrument sensitivities to both cloud mass and microphysical properties. Despite great advances from recent spaceborne radar and passive sensors, uncertainty of current ice water path (IWP) measurements is still not better than a factor of 2. Submillimeter (submm) wave remote sensing offers great potential for improving cloud ice measurements, with simultaneous retrievals of cloud ice and its microphysical properties. The IceCube project is to enable this cloud ice remote sensing capability in future missions, by raising 874-GHz receiver technology TRL from 5 to 7 in a spaceflight demonstration on 3-U CubeSat in a low Earth orbit (LEO) environment. The NASAs Goddard Space Flight Center (GSFC) is partnering with Virginia Diodes Inc (VDI) on the 874-GHz receiver through its Vector Network Analyzer (VNA) extender module product line, to develop an instrument with precision of 0.2 K over 1-second integration and accuracy of 2.0 K or better. IceCube is scheduled to launch to and subsequent release from the International Space Station (ISS) in mid-2016 for nominal operation of 28 plus days. We will present the updated design of the payload and spacecraft systems, as well as the operation concept. We will also show the simulated 874-GHz radiances from the ISS orbits and cloud scattering signals as expected for the IceCube cloud radiometer.

cloud ice remote sensing

Background suppression techniques in germanium detectors

A new generation of astrophysical gamma ray spectrometers employing germanium solid state detectors for precise energy measurement are currently being planned for spaceflight in the late 1990's and the early 21st century. Because the observations of weak celestial sources are carried out in an intense radiation environment, the key objective of instrument design is to find ways to reduce the background. The current state of the knowledge in this field is reviewed and the new hardware techniques under design and test are discussed. Many of these techniques have already been flight tested on balloon platforms. Recent results from some of these tests are presented. By carefully applying these techniques it should be possible to achieve sensitivities that are factors of 3 to 10 better than would be obtained for a conventional instrument of similar weight.

Gehrels, Neil

Structural-Thermal-Optical-Performance (STOP) Analysis

The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). A STOP analysis is a multidiscipline analysis, consisting of Structural, Thermal and Optical Performance Analyses, that is performed for all space flight instruments and satellites. This course will explain the different parts of performing this analysis. The student will learn how to effectively interact with each discipline in order to accurately obtain the system analysis results.

Optical

Body of Knowledge (BOK) for Copper Wire Bonds

Copper wire bonds have replaced gold wire bonds in the majority of commercial semiconductor devices for the latest technology nodes. Although economics has been the driving mechanism to lower semiconductor packaging costs for a savings of about 20% by replacing gold wire bonds with copper, copper also has materials property advantages over gold. When compared to gold, copper has approximately: 25% lower electrical resistivity, 30% higher thermal conductivity, 75% higher tensile strength and 45% higher modulus of elasticity. Copper wire bonds on aluminum bond pads are also more mechanically robust over time and elevated temperature due to the slower intermetallic formation rate - approximately 1/100th that of the gold to aluminum intermetallic formation rate. However, there are significant tradeoffs with copper wire bonding - copper has twice the hardness of gold which results in a narrower bonding manufacturing process window and requires that the semiconductor companies design more mechanically rigid bonding pads to prevent cratering to both the bond pad and underlying chip structure. Furthermore, copper is significantly more prone to corrosion issues. The semiconductor packaging industry has responded to this corrosion concern by creating a palladium coated copper bonding wire, which is more corrosion resistant than pure copper bonding wire. Also, the selection of the device molding compound is critical because use of environmentally friendly green compounds can result in internal CTE (Coefficient of Thermal Expansion) mismatches with the copper wire bonds that can eventually lead to device failures during thermal cycling. Despite the difficult problems associated with the changeover to copper bonding wire, there are billions of copper wire bonded devices delivered annually to customers. It is noteworthy that Texas Instruments announced in October of 2014 that they are shipping microcircuits containing copper wire bonds for safety critical automotive applications. An evaluation of copper wire bond technology for applicability to spaceflight hardware may be warranted along with concurrently compiling a comprehensive understanding of the failure mechanisms involved with copper wire bonded semiconductor devices.

Body of Knowledge (BOK)

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.