Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

NASA Ames Research Center Unitary Plan Wind Tunnel Fall 2018 Outage - Motor 1 Activity: Stator Shift

The Unitary Plan Wind Tunnel consists of the 11 x 11- Foot Transonic Wind Tunnel and the 9 x 7 foot Supersonic Wind Tunnel. The four 65,000hp electric motors that drive the wind tunnel compressors require periodic maintenance. In order to inspect the motors without the removal of drive shaft components, the stator must be shifted away from the motor. This process is referred to as "Stator Shift". Video is mp4 formatted with runtime of 2 mins 54 secs.

Wind Tunnel↗

Large Eddy Simulation of Externally Induced Ingress about an Axial Seal by Stator Vanes

Turbine inlet temperatures in advanced gas turbines could be as high as 2000 °C. To prevent ingress of this hot gas into the wheelspace between the stator and rotor disks, whose metals can only handle temperatures up to 850 °C, rim seals and sealing flows are used. This study examines the abilities of large eddy simulation (LES) based on the WALE subgrid model and Reynolds-averaged Navier–Stokes (RANS) based on the SST model in predicting ingress in a rotor–stator configuration with vanes but no blades, a configuration with experimental data for validation. Results were obtained for an operating condition, where the ratio of the external Reynolds number to the rotational Reynolds number is 0.538. At this operating condition, both LES and RANS were found to correctly predict the coefficient of pressure, C p , located downstream of the vanes and upstream of the seal, but only LES was able to correctly predict the sealing effectiveness. This shows C p by itself is inadequate in quantifying externally induced ingress. RANS was unable to predict the sealing effectiveness because it significantly under predicted the pressure drop in the hot gas path along the axial direction, especially about the seal region. This affected the pressure difference across the seal in the radial direction, which ultimately drives ingress.

42 ENGINEERING↗

Noise study of single stage compressor rotor-stator interaction

Study made of noise radiation from rotor-stator interaction in axial-flow compressors. The collected data were reduced to the form of radiation patterns and frequency spectra. These data show how the radiation patterns are affected by the relative number of rotor blades and stator vanes.

Copeland, W. L.↗

High-temperature electric stator

Thermal vacuum tests are conducted on high-temperature stator without a rotor. Electrical characteristics remained satisfactory during tests, insulation improved slightly, and conductor resistance remained constant. The assembly included a bore seal for hermetically sealing the stator from the rotor cavity.

Kueser, P.↗

Evaluation of range and distortion tolerance for high Mach number transonic fan stages. Task 2: Performance of a 1500-foot-per-second tip speed transonic fan stage with variable geometry inlet guide vanes and stator

A 0.5 hub/tip radius ratio compressor stage consisting of a 1500 ft/sec tip speed rotor, a variable camber inlet guide vane and a variable stagger stator was designed and tested with undistorted inlet flow, flow with tip radial distortion, and flow with 90 degrees, one-per-rev, circumferential distortion. At the design speed and design IGV and stator setting the design stage pressure ratio was achieved at a weight within 1% of the design flow. Analytical results on rotor tip shock structure, deviation angle and part-span shroud losses at different operating conditions are presented. The variable geometry blading enabled efficient operation with adequate stall margin at the design condition and at 70% speed. Closing the inlet guide vanes to 40 degrees changed the speed-versus-weight flow relationship along the stall line and thus provided the flexibility of operation at off-design conditions. Inlet flow distortion caused considerable losses in peak efficiency, efficiency on a constant throttle line through design pressure ratio at design speed, stall pressure ratio, and stall margin at the 0 degrees IGV setting and high rotative speeds. The use of the 40 degrees inlet guide vane setting enabled partial recovery of the stall margin over the standard constant throttle line.

Bilwakesh, K. R.↗

Highly loaded multi-stage fan drive turbine: Leaned stator configuration design

The results of the high lift blade configuration design study are reported. The three-stage constant-inside-diameter turbine utilizes a ten degree tangentially leaned stator in stage three. All other bladerows use plain blades. Analysis of the leaned stator is discussed, and detailed design data are summarized. Steady-state stresses are discussed, and the results of the mechanical design analysis are presented.

Evans, D. C.↗

Single-stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 3: Data and performance for stage C

Stage C, comprised of tandem-airfoil rotor C and tandem-airfoil stator B, was designed and tested to establish performance data for comparison with the performance of conventional single-airfoil blading. Velocity diagrams and blade leading and trailing edge metal angles selected for the conventional rotor and stator blading were used in the design of the tandem blading. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. At design equivalent rotor speed, rotor C achieved a maximum adiabatic efficiency of 91.8% at a pressure ratio of 1.31. The stage maximum adiabatic efficiency was 86.5% at a pressure ratio of 1.31.

Brent, J. A.↗

Methods for reducing blade passing frequency noise generated by rotor-wake - stator interaction

A theoretical model for the generation of blade-passage noise caused by the interaction of rotor wakes with the downstream stator blades in a fan stage has been compiled. This model has combined a description of the rotor wake based on existing experimental correlations with an existing theory for the response of the stator blades to those wakes. This model of the interaction-caused blade-passage noise has been used to examine some effects of blade geometry and flow conditions on the noise generated. A set of significant parameters has been identified to reduce this interaction-caused blade-passage frequency noise. A redesign of an existing fan with the use of these concepts has produced a theoretical noise reduction of more than 7 decibels.

Dittmar, J. H.↗

Analytical study on a two-dimensional plane of the off-design flow properties of tandem-bladed compressor stators

The flow characteristics of several tandem bladed compressor stators were analytically evaluated over a range of inlet incidence angles. The ratios of rear-segment to front-segment chord and camber were varied. Results were also compared to the analytical performance of a reference solid blade section. All tandem blade sections exhibited lower calculated losses than the solid stator. But no one geometric configuration exhibited clearly superior characteristics. The front segment accepts the major effect of overall incidence angle change. Rear- to front-segment camber ratios of 4 and greater appeared to be limited by boundary-layer separation from the pressure surface of the rear segment.

Sanger, N. L.↗

Single stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 4: Data and performance for stage B

Stage B, composed of tandem-airfoil rotor B and stator B, was tested with uniform inlet flow and with hub radial, tip radial and 90 degree one-per-revolution circumferential distortion of the inlet flow as part of an overall program to evaluate the effectiveness of tandem airfoils for increasing the design point loading capability and stable operating range of rotor and stator blading. The results of this series of tests provide overall performance and blade element data for evaluating: (1) the potential of tandem blading for extending the loading limit and stable operating range of a stage representative of a middle stage of an advanced high pressure compressor, (2) the effect of loading split between the two airfoils in tandem on the performance of tandem blading, and (3) the effects of inlet flow distortion on the stage performance. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. With uniform inlet flow, rotor B achieved a maximum adiabatic efficiency of 88.4% at design equivalent rotor speed and a pressure ratio of 1.31. The stage maximum adiabatic efficiency at design equivalent rotor speed with uniform inlet flow was 82.5% at a pressure ratio of 1.28. Tip radial and circumferential distortion of the inlet flow caused substantial reductions in surge margin.

Brent, J. A.↗

Effect of rotor-to-stator spacing on acoustic performance of a full-scale fan (QF-5) for turbofan engines

A study was made of the effect of increasing the fan rotor-to-stator spacing on the noise level of a full-scale, single-stage, 1.6-pressure-ratio fan. Noise data were obtained with axial spacing of 1.14, 1.65, and 2.27 rotor chord lengths. Over this spacing range, data indicate a reduction of 1.5 PNdb. Apparently, rotor-alone noise at the frequency at which the rotor-stator interaction noise was cut off limited the noise reduction for the QF-5 fan. It seems, however, that the reduction in sound power level with increases in spacing is potentially about 6 db over the range of spacing tested.

Balombin, J. R.↗

Cold air study of the effect on turbine stator blade aerodynamic performance of coolant ejection from various trailing edge slot geometries. 2: Comparison of experimental and analytical results

Experimentally determined efficiencies of turbine stator blades having trailing-edge coolant ejection are compared with efficiencies predicted from two previously published approximate analytical methods. The experimental results were obtained from two-dimensional data with the temperature of the primary and coolant flows both being nearly ambient. Data from five stator blade configurations having different slotted trailing-edge geometries were included in the comparison. The two analytical methods gave results which agreed reasonably well with experimental results. An average of the absolute values of differences between experimental and predicted efficiencies for all five blade configurations showed that one method gave average efficiency differences which were about 1.3 percent different than experimental efficiencies, while the other method gave average efficiency differences that were about 0.7 percent different than experimental. However, in some instances, maximum differences of as much as 4 percent occurred. A comparison between experimental and analytical results indicated that the ratio of trailing-edge slot width to trailing-edge thickness influences the measured efficiencies to a greater extent than is accounted for by either analytical model.

Prust, H. W., Jr.↗

Stalled and stall-free performance of axial-flow compressor stage with three inlet-guide-vane and stator-blade settings

The performance of the first stage of a transonic, multistage compressor was mapped over a range of inlet-guide-vane and stator-blade settings. Both stall-free and deep-stall performance data were obtained. For the settings tested, as stall was encountered and flow was further reduced, a relatively sharp drop in pressure ratio occurred and was followed by a continuing but more gradual reduction in pressure ratio with reduced flow. The position of the stall line on the map of pressure ratio against equivalent weight flow was essentially unaffected over the range of inlet-guide-vane and stator-blade settings.

Urasek, D. C.↗

NASA gas turbine stator vane ring

Four monolithic stator vane rings from reaction-bonded silicon nitride were produced. This paper describes the various steps involved: wax injection of stator vane patterns, precise fixturing of patterns, mold fabrication, slip preparation, casting, prenitriding, nitriding, and ceramic machining. Each process step is discussed and illustrated, and tables of property measurements are included.

Gersch, H. M.↗

Cold-air performance of a 15.41-cm-tip-diameter axial-flow power turbine with variable-area stator designed for a 75-kW automotive gas turbine engine

An experimental evaluation of the aerodynamic performance of the axial flow, variable area stator power turbine stage for the Department of Energy upgraded automotive gas turbine engine was conducted in cold air. The interstage transition duct, the variable area stator, the rotor, and the exit diffuser were included in the evaluation of the turbine stage. The measured total blading efficiency was 0.096 less than the design value of 0.85. Large radial gradients in flow conditions were found at the exit of the interstage duct that adversely affected power turbine performance. Although power turbine efficiency was less than design, the turbine operating line corresponding to the steady state road load power curve was within 0.02 of the maximum available stage efficiency at any given speed.

Mclallin, K. L.↗