Residential (Secondary-Use) Energy Storage System with Modular Software and Hardware Power Electronic Interfaces

Secondary-use energy storage systems (ESS) are a potential low-cost energy storage system for the electric grid. These systems propose a low-cost solution to the challenge, what to do with electric vehicle batteries once EV end-of-life has been reached. However, the development of an ESS is complex by nature. Typically, the bidirectional power electronics conversion (PEC) system has hardware which includes power stages, auxiliary circuits, protection circuits, and the control interfaces all embedded and integrated as a system. This leads to interoperability challenges and vendor dependencies that increase balance of system costs. This paper proposes a modular approach of software and hardware interfaces to reduce the costs of an ESS.

Starke, Michael↗

QoS-Enabled, High-performance Storage Systems for Data-Intensive Scientific Computing (Final Report)

This project's work resulted in the following research projects: (1) BORG - Block-reORGanization for Self-optimizing Storage Systems; (2) ABLE - Active Block Layer Extensions; (3) EXCES - EXternal Caching in Energy-Saving Storage Systems; and (4) GRIO - Guaranteed-Rate I/O Scheduler. These projects together help in substantially advancing the over-arching project goal of developing "QoS-Enabled, High-Performance Storage Systems".

99 GENERAL AND MISCELLANEOUS↗

Systems and Tools to Facilitate Aging Management Inspections of Used Nuclear Fuel Dry Storage Systems - 18382

The Used Nuclear Fuel (UNF) dry storage systems (DSSs) are currently used at almost all the nuclear plants in the USA for the storage of their UNF as the spent fuel pools are running out of capacity to store any additional discharged fuel. Even though these DSSs are supposed to be at the reactor site for a short amount of time, they are expected to be at the reactor sites for an extended duration due to the unavailability of Interim Storage Facilities (ISF) or a permanent disposal sites like Yucca Mountain. Maintaining the integrity of the DSS canisters and storage overpacks so they can safely protect the fuel and maintain the integrity of UNF is of utmost importance during storage at reactor site ISFSI or at the ISF. Comprehensive and robust Aging Management Program (AMP) is an important aspect for DSSs to satisfy these requirements. In order to address this industry need, TN Americas have developed an enhanced NUHOMS{sup R} DSS licensed by NRC under 10 CFR Part 72 regulations and a comprehensive AMP development which includes prevention, inspection, monitoring and mitigation of any corrosion or degradation of DSS components. For DSC and HSM inspection, two remotely operating delivery systems have been developed using non-destructive examination (NDE) methods including robotic crawler and inspection ring system. This paper describes details of these developments and status of their deployment for implementation at various utility ISFSI sites. TN Americas completed the detailed design of the DSC inspection system and conducted functional tests of the inspection system on a DSC mockup and the system is ready for deployment at any NUHOMS{sup R} ISFSI site. TN Americas is committed to offer the most robust and comprehensive AMP systems, tools and services to the industry to assure the safety of the deployed DSS at the utility sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Storage System Modeling: Public Access, Maintenance, and Enhancements

This presentation summarizes the Fiscal Year 2020 status and accomplishments for the Hydrogen Storage System Modeling project, a collaborative effort to manage, update, and enhance hydrogen storage system models developed under the Hydrogen Storage Engineering Center of Excellence (HSECoE). The project goal is to provide validated modeling tools that will be used by researchers to evaluate the performance of their new materials in engineered systems relative to the DOE technical targets.

AMR↗

The Power and Energy Storage Systems Toolbox–PSTess (V1.0)

This document describes the Power and Energy Storage Systems Toolbox for MATLAB, abbreviated as PSTess. This computing package is a fork of the Power Systems Toolbox (PST). PST was originally developed at Rensselaer Polytechnic Institute (RPI) and later upgraded by Dr. Graham Rogers at Cherry Tree Scientific Software. While PSTess shares a common lineage with PST Version 3.0, it is a substantially different application. This document supplements the main PST manual by describing the features and models that are unique to PSTess. As the name implies, the main distinguishing characteristic of PSTess is its ability to model inverter-based energy storage systems (ESS). The model that enables this is called ess.m , and it serves the dual role of representing ESS operational constraints and the generator/converter interface. As in the WECC REGC_A model, the generator/converter interface is modeled as a controllable current source with the ability to modulate both real and reactive current. The model ess.m permits four-quadrant modulation, which allows it to represent a wide variety of inverter-based resources beyond energy storage when paired with an appropriate supplemental control model. Examples include utility-scale photovoltaic (PV) power plants, Type 4 wind plants, and static synchronous compensators (STATCOM). This capability is especially useful for modeling hybrid plants that combine energy storage with renewable resources or FACTS devices.

97 MATHEMATICS AND COMPUTING↗

HybridPlan: A Capacity Planning Technique for Projecting Storage Requirements in Hybrid Storage Systems

Economic forces, driven by the desire to introduce flash into the high-end storage market without changing existing software-base, have resulted in the emergence of solid-state drives (SSDs), flash packaged in HDD form factors and capable of working with device drivers and I/O buses designed for HDDs. Unlike the use of DRAM for caching or buffering, however, certain idiosyncrasies of NAND Flash-based solid-state drives (SSDs) make their integration into hard disk drive (HDD)-based storage systems nontrivial. Flash memory suffers from limits on its reliability, is an order of magnitude more expensive than the magnetic hard disk drives (HDDs), and can sometimes be as slow as the HDD (due to excessive garbage collection (GC) induced by high intensity of random writes). Given the complementary properties of HDDs and SSDs in terms of cost, performance, and lifetime, the current consensus among several storage experts is to view SSDs not as a replacement for HDD, but rather as a complementary device within the high-performance storage hierarchy. Thus, we design and evaluate such a hybrid storage system with HybridPlan that is an improved capacity planning technique to administrators with the overall goal of operating within cost-budgets. HybridPlan is able to find the most cost-effective hybrid storage configuration with different types of SSDs and HDDs

Capacity Planning↗

The fuel integrity analysis of transfer processes for Chinshan dry-storage system by FRAPTRAN/CFD

The dry cask storage operation is separated into 3 stages: handling, transfer, and storage. In this study, the handling and transfer stages were established by CFD (Computational Fluid Dynamics). In order to obtain the burnup information of a single rod in the core, a single rod of Chinshan NPP was modeled by FRAPCON-3.5 and FRAPTRAN-1.5. Then, using the boundary condition from the CFD analysis, the fuel behaviors and performances were analyzed in detail with the FRAPTRAN-1.5 code. Three different thermal loads were considered in this paper: 7 kW, 14 kW, and 21 kW. The simulation results showed that, in all the cases: first, during the handling and transfer stages, the maximum cladding temperature was in the range of 477 to 653 K; secondly, the maximum cladding hoop strain was in the range of 0.0018 to 0.0025; and thirdly, the structural radial gap was almost kept as a constant. Based on these results, the fuel cladding integrity was maintained in the handling and transfer stages. These results help evaluating the safety issue of the dry-storage system for Chinshan NPP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-Objective Optimization for Power Electronics used in Grid-Tied Energy Storage Systems

Multi-objective optimization is used to find a nondominated set of solutions for two conflicting performance metrics or objective functions. These functions are dependent variables in the system, controlled by a set of independent variables called decision variables. The decision variables represent the inputs to the problem, chosen by the system designer, and are values listed in the solution set. In this study, a multi-objective genetic algorithm compared insulated-gate bipolar transistor (IGBT) failure rate to filter and cooling system costs. This study demonstrated the use of multi-objective optimization for energy storage systems. IGBT failure rate was compared to its associated filter and cooling-system costs as part of the DC-AC inverter power electronics system in a battery energy storage system (BESS). The independent or decision variables were determined to be switching frequency and thermal resistance of a heat sink, R sink . The final results indicated that high values of switching frequency increased the effects of R sink . Future work will add additional objective functions and decision variables to the study to optimize additional components in the power electronics system and BESS.

25 ENERGY STORAGE↗

Workload-Adaptive Management of Energy-Smart Disk Storage Systems

Recent studies have identified disk storage systems as one of the major consumers of power in data centers. Many disk power management (DPM) schemes were suggested where the power consumed by disks is reduced by spinning them down during long idle periods. Spinning the disks down and up results in additional energy and response time costs. For that reason, DPM schemes are effective only if the disks experience relatively long idle periods and the scheme does not introduce a severe response time penalty. In this paper we introduce a dynamic block exchange algorithm which switches data between disks based on the observed workload such that frequently accessed blocks end up residing on a few"hot" disks thus allowing the majority of disks to experience longer idle periods. We validate the effectiveness of the algorithm with trace-driven simulations showing power savings of up to 60percent with very small response time penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL-22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance. This foreword1 provides general and specific details about what additions, revisions, and enhancements have been made to the June 2014 Protocol and the rationale for them in arriving at this March 2016 Protocol (PNNL-22010 Rev. 2).

25 ENERGY STORAGE↗

Battery-ultracapacitor hybrid energy storage system architecture for mild-hybrid power systems

A mild-hybrid energy storage system architecture is provided, comprising: a battery; an ultracapacitor connected in parallel with the battery; a passive battery pre-charge circuit connected between a terminal of the battery and a DC bus; a battery main contactor connected in parallel with the battery pre-charge circuit between the terminal of the battery and the DC bus; a passive ultracapacitor pre-charge circuit connected between a terminal of the ultracapacitor and the DC bus; an ultracapacitor main contactor connected in parallel with the ultracapacitor pre-charge circuit between the terminal of the ultracapacitor and the DC bus; and a control module configured to independently control operation of the battery pre-charge circuit, the battery main contactor, the ultracapacitor pre-charge circuit and the ultracapacitor main contactor.

Varigonda, Subbarao↗

Statement of Work Electrical Energy Storage System Installation at Sandia National Laboratories.

Sandia is seeking to procure a 1 MWh energy storage system. It will be installed at the existing Energy Storage Test Pad, which is located at Sandia National Laboratories in Albuquerque, New Mexico. This energy storage system will be a daily operational system, but will also be used as a tool in our Research and development work. The system will be part of a showcase of Sandia distributed energy technologies viewed by many distinguished delegates.

25 ENERGY STORAGE↗

A File Allocation Strategy for Energy-Efficient Disk Storage Systems

Exponential data growth is a reality for most enterprise and scientific data centers.Improvements in price/performance and storage densities of disks have made it both easy and affordable to maintain most of the data in large disk storage farms. The provisioning of disk storage farms however, is at the expense of high energy consumption due to the large number of spinning disks. The power for spinning the disks and the associated cooling costs is a significant fraction of the total power consumption of a typical data center. Given the trend of rising global fuel and energy prices and the high rate of data growth, the challenge is to implement appropriateconfigurations of large scale disk storage systems that meet performancerequirements for information retrieval across data centers. We present part of the solution to this challenge with an energy efficient file allocation strategy on a large scale disk storage system. Given performance characteristics of thedisks, and a profile of the workload in terms of frequencies of file requests and their sizes, the basic idea is to allocate files to disks such that the disks can be configured into two sets of active (constantly spinning), and passive (capable of being spun up or down) disk pools. The goal is to minimize the number of active disks subject to I/O performance constraints. We present an algorithm for solving this problem with guaranteed bounds from the optimal solution. Our algorithm runs in O(n) time where n is the number of files allocated. It uses a mapping of our file allocation problem to a generalization of the bin packing problem known as 2-dimensional vector packing. Detailed simulation results are also provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetically Levitated and Constrained Flywheel Energy Storage System

The concept of using linear induction motors to lift, constrain, accelerate, and decelerate a large-scale flywheel is proposed, and some of the advantages are investigated. Calculations for a Magnetically Levitated Energy Storage System (MLES) are performed that compare a single large scale MLES with a current state of the art flywheel energy storage system in order to show the relative differences and advantages of such a system. The system that is used for comparison is a typical Beacon Power flywheel energy system. This is currently one of the state-of-the-art flywheel energy storage systems and so it can be used to provide a basic data set to compare to an MLES system.

VanOsdol, John↗

Systems and methods for randomized, packet-based power management of conditionally-controlled loads and bi-directional distributed energy storage systems

The present disclosure provides a distributed and anonymous approach to demand response of an electricity system. The approach conceptualizes energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Data requirements for improving the Quantitative Risk Assessment of liquid hydrogen storage systems

Quantitative Risk Assessment (QRA) supports the development of risk-informed safety codes and standards which are employed to enable the safe deployment of hydrogen technologies essential to decarbonize the transportation sector. System reliability data is a necessary input for rigorous QRA. Here, the lack of reliability data for bulk liquid hydrogen (LH 2 ) storage systems located on site at fueling stations limits the use of QRAs. In turn, this hinders the ability to develop the necessary safety codes and standards that enable worldwide deployment of these stations. Through a QRA-based analysis of a LH 2 storage system, this work focuses on identifying relevant scenario and probability data currently available and ascertaining future data collection requirements regarding risks specific to liquid hydrogen releases. The work developed consists of the analysis of a general bulk LH 2 storage system design located at a hydrogen fueling station. Failure Mode and Effect Analysis (FMEA) and traditional QRA modeling tools such as Event Sequence Diagrams (ESD) and Fault Tree Analysis (FTA) are employed to identify, rank, and model risk scenarios related to the release of LH 2 . Based on this analysis, scenario and reliability data needs to add LH 2 -related components to QRA are identified with the purpose of improving the future safety and risk assessment of these systems.

08 HYDROGEN↗

DOE OE Energy Storage Systems Safety Roadmap Focus on Codes and Standards - February 2018

The goal of the DOE OE ESS Safety Roadmap1 is to foster confidence in the safety and reliability of energy storage systems. There are three interrelated objectives to support the realization of that goal: research, codes and standards and communication/coordination. The objective focused on codes and standards is: To apply research and development to support efforts that are focused on ensuring that codes and standards are available to enable the safe implementation of energy storage systems in a comprehensive, non-discriminatory and science-based manner. The following activities support that objective and realization of the goal: a. Review and assess codes and standards which affect the design, installation, and operation of ESS systems. b. Identify gaps in knowledge that require research and analysis that can serve as a basis for criteria in those codes and standards. c. Identify areas in codes and standards that are potentially in need of revision or enhancement and can benefit from activities conducted under research and development. d. Develop input for new or revisions to existing codes and standards through individual stakeholders, facilitated task forces, or through laboratory staff supporting these efforts. The purpose of this document is to support the above activities by providing information on current and upcoming efforts being conducted by U.S. standards developing organizations (SDOs) and other entities that are focused on energy storage system safety.

25 ENERGY STORAGE↗

Modular thermal energy storage system

A thermal energy storage (TES) system includes a plurality of closely packed TES modules, each TES module having a shell enclosing a plurality of sealed tubes that each contain a TES media. A computer-controlled flow control system includes a flow distributor, for example a flow distributor having a plenum configured to receive a heat transfer fluid (HTF), and a plurality of control valves controlled by the computer to controllably distribute the HTF from the plenum to the plurality of TES modules. Sensor data from the TES modules, for example temperature, pressure, and/or flow data, is provided to the computer. In some embodiments the plenum includes two or more compartments with separate HTF flow ports, which may be provided to the controller at different temperatures.