Search NASA⌕ Search

SEARCH · Search NASA

Results for “Subcooled flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

156 records · Page 9

Effect of Residual Noncondensables on Pressurization and Pressure Control of a Zero-Boil-Off Tank in Microgravity

The Zero-Boil-Off Tank (ZBOT) Experiment is a small-scale experiment that uses a transparent ventless Dewar and a transparent simulant phase-change fluid to study sealed tank pressurization and pressure control with applications to on-surface and in-orbit storage of propellant cryogens. The experiment will be carried out under microgravity conditions aboard the International Space Station in the 2014 timeframe. This paper presents preliminary results from ZBOT's ground-based research that focuses on the effects of residual noncondensable gases in the ullage on both pressurization and pressure reduction trends in the sealed Dewar. Tank pressurization is accomplished through heating of the test cell wall in the wetted and un-wetted regions simultaneously or separately. Pressure control is established through mixing and destratification of the bulk liquid using a temperature controlled forced jet flow with different degrees of liquid jet subcooling. A Two-Dimensional axisymmetric two-phase CFD model for tank pressurization and pressure control is also presented. Numerical prediction of the model are compared to experimental 1g results to both validate the model and also indicate the effect of the noncondensable gas on evolution of pressure and temperature distributions in the ullage during pressurization and pressure control. Microgravity simulations case studies are also performed using the validated model to underscore and delineate the profound effect of the noncondensables on condensation rates and interfacial temperature distributions with serious implications for tank pressure control in reduced gravity.

Marangoni and Natural Convection↗

Combined buoyancy and flow direction effects on saturated boiling critical heat flux in liquid nitrogen

Buoyancy effects on the critical heat flux and general data trends for a liquid nitrogen internal flow system were determined by comparison of upflow and downflow data under identical test conditions. The test section had a 1.28 cm diameter flow passage and a 30.5 cm heated length which was subjected to uniform heat fluxes through resistance heating. Test conditions covered a range of pressures from 3.4 to 10.2 atm, inlet velocities from 0.23 to 3.51 m/sec, with the liquid nitrogen temperature at saturated inlet conditions. Data comparisons showed that the critical heat flux for downflow could be up to 36 percent lower than for upflow. A nonmonotonic relationship between the critical heat flux and velocity was determined for upflow but not for downflow. A limiting inlet velocity of 4.12 m/sec was determined to be the minimum velocity required to completely suppress the influence of buoyancy on the critical heat flux for this saturated inlet flow system. A correlation of this limiting fluid velocity is presented that was developed from previously published subcooled liquid nitrogen data and the saturated data of this investigation.

Papell, S. S.↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83% by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/sq m). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 C, respectively. The boiling process during the entire heating period, as well as the jet-induced mixing process for the first 2 min of the mixing period, was also recorded on video. The unique features of the experimental results are the sustainability of high liquid superheats for long periods and the occurrence of explosive boiling at low heat fluxes (0.86 to 1.1 kW/sq m). For a heat flux of 0.97 kW/sq m, a wall superheat of 17.9 C was attained in 10 min of heating. This superheat was followed by an explosive boiling accompanied by a pressure spike of about 38% of the tank pressure at the inception of boiling. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Steady nucleate boiling continued after the explosive boiling. The jet-induced fluid mixing results were obtained for jet Reynolds numbers of 1900 to 8000 and Weber numbers of 0.2 to 6.5. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number.

Hasan, Mohammad M.↗

Effect of surface oxidation on the onset of nucleate boiling in a materials test reactor coolant channel

The onset of nucleate boiling (ONB) serves as the thermal-hydraulic operating limit for many research and test reactors. However, boiling incipience under forced convection has not been well-characterized in narrow channel geometries or for oxidized surface conditions. This study presents experimental data for the ONB in vertical upflow of deionized (DI) water in a simulated materials test reactor (MTR) coolant channel. The channel gap thickness and aspect ratio were 1.96 mm and 29:1, respectively. Boiling surface conditions were carefully controlled and characterized, with both heavily oxidized and native oxide surfaces tested. Measurements were performed for mass fluxes ranging from 750 to 3000 kg/m 2 s and for subcoolings ranging from 10 to 45°C. ONB was identified using a combination of high-speed visual observation, surface temperature measurements, and channel pressure drop measurements. Surface temperature measurements were found to be most reliable in identifying the ONB. For the nominal (native oxide) surface, results indicate that the correlation of Bergles and Rohsenow, when paired with the appropriate single-phase heat transfer correlation, adequately predicts the ONB heat flux. Furthermore, incipience on the oxidized surface occurred at a higher heat flux and superheat than on the plain surface.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.

Computational Fluid Dynamics↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.

Computational Fluid Dynamics↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters the room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFD-based modeling framework employing the mixture multiphase model has been developed to simulate this chilldown process and applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a two test conditions are simulated to test the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and is considered in the CFD model. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. Simulated vapor volume fraction distributions are also presented, although the current lack of experimental volume fraction data does not permit a comparison.

Computational Fluid Dynamics↗

Modeling of a Two-Phase Jet Pump with Phase Change, Shocks and Temperature-Dependent Properties

One of the primary motivations behind this work is the attempt to understand the physics of a two-phase jet pump which constitutes part of a flow boiling test facility at NASA-Marshall. The flow boiling apparatus is intended to provide data necessary to design highly efficient two-phase thermal control systems for aerospace applications. The facility will also be capable of testing alternative refrigerants and evaluate their performance using various heat exchangers with enhanced surfaces. The test facility is also intended for use in evaluating single-phase performance of systems currently using CFC refrigerants. Literature dealing with jet pumps is abundant and covers a very wide array of application areas. Example application areas include vacuum pumps which are used in the food industry, power station work, and the chemical industry; ejector systems which have applications in the aircraft industry as cabin ventilators and for purposes of jet thrust augmentation; jet pumps which are used in the oil industry for oil well pumping; and steam-jet ejector refrigeration, to just name a few. Examples of work relevant to this investigation includes those of Fairuzov and Bredikhin (1995). While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the author apart from that of Anand (1992) who was able to account for condensation shocks. Thus, one of the objectives of this work is to model the dynamics of fluid interaction between a two-phase primary fluid and a subcooled liquid secondary fluid which is being injected employing atomizing spray injectors. The model developed accounts for phase transformations due to expansion, compression, and mixing. It also accounts for shock waves developing in the different parts of the jet pump as well as temperature and pressure dependencies of the fluid properties for both the primary two-phase mixture and the secondary subcooled liquid. The research effort on which this document partly reports described a relatively simple model capable of describing the performance of a two-phase flow jet pump. The model is based on the isentropic homogeneous expansion/compression hypothesis and is capable of fully incorporating the effects of shocks in both the mixing chamber and the throat/diffuser parts of the pump. The physical system chosen is identical to that experimentally tested by Fairuzov and Bredikhin (1995) and should therefore be relatively easy to validate.

Sherif, S. A.↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency spectrum analysis code for nuclear noise based on improved wavelet algorithm - 337

The core of the narrow flow channel generally faced the problem of local bubble boiling with the temperature rise of the nuclear fuel element, it is necessary and meaningful to answer and deal with the problem on the technical level. Reactor noise analysis begins with the study of the physical characteristics of the core, after nearly 30 years of research and development it has become a powerful tool in the auxiliary monitoring of the power reactor operating. By using this noise frequency spectrum analysis technology, the reactor dynamic parameter such as prompt neutron decay constant can be measured. Also, through such system, the frequency characteristics of reactor can be real-time monitored, which is helpful for safety operation and fault diagnosis. Spectrum analysis technology in the Fourier analysis era is now barely available, the reason is that the local spectral characteristics of this technology are not obvious, but this defect can be greatly improved by wavelet analysis technique, however, the traditional wavelet analysis will introduce the problem of spectral confusion. To solve the problem, based on the improved wavelet algorithm, frequency spectrum analysis code for nuclear noise is developed,from the perspective of fine spectral analysis, the local boiling accident of the coolant can be prejudged and avoid. Based on the analysis and test of experimental data,The results show that the calculation ability of the code is in accordance with the expected, it can be applied in the operation of research reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors

The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗