Voyager capsule phase B. Volume III - Surface laboratory system. Part E - Reliability Final report
Voyager capsule surface laboratory system - reliability
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Voyager capsule surface laboratory system - reliability
Lunar surface mobility systems comparison and evolution
Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.
Solar electric power application to advanced planetary surface observation system, emphasizing communication and system requirements
The Lightweight Surface Manipulation System is a long-reach, low mass, deployable manipulator, using design principles of structurally efficient commercial cranes, with the enhanced dexterity and multi-functionality of a robotic arm. This is a presentation given to Blue Origin on 08/21/20.
Voyager capsule surface laboratory system - design concepts and objectives
Purpose: To evaluate the clinical suitability of a specific optical surface imaging system to detect setup errors in fractionated radiation therapy. Methods and Materials: The setup correction accuracy of a 3-dimensional laser imaging system was analyzed for 6 different tumor locations with 20 patients each. For each patient, the setup corrections of the megavoltage computed tomography (MVCT) images of a TomoTherapy unit (TomoTherapy, Madison, WI) were compared with those of the laser system for the first 10 fractions. For the laser system, the reference surface either was obtained from the DICOM (Digital Imaging and Communications in Medicine) surface structure delineated on the planning computed tomography images or was acquired with the system itself at the first fraction after the MVCT-based setup correction. Data analysis was performed for both reference types. Results: By use of the DICOM reference image, systematic shifts between 3 and 9 mm were found, depending on the tumor location. For the optical reference, no clinically relevant systematic shifts were found. MVCT-based setup corrections were detected with high accuracy, and only small movements were observed during treatment. Conclusions: Using a reference image acquired with the laser system itself after MVCT-based setup correction appears more reliable than importing the DICOM reference surface. After generation of the optical reference, the laser system may be used to derive setup corrections over a certain number of fractions, but additional radiologic imaging may still be necessary on a regular basis (eg, weekly) or if the corrections of the optical system appear implausibly large. Nevertheless, such a combined application may help to reduce the imaging dose for the patient.
Voyager capsule surface laboratory system - subsystem functional descriptions
Voyager capsule surface laboratory system - subsystem functional descriptions
Voyager capsule surface laboratory system - subsystem design analysis
Voyager capsule surface laboratory system - subsystem design analysis
Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.
Lunar surface mobility systems comparison and evolution study for advanced roving and flying vehicles
Two proposed stabilization methods for X-15 horizontal surface control system
Voyager capsule surface laboratory system - operational support equipment
Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.
The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.
Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.