Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

May 2012 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 9-10, 2012, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the site boundaries have not been affected by project-related contaminants.

54 ENVIRONMENTAL SCIENCES↗

May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method. Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.

54 ENVIRONMENTAL SCIENCES↗

Y-12 Groundwater Protection Program Groundwater And Surface Water Sampling And Analysis Plan For Calendar Year 2014

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2014 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring is performed by the GWPP during CY 2014 to achieve the following goals: 􀁸 to protect the worker, the public, and the environment; 􀁸 to maintain surveillance of existing and potential groundwater contamination sources; 􀁸 to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; 􀁸 to identify and characterize long-term trends in groundwater quality at Y-12; and 􀁸 to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring will be performed in three hydrogeologic regimes at Y-12.

54 ENVIRONMENTAL SCIENCES↗

Strong localized interaction of microplasma discharges with titanium

Excitation of microplasma discharges on the surfaces of titanium samples placed in a uniform pulsed plasma flow was studied experimentally. Strong localized interaction of microplasma discharges with titanium leads to the rapid melting and subsequent fast cooling of micrometer-size regions on the sample surface. Due to the multiple action of microplasma discharges, a continuous remelted layer with a thickness of up to 20 {mu}m forms on the titanium surface. The physical, structural, and tribotechnical properties of this layer differ substantially from those before microplasma processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confocal Raman microscopy of self-assembled GeSi/Si(001) Islands

The method of confocal Raman microscopy is used for the first time to study the spatial distribution of elemental composition and elastic strains in self-assembled GexSi{sub 1-x}/Si(001) islands grown by the method of sublimation molecular-beam epitaxy in the GeH{sub 4} ambient. The lines related to vibrational modes Si-Si, Ge-Ge, and Si-Ge are identified in the Raman spectra measured in the regions with dimensions <100 nm on the surface of the samples. The spatial distribution of the Ge atomic fraction x in the Ge{sub x}Si{sub 1-x} alloy and of the elastic strain {epsilon} (averaged in depth over the island layer) have been calculated from the maps of the Raman shifts of the corresponding lines over the sample surface. The dependences of x and {epsilon} on the islands' growth temperature and on the nominal thickness of the deposited Ge layer have been studied.

36 MATERIALS SCIENCE↗

Advanced probabilistic risk analysis using RAVEN and RELAP-7

RAVEN, under the support of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program [1], is advancing its capability to perform statistical analyses of stochastic dynamic systems. This is aligned with its mission to provide the tools needed by the Risk Informed Safety Margin Characterization (RISMC) path-lead [2] under the Department Of Energy (DOE) Light Water Reactor Sustainability program [3]. In particular this task is focused on the synergetic development with the RELAP-7 [4] code to advance the state of the art on the safety analysis of nuclear power plants (NPP). The investigation of the probabilistic evolution of accident scenarios for a complex system such as a nuclear power plant is not a trivial challenge. The complexity of the system to be modeled leads to demanding computational requirements even to simulate one of the many possible evolutions of an accident scenario (tens of CPU/hour). At the same time, the probabilistic analysis requires thousands of runs to investigate outcomes characterized by low probability and severe consequence (tail problem). The milestone reported in June of 2013 [5] described the capability of RAVEN to implement complex control logic and provide an adequate support for the exploration of the probabilistic space using a Monte Carlo sampling strategy. Unfortunately the Monte Carlo approach is ineffective with a problem of this complexity. In the following year of development, the RAVEN code has been extended with more sophisticated sampling strategies (grids, Latin Hypercube, and adaptive sampling). This milestone report illustrates the effectiveness of those methodologies in performing the assessment of the probability of core damage following the onset of a Station Black Out (SBO) situation in a boiling water reactor (BWR). The first part of the report provides an overview of the available probabilistic analysis capabilities, ranging from the different types of distributions available, possible sampling strategies, and post processing analysis capabilities. The first part of the report provides an extensive description of two major developments introduced this year: adaptive sampling for limit surface sampling and multi variate distributions. The document concludes with a description of the demo case (BWR-SBO) and a discussion of the results obtained.

97 MATHEMATICS AND COMPUTING↗

Oxidation of Alloy X in Subcritical, Transition, and Supercritical Water

This work investigates the oxidation of a nickel-based superalloy, namely Alloy X, in water at elevated temperatures: subcritical water at 261°C and 27 MPa, the transition between subcritical and supercritical water at 374°C and 27 MPa, and supercritical water at 380°C and 27 MPa for 100 h. The morphology of the sample surfaces were studied using scanning electron microscopy coupled with focused ion beam milling, and the surface chemistry was investigated using x-ray diffraction, Raman spectroscopy, energy dispersive x-ray spectroscopy, and x-ray photoelectron spectroscopy before and after exposure studies. Surfaces of all samples were identified to comprise of a ferrite spinel containing aluminum.

Materials Science↗

Atmospheric Pressure Surface Sampling/Ionization Techniques for Direct Coupling of Planar Separations with Mass Spectrometry

Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in-situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature.

Atmospheric Pressure Surface Sampling↗

May 2013 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 14-16, 2013, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location CER #1 Black Sulphur. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package August 2015 Groundwater and Surface Water Sampling at the Tuba City, Arizona, Disposal Site November 2015

The groundwater compliance strategy for the Tuba City, Arizona, Disposal Site is defined in the 1999 Phase I Ground Water Compliance Action Plan for the Tuba City, Arizona, UMTRA Site. Samples are collected and analyzed on a semiannual basis to evaluate the performance of the Phase I remediation system. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). U.S. Environmental Protection Agency (EPA) groundwater standards were exceeded in samples collected from monitoring wells and extraction wells as listed in Table 1. The data from this sampling event are generally consistent with previously obtained values and are acceptable for general use as qualified. Data anomalies are not significant with respect to the known nature and extent of contamination and progress of remedial action at the site. The data from this sampling event will be incorporated into the annual performance evaluation report that will present a comprehensive hydrologic summary and evaluation of groundwater remedial action performance at the Tuba City site through March 2016.

2015 Tuba City, AZ Groundwater and Surface Water S↗

Data Validation Package - June 2015 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

Groundwater samples were collected during the 2015 sampling event from point-of-compliance (POC) wells 0171, 0173, 0176, 0179, 0181, and 0813 to monitor the disposition of contaminants in the middle sandstone unit of the Cedar Mountain Formation. Groundwater samples also were collected from alluvium monitoring wells 0188, 0189, 0192, 0194, and 0707, and basal sandstone monitoring wells 0182, 0184, 0185, and 0588 as a best management practice. Surface locations 0846 and 0847 were sampled to monitor for degradation of water quality in the backwater area of Brown’s Wash and in the Green River immediately downstream of Brown’s Wash. The Green River location 0801 is upstream from the site and is sampled to determine background-threshold values (BTVs). Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Water levels were measured at each sampled well. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. All six POC wells are completed in the middle sandstone unit of the Cedar Mountain Formation and are monitored to measure contaminant concentrations for comparison to proposed alternate concentration limits (ACLs), as provided in Table 1. Contaminant concentrations in the POC wells remain below their respective ACLs.

54 ENVIRONMENTAL SCIENCES↗

Surface Erosion of Plasma-Facing Materials Using an Electrothermal Plasma Source and Ion Beam Micro-Trenches

Erosion characteristics of tungsten-alternative plasma-facing materials (PFMs) were tested under high heat flux conditions in the electrothermal plasma source facility at Oak Ridge National Laboratory. The PFMs of interest are high-purity β-3C chemical vapor deposition silicon carbide (SiC) and the MAX phases Ti 3 SiC 2 and Ti 2 AlC [MAX = chemical formula M n+1 AX n , where M is an early transition metal (such as Ti or Ta), A is an A-group element (such as Si or Al), and X is carbon or nitrogen]. Additionally, an erosion analysis method was developed using a combination of focused ion beam microscopy and scanning electron microscopy, carving micro-trench geometries into polished sample surfaces. Samples of SiC, Ti 3 SiC 2 , and Ti 2 AlC were exposed to the electrothermal plasma source alongside tungsten and monocrystalline silicon. Samples were exposed to a Lexan polycarbonate (C 16 H 14 O 3 ) electrothermal plasma stream in a He environment, at a specified impact angle, with infrared camera diagnostics. Edge localized mode–relevant heat fluxes of 0.9 to 1 GW/m 2 over 1-ms discharges were generated on the target surfaces. Tungsten samples exhibited pronounced melt-layer formation and deformation, with measured molten pits 2 to 10 μm in diameter and melt-layer depths of up to 7 μm deep. Surface erosion rates for Ti 3 SiC 2 and Ti 2 AlC ranged from 80 to 775 μm/s and 85 to 470 μm/s, respectively. Both MAX phases exhibited extreme surface fracture and material ejection, with damage depths past 4 μm for Ti 2 AlC and 11 μm for Ti 3 SiC 2 . Lastly, SiC displayed the best performance, in one case surviving 15 consecutive electrothermal plasma exposures with an average erosion rate of about 29 μm/s and no surface fracturing. SiC erosion rates ranged from 23 to 128 μm/s.

36 MATERIALS SCIENCE↗

Corrosion Behavior of Sm{sub y}(Fe{sub x}Ni{sub 1−x}){sub 4}Sb{sub 12} (0.40 ≤ x ≤ 0.80) in NaCl Solutions Studied by Electron Microscopy and ICP-AES

Filled skutterudites are currently studied as thermoelectric materials to be used in the automotive and nautical field; the study of their resistance to a saline environment is therefore mandatory. To this purpose, the corrosion behavior of several compositions belonging to the Sm{sub y}(Fe{sub x}Ni{sub 1−x}){sub 4}Sb{sub 12} skutterudites system was investigated by immersing samples in differently concentrated (0.1 and 0.5 M) NaCl solutions. The effect of the treatment was analyzed both by SEM–EDS on the sample surface and at fixed times by ICP-AES on the solution. The formation of an oxide layer was observed on the surface of all the samples: the film results uniformly grown on specimens treated in NaCl at the lower concentration, while it is cracked and not spread over the whole surface in the other samples. Relying on the oxide layer thickness, the oxidation resistance results to increase with increasing the Fe content; correspondingly, the Sb concentration in the more diluted solution decreases at each time considered with increasing the Fe amount, pointing at a strict correlation between the cationic release and the oxide formation, and suggesting a possible mechanism for the growth of the protective film.

36 MATERIALS SCIENCE↗

Elemental and isotopic analysis of inorganic salts by laser desorption ionization mass spectrometry

Laser desorption ionization mass spectrometry is applied for the analysis of elements as well as their isotopic composition in different inorganic salts. At very low laser energies the inorganic ions are desorbed and ionized from the thin layer of the sample surface. The naturally occurring isotopes of alkali and silver ions are resolved using time of flight mass spectrometer. Further increase in laser energy shows the appearance of Al, Cr, and Fe ions in the mass spectra. This indicates the penetration laser beam beyond the sample surface leading to the ablation of sample target at higher energies. The simultaneous appearance of atomic ions from the sample target at relatively higher laser energies hampers the unambiguous identification of amino acid residues from the biomolecular ions in MALDI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface characterization based on optical phase shifting interferometry

Apparatus, techniques and systems for implementing an optical interferometer to measure surfaces, including mapping of instantaneous curvature or in-plane and out-of-plane displacement field gradients of a sample surface based on obtaining and processing four optical interferograms from a common optical reflected beam from the sample surface that are relatively separated in phase by .pi./2.

47 OTHER INSTRUMENTATION↗

Local triboelectrification of an n-GaAs surface using the tip of an atomic-force microscope

The method of scanning Kelvin-probe microscopy is used to show that the effect of triboelectrification is observed when the tip of an atomic-force microscope interacts with the surface of n-GaAs epitaxial layers. The sign of the change in the potential indicates that the sample surface after triboelectrification becomes more negative. The observed specific features of the phenomena can be attributed to the thermally activated generation of point defects in the vicinity of the sample surface due to deformation caused by the tip.

36 MATERIALS SCIENCE↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from -20 to 01100 V/mm for E kin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for E kin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at E kin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field -21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm 2 , it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at E kin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments.

47 OTHER INSTRUMENTATION↗