Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface thermocouples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermographic monitoring of materials under simulated reentry conditions

Thermography can be used to measure surface temperature gradients graphically, and can be used under conditions where the direct measurement of temperature at all desired points, using thermocouples or resistance temperature detectors (RTDs), is either difficult or impossible. The use of thermographic monitoring during a series of arc-jet tests is described. Described in this work are the issues that influence interpretation of the thermographic measurements under these conditions, including the calculation of effective emittance and window transmittance from the spectral properties of the materials in order to calculate the temperature distribution of a surface directly from the measured radiance. Comparison of the surface temperatures measured using thermocouples and the temperatures derived from thermographic measurements show good agreement. The data gathered will be used to evaluate important test parameters such as the heating distribution across the surface of a heat shield test model and at steps on the model surface.

White, Susan M.↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

In order to accommodate the growing thermal management needs of future space platforms, several two-phase active thermal control systems (ATCSs) have evolved and were included in the designs of space stations. Compared to the pumped single-phase liquid loops used in the conventional Space Transportation System and Spacelab, ATCSs offer significant benefits that may be realized by adopting a two-phase fluid-loop system. Alternately, dynamic power systems (DPSs), based on the Rankine cycle, seem inevitably to be required to supply the electrical power requirements of expanding space activities. Boiling heat transfer is one of the key technologies for both ATCSs and DPSs. Nucleate boiling near critical heat flux (CHF) can transport very large thermal loads with much smaller device size and much lower pumping power. However, boiling performance deteriorates in a reduced gravity environment and operation in the CHF regime is precarious because any slight overload will cause the heat transfer to suddenly move to the film boiling regime, which in turn, will result in burnout of the heat transfer surfaces. New materials, such as micro-configured metal-graphite composites, can provide a solution for boiling enhancement. It has been shown experimentally that this type of material manifests outstanding boiling heat transfer performance and their CHF is also extended to higher values. Due to the high thermal conductivity of graphite fiber (up to 1,200 W/m-K in the fiber direction), the composite surfaces are non-isothermal during the boiling process. The composite surfaces are believed to have a much wider safe operating region (a more uniform boiling curve in the CHF regime) because non-isothermal surfaces have been found to be less sensitive to variations of wall superheat in the CHF regime. The thermocapillary forces formed by the temperature difference between the fiber tips and the metal matrix play a more important role than the buoyancy in the bubble detachment, for the bubble detachment manifests itself by a necking process which should not be weakened by reduced gravity. In addition, the composite surfaces introduce no extra pressure drop, no fouling and do not impose significant primary or maintenance costs. All of these suggest that this type of composite is an ideal material for the challenge of accounting for both reliability and economy of the relevant components applied in the ATCSs, the DPSs and other devices in future space missions. The aim of the proposed work is to experimentally investigate high nucleate pool boiling performance on a micro-configured metal-graphite composite surface and to determine the mechanisms of the nucleate boiling heat transfer both experimentally and theoretically. Freon-113 and water will be used as the test liquids to investigate wettability effects on boiling characteristics. The Cu-Gr and Al-Gr composites with various volume fractions of graphite fibers will be tested to obtain the heat transfer characteristic data in the nucleate boiling region and in the CHF regime. In the experiments, the bubble emission and coalescence processes will be recorded by a video camera with a magnifying borescope probe immersed in the working fluid. The temperature profile in the thermal boundary layer on the composite surfaces will be measured by a group of micro thermocouples consisting of four ultra fine micro thermocouples. This instrument was developed and successfully used to measure the temperature profile of evaporating liquid thin layers by the proposers in a study performed at the NASA/Lewis Research Center. A two tier model to explain the nucleate boiling process and the performance enhancement on the composite surfaces has been suggested by the authors. According to the model, the thicknesses of the microlayer and the macrolayer underneath the bubbles and mushrooms, can be estimated by the geometry of the composite surface. The experimental results will be compared to the predictions from the model, and in turn, to revise and improve it.

Zhang, Nengli↗

MEDLI2 Material Response Model Development and Validation

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating and temperatures. Discrepancies between MEDLI’s recorded in-depth heating data and the predicted thermal response and recession led to a campaign to characterize and test Mars Entry, Descent, and Landing Instrument 2 (MEDLI2) flight lot thermal protection materials (TPS) at relevant temperatures and pressures for Martian entry conditions. This paper covers the development and validation of MEDLI2 flight lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material Super-Lightweight Ablator (SLA-561V). Virgin and char thermal conductivities were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties such as virgin and char density, emissivity, absorptivity, and specific heat capacitance was also characterized and compared to the “Heritage” models used during the TPS design phase of Mars 2020. Fully Implicit Ablation and Thermal response (FIAT) simulations were completed using the Heritage and MEDLI2 material response models to provide evidence of the increased accuracy of the MEDLI2 model. FIAT predicted in-depth temperatures were compared to flight lot certification ground-test arc jet test data and MEDLI2 flight thermocouple data.

Material response↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

Boundary Layer Transition on X-43A

The successful Mach 7 and 10 flights of the first fully integrated scramjet propulsion systems by the Hyper-X (X-43A) program have provided the means with which to verify the original design methodologies and assumptions. As part of Hyper-X s propulsion-airframe integration, the forebody was designed to include a spanwise array of vortex generators to promote boundary layer transition ahead of the engine. Turbulence at the inlet is thought to provide the most reliable engine design and allows direct scaling of flight results to groundbased data. Pre-flight estimations of boundary layer transition, for both Mach 7 and 10 flight conditions, suggested that forebody boundary layer trips were required to ensure fully turbulent conditions upstream of the inlet. This paper presents the results of an analysis of the thermocouple measurements used to infer the dynamics of the transition process during the trajectories for both flights, on both the lower surface (to assess trip performance) and the upper surface (to assess natural transition). The approach used in the analysis of the thermocouple data is outlined, along with a discussion of the calculated local flow properties that correspond to the transition events as identified in the flight data. The present analysis has confirmed that the boundary layer trips performed as expected for both flights, providing turbulent flow ahead of the inlet during critical portions of the trajectory, while the upper surface was laminar as predicted by the pre-flight analysis.

Berry, Scott↗

Comparison of Orbiter STS-2 development flight instrumentation data with thermal math model predictions

Thermal performance verification of Reusable Surface Insulation (RSI) has been accomplished by comparisons of STS-2 Orbiter Flight Test (OFT) data with Thermal Math Model (TMM) predictions. The OFT data was obtained from Development Flight Instrumentation RSI plug and gap thermocouples. Quartertile RSI TMMs were developed using measured flight data for surface temperature and pressure environments. Reference surface heating rates, derived from surface temperature data, were multiplied by gap heating ratios to obtain tile sidewall heating rates. This TMM analysis resulted in good agreement of predicted temperatures with flight data for thermocouples located in the RSI, Strain Isolation Pad, filler bar and structure.

Norman, I.↗

Use of a Multiwavelength Pyrometer in Several Elevated Temperature Aerospace Applications

A multiwavelength pyrometer was developed for applications unique to aerospace environments. It was shown to be a useful and versatile technique for measuring temperature, even when the emissivity is unknown. It has also been used to measure the surface temperatures of ceramic zircomia thermal barrier coatings and alumina. The close agreement between pyrometer and thin film thermocouple temperatures provided an independent check. Other applications of the multiwavelength pyrometer are simultaneous surface and bulk temperature measurements of a transparent material, and combustion gas temperature measurement using a special probe interfaced to the multiwavelength pyrometer via an optical fiber. The multiwavelength pyrometer determined temperature by transforming the radiation spectrum in a broad wavelength region to produce a straight line (in a certain spectral region), whose intercept in the vertical axis gives the temperature. Implicit in a two-color pyrometer is the assumption of wavelength independent emissivity. Though the two data points of a two-color pyrometer similarly processed would result immediately in a similar straight line to give the unknown temperature, the two-color pyrometer lacks the greater data redundancy of the multiwavelength pyrometer, which enables it to do so with improved accuracy. It also confirms that emissivity is indeed wavelength independent, as evidenced by a multitude of the data lying on a simple straight line. The multiwavelength pyrometer was also used to study the optical transmission properties of a nanostructured material from which a quadratic exponential functional frequency dependence of its spectral transmission was determined. Finally, by operating the multiwavelength pyrometer in a very wide field of view mode, the surface temperature distribution of a large hot surface was obtained through measurement of just a single radiation spectrum.

Ng, Daniel↗

A study of target heating in low-energy ion-beam processing

A bonded thermocouple approach is employed to accurately determine semiconductor surface heating profiles as a function of energy, position, and gas species in a high-current low-energy ion beam etching system. The total beam current is kept at 200 mA and the extractor voltage at 300 V. It is found that the ionic species, the radial position in the ion beam, and the kinetic energy of the ions, all of which effect the ion current density, must be taken into account in recording the temperature rise of the bombarded surface. It is also noted that the occurrence of this temperature rise is dependent on the thermal contacts and heat sinking.

Ringel, S. A.↗

Measurement of the Coolant Channel Temperatures and Pressures of a Cooled Radial-Inflow Turbine

Instrumentation has been installed on the surface of a cooled radial-inflow turbine. Thermocouples and miniature integrated sensor pressure transducers were installed to measure steady state coolant temperatures, blade wall temperatures, and coolant pressures. These measurements will eventually be used to determine the heat transfer characteristics of the rotor. This paper will describe the procedures used to install and calibrate the instrumentation and the testing methods followed. A limited amount of data will compare the measured values to the predicted values.

Dicicco, L. Danielle↗

Thermal Conductivity Change Kinetics of Ceramic Thermal Barrier Coatings Determined by the Steady-State Laser Heat Flux Technique

A steady-state laser heat flux technique has been developed at the NASA Glenn Research Center at Lewis Field to obtain critical thermal conductivity data of ceramic thermal barrier coatings under the temperature and thermal gradients that are realistically expected to be encountered in advanced engine systems. In this study, thermal conductivity change kinetics of a plasma-sprayed, 254-mm-thick ZrO2-8 wt % Y2O3 ceramic coating were obtained at high temperatures. During the testing, the temperature gradients across the coating system were carefully measured by the surface and back pyrometers and an embedded miniature thermocouple in the substrate. The actual heat flux passing through the coating system was determined from the metal substrate temperature drop (measured by the embedded miniature thermocouple and the back pyrometer) combined with one-dimensional heat transfer models.

Zhu, Dongming↗

Nonequilibrium Ablation of Phenolic Impregnated Carbon Ablator

In previous work, an equilibrium ablation and thermal response model for Phenolic Impregnated Carbon Ablator was developed. In general, over a wide range of test conditions, model predictions compared well with arcjet data for surface recession, surface temperature, in-depth temperature at multiple thermocouples, and char depth. In this work, additional arcjet tests were conducted at stagnation conditions down to 40 W/sq cm and 1.6 kPa. The new data suggest that nonequilibrium effects become important for ablation predictions at heat flux or pressure below about 80 W/sq cm or 10 kPa, respectively. Modifications to the ablation model to account for nonequilibrium effects are investigated. Predictions of the equilibrium and nonequilibrium models are compared with the arcjet data.

Milos, Frank S.↗

Mars2020 Entry, Descent, and Landing Instrumentation (MEDLI2): Science Objectives and Instrument Requirements

NASAs exploration and technology roadmaps call for capability advancements in Mars entry, descent, and landing (EDL) systems to enable increased landed mass, a higher landing precision, and a wider planetary access. It is also recognized that these ambitious EDL performance goals must be met while maintaining a low mission risk in order to pave the way for future human missions. As NASA is engaged in developing new EDL systems and technologies via testing at Earth, instrumentation of existing Mars missions is providing valuable engineering data for performance improvement, risk reduction, and an improved definition of entry loads and environment. The most notable recent example is the Mars Entry, Descent and Landing Instrument (MEDLI) suite hosted by Mars Science Laboratory for its entry in Aug 2012. The MEDLI suite provided a comprehensive dataset for Mars entry aerodynamics, aerothermodynamics and thermal protection system (TPS) performance. MEDLI data has since been used for unprecedented reconstruction of aerodynamic drag, vehicle attitude, in-situ atmospheric density, aerothermal heating, and transition to turbulence, in-depth TPS performance and TPS ablation. [1,2] In addition to validating predictive models, MEDLI data has demonstrated extra margin available in the MSL forebody TPS, which can potentially be used to reduce vehicle parasitic mass. The presentation will introduce a follow-on MEDLI instrumentation suite (called MEDLI2) that is being developed for Mars-2020 mission. MEDLI2 has an enhanced scope that includes backshell instrumentation, a wider forebody coverage, and instruments that specifically target supersonic aerodynamics. Similar to MEDLI, MEDLI2 uses thermal plugs with embedded thermocouples and ports through the TPS to measure surface pressure. MEDLI2, however, also includes heat flux sensors in the backshell and a low range pressure transducer to measure afterbody pressure.

Aerothermodynamics↗

Experiments on thermoacoustic convection heat transfer in gravity and zero-gravity environments

The results of an experimental study of thermoacoustic convection (TAC) heat transfer in gravity and zero-gravity environments are presented. The experimental apparatus consisted of a cylinder containing air as the compressible fluid. The enclosed air was heated electrically at the top surface which consisted of a thin high-resistance steel foil connected to a power source. Thermocouples were used to measure the transient temperature of the air on the axis of the cylinder and the heated surface in the both zero-gravity and gravity environments. The zero-gravity tests were performed in the Zero-Gravity Drop Tower Facility of NASA-Lewis Research Center. The experimental results were corrected for the error due to radiation absorption by the thermocouples. A conduction-only numerical heat transfer model was developed to compute the transient air temperature in the cylindrical geometry. The results were compared to the experimental data to determine the significance of the thermoacoustic convection heat transfer mechanism. It is observed that the rate of heat transfer to the air measured during the experiments is consistently higher than that obtained by the conduction-only solution indicating a significant presence of the TAC heat transfer. Further experiments are planned to measure directly (1) the radiative heat transfer contribution to the rise in the air temperature, and (2) the air pressure oscillations within the cylinder that are responsible for the convective heat transfer mode.

Parang, Masood↗

Observing Ice Sublimation From Water-Doped Lunar Simulant at Cryogenic Temperatures

NASA's Resource Prospector (RP) mission is intended to characterize the three-dimensional nature of volatiles in lunar polar and permanently shadowed regions. The Near-Infrared Volatile Spectrometer System (NIRVSS) observes while a drill penetrates to a maximum depth of 1 m. Any 10 cm increment of soil identified as containing water ice can be delivered to a heating crucible with the evolved gas delivered to a gas chromatograph / mass spectrometer. NIRVSS consists of two components; a spectrometer box (SB) and bracket assembly (BA), connected by two fiber optic cables. The SB contains separate short- and long-wavelength spectrometers, SW and LW respectively, that collectively span the 1600-3400 nm range. The BA contains an IR emitter (lamp), drill observation camera (DOC, 2048 x 2048 CMOS detector), 8 different wavelength LEDs, and a longwave calibration sensor (LCS) measuring the surface emissivity at four IR wavelengths. Tests of various RP sub-systems have been under-taken in a large cryo-vacuum chamber at Glenn Re-search Center. The chamber accommodates a tube (1.2 m high x 25.4 cm diameter) filled with lunar simulant, NU-LHT-3M, prepared with known abundances of water. Thermocouples are embedded at different depths, and also across the surface of the soil tube. In the chamber the tube is cooled with LN2 as the pressure is reduced to approx. 5-6x10(exp -6) Torr. For the May 2016 tests two soil tubes were prepared with initially 2.5 Wt.% water. The shroud surrounding the soil tube was held at different temperatures for each tube to simulate a warm and cold lunar environment. Table 1 provides a summary of experimental conditions and Figure 1 shows the nominal view of the NIRVSS components, the drill foot, and the top of the soil tube. Once the average soil temperature reached approx. 178 K, drilling commenced. During drilling activities NIRVSS was alternating between obtaining spectra and obtaining images. Here we discuss NIRVSS spectral data obtained during controlled drill percussions.

Roush, T. L.↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗

Analysis of PICA-NuSil at the Hypersonic Materials Environmental Test System (HyMETS)

Phenolic Impregnated Carbon Ablator (PICA) gained heritage during the stardust mission and is the baseline material for missions to Mars. The phenolic phase of PICA is friable, and therefore the surface is treated with a siloxane resin (NuSil) to mitigate the shedding of particulate matter. Historically, material response models have not accounted for the presence of this coating. Therefore, a test campaign was executed at the Hypersonic Materials Environmental Test System (HyMETS) to investigate the performance of NuSil under multiple heating rates and gas composition. Sphere-cone models were instrumented with thermocouples to measure the in-depth temperature response, and surface temperatures were monitored with a pyrometer. Furthermore, emission spectrometers were used to collect spectra from species emitting at the surface of the test article and the post-shock stagnation region. Post-test analysis suggests that the coating decomposes according to multiple stages. Inspection of silicon emission data reveals a rapid rise and decline in intensity within the first couple of seconds of testing, which is attributed to pyrolysis of NuSil. Pyrolysis is followed by a stagnation in silicon emission and surface temperature which are attributed to the formation of a thin layer of oxidation-resistant silicon oxycarbide. Moreover, the presence of the silicon oxycarbide layer significantly reduces the in-depth thermal response when compared to the baseline material. Eventually, the silicon oxycarbide layer decomposes via high-temperature reactions, which expose the underlying char layer to a highly reactive flow.

PICA-NuSil↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗