Empirical Insights for a Multi-Layered Network Complex Systems Model for Engineering Nuclear Security Systems-Slides.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Fermilab's homegrown fire and security system (known as FIRUS) is highly reliable and has been used nearly thirty years. The system has gone through some minor upgrades, however, none of those changes made significant, visible changes. In this paper, we present a major overhaul to the system that is halfway complete. We discuss the use of Apple's OS X for the new GUI, upgrading the servers to use the Erlang programming language and allowing limited access for iOS and Android-based mobile devices.
Information security continues to evolve in response to disruptive changes with a persistent focus on information-centric controls and a healthy debate about balancing endpoint and network protection, with a goal of improved enterprise/business risk management. Economic uncertainty, intensively collaborative styles of work, virtualization, increased outsourcing and ongoing complance pressures require careful consideration and adaption. The CSES provides a measure (i.e. a quantitative indication) of reliability, performance, and/or safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders' interests in that requirement. For a given stakeholder, CSES accounts for the variance that may exist among the stakes one attaches to meeting each requirement.
Securing the energy delivery system (EDS) from complex, nonlinear, and evolving cyber threats requires a complex set of changing and interwoven classes of technologies, policies, relationships, and personnel. One key area in this technological milieu is assessment methodologies to compare information, gathered by a variety of means, about networked devices with publicly known possible threat information about said devices. This information is used to generate risk-based characterizations that allow for the adjudication and proper corresponding management action chains to be assigned.
No abstract prepared.
The pending retirement of significant numbers of power system experts and a continuing trend of increasing complexity in modern power systems prompted the U.S. Department of Energy (DOE) to establish the three-phase Secure Power Systems Professional (SPSP) project. The project developed resources for job definition and competency analysis along with tools to guide assessment and curriculum design and to help identify and develop required knowledge, skills, and abilities in technical and operational aspects of power systems cybersecurity. The Secure Power Systems Professional Phase III final report was released last year which an appendix of Individual and Team Performance Guidelines. This new report is that appendix broken out as a standalone document to assist utilities in recruiting and developing Secure Power Systems Professionals at their site. Individual/Team Performance Guidelines were developed for each of the four job roles: the secure power systems engineer, incident responder, intrusion analyst, and security operator. They enable an “at-a-glance” view of the multidisciplinary and collaborative nature of SPSP job roles, for which skill sets were studied and then mapped to stories of critical incidents or vignettes. This afforded an enumeration of tasks required of each job role to effectively perform responsibilities and to meet bestpractice goals for that operation. Assignment of these tasks among the job roles, either as an individual responsibility or a collaborative responsibility, was validated during a job performance model analysis. The analysis identified 13 master vignettes from the collection of critical incident stories, many of which shared a common set of job responsibilities and tasks that were grouped into four vignette categories according to the task requirement for effective response to each event.
Typical questions surrounding industrial control system (ICS) cyber security always lead back to: What could a cyber attack do to my system(s) and; how much should I worry about it? These two leading questions represent only a fraction of questions asked when discussing cyber security as it applies to any program, company, business, or organization. The intent of this paper is to open a dialog of important pertinent questions and answers that managers of nuclear facilities engaged in nuclear facility security and safeguards should examine, i.e., what questions should be asked; and how do the answers affect an organization's ability to effectively safeguard and secure nuclear material. When a cyber intrusion is reported, what does that mean? Can an intrusion be detected or go un-noticed? Are nuclear security or safeguards systems potentially vulnerable? What about the digital systems employed in process monitoring, and international safeguards? Organizations expend considerable efforts to ensure that their facilities can maintain continuity of operations against physical threats. However, cyber threats particularly on ICSs may not be well known or understood, and often do not receive adequate attention. With the disclosure of the Stuxnet virus that has recently attacked nuclear infrastructure, many organizations have recognized the need for an urgent interest in cyber attacks and defenses against them. Several questions arise including discussions about the insider threat, adequate cyber protections, program readiness, encryption, and many more. These questions, among others, are discussed so as to raise the awareness and shed light on ways to protect nuclear facilities and materials against such attacks.
Security aspects of SCADA environments and the systems within are increasingly a center of interest to researchers and security professionals. As the rise of sophisticated and nation-state malware targeting such systems flourishes, traditional digital forensics tools struggle to transfer the same capabilities to systems lacking typical volatile memory primitives, monitoring software, and the compatible operating-system primitives necessary for conducting forensic investigations. Even worse, SCADA systems are typically not designed and implemented with security in mind, nor were they purpose-built to monitor and record system data at the granularity associated with traditional IT systems. Rather, these systems are often built to control field devices and drive industrial processes. More succinctly, SCADA systems were not designed with a primary goal of interacting with the digital world. Consequently, forensics investigators well-versed in the world of digital forensics and incident response face an array of challenges that prevent them from conducting effective forensic investigation in environments with vast amounts of critical infrastructure. In order to bring SCADA systems within the reach of the armies of digital forensics professionals and tooling already available, both researchers and practitioners need a guide to the current state-of-the-art techniques, a road-map to the challenges lying on the path forward, and insight into the future directions R&D must move towards. To that end, this paper presents a survey into the literature on digital forensics applied to SCADA systems. We cover not only the challenges to applying digital forensics to SCADA like most other reviews, but also the range of proposed frameworks, methodologies, and actual implementations in literature.
The Secure Power Systems Professional Phase III final report was released last year which an appendix of Behavioral Interview Guidelines by Job Roles. This new report is that appendix broken out as a standalone document to assist utilities in recruiting and developing Secure Power Systems Professionals at their site. The complete list of knowledge, skills, and abilities required in each of the studied job roles was assembled into the Behavioral Interview Guidelines. The guidelines were developed to apply the results of Phases I and II in a format that can be used in part or in whole to align workforce capabilities with the strategic goals and tactical focus of a power grid organization. These guidelines may 1) be applied to develop performance reviews or to produce individual professional development programs for existing staff; 2) assist in specifying learning objectives for a training or education program; and 3) be easily incorporated into most human capital software to facilitate development of job descriptions that comply with guidelines established by the Society of Human Resource Management. The guidelines can be immediately applied by human resources professionals, recruiters, and hiring managers to assist in recruiting and interviewing candidates for new SPSP position openings.
Secure and Resilient Cyber-physical Systems: Holistic Approaches to Critical Infrastructure Resilience Challenges Poster.
Information security continues to evolve in response to disruptive changes with a persistent focus on information-centric controls and a healthy debate about balancing endpoint and network protection, with a goal of improved enterprise/business risk management. Economic uncertainty, intensively collaborative styles of work, virtualization, increased outsourcing and ongoing compliance pressures require careful consideration and adaptation. The Cyberspace Security Econometrics System (CSES) provides a measure (i.e., a quantitative indication) of reliability, performance, and/or safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders interests in that requirement. For a given stakeholder, CSES accounts for the variance that may exist among the stakes one attaches to meeting each requirement. The basis, objectives and capabilities for the CSES including inputs/outputs as well as the structural and mathematical underpinnings contained in this copyright.
Security event data, such as intrusion detection system alerts, provide a starting point for analysis, but are information impoverished. To provide context, analysts must manually gather and synthesize relevant data from myriad sources within their enterprise and external to it. Analysts search system logs, network flows, and firewall data; they search IP blacklists and reputation lists, software vulnerability information, malware and threat data, OS and application vendor blogs, and news sites. All of these sources are manually searched for data relevant to the event being investigated. Relevant results must then be brought together and synthesized to put the event in context and make decisions about its importance and impact.
Computer-implemented security evaluation methods, security evaluation systems, and articles of manufacture are described. According to one aspect, a computer-implemented security evaluation method includes accessing information regarding a physical architecture and a cyber architecture of a facility, building a model of the facility comprising a plurality of physical areas of the physical architecture, a plurality of cyber areas of the cyber architecture, and a plurality of pathways between the physical areas and the cyber areas, identifying a target within the facility, executing the model a plurality of times to simulate a plurality of attacks against the target by an adversary traversing at least one of the areas in the physical domain and at least one of the areas in the cyber domain, and using results of the executing, providing information regarding a security risk of the facility with respect to the target.
This document provides the final report for the CYPRES project. The purpose is (1) to highlight and summarize its major accomplishments and (2) to provide guidance on how its outcomes have informed and can inform important additional research and technology transfer. The goal of CYPRES was the research, development, and demonstration of a security-oriented next generation cyber-physical EMS for electric power systems that detects malicious and abnormal events through the fusion of cyber and physical data. To achieve this, the CYPRES project team researched, developed, and built a prototype of the solution, referred to as the CYPRES EMS. The CYPRES EMS is a proof-of-concept cyber-physical platform that demonstrates the management of the energy system, communications, security, and cyber-physical grid modeling and analytics. As part of the capabilities of the CYPRES EMS, the team designed and developed a suite of power system applications for monitoring, risk analyses, detection, and control that are inherently cyberaware. At its core, the project aimed to research, develop, and demonstrate a security-oriented next-generation cyber-physical Energy Management System (EMS) capable of detecting malicious and abnormal events through the innovative fusion of cyber and physical data. This approach represents a fundamental shift from traditional EMS, reimagining how critical infrastructure can be protected through unified cyber-aware and physics-aware secure data flow pipelines. The project’s cornerstone deliverable, the CYPRES EMS, serves as a proof-of-concept cyber-physical platform that revolutionizes the management of energy systems, communications, security, and cyber-physical grid modeling and analytics. This prototype implements a comprehensive suite of power system applications for monitoring, risk analyses, detection, and control, all designed with inherent cyber awareness. The system’s architecture extends from end-devices in the field through to control center applications, establishing a secure and resilient control framework that addresses the challenges posed by diverse devices of unknown trustworthiness connecting to modern power systems. Through this innovative approach to deep cyber-physical situational awareness, the CYPRES project not only advances the state-of-the-art in energy infrastructure protection but also establishes a new paradigm for how EMS can be designed, deployed, and operated in an increasingly complex threat landscape. The findings and developments from this project provide crucial insights for stakeholders across the energy sector, offering a blueprint for enhancing the reliability and resilience of our nation’s critical energy infrastructure in the face of evolving cyber threats.
Schweitzer Engineering Laboratories (SEL) will conduct the Hallmark Project to address the need to reduce the risk of energy disruptions because of cyber incidents on control systems. The goals is to develop solutions that can be both applied to existing control systems and designed into new control systems to add the security measures needed to mitigate energy network vulnerabilities. The scope of the Hallmark Project contains four primary elements: 1. Technology transfer of the Secure Supervisory Control and Data Acquisition (SCADA) Communications Protocol (SSCP) from Pacific Northwest National Laboratories (PNNL) to Schweitzer Engineering Laboratories (SEL). The project shall use this technology to develop a Federal Information Processing Standard (FIPS) 140-2 compliant original equipment manufacturer (OEM) module to be called a Cryptographic Daughter Card (CDC) with the ability to directly connect to any PC enabling that computer to securely communicate across serial to field devices. Validate the OEM capabilities with another vendor. 2. Development of a Link Authenticator Module (LAM) using the FIPS 140-2 validated Secure SCADA Communications Protocol (SSCP) CDC module with a central management software kit. 3. Validation of the CDC and Link Authenticator modules via laboratory and field tests. 4. Creation of documents that record the impact of the Link Authenticator to the operators of control systems and on the control system itself. The information in the documents can assist others with technology deployment and maintenance.
Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensor s vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this mission. The test bed provides access to grassy fields, wooded areas, and a large waterway three distinct testing environments. The infrastructure supporting deployment of systems at the test bed includes grid power, renewable power systems, climate controlled enclosures, high bandwidth wireless links, and a fiber optic communications backbone. With over 10 acres of dedicated area and direct waterway access, the test bed is well suited for long term test and evaluation of physical protection and security systems targeting a wide range of applications.
Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only when the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.
Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn't lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identifies individual moving targets from the background imagery, and then displays the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.