Cu(Ir1-xCrx)(2)S-4: a model system for studying nanoscale phase coexistence at the metal-insulator transition
N/A
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
As the amount of renewable generation increases, the inherent variability of wind and photovoltaic systems must be addressed in order to ensure the continued safe and reliable operation of the nation’s electricity grid. Grid-scale energy storage systems are uniquely suited to address the variability of renewable generation and to provide other valuable grid services. The goal of this report is to quantify the technical performance required to provide different grid benefits and to specify the proper techniques for estimating the value of grid-scale energy storage systems.
Studying transformation in a chemical system by considering its energy as a function of coordinates of the system's components provides insight and changes our understanding of this process. Currently, a lack of effective visualization techniques for high-dimensional energy functions limits chemists to plot energy with respect to one or two coordinates at a time. In some complex systems, developing a comprehensive understanding requires new visualization techniques that show relationships between >all coordinates at the same time. We propose a new visualization technique that combines concepts from topological analysis, multi-dimensional scaling, and graph layout to enable the analysis of energy functions for a wide range of molecular structures. We demonstrate our technique by studying the energy function of a dimer of formic and acetic acids and a LTA zeolite structure, in which we consider diffusion of methane.
Numerical simulation is the key technique for large scale power system analysis. Redistribution of global renewable power via international interconnections requires new simulation tools to study the interconnected systems with different nominal frequencies as a whole. In this paper we introduce an open source simulation toolkit for electrical power systems (STEPS) which is hosted at Github. Its kernel is coded in C++ with major functions of power flow and electro-mechanical dynamic simulation. Flexible options are provided and configurable to improve power flow solution and dynamic simulation. Common devices and models are supported in STEPS for AC/DC hybrid system studies. Studies of interconnected systems with different nominal frequencies is supported in STEPS for research of international interconnection. Application program interfaces are provided and wrapped with Python to enable high-level interfaces for general applications. STEPS is thread safe and parallel computation is supported in both kernel and script levels to accelerate simulation. It is portable and works on Windows and GNU/Linux platforms. Cases from small to large scale systems are thoroughly tested to validate the toolkit with commercial packages as benchmarks.
In 2022, the National Energy Technology Laboratory published a techno-economic assessment (TEA) examining the performance and cost of a generic solid sorbent-based direct air capture (DAC) system, “Direct Air Capture Case Studies: Sorbent System”. Revision 1 of this report builds on the previous effort by updating assumptions to reflect the evolving industry and recent developments in the DAC research and development (R&D) portfolio. Revision 1 of the report also expands the case list to examine a variety of sorbent DAC system configurations. The objective of this series is to present transparent and independent TEAs that can serve as a guideline for sorbent DAC TEA development and highlight potential avenues for cost reductions that can inform R&D. The sorbent considered is not reflective of any one material type; rather, it represents an approximate average of reported material performance in the literature. The base cases presented in this series do not represent optimized systems due to the nascence of the technology and lack of publicly available information. The base cases serve as a reference for informative sensitivity analyses.
Systems suitable for the effective preparation of complexes with siRNA (small interfering RNA) are at the center of interest in the area of research work on the delivery of the RNA-based drugs (RNA-therapeutics). This article presents results of a study on the structural effects associated with siRNA complexation by a surfactant comprising a lactose group (N-(3-propanesulfone)-N-dodecyl-amino-beta-D-lactose hydrochloride, LA12). The double stranded siRNA oligomer (21 base pairs) used in this study is responsible for silencing a gene that can be important in the therapy of myotonic dystrophy type 1. The obtained siRNA/LA12 lipoplexes were studied using the methods of small angle scattering of synchrotron radiation, circular dichroism spectroscopy, Fourier transform infrared spectroscopy, and electrophoretic mobility tests. Lipoplexes form in solution stable lamellar or cubic phases. The surfactant selected for the study shows much lower cytotoxicity and good complexation abilities of siRNA than dicationic or polycationic surfactants.
Abstract not provided.
Abstract not provided.
Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.
Research on mycorrhizal symbiosis has been slowed by a lack of established study systems. To address this challenge, we have been developing Suillus, a widespread ecologically and economically relevant fungal genus primarily associated with the plant family Pinaceae, into a model system for studying ectomycorrhizal (ECM) associations. Over the last decade, we have compiled extensive genomic resources, culture libraries, a phenotype database, and protocols for manipulating Suillus fungi with and without their tree partners. Our efforts have already resulted in a large number of publicly available genomes, transcriptomes, and respective annotations, as well as advances in our understanding of mycorrhizal partner specificity and host communication, fungal and plant nutrition, environmental adaptation, soil nutrient cycling, interspecific competition, and biological invasions. Here, we highlight the most significant recent findings enabled by Suillus, present a suite of protocols for working with the genus, and discuss how Suillus is emerging as an important model to elucidate the ecology and evolution of ECM interactions.
4-Epi-oxytetracycline (4-EOTC), one of main oxytetracycline (OTC) metabolites, can be commonly detected in food and environment. The toxicity and effects of OTC on animals have been well characterized; however, its metabolites have never been studied systemically. This study aims to investigate 15-day oral dose toxicity and urine metabonomics changes of 4-EOTC after repeated administration in Wistar rats at daily doses of 0.5, 5.0 and 50.0 mg/kg bw (bodyweight). Hematology and clinical chemistry parameters, including white blood cell count, red blood cell count, total protein, globulin and albumin/globulin, were obviously altered in rats of 5.0 and 50.0 mg/kg bw. Histopathology changes of kidney and liver tissues were also observed in high-dose groups. Urinary metabolites from all groups were analyzed using ultra-high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MS). Seventeen metabolites contributing to the clusters were identified as potential biomarkers from multivariate analysis, including aminoadipic acid, 6-phosphogluconate, sebacic acid, pipecolic acid, etc. The significant changes of these biomarkers demonstrated metabonomic variations in treated rats, especially lysine and purine metabolism. For the first time in this paper, we combined the results of toxicity and metabonomics induced by 4-EOTC for the serious reconsideration of the safety and potential risks of antibiotics and its degradation metabolites. - Highlights: • 4-Epioxytetracycline (4-EOTC) induced damages in liver and kidney. • Metabonomics changes especially amino acid and purine metabolism were observed. • Security of OTC metabolite 4-EOTC should be taken into serious reconsideration.
Mixtures of perfluoropolyethers (PFPE) and lithium salts with fluorinated anions are a new class of electrolytes for lithium batteries. Unlike conventional electrolytes wherein electron-donating oxygen groups interact primarily with the lithium cations, the properties of PFPE-based electrolytes appear to be dependent on interactions between the fluorinated anions and the fluorinated backbones. We study these interactions by examining a family of lithium salts wherein the size of the fluorinated anion is systematically increased: lithium bis(fluorosulfonyl)imide (LiFSI), bis(trifluoromethanesulfonyl)imide (LiTFSI) salts and lithium bis(pentafluoroethanesulfonyl)imide (LiBETI). Two short chain perfluoroethers (PFE), one with three repeat units, C6-DMC, and another with four repeat units, C8-DMC were studied; both systems have dimethyl carbonate end groups.We find that LiFSI provides the highest conductivity in both C6-DMC and C8-DMC. These systems also present the lowest interfacial resistance against lithium metal electrodes. The steady-state transference number (t + ss ) was above 0.6 for all of the electrolytes and was an increasing function of anion size. The product of conductivity and the steady-state transference number, a convenient measure of the efficacy of the electrolytes for lithium battery applications, exhibited a maximum at about 20 wt% salt in all electrolytes. Finally, amongst the systems studied, LiFSI/PFE mixtures were the most efficacious electrolytes.
Simulation of smart grid technologies requires a fundamentally new approach to integrated modeling of power systems, energy markets, building technologies, and the plethora of other resources and assets that are becoming part of modern electricity production, delivery, and consumption systems. As a result, the US Department of Energy’s Office of Electricity commissioned the development of a new type of power system simulation tool called GridLAB-D that uses an agent-based approach to simulating smart grids. This paper presents the numerical methods and approach to time-series simulation used by GridLAB-D and reviews applications in power system studies, market design, building control system design, and integration of wind power in a smart grid.
This case study describes connected lighting system projects on two college campuses; Cal State Dominguez Hills and the University of Minnesota both implemented lighting and controls upgrades at mixed-use buildings, including advanced sensors, HVAC integration, and plug load control. Both projects were recognized by DOE's Integrated Lighting Campaign.
Explore the source record for details and available documents.
The process development, reactor scale-up, pilot-scale studies, and system modeling of copper-based chemical looping with oxygen uncoupling are presented.
Studies of room-to-room variations in radon levels in homes with individual room split systems have found significant variations in radon levels when compared to homes with central, forced air heating and air-conditioning systems.