Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Functional Independent Scaling Relation for ORR/OER Catalysts

A widely used adsorption energy scaling relation between OH* and OOH* intermediates in the oxygen reduction reaction (ORR) and oxygen evolution reaction (OER), has previously been determined using density functional theory and shown to dictate a minimum thermodynamic overpotential for both reactions. Here, we show that the oxygen–oxygen bond in the OOH* intermediate is, however, not well described with the previously used class of exchange-correlation functionals. By quantifying and correcting the systematic error, an improved description of gaseous peroxide species versus experimental data and a reduction in calculational uncertainty is obtained. For adsorbates, we find that the systematic error largely cancels the vdW interaction missing in the original determination of the scaling relation. An improved scaling relation, which is fully independent of the applied exchange–correlation functional, is obtained and found to differ by 0.1 eV from the original. Lastly, this largely confirms that, although obtained with a method suffering from systematic errors, the previously obtained scaling relation is applicable for predictions of catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A measurement of the Hubble constant from Type II supernovae

ABSTRACT Progressive increases in the precision of the Hubble-constant measurement via Cepheid-calibrated Type Ia supernovae (SNe Ia) have shown a discrepancy of ∼4.4σ with the current value inferred from Planck satellite measurements of the cosmic microwave background radiation and the standard $\Lambda $cold dark matter (ΛCDM) cosmological model. This disagreement does not appear to be due to known systematic errors and may therefore be hinting at new fundamental physics. Although all of the current techniques have their own merits, further improvement in constraining the Hubble constant requires the development of as many independent methods as possible. In this work, we use SNe II as standardisable candles to obtain an independent measurement of the Hubble constant. Using seven SNe II with host-galaxy distances measured from Cepheid variables or the tip of the red giant branch, we derive H$_0= 75.8^{+5.2}_{-4.9}$ km s−1 Mpc−1 (statistical errors only). Our value favours that obtained from the conventional distance ladder (Cepheids + SNe Ia) and exhibits a difference of 8.4 km s−1 Mpc−1 from the Planck + ΛCDM value. Adding an estimate of the systematic errors (2.8 km s−1 Mpc−1) changes the ∼1.7σ discrepancy with Planck +ΛCDM to ∼1.4σ. Including the systematic errors and performing a bootstrap simulation, we confirm that the local H0 value exceeds the value from the early Universe with a confidence level of 95 per cent. As in this work, we only exchange SNe II for SNe Ia to measure extragalactic distances, we demonstrate that there is no evidence that SNe Ia are the source of the H0 tension.

de Jaeger, T.↗

Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

Walter, Steven J.↗

Impact of systematic redshift errors on the cross-correlation of the Lyman-α forest with quasars at small scales using DESI Early Data

The Dark Energy Spectroscopic Instrument (DESI) will measure millions of quasar spectra by the end of its 5 year survey. Quasar redshift errors impact the shape of the Lyman-α forest correlation functions, which can affect cosmological analyses and therefore cosmological interpretations. Here, using data from the DESI Early Data Release and the first two months of the main survey, we measure the systematic redshift error from an offset in the cross-correlation of the Lyman-α forest with quasars. We find evidence for a redshift dependent bias causing redshifts to be underestimated with increasing redshift, stemming from improper modeling of the Lyman-α optical depth in the templates used for redshift estimation. New templates were derived for the DESI Year 1 quasar sample at z > 1.6 and we found the redshift dependent bias, Δr ∥ , increased from -1.94 ± 0.15 h -1 Mpc to -0.08 ± 0.04 h -1 Mpc (-205 ± 15 km s -1 to -9.0 ± 4.0 km s -1 ). These new templates will be used to provide redshifts for the DESI Year 1 quasar sample.

Lyman alpha forest↗

Bayesian Cross-matching of High Proper-motion Stars in Gaia DR2 and Photometric Metallicities for ∼1.7 million K and M Dwarfs

We present a Bayesian method to cross-match 5,827,988 high proper-motion Gaia sources (μ > 40 mas yr{sup −1}) to various photometric surveys: Two Micron All Sky Survey, AllWISE data release from the Wide-field Infrared Explorer (WISE) mission, Galaxy Evolution Explorer, Radial Velocity Experiment, Sloan Digital Sky Survey, and Panoramic Survey Telescope and Rapid Response System (Pan-STARRS). To efficiently associate these objects across catalogs, we develop a technique that compares the multidimensional distribution of all sources in the vicinity of each Gaia star to a reference distribution of random field stars obtained by extracting all sources in a region on the sky displaced 2′. This offset preserves the local field stellar density and magnitude distribution, allowing us to characterize the frequency of chance alignments. The resulting catalog with Bayesian probabilities >95% has a marginally higher match rate than current internal Gaia data release 2 (DR2) matches for most catalogs. However, a significant improvement is found with Pan-STARRS, where ∼99.8% of the sample within the Pan-STARRS footprint is recovered, as compared to a low ∼20.8% in Gaia DR2. Using these results, we train a Gaussian process regressor to calibrate two photometric metallicity relationships. For dwarfs of 3500 < T{sub eff} < 5280 K, we use metallicity values of 4378 stars from the Apache Point Observatory Galactic Evolution Experiment and Hejazi et al. to calibrate the relationship, producing results with a 1σ precision of 0.12 dex and few systematic errors. We then indirectly infer the metallicity of 4018 stars with 2850 < T{sub eff} < 3500 K, which are wide companions of primaries whose metallicities are estimated with our first regressor, to produce a relationship with a 1σ precision of 0.21 dex and significant systematic errors. Additional work is needed to better remove unresolved binaries from this second sample to reduce these systematic errors.

47 OTHER INSTRUMENTATION↗

Sky Residual Correction

The near-infrared is populated by numerous emission lines radiated from the Earth’s atmosphere, and these emission lines are often several orders of magnitude brighter in intensity than the typical astrophysical science target. The subtraction of these emission lines, sky subtraction, can create large systematic errors in ground-based astronomical spectra effectively limiting the number of usable resolution elements. A more effective sky subtraction, and the reduction of the systematic errors due to the sky subtraction process, is a major hurdle which ground-based astronomy must overcome to increase the amount of usable spectrum, and to be able to observe fainter scientific targets. Large high-quality data sets such as the Sloan Digital Sky Survey (SDSS) in themselves present opportunities for a reduction of the systematic sky subtraction errors through self-calibration. The sky residual correction method of Wild and Hewett is one such self-calibration technique which uses principal component analysis to reduce the systematic sky residual errors present in SDSS spectra. We apply sky residual corrections to the SDSS, Baryon Oscillation Spectroscopic Survey, and Apache Point Observatory Galactic Evolution Experiment data sets to optimize the number of subtraction components, and to quantify the reduction of the systematic errors in the science spectra. Finally as a proof of concept we use the sky-residual-corrected SDSS luminous red galaxy spectra to search for gravitationally lensed emission line Galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Stitching interferometry for ellipsoidal x-ray mirrors

Ellipsoidal mirrors, which can efficiently produce a two-dimensional focusing beam with a single mirror, are superior x-ray focusing optics, especially when compared to elliptical-cylinder mirrors in the Kirkpatrick–Baez geometry. However, nano-focusing ellipsoidal mirrors are not commonly used for x-ray optics because achieving the accuracy required for the surface metrology of nano-focusing ellipsoidal mirrors is difficult due to their small radius of curvature along the short ellipsoidal axis. Here, we developed a surface metrology system for nano-focusing ellipsoidal mirrors using stitching interferometric techniques. The developed system simultaneously measures sub-aperture shapes with a microscopic interferometer and the tilt angles of the sub-aperture shapes with a large Fizeau interferometer. After correcting the systematic errors included in the sub-aperture shapes, the entire mirror shape is calculated by stitching the sub-aperture shapes based on the obtained relative angles between partially overlapped sub-apertures. In this study, we developed correction methods for systematic errors in sub-aperture shapes that originated from off-axis aberrations produced in the optics of the microscopic interferometer. The systematic errors on an ellipsoidal mirror were estimated by measuring a series of tilted plane substrates and the ellipsoidal substrate. From measurements of an ellipsoidal mirror with a 3.6-mm radius of curvature at the mirror center, we obtained a measurement repeatability of 0.51 nm (root-mean-square) in an assessment area of 0.5 mm × 99.18 mm. This value satisfies the requirements for surface metrology of nano-focusing x-ray mirrors. Thus, the developed metrology system should be applicable for fabricating nano-focusing ellipsoidal mirrors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filtering Methods for Error Reduction in Spacecraft Attitude Estimation Using Quaternion Star Trackers

Precision attitude determination for recent and planned space missions typically includes quaternion star trackers (ST) and a three-axis inertial reference unit (IRU). Sensor selection is based on estimates of knowledge accuracy attainable from a Kalman filter (KF), which provides the optimal solution for the case of linear dynamics with measurement and process errors characterized by random Gaussian noise with white spectrum. Non-Gaussian systematic errors in quaternion STs are often quite large and have an unpredictable time-varying nature, particularly when used in non-inertial pointing applications. Two filtering methods are proposed to reduce the attitude estimation error resulting from ST systematic errors, 1) extended Kalman filter (EKF) augmented with Markov states, 2) Unscented Kalman filter (UKF) with a periodic measurement model. Realistic assessments of the attitude estimation performance gains are demonstrated with both simulation and flight telemetry data from the Lunar Reconnaissance Orbiter.

Calhoun, Philip C.↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing precision and accuracy in PDV results

We need to know uncertainties and systematic errors because we create and compare against archival weapons data, we constrain the models, and we provide scientific results. Good estimates of precision from the data record are available and should be incorporated into existing results; reanalysis of valuable data is suggested. Estimates of systematic errors are largely absent. The original work by Jensen et al. using gun shots for window corrections, and the integrated velocity comparison with X-rays by Schultz are two examples where any systematic errors appear to be <1% level.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The QUIET Instrument

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ( approx 1 deg.) . Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 micro Ks(exp 1/2)) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 micro Ks(exp 1/2) at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01 (QUIET Collaboration 2012) The two arrays together cover multipoles in the range l approximately equals 25-975 . These are the largest HEMT-ba.sed arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument,

Gaier, T.↗

An Investigation Into Possible Systematic Effects on Neutron Star Radius Estimates using NICER-like Synthetic Data

Neutron star cores contain the densest matter in the observable universe. The state of this matter is of interest in numerous fields, but laboratory experiments cannot explore this matter. Although the composition of the matter would be of great interest, macroscopic observables such as the neutron star mass-radius relation depend primarily on the equation of state (EOS). As a result, precise and reliable radius measurements would be valuable in constraining the EOS. However, most attempts at radius measurements are susceptible to systematic errors, meaning the inferred radius can be significantly biased even though the fit to the data appears to be statistically good. Previous studies suggested that radii inferred using X-ray data provided by NASA’s NICER mission may be more immune from such systematic errors. This is in part because, compared with previous measurements that obtained averaged spectra and fluxes, NICER observes millisecond pulsars by timing the photons so precisely, it is possible to obtain the spectrum as a function of rotational phase and see variations such as heated regions on the star rotate into and out of view hundreds of times per second. This extra information seems promising to break degeneracies and mitigate systematic errors, but a more in-depth study is necessary. We report the first steps of that study, in which we generate NICER-like synthetic data and determine the quality of fit and bias in radius obtained when we fit the data using a model different from the model used to generate the data.

Isiah Holt↗

Reanalysis of X-ray emission from M87. 2: The multiphase medium

In a previous paper, we showed that a single-phase model for the gas around M87 simultaneously explained most available X-ray data. Total enclosed masses derived from the model, however, fell well below the determinations from optical measurements. In this paper, we consider possible solutions to the inconsistency, including two multiphase medium models for the gas and the consequences of systematic errors of the Einstein Focal Point Crystal Spectrometer (FPCS). First, we find that when constraints from optical mass determinations are not considered, the best-fit model to the X-ray data is always the single-phase model. Multiphase models or consideration of FPCS systematic errors are required only when optical mass constraints are included. We find that the cooling time model of White & Sarazin adequately explains the available X-ray data and predicts total masses which agree with optical measurements. An ad hoc power-law multiphase does not. This shows both that the existence of mass dropping out of the ambient phase is consistent with the data and that the cooling-time model gives a reasonable parameterization of the dropout rate. Our derived mass accretion rate is similar to previous determinations. The implications of this result for cluster mass determinations in general are discussed. We then consider 'self absorbing' models where we assume that material dropping out of the ambient medium goes completely into X-ray absorbing gas. The resulting internal absorption is small compared to Galactic absorption at most radii. The models are therefore indistinguishable from models with only Galactic absorption. We finally show that it is alternatively possible to simultaneously fit optical mass measurements and X-ray data with a single-phase model if some of the observed FPCS line fluxes are too high by the maximum systematic error. This possiblity can be checked with new data from satellites such as ASCA.

Tsai, John C.↗

Evaluation of NMME temperature and precipitation bias and forecast skill for South Asia

Systematic error and forecast skill for temperature and precipitation in two regions of Southern Asia are investigated using hindcasts initialized May 1 from the North American Multi-Model Ensemble. We focus on two contiguous but geographically and dynamically diverse regions: the Extended Indian Monsoon Rainfall (70–100E, 10–30 N) and the nearby mountainous area of Pakistan and Afghanistan (60–75E, 23–39 N). Forecast skill is assessed using the Sign test framework, a rigorous statistical method that can be applied to non-Gaussian variables such as precipitation and to different ensemble sizes without introducing bias. We find that models show significant systematic error in both precipitation and temperature for both regions. The multi-model ensemble mean (MMEM) consistently yields the lowest systematic error and the highest forecast skill for both regions and variables. However, we also find that the MMEM consistently provides a statistically significant increase in skill over climatology only in the first month of the forecast. While the MMEM tends to provide higher overall skill than climatology later in the forecast, the differences are not significant at the 95% level. We also find that MMEMs constructed with a relatively small number of ensemble members per model can equal or outperform MMEMs constructed with more members in skill. This suggests some ensemble members either provide no contribution to overall skill or even detract from it.

54 ENVIRONMENTAL SCIENCES↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Baryon acoustic oscillation theory and modelling systematics for the DESI 2024 results

This paper provides a comprehensive overview of how fitting of baryon acoustic oscillations (BAO) is carried out within the upcoming Dark Energy Spectroscopic Instrument’s (DESI) 2024 results using its DR1 data set, and the associated systematic error budget from theory and modelling of the BAO. We derive new results showing how non-linearities in the clustering of galaxies can cause potential biases in measurements of the isotropic (⁠α iso ⁠) and anisotropic (⁠α ap ) BAO distance scales, and how these can be effectively removed with an appropriate choice of reconstruction algorithm. We then demonstrate how theory leads to a clear choice for how to model the BAO and develop, implement, and validate a new model for the remaining smooth-broad-band (i.e. without BAO) component of the galaxy clustering. Finally, we explore the impact of all remaining modelling choices on the BAO constraints from DESI using a suite of high-precision simulations, arriving at a set of best practices for DESI BAO fits, and an associated theory and modelling systematic error. Overall, our results demonstrate the remarkable robustness of the BAO to all our modelling choices and motivate a combined theory and modelling systematic error contribution to the post-reconstruction DESI BAO measurements of no more than 0.1 per cent (0.2 per cent) for its isotropic (anisotropic) distance measurements. We expect the theory and best practices laid out to here to be applicable to other BAO experiments in the era of DESI and beyond.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying Multi-Frequency AC LOCO for Finding Sextupole Errors

A fast and precise technique of multi-frequency AC LOCO has been developed and tested for finding the sextupole alignment and field-offset errors at NSLS-II. This technique is based on sine-wave beam excitation simultaneously at multiple frequencies via different fast correctors. The unique combination of the fast speed and high measurement accuracy opens the door for two different types of potential applications: finding the sextupole alignment and field-offset errors. Beam excitation via fast correctors results in the elimination of the systematic error caused by the hysteresis effect. Systematic errors of the sextupole alignment caused by orbit drift and power supply calibration are also eliminated because the measurement takes only two minutes and does not depend on the current-to-field conversion of sextupole magnets. Furthermore, the simulation studies indicate that multi-frequency AC LOCO together with an orbit bump bigger than 0.5 mm can be applied to measure the relative field offset of a sextupole magnet with a precision better than 10%. The measurement technique is described and the results of two proof-of-principle experiments carried out at NSLS-II are presented.

43 PARTICLE ACCELERATORS↗