Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Non-Systematic Errors of Monthly Oceanic Rainfall Derived From TMI

A major objective of the Tropical Rainfall Measuring Mission (TRMM) is to produce a multi-year time series of monthly rainfall over 50 latitude by 50 longitude boxes with an uncertainty of 1 mm/day for low rain rates and 10% for high rain rates. Based on some simple assumptions about the error structure, we compute the non-systematic errors of monthly oceanic rainfall over the same space/time domain derived from data taken by the Special Sensor Microwave Imager (SSM/I) on board the Defense Meteorological Satellite Program (DMSP) satellites and TRMM Microwave Imager (TMI). The mean rain rates over a two-year period (1998-1999) are calculated to be 3.0, 2.85, 2.94 mm/day for SSM/I onboard the DMSP F-13, F-14 and TMI, respectively. Assuming that the non-systematic errors for each sensor are independent, the errors are calculated to be 22.2%, 22.4% and 19.7% for F-13, F-14 and for TMI, respectively. The non-systematic error for the TMI is smaller than that for either F-13 or F-14 SSM/I at the low rain rates but is comparable at rain rates higher than about 5 mm/day. The TRMM objective of 1 mm/day for non-systematic error is met by TMI for rain rates up to 5-6 mm/day. For higher rain rates, the nonsystematic error is in the 15% range. The goal of a 10% error for high rain rates may be realized by a combination of sensor measurements from multiple satellites, such as that advocated by the Global Precipitation Mission (GPM).

Chiu, Long S.↗

First Year Wilkinson Microwave Anisotropy Probe(WMAP) Observations: Data Processing Methods and Systematic Errors Limits

We describe the calibration and data processing methods used to generate full-sky maps of the cosmic microwave background (CMB) from the first year of Wilkinson Microwave Anisotropy Probe (WMAP) observations. Detailed limits on residual systematic errors are assigned based largely on analyses of the flight data supplemented, where necessary, with results from ground tests. The data are calibrated in flight using the dipole modulation of the CMB due to the observatory's motion around the Sun. This constitutes a full-beam calibration source. An iterative algorithm simultaneously fits the time-ordered data to obtain calibration parameters and pixelized sky map temperatures. The noise properties are determined by analyzing the time-ordered data with this sky signal estimate subtracted. Based on this, we apply a pre-whitening filter to the time-ordered data to remove a low level of l/f noise. We infer and correct for a small (approx. 1 %) transmission imbalance between the two sky inputs to each differential radiometer, and we subtract a small sidelobe correction from the 23 GHz (K band) map prior to further analysis. No other systematic error corrections are applied to the data. Calibration and baseline artifacts, including the response to environmental perturbations, are negligible. Systematic uncertainties are comparable to statistical uncertainties in the characterization of the beam response. Both are accounted for in the covariance matrix of the window function and are propagated to uncertainties in the final power spectrum. We characterize the combined upper limits to residual systematic uncertainties through the pixel covariance matrix.

Hinshaw, G.↗

The Effect of Systematic Error in Forced Oscillation Testing

One of the fundamental problems in flight dynamics is the formulation of aerodynamic forces and moments acting on an aircraft in arbitrary motion. Classically, conventional stability derivatives are used for the representation of aerodynamic loads in the aircraft equations of motion. However, for modern aircraft with highly nonlinear and unsteady aerodynamic characteristics undergoing maneuvers at high angle of attack and/or angular rates the conventional stability derivative model is no longer valid. Attempts to formulate aerodynamic model equations with unsteady terms are based on several different wind tunnel techniques: for example, captive, wind tunnel single degree-of-freedom, and wind tunnel free-flying techniques. One of the most common techniques is forced oscillation testing. However, the forced oscillation testing method does not address the systematic and systematic correlation errors from the test apparatus that cause inconsistencies in the measured oscillatory stability derivatives. The primary objective of this study is to identify the possible sources and magnitude of systematic error in representative dynamic test apparatuses. Sensitivities of the longitudinal stability derivatives to systematic errors are computed, using a high fidelity simulation of a forced oscillation test rig, and assessed using both Design of Experiments and Monte Carlo methods.

Williams, Brianne Y.↗

A Practical Methodology for Quantifying Random and Systematic Components of Unexplained Variance in a Wind Tunnel

This paper documents a check standard wind tunnel test conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3M TCT) that was designed and analyzed using the Modern Design of Experiments (MDOE). The test designed to partition the unexplained variance of typical wind tunnel data samples into two constituent components, one attributable to ordinary random error, and one attributable to systematic error induced by covariate effects. Covariate effects in wind tunnel testing are discussed, with examples. The impact of systematic (non-random) unexplained variance on the statistical independence of sequential measurements is reviewed. The corresponding correlation among experimental errors is discussed, as is the impact of such correlation on experimental results generally. The specific experiment documented herein was organized as a formal test for the presence of unexplained variance in representative samples of wind tunnel data, in order to quantify the frequency with which such systematic error was detected, and its magnitude relative to ordinary random error. Levels of systematic and random error reported here are representative of those quantified in other facilities, as cited in the references.

Deloach, Richard↗

Marginalizing Instrument Systematics in HST WFC3 Transit Light Curves

Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) infrared observations at 1.1-1.7 microns probe primarily the H2O absorption band at 1.4 microns, and have provided low-resolution transmission spectra for a wide range of exoplanets. We present the application of marginalization based on Gibson to analyze exoplanet transit light curves obtained from HST WFC3 to better determine important transit parameters such as "ramp" probability (R (sub p)) divided by "ramp" total (R (sub asterisk)), which are important for accurate detections of H2O. We approximate the evidence, often referred to as the marginal likelihood, for a grid of systematic models using the Akaike Information Criterion. We then calculate the evidence-based weight assigned to each systematic model and use the information from all tested models to calculate the final marginalized transit parameters for both the band-integrated and spectroscopic light curves to construct the transmission spectrum. We find that a majority of the highest weight models contain a correction for a linear trend in time as well as corrections related to HST orbital phase. We additionally test the dependence on the shift in spectral wavelength position over the course of the observations and find that spectroscopic wavelength shifts delta (sub lambda) times lambda) best describe the associated systematic in the spectroscopic light curves for most targets while fast scan rate observations of bright targets require an additional level of processing to produce a robust transmission spectrum. The use of marginalization allows for transparent interpretation and understanding of the instrument and the impact of each systematic evaluated statistically for each data set, expanding the ability to make true and comprehensive comparisons between exoplanet atmospheres.

Wakeford, H. R.↗

Revisiting Grodzins systematics of B(E2) values

Using Grodzins formalism, we analyze systematics of our latest evaluated B(E2) data for all the even–even nuclei in Z=2–104. The analysis indicates a low predictive power of systematics for a large number of cases, and a strong correlation between B(E2) fit values and nuclear structure effects. These findings provide a strong rationale for introduction of individual or elemental (grouped by Z) fit parameters. The current estimates of quadrupole collectivities for systematics of even–even nuclei yield complementary values for comparison with experimental results and theoretical calculations. Furthermore, the lists of fit parameters and predicted B(E2) values are given and possible implications are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic quark/gluon identification with ratios of likelihoods

Discriminating between quark- and gluon-initiated jets has long been a central focus of jet substructure, leading to the introduction of numerous observables and calculations to high perturbative accuracy. At the same time, there have been many attempts to fully exploit the jet radiation pattern using tools from statistics and machine learning. We propose a new approach that combines a deep analytic understanding of jet substructure with the optimality promised by machine learning and statistics. After specifying an approximation to the full emission phase space, we show how to construct the optimal observable for a given classification task. This procedure is demonstrated for the case of quark and gluons jets, where we show how to systematically capture sub-eikonal corrections in the splitting functions, and prove that linear combinations of weighted multiplicity is the optimal observable. In addition to providing a new and powerful framework for systematically improving jet substructure observables, we demonstrate the performance of several quark versus gluon jet tagging observables in parton-level Monte Carlo simulations, and find that they perform at or near the level of a deep neural network classifier. Combined with the rapid recent progress in the development of higher order parton showers, we believe that our approach provides a basis for systematically exploiting subleading effects in jet substructure analyses at the Large Hadron Collider (LHC) and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cadmium isotope systematics in sedimentary carbonate: Extending the utility of the cadmium isotope palaeo-productivity proxy

The cadmium (Cd) isotope compositions of seven Holocene (<11.7 ka) carbonate sediments, including the bulk carbonate, as well as the > 140 μm (zooplankton), <63 μm and < 20 μm (phytoplankton) fractions, and individual species of foraminifera isolated from the bulk carbonate were obtained for sub-samples processed using the Cd-cleaning and Mg/Ca cleaning methods. The respective Cd isotope systematics of each carbonate archive were then compared with the Cd isotope signature within the ocean using modern seawater data. We show that a constant Cd isotope fractionation factor of -0.25 ± 0.03 ‰ (2SE, n = 4) describes the partitioning of Cd from seawater into the carbonate phase ($Δ^{114}Cd_{CdC O_3 - seawater}$), allowing for accurate reconstructions of the past seawater nutrient regime. The Cd isotope signature of the < 63 µm and < 20 µm (phytoplankton) fractions can display comparable values to those recorded in the modern surface ocean, and can be used to model the magnitude of Cd uptake and utilisation in the past ocean. Individual species of planktic and benthic foraminifera, which inhabit different depths of the water column, can provide a full surface to deep water column reconstruction of the Cd nutrient regime, while infaunal benthic foraminifera can be used to interrogate the Cd isotope systematics of sediment porewaters. Bulk sediment and the > 140 µm (zooplankton) fraction also retain important information relating to the overlying water column Cd isotope systematics and can serve as essential archives for palaeo-productivity reconstructions where the separation of individual components from the bulk sediment is not possible. This new Cd isotope palaeo-productivity toolkit can considerably aid reconstruction efforts and vastly improves the ability to quantify the role of phytoplankton in modulating carbon sequestration through transitions in Earth’s climate evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Curative Treatment of Stage I Non-Small-Cell Lung Cancer in Patients With Severe COPD: Stereotactic Radiotherapy Outcomes and Systematic Review

Objectives: Patients with severe chronic obstructive pulmonary disease (COPD) have a high risk of lung cancer and of postsurgical complications. We studied outcomes after stereotactic body radiotherapy (SBRT) in patients with severe COPD, as defined by Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria, and performed a systematic review of the literature on outcomes after SBRT or surgery in these patients. Methods: A single-institution cohort of 176 patients with COPD GOLD III-IV and Stage I non-small-cell lung cancer (NSCLC) treated with SBRT was evaluated. A systematic review identified studies reporting outcomes after SBRT or surgery for Stage I NSCLC in patients with GOLD III-IV or a predicted postoperative forced expiratory volume in 1 second (FEV1) of {<=}40%. Results: In the single-institution cohort, median follow-up was 21 months and median overall survival (OS) was 32 months. Actuarial 3-year local control was 89%, and 1- and 3-year OS were 79% and 47%, respectively. COPD severity correlated with OS (p = 0.01). The systematic review identified four other studies (two surgical, two SBRT, n = 196 patients). SBRT studies were published more recently and included older patients than surgical studies. Mean 30-day mortality was 0% post-SBRT and 10% after surgery. Local or locoregional control was high ({>=}89%) after both treatments. Post-SBRT, actuarial OS was 79-95% at 1 year and 43-70% at 3 years. Postsurgical actuarial OS was 45-86% at 1 year and 31-66% at 3 years. Conclusions: SBRT and surgery differ in risk of 30-day mortality in patients with severe COPD. Despite the negative selection of SBRT patients, survival at 1 and 3 years is comparable between the two treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charged Particle Radiation Therapy for Uveal Melanoma: A Systematic Review and Meta-Analysis

Charged particle therapy (CPT) delivered with either protons, helium ions, or carbon ions, has been used to treat uveal melanoma. The present analysis was performed to systematically evaluate the efficacy and adverse effects of CPT for uveal melanoma. We searched EMBASE, MEDLINE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and SciVerse Scopus and cross-referenced recent systematic reviews through January 2012. Two independent reviewers identified clinical trials and observational studies of CPT (protons, helium ions, and carbon ions). These reviewers extracted data and assessed study quality. Twenty-seven studies enrolling 8809 uveal melanoma patients met inclusion criteria. The rate of local recurrence was significantly less with CPT than with brachytherapy (odds ratio [OR] = 0.22, 95% confidence interval [CI], 0.21-0.23). There were no significant differences in mortality or enucleation rates. Results were robust in multiple sensitivity analyses. CPT was also associated with lower retinopathy and cataract formation rates. Data suggest better outcomes may be possible with charged particle therapy with respect to local recurrence, retinopathy, and cataract formation rates. The overall quality of the evidence is low, and higher quality comparative effectiveness studies are needed to provide better evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence of Listeria monocytogenes , Salmonella spp., Shiga toxin-producing Escherichia coli , and Campylobacter spp. in raw milk in the United States between 2000 and 2019: A systematic review and meta-analysis

Raw (unpasteurized) milk is available for sale and direct human consumption within some states in the United States (US); it cannot be sold or distributed in interstate commerce. Raw milk may contain pathogenic microorganisms that, when consumed, may cause illness and sometimes may result in death. No comprehensive review for prevalence and levels of the major bacterial pathogens in raw milk in the US exists. The objective of the present research was to systematically review the scientific literature published from 2000 to 2019 to estimate the prevalence and levels of Listeria monocytogenes, Salmonella spp., Shiga toxin-producing Escherichia coli (STEC), and Campylobacter spp. in raw milk in the US. Peer-reviewed studies were retrieved systematically from PubMed®, Embase®, and Web of ScienceTM. The unique complete nonduplicate references were uploaded into the Health Assessment Work Collaborative (HAWC). Based on the selection criteria, twenty studies were included in the systematic review and meta-analysis. Comprehensive Meta-Analysis (CMA) was used for statistical analyses, specifically, random effects meta-analyses were used to synthesize raw bulk tank milk (BTM) and milk filters (MF) data. Data from studies using culture and non–culture-based detection methods were included. Forest plots generated in CMA (Biostat, Englewood, NJ) were used to visualize the results. The average prevalence (event rate) of L. monocytogenes, Salmonella spp., STEC, and Campylobacter spp. in raw BTM in the US was estimated at 4.3% (95% confidence intervals [CIs], 2.8–6.5%), 3.6% (95% CIs, 2.0–6.2%), 4.3% (95% CIs, 2.4–7.4%), and 6.0% (95% CIs, 3.2–10.9%), respectively. Estimated prevalence was generally larger in MF than in BTM. There was not enough data to perform a meta-analysis for the prevalence or levels of pathogens in raw milk from retail establishments or other milk categories.

60 APPLIED LIFE SCIENCES↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of MCNP ® 6 implicit-capture simulations for quantification of systematic uncertainties from experimental environments

In this study, the high statistical precision that can be achieved using modern data collection techniques implies that systematic uncertainties that were ignored or not considered for past experiments must now be explored. The folding of Monte Carlo simulations into experimental data analysis, which is becoming common practice, requires an estimate of the systematic uncertainty present in the experimental result from uncertainties in the library of cross sections used during the simulation, but this source of uncertainty is typically not quantified. Here we describe a method to estimate this systematic uncertainty by varying the cross sections used during simulation runtime. As opposed carrying out hundreds of sequential analog Monte Carlo simulations, this task was accomplished through a post-processing calculation of output from a single simulation that was run using the implicit-capture formalism available with MCNP ® 6.2 and the PTRAC output format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic characterization of human gut microbiome-secreted molecules by integrated multi-omics

The human gut microbiome produces a complex mixture of biomolecules that interact with human physiology and play essential roles in health and disease. Crosstalk between micro-organisms and host cells is enabled by different direct contacts, but also by the export of molecules through secretion systems and extracellular vesicles. The resulting molecular network, comprised of various biomolecular moieties, has so far eluded systematic study. Here we present a methodological framework, optimized for the extraction of the microbiome-derived, extracellular biomolecular complement, including nucleic acids, (poly)peptides, and metabolites, from flash-frozen stool samples of healthy human individuals. Our method allows simultaneous isolation of individual biomolecular fractions from the same original stool sample, followed by specialized omic analyses. The resulting multi-omics data enable coherent data integration for the systematic characterization of this molecular complex. Our results demonstrate the distinctiveness of the different extracellular biomolecular fractions, both in terms of their taxonomic and functional composition. This highlights the challenge of inferring the extracellular biomolecular complement of the gut microbiome based on single-omic data. The developed methodological framework provides the foundation for systematically investigating mechanistic links between microbiome-secreted molecules, including those that are typically vesicle-associated, and their impact on host physiology in health and disease.

59 BASIC BIOLOGICAL SCIENCES↗

Planck 2013 results. III. LFI systematic uncertainties

We present the current estimate of instrumental and systematic effect uncertainties for the Planck -Low Frequency Instrument relevant to the first release of the Planck cosmological results. Here, we give an overview of the main effects and of the tools and methods applied to assess residuals in maps and power spectra. We also present an overall budget of known systematic effect uncertainties, which are dominated by sidelobe straylight pick-up and imperfect calibration. However, even these two effects are at least two orders of magnitude weaker than the cosmic microwave background fluctuations as measured in terms of the angular temperature power spectrum. A residual signal above the noise level is present in the multipole range &ell; < 20, most notably at 30 GHz, and is probably caused by residual Galactic straylight contamination. Current analysis aims to further reduce the level of spurious signals in the data and to improve the systematic effects modelling, in particular with respect to straylight and calibration uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

J-PLUS: Systematic impact of metallicity on photometric calibration with the stellar locus

Here, we present the photometric calibration of the twelve optical passbands for the Javalambre Photometric Local Universe Survey (J-PLUS) second data release (DR2), comprising 1088 pointings of two square degrees, and study the systematic impact of metallicity on the stellar locus technique. The [Fe/H] metallicity from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) for 146 184 high-quality calibration stars, defined with signal-to-noise ratio larger than ten in J-PLUS passbands and larger than three in Gaia parallax, was used to compute the metallicity-dependent stellar locus (ZSL). The initial homogenization of J-PLUS photometry, performed with a unique stellar locus, was refined by including the metallicity effect in colors via the ZSL. The variation of the average metallicity along the Milky Way produces a systematic offset in J-PLUS calibration. This effect is well above 1% for the bluer passbands and amounts 0.07, 0.07, 0.05, 0.03, and 0.02 mag in u, J0378, J0395, J0410, and J0430, respectively. We modeled this effect with the Milky Way location of the J-PLUS pointing, also providing an updated calibration for those observations without LAMOST information. The estimated accuracy in the calibration after including the metallicity effect is at 1% for the bluer J-PLUS passbands and below for the rest. Photometric calibration with the stellar locus technique is prone to significant systematic bias in the Milky Way for passbands bluer than λ = 4500 Å. The calibration method for J-PLUS DR2 reaches 1–2% precision and 1% accuracy for 12 optical filters within an area of 2176 square degrees.

79 ASTRONOMY AND ASTROPHYSICS↗

TDCOSMO VIII. A key test of systematics in the hierarchical method of time-delay cosmography

The largest source of systematic errors in the time-delay cosmography method likely arises from the lens model mass distribution, where an inaccurate choice of model could in principle bias the value of $H$ 0 . A Bayesian hierarchical framework has been proposed which combines lens systems with kinematic data, constraining the mass profile shape at a population level. The framework has been previously validated using a small sample of lensing galaxies drawn from hydro-simulations. The goal of this work is to expand the validation to a more general set of lenses consistent with observed systems, as well as confirm the capacity of the method to combine two lens populations: one which has time delay information and one which lacks time delays and has systematically different image radii. For this purpose, we generated samples of analytic lens mass distributions made of baryons+dark matter and fit the subsequent mock images with standard power-law models. Corresponding kinematics data were also emulated. The hierarchical framework applied to an ensemble of time-delay lenses allowed us to correct the $H$ 0 bias associated with model choice to find $H$ 0 within 1.5σ of the fiducial value. We then combined this set with a sample of corresponding lens systems which have no time delays and have a source at lower $z$, resulting in a systematically smaller image radius relative to their effective radius. The hierarchical framework has successfully accounted for this effect, recovering a value of $H$ 0 which is both more precise (σ ~ 2%) and more accurate (0.7% median offset) than the time-delay set alone. This result confirms that non-time-delay lenses can nonetheless contribute valuable constraining power to the determination of $H$ 0 via their kinematic constraints, assuming they come from the same global population as the time-delay set.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic calculation of electric dipole strength with Skyrme-HF plus RPA

We undertake a systematic calculation on electric dipole responses of even-even nuclei for a wide mass region employing a fully self-consistent Hartree-Fock plus RPA approach. For an easy implementation of the fully self-consistent calculation, the finite amplitude method which we have proposed recently is employed. We calculate dipole responses in Cartesian mesh representation, which can deal with deformed nuclei but do not include pairing correlation. The systematic calculation has reached a mass Aapprox100 region. The calculated results show reasonable agreement for heavy nuclei while the average excitation energies are underestimated for light nuclei. We show a systematic comparison of calculated peak energies of giant dipole resonances, and the splitting of the peak energy with the ground state deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗