Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systems Engineering, Sensor Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

155 records · Page 9

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Co-Firing Switchgrass and Waste Coal in A Power Plant: A Techno-Economic and Life Cycle Evaluation for The Ohio River Valley (SWITCH) (Final Technical Report for Ohio State/FE0032204)

Abandoned coal mine lands (AMLs) represent one of the most persistent environmental challenges in the United States. Prior to the enactment of the Surface Mining Control and Reclamation Act (SMCRA) in 1977, coal mining operations were not legally required to reclaim disturbed lands, leaving behind approximately 500,000 AML sites nationwide. These sites pose severe environmental and health risks, including acid mine drainage, soil and water contamination, and spontaneous combustion of waste coal piles. Millions of Americans live within one mile of these AMLs, underscoring the urgency of remediation. Traditional reclamation practices, such as planting cool-season grasses, often fail to fully restore ecological function or leverage the economic potential of these lands. This project addressed these challenges by developing integrated strategies for resource recovery, land reclamation, and sustainable energy production. This project evaluated an integrated strategy to convert this liability into an opportunity by recovering waste coal and co-firing it with switchgrass (Panicum virgatum L.) cultivated on reclaimed or marginal AML areas in existing coal-fired power plants. Switchgrass not only provides a renewable feedstock but also aids in land reclamation and carbon sequestration. 1) Remote Sensing and Machine Learning for Waste Coal Identification Using Sentinel-2 satellite imagery and supervised classification, we applied four machine learning models to detect historical waste coal piles. Random Forest achieved the highest accuracy (precision: 86%, recall: 77%). Time-series analysis revealed gradual vegetation recovery since 1986, indicating natural reclamation processes in historical sites, while active mining areas showed ongoing disturbance. This workflow enables scalable monitoring and prioritization of reclamation efforts. 2) UAS-Based Stockpile Volume Estimation To quantify recoverable waste coal, we evaluated Unmanned Aerial Systems (UAS) equipped with Light Detection and Ranging (LiDAR) and multispectral sensors. Structure-from-Motion (SfM) photogrammetry combined with interpolated Digital Terrain Models (DTMs) achieved strong agreement with LiDAR reference volumes (Root Mean Square Error (RMSE) ≈147 m 3 , Mean Absolute Percentage Error (MAPE) ≈2%). Sensitivity analysis confirmed that spatial resolution significantly influences accuracy, emphasizing the need for high-resolution data for precise volume estimation. This approach offers a scalable, cost-effective, and accurate alternative to conventional ground-based surveys. 3) Switchgrass Cultivation for Bioenergy and Water Quality Improvement We assessed the hydrological and water quality impacts of converting AMLs to switchgrass production areas using the Soil and Water Assessment Tool (SWAT). Results showed that converting 10% of the watershed area into the switchgrass production zone reduced streamflow by 3.1%, total suspended solids by 18.1%, total nitrogen by 7.6%, and total phosphorus by 6.2%, while achieving biomass yields of 8.6–9.2 metric tons per hectare. These findings highlight switchgrass as a dual-benefit strategy for land reclamation and bioenergy feedstock production. 4) Integrated Co-Firing and CCS for Carbon-Negative Power Generation We modeled co-firing scenarios using the Power Plant Flexible Model (PPFM) to evaluate plant efficiency, greenhouse gas (GHG) emissions, and levelized cost of electricity (LCOE). Without carbon capture and storage (CCS), increasing switchgrass co-firing ratios reduced LCOE from $\$$150/MWh at 0% biomass to $\$$110/MWh at full substitution. Under CCS, costs remained higher (~$\$$250/MWh at 0% biomass) but decreased to $\$$200/MWh at 100% biomass, while enabling net-zero or carbon-negative electricity due to switchgrass sequestration benefits. Although CCS introduced efficiency penalties, pairing it with biomass co-firing offset these impacts and maximized climate benefits. Overall, optimizing co-firing ratios between 60-100%, supported by reliable logistics and storage strategies, emerged as a practical pathway to balance affordability, sustainability, and net-zero or negative GHG emissions while promoting productive reuse of AMLs.

01 COAL, LIGNITE, AND PEAT↗

Barium ion sensing with IPG K + molecular probes

Fluorophores covalently bound to azacrown ether ionophores can be assembled into sensitive turn-on chemosensors. The size specificity and electron-rich nature of the ionophore's binding domain contribute to both selectivity and strong turn-on fluorescence sensing by various mechanisms when properly constructed. Aza-18-crown-6 ethers are quite selective for binding to K + and Ba 2+ , yet the more electron-withdrawing dicationic nature of barium imposes a larger electronic effect on turn-on fluorescent sensors. Barium chemosensors can be important for measuring soluble Ba 2+ in drinking water and have gained recent attention for their potential to enhance the detection of rare events in xenon decay. Here we quantify the capability of three chemosensors, marketed for biologically useful K + sensing, as effective probes for Ba 2+ ions. Here, we present measurements from bulk spectrofluorometry to characterize the system in aqueous solutions and demonstrate the usefulness of these species for low-background single-ion fluorescence microscopy, revealing new candidates for Ba 2+ sensing.

Miller, R. L. [Department of Chemistry and Biochem↗

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

Chang, C. L. [Argonne National Laboratory 1 , 9700↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗