Search NASA⌕ Search

SEARCH · Search NASA

Results for “T cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Space Station Biological Research Project (SSBRP) Cell Culture Unit (CCU) and incubator for International Space Station (ISS) cell culture experiments

The CCU and Incubator are habitats under development by SSBRP for gravitational biology research on ISS. They will accommodate multiple specimen types and reside in either Habitat Holding Racks, or the Centrifuge Rotor, which provides selectable gravity levels of up to 2 g. The CCU can support multiple Cell Specimen Chambers, CSCs (18, 9 or 6 CSCs; 3, 10 or 30 mL in volume, respectively). CSCs are temperature controlled from 4-39 degrees C, with heat shock to 45 degrees C. CCU provides automated nutrient supply, magnetic stirring, pH/O2 monitoring, gas supply, specimen lighting, and video microscopy. Sixty sample containers holding up to 2 mL each, stored at 4-39 degrees C, are available for automated cell sampling, subculture, and injection of additives and fixatives. CSCs, sample containers, and fresh/spent media bags are crew-replaceable for long-term experiments. The Incubator provides a 4-45 degrees C controlled environment for life science experiments or storage of experimental reagents. Specimen containers and experiment unique equipment are experimenter-provided. The Specimen Chamber exchanges air with ISS cabin and has 18.8 liters of usable volume that can accommodate six trays and the following instrumentation: five relocatable thermometers, two 60 W power outlets, four analog ports, and one each relative humidity sensor, video port, ethernet port and digital input/output port.

NASA Center ARC↗

Evaluation program for secondary spacecraft cells: Evaluation of storage methods, open circuit versus continuous trickle charge, Sonotone 3.5 ampere-hour sealed nickel-cadmium secondary spacecraft cells

Twenty-five cells were used in a five-year test to compare, after each successive one-year storage period, the discharge and charge characteristics of charged cells on open circuit versus that of cells on continuous trickle charge. The test procedure, instrumentation, and results are described. Based on the test results, the following recommendations were made: (1) If the user's purpose will allow a rejuvenation cycle or two after a long storage period, the open circuit regime will likely give slightly greater capacity. (2) If the user's purpose demands immediately available power following a long storage period, the trickle charge method of storage is definitely the regime to use.

Thomas, R. E.↗

Differential electrophoretic separation of cells and its effect on cell viability

An electrophoretic separation method was applied to the separation of cells. To determine the efficiency of the separation, it was necessary to apply existing methodology and develop new methods to assess the characteristics and functions of the separated subpopulations. Through appropriate application of the widely used isoelectric focusing procedure, a reproducible separation method was developed. Cells accumulated at defined pH and 70-80% remained viable. The cells were suitable for further biologic, biochemical and immunologic studies.

Leise, E. M.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of Eagle-Picher Industries, Incorporated 6.0 ampere-hour, nickel-cadmium spacecraft cells for separator material evaluation

Several groups of nickel cadmium cells were tested for the durability of their separator materials. The cells were rated at 6.0 ampere-hours, and contained double ceramic seals. Two cells in each group were fitted with pressure gauge assemblies. Results are presented for various brands of separator materials.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of Gulton Industries, Incorporated, 9.0 ampere-hour nickel-cadmium spacecraft cells with auxiliary electrodes for the small astronomy Satellite (SAS-C)

An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Tests and results are described.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 6.0 ampere-hour nickel-cadmium spacecraft cells for the Improved Tiros Operational Satellite (ITOS)

Quality control measures for Ni-Cd spacecraft cells were analyzed. Cells were examined for electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.50 volts during the internal short test. Test results are given in tabular form.

Harkness, J. D.↗

Sensitivity of solar-cell performance to atmospheric variables. 1: Single cell

The short circuit current of a typical silicon solar cell under direct solar radiation was measured for a range of turbidity, water vapor content, and air mass to determine the relation of the solar cell calibration value (current-to-intensity ratio) to those atmospheric variables. A previously developed regression equation was modified to describe the relation between calibration value, turbidity, water vapor content, and air mass. Based on the value of the constants obtained by a least squares fit of the data to the equation, it was found that turbidity lowers the value, while increase in water vapor increases the calibration value. Cell calibration values exhibited a change of about 6% over the range of atmospheric conditions experienced.

Klucher, T. M.↗

Technology Status: Fuel Cells and Electrolysis Cells

The status of the baselined shuttle fuel cell as well as the acid membrane fuel cell and space-oriented water electrolysis technologies are presented. The more recent advances in the alkaline fuel cell technology area are the subject of a companion paper. A preliminary plan for the focusing of these technologies towards regenerative energy storage applications in the multi-hundred kilowatt range is also discussed.

Mcbryar, H.↗

Design of polymeric immunomicrospheres for cell labelling and cell separation

Synthesis of several classes of hydrophylic microspheres applied to cell labeling and cell separation is described. Five classes of cross-linked microspheres with functional groups such as carboxyl, hydroxyl, amide and/or pyridine groups were synthesized. These functional groups were used to bind covalently antibodies and other proteins to the surface of the microspheres. To optimize the derivatisation technique, polyglutaraldehyde immunomicrospheres were prepared and utilized. Specific populations of human and murine lymphocytes were labelled with microspheres synthesized by the emulsion of the ionizing radiation technique. The labelling of the cells by means of microspheres containing an iron core produced successful separation of B from T lymphocytes by means of a magnetic field.

Rembaum, A.↗

Evaluation Program for Secondary Spacecraft Cells: Initial Evaluation Tests of General Electric Company 6.0 Ampere Hour Nickel Cadmium Spacecraft Cells for the Dynamic Explorer Satellite Program

Evaluation tests of 10 nickel cadmium cells are described. Although pressures were greater than what normally was exhibited by General Electric cells in the past, it is recommended that these cells be placed on life test simulating the predicted Dynamic Explorer flight profiles.

Harkness, J. D.↗

Initial Evaluation tests of 20.0 amphere-hour sealed nickel-cadmium cells manufactured for NASA's standard cell program

Evaluation tests of 116 nickel cadmium cells provided by four manufacturers are described. Each manufacturer's group of cells, on the average, indicated an increase in plate stack thickness following the test. No limits or requirements were exceeded by any of the cells manufactured by General Electric. Limits/requirements exceeded during the charge portion of the testing are given.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

Hall, S. W.↗

Diffused junction p(+)-n solar cells in bulk GaAs. I Fabrication and cell performance

This paper describes the fabrication of solar cells made by a simple open tube p(+)-diffusion into bulk n-GaAs. In addition, cell performance is provided as an indicator of the quality of bulk GaAs for this application. Initial results using this technique (12.2 percent efficiency at AM1 for 0.5 sq cm cells) are promising, and indicate directions for materials improvement. It is shown that the introduction of the diffusant (zinc) with point defects significantly affects the material properties and results in an increase in current capability.

Bhat, I.↗

Cell and Molecular Biology of Ataxia Telangiectasia Heterozygous Human Mammary Epithelial Cells Irradiated in Culture

Autologous isolates of cell types from obligate heterozygotes with the autosomal disorder ataxia-telangiectasia (A-T)were used to begin a tissue culture model for assessing pathways of radiation-induced cancer formation in this target tissue. This was done by establishing cultures of stromal fibroblasts and long-term growth human mammary epithelial cells (HMEC) in standard 2-dimensional tissue culture in order to establish expression of markers detailing early steps of carcinogenesis. The presumptive breast cancer susceptibility of A-T heterozygotes as a sequel to damage caused by ionizing radiation provided reason to study expression of markers in irradiated HMEC. Findings from our study with HMEC have included determination of differences in specific protein expression amongst growth phase (e.g., log vs stationary) and growth progression (e.g., pass 7 vs pass 9), as well as differences in morphologic markers within populations of irradiated HMEC (e.g., development of multinucleated cells).

Richmond, Robert C.↗

Single Vector Calibration System for Multi-Axis Load Cells and Method for Calibrating a Multi-Axis Load Cell

A single vector calibration system is provided which facilitates the calibration of multi-axis load cells, including wind tunnel force balances. The single vector system provides the capability to calibrate a multi-axis load cell using a single directional load, for example loading solely in the gravitational direction. The system manipulates the load cell in three-dimensional space, while keeping the uni-directional calibration load aligned. The use of a single vector calibration load reduces the set-up time for the multi-axis load combinations needed to generate a complete calibration mathematical model. The system also reduces load application inaccuracies caused by the conventional requirement to generate multiple force vectors. The simplicity of the system reduces calibration time and cost, while simultaneously increasing calibration accuracy.

Parker, Peter A.↗

Radiation Dose-effects on Cell Cycle, Apoptosis, and Marker Expression of Ataxia Telangiectasia-Heterozygous Human Breast Epithelial Cells

Ataxia-telangiectasia (A-T) is a radiation-sensitive genetic condition. AT-heterozygous human mammary epithelial cells (HMEC) were irradiated using a Cs137 source in order to compare cell cycle, apoptosis, and marker expression responses across 3 radiation doses. No differences in cell cycle and apoptosis were found with any of the radiation doses used (30, 60, and 90 rads) compared with the unirradiated control (0 rad). At the same doses, however, differences were found in marker expression, such as keratin 18 (kl8), keratin 14 (k14), insulin-like growth factor I receptor (IGF-IR), and connexin 43 (cx43). This may indicate that radiation sensitivity in the heterozygous state may be initiated through signal transduction responses.

Cruz, A.↗