Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEM STEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Identification of interstratified mica and pyrophyllite monolayers within chlorite using advanced scanning/transmission electron microscopy

Interstratified clay minerals reflect the weathering degree and record climatic conditions and the pedogenic processes in the soil. It is hard to distinguish a few layers of interstratified clay minerals from the chlorite matrix, due to their similar two-dimensional tetrahedral-octahedral-tetrahedral (TOT) structure and electron-beam sensitive nature during transmission electron microscopy (TEM) imaging. In this study, we used multiple advanced TEM techniques including low-dose high-resolution TEM (HRTEM), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) imaging combined with energy-dispersive spectroscopic (EDS) mapping to study interstratified layers in a chlorite sample from Changping, Beijing, China. We demonstrated an interstratified mica or pyrophyllite monolayer could be well distinguished from the chlorite matrix by projected atomic structures, lattice spacings, and chemical compositions with advanced TEM techniques. Further investigation showed two different transformation mechanisms from mica or pyrophyllite to chlorite: either a 4 A increase or decrease in the lattice spacing. Lastly, this characterization approach can be extended to the studies of other electron-beam sensitive minerals.

36 MATERIALS SCIENCE↗

Microstructural Characterization of U-Nb-Zr, U-Mo-Nb, and U-Mo-Ti Alloys via Electron Microscopy

Ternary uranium molybdenum alloys are currently being investigated for use as dispersion and monolithic nuclear fuels in research reactors. In this study, two such ternary alloys, with compositions U-8Mo-3Nb and U-7Mo-3Ti in wt.%, were examined using scanning electron microscopy (SEM), X-ray diffraction (XRD), and transmission electron microscopy (TEM) with high angle annular dark field (HAADF) imaging via scanning transmission electron microscopy (STEM) to identify phase constituents. These alloys were homogenized at 950°C for 96 hours and were expected to be single-phase bcc-!-U. However, upon examination, it was determined that despite homogenization, each of the alloys contained a small volume fraction precipitate phase. Through SEM and XRD, it was confirmed that the matrix retained the bcc-!-U phase, but the precipitate phases could not be identified using these methods. TEM specimens were prepared using site-specific focused ion beam (FIB) in situ lift out (INLO) technique to include at least one precipitate from each alloy. By electron diffraction, the precipitate phases for the U- 8Mo-3Nb and U-7Mo-3Ti alloys were identified as bcc-(Mo,Nb) solid solution and bcc- (Mo,Ti) solid solution, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated Quantitative Analysis of Extended Irradiation Defects - Dislocations, Voids and Precipitates in Neutron Irradiated HT-9 Steel

Structural alloys that make up the core components of nuclear reactors are exposed to radiation that can substantially alter the microstructure and mechanical properties of the material. Irradiation can cause the formation of extended defects including dislocation line and loops, voids and various types of precipitates. To understand the irradiation effects, it is critical to characterize these defects individually and collectively to quantify how they evolve throughout irradiation stages. Transmission electron microscopy (TEM) is a standard tool for providing extensive size, number density and spatial distribution of extended irradiation defects, however, manual measurement of defect size and number density requires time-intensive effort to analyze enough defects that provide a statistically meaningful result and are prone to errors of subjectivity. In this work, we developed a set of MATLAB algorithms offering robust and automated identification and quantification of extended irradiation defects like dislocation lines, voids and precipitates commonly observed in neutron irradiated cladding alloys [1]. Using a neutron-irradiated HT-9 martensitic alloy irradiated at 412°C to 111.8 dpa, we demonstrate the capability of these algorithms for quantitative defect analysis. Figure 1 presents defect images of the HT-9 using an advanced diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) that suppresses bend contours and provides better defect contrast compared to conventional TEM [2]. The first step of defect analysis is defect identification, a process that can be digitally achieved by contrast thresholding (for simple defect contrast) and by machine learning computer vision for defect semantic segmentation [3]. Here, labeled binary defect images (Figures 2a and 2c) were used. For dislocation density quantification, we employed an optimized circular-grid intersection method first introduced by Dr. John Steeds [4]. This method is shown in Figures 2a and 2b, where the number of intersections of dislocation lines with circular traces was measured. This produces an unbiased sampling of dislocation lines, regardless of their orientation. This process was optimized with automated digital intersection number and grid length registration. Interestingly, it was found that a relatively large number of circles in a set circular gird is was needed to produce an invariant result (Figure 2b), with a low systematic measurement error. This demonstrates the main advantage of computer-based defect analysis, in performing repetitive operations quickly with a reduced systematic error. For the quantitative analysis of voids and precipitates a challenge encountered with automated defect analysis is feature overlap, particularly when the density of voids/precipitates is high. To mitigate this problem, as shown in Figure 2d, we modified the popular circular Hough transformation and treated ‘circular shape’ as the particle descriptor for voids/precipitates, efficiently resolving the overlapping particles. In summary, this automated digital quantification together with machine learning enabled defect identification [3] opens new opportunities for standardizing the characterization workflow for quantitative analysis of extended irradiation defects.

Sainju, Rajat↗

STEM Characterization of Dislocation Loops in Irradiated FCC Alloys

In this study, we demonstrate the methodology systematically developed for dislocation loop (perfect and faulted loops) imaging and analysis in irradiated face-centered-cubic (FCC) alloys using scanning transmission electron microscopy (STEM). On-zone [001] STEM imaging was identified as the preferred choice for its accuracy and effectiveness based on the comparison with other dislocation loop imaging techniques including: (i) on-zone STEM imaging using other major low-index zone axes, (ii) kinematic two-beam conditions bright field imaging near the [001] zone axis in conventional TEM (CTEM) mode, and (iii) Rel-Rod CTEM dark-field (DF) imaging near the [011] zone axis. The effect of STEM collection angle on the contrast formation of dislocation loops was also investigated. The developed method was confirmed by imaging all populations of perfect and faulted loops of types a/2$\langle$110$\rangle${110} and a/3$\langle$111$\rangle${111} found in an ion irradiated Ni40Fe40Cr20 alloy. The proposed STEM-based technique can easily identify said loops with a size greater than 10 nm without any assumptions such as those commonly made using the conventional Rel-Rod CTEM-DF technique. The recommended methodology in this study is developed as a quick and convenient tool that can be generally applied to irradiated FCC-based materials due to their common crystallography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray diffraction and in situ pressurization of dentine apatite reveals nanocrystal modulus stiffening upon carbonate removal

Bone-like materials comprise carbonated-hydroxyapatite nanocrystals (c-Ap) embedding a fibrillar collagen matrix. The mineral particles stiffen the nanocomposite by tight attachment to the protein fibrils creating a high strength and toughness material. The nanometer dimensions of c-Ap crystals make it very challenging to measure their mechanical properties. Mineral in bony tissues such as dentine contains 2~6 wt.% carbonate with possibly different elastic properties as compared with crystalline hydroxyapatite. Here we determine strain in biogenic apatite nanocrystals by directly measuring atomic deformation in pig dentine before and after removing carbonate. Transmission electron microscopy revealed the platy 3D morphology while atom probe tomography revealed carbon inside the calcium rich domains. High-energy X-ray diffraction in combination with in situ hydrostatic pressurization quantified reversible c-Ap deformations. Additionally, crystal strains differed between annealed and ashed (decarbonated) samples, following 1 or 10 h heating at 250 °C or 550 °C respectively. Measured bulk moduli (K) and a-/c-lattice deformation ratios (η) were used to generate synthetic K syn and ηsyn identifying the most likely elastic constants C 33 and C 13 for c-Ap. These were then used to calculate the nanoparticle elastic moduli. For ashed samples, we find an average E 11 =107 GPa and E 33 =128 GPa corresponding to ~5% and ~17% stiffening of the a-/c-axes of the nanocrystals as compared with the biogenic nanocrystals in annealed samples. Ashed samples exhibit ~10% lower Poisson's ratios as compared with the 0.25~0.36 range of carbonated apatite. Carbonate in c-Ap may therefore serve for tuning local deformability within bony tissues.

36 MATERIALS SCIENCE↗

A high-resolution analytical scanning transmission electron microscopy study of the early stages of spinodal decomposition in binary Fe–Cr

Spinodal decomposition (SD) is an important phenomenon in materials science and engineering. For example, it is considered to be responsible for the 475 °C embrittlement of stainless steels comprising the bcc (ferrite) or bct (martensite) phases. Structural characterization of the evolving minute nano-scale concentration fluctuations during SD in the Fe–Cr system is, however, a notable challenge, and has mainly been considered accessible via atom probe tomography (APT) and small-angle neutron scattering. The standard tool for nanostructure characterization, viz. transmission electron microscopy (TEM), has only been successfully applied to late stages of SD when embrittlement is already severe. However, we here demonstrate that the structural evolution in the early stages of SD in binary Fe–Cr, and alloys based on the binary, are accessible via analytical scanning TEM. An Fe–36 wt% Cr alloy aged at 500 °C for 1, 10 and 100 h is investigated using an aberration-corrected microscope and it is found that highly coherent and interconnected Cr-rich regions develop. The wavelength of decomposition is rather insensitive to the sample thickness and it is quantified to 2, 3 and 6 nm after ageing for 1, 10 and 100 h, which is in reasonable agreement with prior APT analysis. The concentration amplitude is more sensitive to the sample thickness and acquisition parameters but the TEM analysis is in good agreement with APT analysis for the longest ageing time. These findings open up for combinatorial TEM studies where both local crystallography and chemistry is required. - Highlights: • STEM-EELS analysis was successfully applied to resolve early stage SD in Fe–Cr. • Compositional wavelength measured with STEM-EELS compares well to previous ATP studies. • Compositional amplitude measured with STEM-EELS is a function of experimental parameters. • STEM-EELS allows for combinatorial studies of SD using complementary techniques.

36 MATERIALS SCIENCE↗

Ex Situ Investigation of Anisotropic Interconnection in Silicon-Titanium-Nickel Alloy Anode Material

Herein we investigate the nanostructural evolution of Silicon-Titanium-Nickel (Si-Ti-Ni) ternary alloy material synthesized by melt spinning process for advanced lithium-ion battery anode. The synthesized material was found to have nano-Silicon particles dispersed in the Ti 4 Ni 4 Si 7 (STN) alloy buffering matrix and was characterized by X-ray diffraction (XRD), High resolution- transmission electron microscope (HR-TEM), Scanning transmission electron microscopes - energy dispersive X-ray spectrometer (STEM-EDS), and electrochemical performance test. The role of STN matrix is to accommodate the volume expansion stresses of the dispersed Si nanoparticles. However, an interesting behavior was observed during cycling. The Si nanoparticles were observed to form interconnection channels growing through the weak STN matrix cracks and evolving to a network isolating the STN matrix into small puddles. In conclusion, this unique nanostructural evolution of Si particles and isolation of the STN matrix failing to offer significant buffering effect to the grown Si network eventually accelerates more volume expansions during cycling due to less mechanical confinement and leads to performance degradation and poor cycle stability.

36 MATERIALS SCIENCE↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Time at Temperature Abstract and Intern Poster

Current NRC regulations for BWR operations dictate that any occurrence reaching the point of Departure from Nucleate Boiling (DNB) disqualifies the use of the fuel rod for further reactor operation. That criteria does not account for duration of rate of the power increase, the corresponding effects on material properties or rewetting that may occur. Previous Anticipated Operational Occurrences (AOOs) show short durations power increase that may require limited amounts of heat removal. Industrial experience has shown evidence that fuel can reach dryout yet continue to safely operate in regular reactor conditions. The gap in research into such occurrences is the motivation for a series of experiments, including this current work. Time-at-Temperature experiments aim to identify and characterize the microstructural changes in Zircaloy-2 under oxygen-free high temperatures. This work uses the FlashDSC instrument to rapidly ramp up and down the temperature of a focus ion beam (FIB) prepared large area lift-out (LALO) of Zircaloy-2 at a rate of 10,000 K/s to desired values. The focus is to characterize the microstructure evolution, if any, of Zircaloy-2 that may impact its performance under typical BWR conditions. This characterization includes analyzing grain structure and size, secondary phase particle (SPPs) size, shape, composition, and location using Transmission Electron Microscopy (TEM). Further data collection and analysis is in progress including diffraction pattern indexing and 4D STEM processing. While current results focus on the testing and characterizing unirradiated material, future plans include expansion to irradiated material to explore the effects of rapid transition rates seen in DNB and dryout conditions on irradiationg damage and defect annealing.

36 - MATERIALS SCIENCE↗

Characterization of stress corrosion cracks in Ni-based weld alloys 52, 52M and 152 grown in high-temperature water

Ni-based weld alloys 52, 52M and 152 are extensively used in repair and mitigation of primary water stress corrosion cracking (SCC) in nuclear power plants. In the present study, a series of microstructure and microchemistry at the SCC tips of these alloys were examined with scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), scanning transmission electron microscopy (STEM) and energy filtered transmission electron microscopy (EFTEM). The specimens have similar chemical compositions and testing conditions. Intergranular (IG) and transgranular (TG) SCC was observed in all of them. The cracks were filled with nickel-oxides and partial precipitations of chrome carbides (CrCs), niobium carbides (NbCs), titanium nitrides (TiNs) and silicon carbides (SiCs), while iron (Fe) was largely dissolved into the solution. However, the crack densities, lengths and distributions were different for all three specimens. - Highlights: • Microstructure and microchemistry at the SCC tips of Ni-based weld alloys 52, 52M and 152 were examined. • The crack densities, lengths and distributions were found to be different for different alloys. • IGSCC and TGSCC were observed on alloy 52, only TGSCC was observed on alloy 52M and 152. • The cracks were filled by Ni-oxides and precipitated CrCs, NbCs, TiNs and SiCs.

36 MATERIALS SCIENCE↗

Mixed Cationic and Anionic Redox in Ni and Co Free Chalcogen-Based Cathode Chemistry for Li-Ion Batteries

Mixed cationic and anionic redox cathode chemistry is emerging as conventional cationic-redox of transition metal based layered oxides are reaching their theoretical capacity limit. However, these anionic redox in transition metal oxide-based cathodes attained by taking excess lithium has resulted in stability issues due to weak metal - oxygen ligand covalency. Here, we present an alternative approach of improving metal - ligand covalency by introducing less electronegative chalcogen ligand (sulfur) in the cathode structural framework where the metal dband penetration into ligand p-band thereby utilizing reversible mixed anionic and cationic redox chemistry. Through this design strategy, we report possibility of developing a new family of layered cathode materials when partially filled d orbital redox couples like Fe 2+/3+ are introduced in the Li-ion conducting phase (Li 2 SnS 3 ). Further, the electron energy loss spectroscopy (EELS) and X-ray absorption near-edge structure (XANES) analysis are used to qualitatively identify the charge contributors at the metal and ligand sites during Li + extraction. The detailed high-resolution transmission electron microscopy (HR-TEM) and high annular dark field-scanning transmission electron microscopy (HAADF-STEM) investigation reveal the multi redox induced structural modifications and its surface amorphization with nanopore formation during cycling. Findings from this study will shed light on designing Ni and Co free chalcogen cathodes and various functional materials in the chalcogen based dual anionic and cationic redox cathode avenue.

25 ENERGY STORAGE↗

Unveiling Structural Heterogeneity and Imbalance of Gold Decahedral Nanoparticles using Four-dimensional Scanning Transmission Electron Microscopy

Multi-twinned structures have been observed in technologically important crystal systems, for example diamond cubic and face-centered cubic (FCC) lattices, that include materials such as diamond, silicon, a wide range of noble metals, and their nanoscale counterparts. Beyond atomic building blocks, the special arrangements also occur in the self-assembly of nanoparticles (NP) and μm-sized colloidal particles and occupy parts of their phase diagrams. Spanning a wide range of length scales, the universality of the structures arises when the systems attempt to achieve multitwinned structures by overcoming geometric misfits during minimizing surface energies with entirely {111} or close-packing facets. While it is fundamental to understand how strain is sustained upon twinned structures and symmetry breaking, the knowledge will be paramount in practical aspects such as guiding and controlling the thin film growth, anisotropic NP growth, and self-assembly of NPs. Au decahedral (Dh) NP, as the most prevalent multi-twinned model system, fits five tetrahedral motifs into a circle by sharing an axis resulting in a geometric misfit angle of 7.35°, or a disclination with power of -7.35°. Postulating how Au FCC lattice adopts the misfit, theoretical models have been developed to address the underlying lattice symmetry and inhomogeneous strain distribution separately. Yet, experimental reports regarding the former have been limited due to the relatively large X-ray beam sizes that do not fit the sizes of NPs. On the other hand, though the latter has been widely adapted in the thermodynamics of small (<10 nm) multi-twinned nanoparticles, previous literature has shown that, at edge length of 17 nm, the theory’s is invalidated by shear strain that is observed in a defect-free Au Dh NP by high-resolution transmission electron microscopy (HR-TEM) imaging. Though the advancement of aberrationcorrected scanning transmission electron microscopy (AC-STEM) imaging and ab initio calculation techniques brings new opportunities, along with challenges in complicated image analysis and limitation in particle size (usually below 10 nm), the gap between nanoscale and mesoscale has never been extended to gain insight from atomic system with straightforward interaction potentials.

4D-STEM↗

Fundamental Studies of Irradiation-Induced Modifications in Microstructural Evolution and Mechanical Properties of Advanced Alloys

This final technical report summarizes the research performed during October 2014 and December 2017, with a focus on investigating the radiation-induced microstructural and mechanical property modifications in optimized advanced alloys for sodium-cooled fast reactor (SFR) structural applications. To accomplish these objectives, the radiation responses of several different advanced alloys, including austenitic steel Alloy 709 (A709) and 316H, and ferritic/ martensitic Fe–9Cr steels T91 and G92, were investigated using a combination of microstructure characterizations and nanoindentation measurements. Different types of irradiation, including ex situ bulk ion irradiation and in situ transmission electron microscopy (TEM) ion irradiation, were employed in this study. Radiation-induced dislocations, precipitates, and voids were characterized by TEM. Scanning transmission electron microscopy with energy dispersive X-ray spectroscopy (STEM-EDS) and/or atom probe tomography (APT) were used to study radiation-induced segregation and precipitation. Nanoindentation was used for hardness measurements to study irradiation hardening. Austenitic A709 and 316H was bulk-irradiated by 3.5 MeV Fe ++ ions to up to 150 peak dpa at 400, 500, and 600°. Compared to neutron-irradiated stainless steel (SS) 316, the Frank loop density of ion-irradiated A709 shows similar dose dependence at 400°, but very different temperature dependence. Due to the noticeable difference in the initial microstructure of A709 and 316H, no systematic comparison on the Frank loops in A709 vs 316H was made. It would be helpful that future ion irradiation study on 316 stainless steel could be conducted to directly compare the temperature dependence of Frank loop density in ion-irradiated 316 SS with that in neutron-irradiated 316 SS. In addition, future neutron irradiation on A709 at 400–600° at relative high dose (≥10 dpa) can be carried out to compare with ion-irradiated A709. The radiation-induced segregation (RIS) of Ni and Si was observed in both A709 and 316H in all irradiated conditions and was found at various sinks: line dislocations, dislocation loops, void surfaces, carbide-matrix interfaces, etc. Radiation also induced the formation of Ni,Si-rich precipitates. As suggested in a previous study on neutron-irradiated 316 stainless steel, one possible consequence of the significant RIS of Si is that the enrichment at defect sinks depletes the silicon in the matrix, which can lead to enhanced void nucleation rate. The enrichment of Ni and Si is accompanied by the depletion of Cr at defect sinks, which could also affect the corrosion resistance. Radiation-induced change in the orientation relationship of pre-existing MX precipitates was observed at 600°. It is believed that this change is associated with the network dislocations formed under irradiation. The underlying mechanism is still not well understood. This change could be a positive indication that the MX precipitates can survive high density network dislocations. It would be helpful if neutron irradiation at similar dose conditions could be carried out to verify that this effect is not unique for ion irradiation. Intragranular Cr-rich carbides with a core-shell structure, i.e. Cr-rich carbide core and Ni,Si-rich shell was found at 500° and 600° in the highest dose (150 peak dpa) specimens. Coarse voids (30 nm in diameter) were only commonly found at 500° in the 50 and 150 peak dpa specimens in regions less than 750 nm in depth. The highest swelling for A709 irradiated to 50 and 150 peak dpa at 500° is about 0.44% and 0.37%, respectively. Due to the choice of 100 degree temperature intervals, this study did not attempt to precisely identify peak void swelling conditions, merely the range of irradiation temperatures where this could be a concern. It is known high-dose ion irradiation can significantly suppress void nucleation. Future neutron irradiation in the 500–600° range (without considering the temperature shift) is needed to determine the onset of accelerated void swelling (possibly at lower dose).

36 MATERIALS SCIENCE↗

Electron microscopy data on irradiation effects in glassy carbon, nuclear graphite, pyrolytic carbon, and carbon fibers

Glassy carbon, a monoatomic allotrope of carbon, is a candidate material for components in fission nuclear power systems due to its radiation tolerance. This article presents comprehensive electron microscopy data revealing the effects of neutron and electron irradiation on glassy carbon. For comparison, additional data are provided for pyrolytic graphite and carbon fibers, materials that exhibit similar structural behavior under irradiation. In situ electron irradiation experiments further illustrate the real-time microstructural evolution of glassy carbon during exposure. The dataset is organized into five parts: (1) transmission electron microscopy (TEM) micrographs of as-received and neutron-irradiated glassy carbon; (2) TEM micrographs of neutron-irradiated graphite; (3) TEM micrographs of unirradiated and irradiated carbon–carbon composites; (4) TEM micrographs of pyrolytic carbon specimens in both conditions; (5) scanning transmission electron microscopy (STEM) micrographs of as-received and neutron-irradiated glassy carbon and (6) in situ electron irradiation data of a glassy carbon particle. These datasets provide valuable insights into radiation-induced structural changes in carbon-based materials relevant to nuclear applications.

36 MATERIALS SCIENCE↗