Search NASA⌕ Search

SEARCH · Search NASA

Results for “TES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Progress Towards Improved Analysis of TES X-ray Data Using Principal Component Analysis

The traditional method of applying a digital optimal filter to measure X-ray pulses from transition-edge sensor (TES) devices does not achieve the best energy resolution when the signals have a highly non-linear response to energy, or the noise is non-stationary during the pulse. We present an implementation of a method to analyze X-ray data from TESs, which is based upon principal component analysis (PCA). Our method separates the X-ray signal pulse into orthogonal components that have the largest variance. We typically recover pulse height, arrival time, differences in pulse shape, and the variation of pulse height with detector temperature. These components can then be combined to form a representation of pulse energy. An added value of this method is that by reporting information on more descriptive parameters (as opposed to a single number representing energy), we generate a much more complete picture of the pulse received. Here we report on progress in developing this technique for future implementation on X-ray telescopes. We used an 55Fe source to characterize Mo/Au TESs. On the same dataset, the PCA method recovers a spectral resolution that is better by a factor of two than achievable with digital optimal filters.

Low-temperature detectors A[center dot] Transition↗

Electron-Beam Deposition of Superconducting Molybdenum Thin Films for the Development of Mo/Au TES X-Ray Microcalorimeter

We are exploring the properties of electron-beam evaporated molybdenum thin films on silicon nitride coated silicon wafers at substrate temperatures between room temperature and 650 C. The temperature dependence of film stress, transition temperature, and electrical properties are presented. X-ray diffraction measurements are performed to gain information on molybdenum crystallite size and growth. Results show the dominant influence of the crystallite size on the intrinsic properties of our films. Wafer-scale uniformity, wafer yield, and optimal thermal bias regime for TES fabrication are discussed.

Microcalorimeter↗

Mapping TES Temperature Sensitivity and Current Sensitivity as a Function of Temperature, Current, and Magnetic Field with IV Curve and Complex Admittance Measurements

We have specialized astronomical applications for X-ray microcalorimeters with superconducting transition edge sensors (TESs) that require exceptionally good TES performance, but which operate in the small-signal regime. We have therefore begun a program to carefully characterize the entire transition surface of TESs with and without the usual zebra stripes to see if there are reproducible local “sweet spots” where the performance is much better than average. These measurements require precise knowledge of the circuit parameters. Here, we show how the Shapiro effect can be used to precisely calibrate the value of the shunt resistor. We are also investigating the effects of stress and external magnetic fields to better understand reproducibility problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced ACTPol TES Device Parameters and Noise Performance in Fielded Arrays

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the cosmic microwave background (CMB). Array testing shows highly responsive detectors with anticipated in-band noise performance under optical loading. We report on TES parameters measured with impedance data taken on a subset of TESes. We then compare modeled noise spectral densities to measurements. We find excess noise at frequencies around 100 Hz, nearly outside of the signal band of CMB measurements. In addition, we describe full-array noise measurements in the laboratory and in the field for two new AdvACT mid-frequency arrays, sensitive at bands centered on 90 and 150 GHz, and data for the high-frequency array (150/230 GHz) as deployed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array

The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the cosmic microwave background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be $r_{0.05}<0.06$ at 95% c.l., further improvements on this upper limit are hindered by polarized galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: $G, T_c, R_n, P_{sat}$, and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07×10 -17 W/$\sqrt{Hz}$, including an anticipated photon noise level 1.54×10 -17 W/$\sqrt{Hz}$.

47 OTHER INSTRUMENTATION↗

System efficiency of packed bed TES with radial flow vs. axial flow – Influence of aspect ratio

Here, this paper compares the net system efficiency, including thermal efficiency and pressure drop effects, of radial versus axial flow packed beds for thermal energy storage. The traditional packed bed system is a cylindrical geometry where fluid flows axially from one end to another. However, issues of thermal stratification and high-pressure drop have led to recent studies on radial flow systems. One potential benefit is the reduced pressure drop in a radial flow system. This paper compares the performance of radial flow and axial flow systems at a range of aspect ratios (AR = H/D bed ) from 0.21 to 1.92 using a numerical model where the storage volume is held constant in all cases. When the radial flow bed is at a low aspect ratio (short/wide), the thermal front is improved but the pressure drop is high. At a high aspect ratio, the velocity is reduced in radial flow, leading to decreased pressure drop but an increased spreads in the thermal front that lowers thermal efficiency. The opposite trends are noted in axial flow. Thermal efficiencies of 83–91 % were noted for radial flow, while they ranged from 85 to 94 % in axial flow. Net efficiencies including pressure drop ranged from 74 to 82 % for radial flow and 80–87 % for axial flow. In both systems, a peak net efficiency was noted between the highest and lowest aspect ratio. While some aspect ratios with radial flow outperform axial flow from a net efficiency perspective, the results show that the highest net efficiency from axial flow is higher than that from radial flow. Overall, this paper highlights the importance of innovative TES designs and their potential to improve energy efficiency.

25 ENERGY STORAGE↗

Thermal modeling of absorber-coupled TES polarimeter.

Using experimental thermal conductivity and volume heat capacity of narrow silicon nitride beams obtained from thermal test structures and a boundary limited phonon scattering model, as well as the heat conduction equation, we analyze the thermal performance of an absorber-coupled TES polarimeter with finite element method. The polarimeter's temperature distribution, thermal power readout efficiency, and time constant are calculated. The thermal power readout efficiency of the polarimeter is up to 87% at a low signal modulation frequency, and has a 0.5 dB attenuation at 120 Hz. We also compare a preliminary optical testing result with theoretical expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion Beam Analysis of Iridium-Based TES for Microcalorimeter Detectors

The physical properties of thin multilayer structures are deeply related to the crystalline quality and stoichiometry of the films. The interface roughness/mixing require a detailed study to determine its influence on the growth processes and surface topography. This is an important aspect when we have lattice mismatch between the superconducting thin-films and the substrates, and a high reliability/reproducibility is required as for large array microcalorimeter applications, as in the case of the MARE experiment, designed to measure the mass of the neutrino with sub-eV sensitivity by measuring the beta decay of {sup 187}Re with cryogenic microcalorimeters. Ion beam analysis techniques are ideal to determine the thickness and concentration profiles of the chemical species in ultra-thin films. Here we present the results on the Ir-based superconducting films deposited on Si-substrates based on systematic investigations of the concentration depth profiles of the multilayer structure using 2.0 MeV {sup 4}He{sup +} ions for high resolution Rutherford Backscattering Spectrometry combined with X-Ray Reflectrometry to evaluate the interface/roughness mixing and the crystalline quality in the TES prototypes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Thermal Conductance Transition Edge Sensor (TES) for SPICA

We fabricated and characterized low thermal conductance transition edge sensors (TES) for SAFARI instrument on SPICA. The device is based on a superconducting Ti/Au bilayer deposited on suspended SiN membrane. The critical temperature of the device is 113 mK. The low thermal conductance is realized by using long and narrow SiN supporting legs. All measurements were performed having the device in a light-tight box, which to a great extent eliminates the loading of the background radiation. We measured the current-voltage (IV) characteristics of the device in different bath temperatures and determine the thermal conductance (G) to be equal to 320 fW/K. This value corresponds to a noise equivalent power (NEP) of 3x10{sup -19} W/{radical}(Hz). The current noise and complex impedance is also measured at different bias points at 55 mK bath temperature. The measured electrical (dark) NEP is 1x10{sup -18} W/{radical}(Hz), which is about a factor of 3 higher than what we expect from the thermal conductance that comes out of the IV curves. Despite using a light-tight box, the photon noise might still be the source of this excess noise. We also measured the complex impedance of the same device at several bias points. Fitting a simple first order thermal-electrical model to the measured data, we find an effective time constant of about 2.7 ms and a thermal capacity of 13 fJ/K in the middle of the transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA), requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%). A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations, simulations and preliminary measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AmeriFlux MX-Tes Tesopaco, secondary tropical dry forest

This is the AmeriFlux version of the carbon flux data for the site MX-Tes Tesopaco, secondary tropical dry forest. Site Description - This tower was located in the "Ejido la Estrella" where the eddy covariance tower is located 7.5 km east of the town Rosario de Tesopaco, in southeastern Sonora, Mexico. The tower was positioned in the center of a homogeneous flat terrain at the foothills of the Madre Occidental. This ecosystem lies in a highly seasonal region under the influence of the North American Monsoon that brings about 70% of the rains from July to September. The site is dominated by leguminous trees. Some of the dominant species are Lysiloma divaricatum, Ipomoea arborescens, Acacia cochliacantha, Haematoxylum brasiletto, and Celtis reticulata. The mean basal area at the study site is 14.83 ± 3.3m2 ha-1, and the aboveground biomass is estimated to be 43.20±9.5Mgha-1. These values and the high counts of Acacia cochliacantha indicate that the area is a secondary forest with significant management activities in the past.

Yepez, Enrico A.↗

Data-Model Needs for Belowground Ecology. A Summary Report from the Terrestrial Ecosystem Science (TES) Mini-Workshop, May 8, 2014

Terrestrial life on Earth depends on belowground cycling and storage of a significant portion of the planet’s biologically-active carbon. The interplay among organic inputs by primary producers, soil organic matter stabilization, and assimilation and mineralization by soil organisms drives belowground ecology. Understanding belowground carbon dynamics, including the stability and vulnerability of soil organic carbon stocks, is necessary to project the responses and feedbacks of terrestrial ecosystems to a changing climate. Although conceptually understood, belowground hydrobiogeochemical systems are not well characterized with quantitative and mechanistic representations of critical functions. As a result, these systems are inadequately represented in modeling efforts, limiting our ability to understand and project terrestrial carbon source/sink relationships at various temporal and spatial scales. The belowground science community lacks robust databases and data libraries against which model sensitivities and performance can be tested and enhanced. Improved understanding of belowground ecosystems, including biotic and abiotic interactions, is needed to ensure that model structures include and provide adequate representations of critical belowground processes, functions, and dynamics. A one-day workshop brought together experimental and modeling representatives from the four Department of Energy (DOE) National Laboratories where the Office of Biological and Environmental Research (BER) Terrestrial Ecosystem Science (TES) program has investments in belowground ecology. The group focused on identifying and characterizing (1) critical experimental and observational datasets for testing and developing existing and future belowground-process models and land models; (2) the limitations and needs for modeling belowground processes within ecosystem models; and (3) key areas for leveraging current research activities across the National Laboratories and BER-funded projects. Discussion results are organized in this report as: (I) over-arching data requirements for advancing understanding of belowground ecosystems; (II) efforts that could rapidly improve understanding and model representations of belowground components of terrestrial ecosystems; and (III) longer-term research needs that would benefit from greater and more sustained support.

54 ENVIRONMENTAL SCIENCES↗

TES (Thermal Energy Storage) Video News Release

TES is an in-space technology experiment that flew on STS-62. Its intent is to investigate the behavior of two different thermal energy storage materials as they undergo repeated melting and freezing in the microgravity environment.

Source record↗

Properties of Suspended Martian Dust Using MGS-TES Data

This analysis of MGS-TES data from the recent global dust storm allows dust optical properties, optical depth, particle size distribution, and surface temperatures to be derived for multiple-scattering atmospheres using radiative transfer methods. Additional information is contained in the original extended abstract.

Snook, K. J.↗