Search NASA⌕ Search

SEARCH · Search NASA

Results for “THM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A coupled THMC model of a heating and hydration laboratory experiment in unsaturated compacted FEBEX bentonite

Unsaturated compacted bentonite is foreseen by several countries as a backfill and sealing material in high-level radioactive waste repositories. The strong interplays between thermal (T), hydrodynamic (H), mechanical (M) and chemical (C) processes during the hydration stage of a repository call for fully coupled THMC models. Validation of such THMC models is prevented by the lack of comprehensive THMC experiments and the difficulties of experimental methods to measure accurately the chemical composition of bentonite porewater. We present here a non-isothermal multiphase flow and multicomponent reactive solute transport model for a deformable medium of a heating and hydration experiment performed on a sample of compacted FEBEX bentonite. Besides standard solute transport and geochemical processes, the model accounts for solute cross diffusion and thermal and chemical osmosis. Bentonite swelling is solved with a state-surface approach. The THM model is calibrated with transient temperature, water content and porosity data measured at the end of the experiment. The reactive transport model is calibrated with porewater chemical data derived from aqueous extract data. Model results confirm that thermal osmosis is relevant for the hydration of FEBEX bentonite while chemical osmosis can be safely neglected. Dilution and evaporation are the main processes controlling the concentration of conservative species. Dissolved cations are mostly affected by calcite dissolution-precipitation and cation exchange reactions. Dissolved sulphate is controlled by gypsum/anhydrite dissolution-precipitation. pH is mostly buffered by protonation/deprotonation via surface complexation. Computed concentrations agree well with inferred aqueous extract data at all sections except near the hydration boundary where cation data are affected by a sampling artifact. The fit of Cl{sup -} data is excellent except for the data near the heater. The largest deviations of the model from inferred aqueous extract data occur for dissolved SO{sub 4}{sup 2-} which is underpredicted by the model. There are uncertainties on the amount of gypsum available for dissolution and its dissolution mechanism (kinetics or local equilibrium).

54 ENVIRONMENTAL SCIENCES↗

Effects of anisotropic shale creep on the stress and permeability evolution of a geological nuclear waste repository

To ensure long-term safety and performance, geological nuclear waste repositories require low-permeability barriers such as bentonite buffers and/or shale host rock. Shale is not only known for its low permeability but also for its trend to undergo time-dependent deformation (i.e., creep), which could heal damage, but the effects of shale creep on the long-term performance of nuclear waste repositories have not been clearly understood. In particular, the anisotropic nature of shale (i.e., bedding) could have a significant effect on its creep behavior, and consequently, on the long-term performance of nuclear waste repositories. In this research, numerical simulations were carried out with the objective of showing the effects of anisotropic shale creep on the stress and permeability evolution of a generic geological nuclear waste repository in shale. The TOUGH-FLAC simulator, a thermo-hydromechanically (THM) coupled numerical code, was used for the simulations. To achieve the objective, comparisons were performed between the results of anisotropic shale creep simulations and those of different simulation cases, namely, no creep (i.e., elastic), isotropic creep, and long-term creep shale cases. Results of the comparisons show that the elastic and isotropic creep shale cases respectively led to the overestimation and underestimation of stress and permeability in the repository, whereas the long-term creep shale case, which accumulated greater creep in later periods than in earlier periods, helped to keep large shear and tensile stresses from developing while maintaining compressive spherical stress, resulting in consistently low permeability levels. These results indicate that performance assessments with elastic and isotropic creep formation models will provide the upper and lower bound estimates of stress and permeability, while more reasonable estimates will be given by an anisotropic creep formation model, and that shale with long-term creep characteristics will be beneficial in many aspects of the safety and performance of nuclear waste repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancement of disposal efficiency for deep geological repositories based on three design factors - Decay heat optimization, increased thermal limit of the buffer and double-layer concept

This study investigates the enhancement of disposal efficiency for deep geological repositories (DGRs) based on three design factors: decay heat optimization, increased thermal limit of the buffer, and double-layer concept using coupled thermo-hydro-mechanical (THM) numerical simulations. Decay heat optimization is achieved by iteratively emplacing spent nuclear fuels having the maximum and minimum decay heat in a canister. Disposal areas can be reduced by 20 % to 40 % compared to the current reference disposal system in Korea (KRS+) in accordance with the combinations of the three design factors, alleviating challenges in site selection for the DGR. This study additionally identifies an optimal layer spacing of 500 m for the double-layer concept in the viewpoint of the buffer temperature, where thermal interaction between the upper and lower layers nearly disappears. However, determining the ultimate disposal and layer spacing requires engineering judgement, considering not only the thermal performance of the DGR but also various factors such as cost and difficulties of the construction and rock mass stability. DGRs designed with an increased thermal limit of the buffer poses a greater probability of rock mass failure around disposal tunnels and deposition holes due to elevated thermal stresses. Densely arranged heat sources for the DGRs with enhanced disposal efficiency lead to larger temperature increase even at the far-field scale, raising a possibility of thermally driven fracture shear activation with associated hydraulic, mechanical, and seismic changes.

58 GEOSCIENCES↗

Role of Selenium Addition to CdZnTe Matrix for Room-Temperature Radiation Detector Applications

Because of its ideal band gap, high density and high electron mobility-lifetime product, cadmium zinc telluride (CdZnTe or CZT) is currently the best room-temperature compound-semiconductor X- and gamma-ray detector material. However, because of its innate poor thermo-physical properties and above unity segregation coefficient for Zn, the wide spread deployment of this material in large-volume CZT detectors is still limited by the high production cost. The underlying reason for the low yield of high-quality material is that CZT suffers from three major detrimental defects: compositional inhomogeneity, high concentrations of dislocation walls/sub-grain boundary networks and high concentrations of Te inclusions/precipitates. To mitigate all these disadvantages, we report for the first time the effects of the addition of selenium to the CZT matrix. The addition of Se was found to be very effective in arresting the formation of sub-grain boundaries and its networks, significantly reducing Zn segregation, improving compositional homogeneity and resulting in much lower concentrations of Te inclusions/precipitates. Growth of the new quaternary crystal Cd 1-x Zn x Te 1-y Se y (CZTS) by the Traveling Heater Method (THM) is reported in this paper. We have demonstrated the production of much higher yield according to its compositional homogeneity, with substantially lower sub-grain boundaries and their network, and a lower concentration of Te inclusions/precipitates.

36 MATERIALS SCIENCE↗

Evaluation of CdZnTeSe as a high-quality gamma-ray spectroscopic material with better compositional homogeneity and reduced defects

X- and gamma-ray detectors have broad applications ranging from medical imaging to security, non-proliferation, high-energy physics and astrophysics. Detectors with high energy resolution, e.g. less than 1.5% resolution at 662 keV at room temperature, are critically important in most uses. The efficacy of adding selenium to the cadmium zinc telluride (CdZnTe) matrix for radiation detector applications has been studied. In this paper, the growth of a new quaternary compound Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 by the Traveling Heater Method (THM) is reported. The crystals possess a very high compositional homogeneity with less extended defects, such as secondary phases and sub-grain boundary networks. Virtual Frisch-grid detectors fabricated from as-grown ingots revealed ~0.87-1.5% energy resolution for 662-keV gamma rays. The superior material quality with a very low density of defects and very high compositional homogeneity heightens the likelihood that Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 will be the next generation room-temperature detector material.

36 MATERIALS SCIENCE↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Indirect Measurements for (p,{alpha}) Reactions Involving Boron Isotopes

Light elements lithium, beryllium and boron (LiBeB) were used in the last years as 'possible probe' for a deeper understanding of some extra-mixing phenomena occurring in young Main-Sequence stars. They are mainly destroyed by (p,{alpha}) reactions and cross section measurements for such channels are then needed. The Trojan Horse Method (THM) allows one to extract the astrophysical S(E)-factor without the experience of tunneling through the Coulomb barrier. In this work a resume of the recent results about the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be and {sup 10}B(p,{alpha}){sup 7}Be reactions is shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent astrophysical applications of the Trojan Horse Method to nuclear astrophysics

The Trojan Horse Method (THM) is an unique indirect technique allowing to measure astrophysical rearrangement reactions down to astrophysical relevant energies. The basic principle and a review of the recent applications of the Trojan Horse Method are presented. The applications aiming to the extraction of the bare astrophysical S{sub b}(E) for some two-body processes are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of {sup 17}O(p,{alpha}){sup 14}N reaction via the Trojan Horse Method for application to {sup 17}O nucleosynthesis

Because of the still present uncertainties on its rate, the {sup 17}O(p,{alpha}){sup 14}N is one of the most important reaction to be studied in order to get more information about the fate of {sup 17}O in different astrophysical scenarios. The preliminary study of the three-body reaction {sup 2}H({sup 17}O,{alpha}{sup 14}N)n is presented here as a first stage of the indirect study of this important {sup 17}O(p,{alpha}){sup 14}N reaction through the Trojan Horse Method (THM)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Distortion on the Intercluster Motion in Light Nuclei

Deuteron induced quasi-free scattering and reactions have been extensively investigated in the past few decades as well as {sup 6}Li, {sup 3}He and {sup 9}Be induced ones. This was done not only for nuclear structure and processes study but also for the important astrophysical implication (Trojan Horse Method, THM). In particular the width of the spectator momentum distribution in {sup 6}Li and deuterium, which have widely been used as a Trojan Horse nuclei, will be studied as a function of the transferred momentum. Trojan horse method applications will also be discussed in these cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The {sup 2}H(d,p){sup 3}H Reaction At Astrophysical Energies Studied Via The Trojan Horse Method And Pole Approximation Validity Test

In order to understand primordial and stellar nucleosynthesis, we have studied {sup 2}H(d,p){sup 3}H reaction at 0, 4 MeV down to astrophysical energies. Knowledge of this S-factor is interesting also to plan reactions for fusion reactors to produce energy. {sup 2}H(d,p){sup 3}H has been studied through the Trojan Horse Method applied to the three-body reaction {sup 2}H({sup 3}He,pt)H, at a beam energy of 17 MeV. Once protons and tritons are detected in coincidence and the quasi-free events are selected, the obtained S-factor has been compared with direct reactions results. Such data are in agreement with the direct ones, and a pole invariance test has been obtained comparing the present result with another {sup 2}H(d,p){sup 3}H THM one, performed with a different spectator particle (see fig. 1).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Indirect Approach To The {sup 2}H(d,p){sup 3}H Reaction Study

In order to understand primordial and stellar nucleosynthesis, we have studied {sup 2}H(d,p){sup 3}H reaction at 0.4 MeV down to astrophysical energies. Knowledge of its S-factor is interesting also to plan reactions for fusion reactors to produce energy. The {sup 2}H(d,p)H reaction has been studied through the Trojan Horse Method applied to the three-body reaction {sup 2}H(He,pt)H, at beam energy of 17 MeV. Once selection of protons and tritons detected in coincidence and the selection of quasi-free events, the obtained S-factor is compared with direct measurements. Such data are in agreement with the direct ones and a pole invariance test has been obtained comparing the present results with another {sup 2}H(d,p){sup 3}H THM measurements, where a different spectator particle was employed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent applications of the the Trojan Horse method to nuclear astrophysics

Light elements lithium, beryllium and boron (LiBeB) have been used in the last years as possible probes for stellar structure. They are mainly destroyed by (p,a) reactions and cross section measurements for such channels are then needed. The Trojan Horse Method (THM) allows one to extract the astrophysical S(E)-factor without the experience of tunneling through the Coulomb barrier. In this work a resume of the recent new results about the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be and {sup 7}Li(p,{alpha}){sup 4}He reactions are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distortion effects in Trojan Horse applications

Deuteron induced quasi-free scattering and reactions have been extensively investigated in the past few decades. This was done not only for nuclear structure and processes study but also for the important astrophysical implication (Trojan Horse Method, THM). In particular the width of the neutron momentum distribution in deuteron will be studied as a function of the transferred momentum. The same will be done for other nuclides of possible use as Trojan Horse particles. Trojan horse method applications will also be discussed because the momentum distribution of the spectator particle inside the Trojan horse nucleus is a necessary input for this method. The impact of the width (FWHM) variation on the extraction of the astrophysical S(E)-factor is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light elements burning reaction rates at stellar temperatures as deduced by the Trojan Horse measurements

Experimental nuclear astrophysics aims at determining the reaction rates for astrophysically relevant reactions at their Gamow energies. For charged-particle induced reactions, the access to these energies is usually hindered, in direct measurements, by the presence of the Coulomb barrier between the interacting particles or by electron screening effects, which make hard the determination of the bare-nucleus S(E)-factor of interest for astrophysical codes. The use of the Trojan Horse Method (THM) appears as one of the most suitable tools for investigating nuclear processes of interest for astrophysics. Here, in view of the recent TH measurements, the main destruction channels for deuterium ({sup 2}H), for the two lithium {sup 6,7}Li isotopes, for the {sup 9}Be and the one for the two boron {sup 10,11}B isotopes will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge-Transport Properties of As-Grown Cd 1-x Zn x Te 1-y Se y by the Traveling Heater Method

In this article, we report on the charge-transport characteristics of a new quaternary material Cd 1-x Zn x Te 1-y Se y (CZTS) grown by the Traveling Heater Method (THM). The as-grown CZTS material was found to possess fewer Te inclusions than CZT. Moreover, high resistivity of ~1-2x10 10 ohm-cm was achieved, meeting the requirements of most gamma-ray detector applications. The mobility-lifetime product for electrons [(µτ) e ] was measured to be ~4x10 -3 cm 2 /V. The energy resolution for the quasi-hemispherical detector fabricated from the as-grown CZTS ingot obtained was ~2.8% (FWHM) at 662 keV.

36 MATERIALS SCIENCE↗

Characterization of large-volume Frisch grid detector fabricated from as-grown CdZnTeSe

CdZnTe (CZT) has been under continuous development as a room-temperature radiation detector for the past 2-3 decades. Due to its intrinsic defects, such as a high concentration sub-grain boundary network, it has been very challenging to consistently produce high-quality CZT detectors with high yield, particularly for detector volumes exceeding a few cm 3 . In this paper, we report characterization of a relatively large-volume Frisch-grid detector (dimensions: 11x10.8x19.4 mm 3 ) fabricated from a new material Cd 0.9 Zn 0.1 Te 0.985 Se 0.015 . Furthermore, the detector was fabricated from an as-grown ingot with a two-inch diameter grown by the Traveling Heater Method (THM). The detector sample was evaluated by infrared (IR) transmission microscopy to study the presence of Te inclusions. X-ray topography using a synchrotron light source was deployed to measure the presence of sub-grain boundaries and their networks. Finally, the detector performance was measured for an optimized Frisch-grid length to extract the best energy resolution at room temperature.

36 MATERIALS SCIENCE↗

Assessment of deep levels with selenium concentration in Cd 1–x Zn x Te 1–y Se y room temperature detector materials

Incorporation of Se into Cd 1–x Zn x Te (CZT) to form the quaternary compound semiconductor Cd 1–x Zn x Te 1–y Se y (CZTS) has proven to be an effective solution for compensating the major flaws associated with CZT, including poor homogeneity and high concentrations of electronically active deep levels that limit the performance of CZT detectors. In order to investigate how deep levels are affected by the Se concentration in CZTS, we performed photoinduced current transient spectroscopy (PICTS) measurements on CZTS crystals grown by the traveling heater method (THM) with 10% atomic Zn and varying atomic percentage of Se from 1.5% to 7.0%. The PICTS scans for up to 4% Se showed an exponential reduction in the capture cross section of deep levels associated with Te secondary phases in conjunction with an increase in a deep level positioned near the mid-gap, which initially increases the electron trapping time before degrading again at higher Se concentrations. The PICTS peaks present in 7% Se were anomalous relative to the other crystals and are expected to originate from transition metal impurities found in the lower-purity CdSe precursor material.

36 MATERIALS SCIENCE↗