Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Transfer commercialization of technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Catalytic Bio-crude Production in a Novel, Short-Contact Time Reactor

RTI has developed a catalytic fast pyrolysis (CFP) process to produce biomass-based hydrocarbon replacement fuels. From a technology perspective, this advanced biofuels process produces liquid transportation fuels that can leverage capital expenditures in the existing petroleum distribution infrastructure. From a business perspective, this technology does not face potential market limitations caused by oxygenate blend limitations for light duty vehicle applications. A promising catalyst has been developed with excellent potential for deoxygenation to produce a hydrocarbon-rich biocrude that is more suitable for upgrading with traditional hydroprocessing technology. The role of the catalyst is to control the chemistry during biomass pyrolysis to produce a biocrude in a single step that has lower oxygen content and is more thermally stable than conventional biomass fast pyrolysis oil. Catalyst properties are optimized to minimize gas and coke production and improve catalytic deoxygenation and biocrude yields. Results from this project have demonstrated that biocrudes from catalytic fast pyrolysis contain <20 wt% oxygen, with the organic fraction as low as 12% oxygen. These oxygen numbers are > 50% lower compared to traditional fast pyrolysis oils. The biocrude produced from our CFP process can be upgraded to gasoline range hydrocarbons. A very conservative approach for upgrading included a preliminary stabilization step followed by a hydroprocessing step. The oxygen content in the upgraded product was decreased by 97% (to less than 3wt %) from the oxygen content of the biocrude sample. Additionally, the acid content was reduced by 99% from the acid content of the biocrude sample. In an optimized integrated process, the CFP step and the hydroprocessing (upgrading) step need to be carefully balanced to maximize the input biomass energy that is recovered in the finished biofuels. Hydrogen utilization and carbon recovery during both catalytic biomass pyrolysis and biocrude upgrading need to be optimized to maximize energy recovery in the finished biofuel. A nominal 1 ton per day (TPD) catalytic biomass pyrolysis system was designed based on the laboratory experimental data. The system was designed to achieve the short residence times (0.5–2 sec) and high heat transfer rates required for maximum liquid biocrude yields while optimizing process integration to maintain catalyst activity by continuous regeneration. The catalytic biomass pyrolysis reactor is a continuously circulating single-loop transport reactor design that is flexible enough to allow sensitivity studies around temperature, residence time, biomass feed rate, and catalyst-to-biomass ratio (i.e., catalyst circulation rate) for process optimization. For a nominal 100 lb/hr feed rate of dry biomass, the products include ~25 lb/hr char and coke, ~20 lb/hr permanent gases, and ~55 lb/hr condensable vapors. Pyrolysis temperatures are 350–600°C, and the system is operated close to ambient pressure. Production of the catalyst developed within the project was scaled up to provide enough material (200kg) for bench-scale testing. The 1TPD bench-scale unit was fabricated, installed and commissioned with this project. Biocrude samples from wood were produced in this unit with the CFP catalyst with material balance > 90%. The intermediate biocrude yields and chemical composition compare well with previous laboratory results and a hydroprocessing strategy for upgrading the resulting biocrude was developed. The experimental results obtained within this project were used to develop a process model for a 2000 TPD commercial facility. Detailed flow sheets were developed for all major unit operations in the process and provided a basis for an economic analysis to develop capital and operating costs. Estimates of the biofuel production costs were used to develop internal rates of return for the yields and compositions measured for the current state of technology at the end of this project and for the yields anticipated for an optimized (nth plant) scenario as additional process improvements are made.

09 BIOMASS FUELS↗

Microreactor Agile Nonnuclear Experimental Testbed Test Plan

Microreactors are an attractive technology option for kick-starting nuclear innovation if they can be operated at high temperature, yielding high power conversion thermal efficiencies comparable or better than in commercial light water reactors. Microreactors are currently the smallest variation of Small Modular Reactors (SMRs). SMRs are “newer generation reactors designed to generate electric power up to 300 MWe and whose components and systems can be shop-fabricated and then transported as modules to the sites for installation as demand arises.” (IAEA, 2016). Vendors are developing microreactor designs to provide an affordable, potentially mobile source of electricity - see Fig. 1 for an example of a microreactor on a semi-truck. Various microreactor designs are possible including heat pipe- and gascooled options, which are the focus of the nonnuclear testing described in this document. In heat pipe microreactors, high-temperature heat pipes using liquid sodium or potassium working fluid transport fission heat from the core to a heat removal section which in turn transfers heat to the power conversion system working fluid. In a gas-cooled design, He or other gas will flow through a solid monolith of material and transfer heat as the temperature of the gas increases through a heat exchanger to a power conversion unit. The logistics of all these processes will be examined and tested through a series of articles at the nonnuclear test bed at Idaho National Laboratory (INL), the Microreactor Agile Nonnuclear Experiment Testbed (MAGNET) facility. Microreactors designed to produce power of 0.1-20 MWt offer the potential for more affordable nuclear energy for a range of applications. In a heat pipe microreactor, heat pipes, fuel rods, and/or moderator are intermixed in the reactor core assembly. Heat pipes extend from the core region into the heat removal section where the power conversion unit working fluid flows through holes or channels, transferring heat from the heat pipes to the working fluid. In a gas-cooled microreactor, gas flows through the solid monolith region and up into the heat exchanger region, transferring heat to the working fluid. For initial testing, the heat removal working fluid can be a low pressure gas for testing that addresses thermal stresses. In the final application, heat addition to the power conversion working fluid typically occurs at high pressure, supporting operation of an air-Brayton, supercritical CO 2 (SCO2), or He-recuperated Brayton cycle. Various stages of the steps above will be demonstrated through the tests described in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

Capacitive deionization using carbon derived from an array of zeolitic-imidazolate frameworks

Capacitive deionization (CDI) represents one of the most thermodynamically efficient technologies for brackish water desalination. Its performance is highly reliant on the surface properties of carbon-based electrodes. Zeolitic-imidazolate framework (ZIF)-derived carbon materials have emerged among the most promising candidates owing to their high structural and compositional tuneability. However, the impacts of the precursory ZIF structure on the properties of the final carbon, and therefore, CDI capacity and efficiency remain to be further explored. In this work, four Zn-based ZIFs with different side-chain substitutions on the imidazolates were synthesized on a gram scale with high yields to produce N-doped carbons by pyrolysis. Next, the resulting carbons along with four commercial carbon blacks were characterized physically and electrochemically to explore the structure-performance relationship. We demonstrated that the imidazole side-chain substitution alters the ZIF's decomposition during pyrolysis, influencing the elemental compositions, surface properties, wettability and graphitization levels. The diverse carbon properties result in variable double layer capacitance and charge-transfer resistance, ultimately impacting the CDI performance. Among these carbons, Zn (4abIm)2-C afforded the greatest salt adsorption capacity of 14.19 mg NaCl $·g_C^{–1}$, while Zn (mIm) 2 -C showed the highest overall salt adsorption capacity and rate; both exceeded the performance of the commercial carbon blacks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Active and Resilient Bilayer Oxygen Electrode for Intermediate Temperature Reversible Solid Oxide Cells

High temperature solid oxide cells (SOCs) have intrinsic advantage in efficiency over conventional internal combustion engines for power generation and low-temperature electrolysis cells for H2 production. This efficiency advantage could potentially lead to cost saving and emission reduction. However, commercialization of the current SOCs technology is hindered by its poor durability. One major component with the durability issue is oxygen electrode (OE). For example, the durability of OEs can be negatively affected by the gaseous Cr-species originated from the air oxidation of high-temperature alloy interconnect. For electrolysis operation, on the other hand, delamination of OE from electrolyte, particularly at high current densities, has been identified as a major cause for the performance degradation. Therefore, developing robust and active OEs is of critical importance to SOC technology. WE have previously demonstrated a new bilayer OE with strong activity and stability. Here in this presentation, we present recent results of electrochemical characterization on bilayer OE operating under both fuel cell and electrolysis modes. We will first show the optimization of bilayer OE in terms of thickness, morphology, and calcination temperature and their impacts on cell area specific resistance (ASR). With three-electrode symmetric cell configuration, we also show the results of charge transfer ASR of bilayer OE as a function of current density, temperature, and time in different atmospheres. The results are further compared with the baseline OE (LSCF+GDC) to demonstrate the advantage of bilayer OE.

Huang, Kevin↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TCO Analysis Approach and Regional Analysis of dWPT for Class 8 Tractors

Dynamic Wireless Power Transfer (dWPT) is a method by which battery electric vehicles (BEVs) can charge their battery while traveling on the road without the need for a physical conductive connection to the power source. dWPT has been proposed as a strategy to enable a reduction in vehicle battery capacity and associated mass and cost. In this slide deck presented at the EVs@Scale Consortium - Wireless Power Transfer Pillar Deep-Dive Meeting on November 11th, 2023, NREL provides results from an evaluation of dWPT using data from Class 8 tractors driving in the Atlanta Metro Area. NREL selected data for archetypal days representing local, regional, and long-haul trips, defined according to trip length, that included travel on primary roadways. EVI-InMotion (Electric Vehicle Infrastructure - InMotion), a systems planning and optimization tool developed at NREL, was used to evaluate dWPT performance assuming dWPT charging on 120 road segments for a total roadway lane distance of 2,365 miles. The EVI-InMotion results and representative day drive cycles were analyzed with NREL's T3CO (Transportation Technology Total Cost of Ownership) tool to estimate the total cost of ownership (TCO) for scenarios comprising two model years - 2030 and 2040 - and two technology progress cases. TCO was calculated for diesel, fuel cell electric, BEVs with batteries sized assuming no dWPT capabilities, and 200kWh BEVs with dWPT installed. This analysis finds that en-route stationary charging frequency and downtime when not on electrified roadways are the main contributors to TCO for the dWPT vehicles and that these vehicles can achieve cost parity with FCEVs at low electricity costs. Based on the scenario assumptions used here, low electricity costs would further help the cost parity with diesel vehicles in regional and long-haul cases due to stationary fueling downtime. This presentation also concludes that key factors affecting the parity potential of dWPT-capable vehicles include more extensive dWPT road coverage, higher en-route charging power, less expensive power batteries, and higher hydrogen or diesel fuel costs.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of design and operating parameters for additively manufactured intensified packing devices on CO 2 -Absorption column cooling and capture efficiency

Solvent-based CO 2 absorption is technologically a matured CO 2 capture pathway but suffers from: high regeneration energy demand, and solvent temperature rise and decreased capture efficiency caused by the heat of reaction. While research has focused on developing non-aqueous and low-aqueous solvents for decreasing the regeneration energy, the temperature bulge due to exothermic absorption is typically dealt with by cooling the solvent with an external inter-stage heat-exchanger. This approach may increase the overall process footprint, as well as capital and operating costs. Here, the current study explores a process intensification approach by incorporating inside the column an additively manufactured intensified packing device that consists of corrugated plates and internal coolant channels. The corrugated plates provide surface area for mass transfer between gas and liquid, while cooling fluid inside the internal channels removes heat from the exothermic reactive system. Two different intensified devices with specific surface areas of 266 m 2 /m 3 and 359 m 2 /m 3 were designed, manufactured, and tested inside a 2.06-m long and 0.203-m diameter column packed with commercial Mellapak 250Y packing. The device with a lower surface area showed up to 27 % reduction in cooling performance. A steady-state heat transfer model provides good agreement with the experimental column temperature and intra-stage heat removal data. Although a decrease in heat transfer performance was observed for the device with lower surface area, CO 2 capture experiments performed with simulated flue gas and low-aqueous solvent demonstrated that both intensified devices lead to a similar improvement of 12 % in capture efficiency. This study provides an understanding on simplifying the intensified packing device geometry and decreasing the device fabrication cost by 25 % without compromising with the CO 2 absorption performance of the packed column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing Mixed Reality Tools to Support Mission Delivery at Hanford - 20520

Mission Support Alliance's (MSA) Public Works and Information Systems organizations have been working with Microsoft Corporation to develop and implement mixed reality operational solutions using their HoloLens technology. This collaborative effort is intended to drive innovative solutions and significantly improve MSA's efficiency in performing work at the Hanford Site. HoloLens, a mixed reality tool, is a commercial off-the-shelf technology that combines a head-mounted viewing screen with applications to help people and organizations learn, communicate, and collaborate more effectively through the use of mixed reality. https://microsoft.com/en-us/hololens MSA's initial pilot successfully demonstrated its ability to use mixed reality utilizing HoloLens' advanced features in a variety of ways, illustrating the potential efficiency gains previously stated as goals of this pilot. These achievements include the development of proprietary technology that allows synchronization between a HoloLens device and a mobile device or alternate global positioning system (GPS) device. This synchronization enables the HoloLens device to access real time GPS location data anywhere on the Hanford Site. This real time location data, combined with MSA's improved Hanford Geographical Information System (GIS) data, enables the mixed reality pilot application to identify underground utility systems as well as related utility attributes. This ability will aid utility workers in several areas, including excavation activities, the placement of large cranes, identifying interactions and conflicts with future underground utility placements and, eventually, recognizing and de-conflicting tank waste transfer system valve alignments. The HoloLens mixed reality application is also able to provide full or small scale holographic images of a facility's digital twin. This feature will allow MSA's Water and Sewer Utilities team to train and validate procedures associated with the new water treatment facility virtually, before it is constructed. This reduces the amount of time it takes to complete the training and procedure validation, and accelerates the overall construction schedule. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-atom implanted two-dimensional MOFs as efficient electrocatalysts for the oxygen evolution reaction

The exploration of novel electrochemical energy conversion and storage devices has been extensively studied in recent decades for their specific advantages. Therefore, the design of highly efficient, stable, and noble-metal-free electrocatalysts for oxygen-related reactions (OER) is critical but challenging and is still worth improving. Herein, a facile and controllable synthesis strategy for bimetallic electrocatalysts for the OER from a two-dimensional iron-based metal–organic framework (HUST-8, HUST = Huazhong University of Science and Technology) precursor has been reported. The unoccupied porphyrin center has been disposed into the layer structure of HUST-8, which is very facile for the introduction of a second type of metal center via post-modification treatment. Guided by the synthesis strategy, Fe/Ni, Fe/Co, Fe/Zn, Fe/Mn and Fe/Fe species have been fabricated, and their electrocatalytic performance for the OER has been further characterized, among which the Fe/Ni type exhibits the best efficiency and conversion. For Fe/Ni species of HUST-8 (labeled as Ni@HUST-8), in 1 M KOH, the initial potential for OER activity performance is 170 mV (vs. RHE). At 10 mA cm -2 , the corresponding overpotential is 240 mV and the Tafel slope is simulated as 60.8 mV dec -1 . All of these experimental results of Ni@HUST-8 illustrate its better performance than commercial IrO 2 . Compared to the MOF parent and other bimetallic species, the higher electrocatalytic performance of Ni@HUST-8 should be ascribed to the special synergistic effect of Fe and Ni centers, which tends to greatly improve the reaction kinetics and charge transfer efficiency, while increasing the activity of the OER and achieving the best catalytic performances. The systematic investigation clearly manifests the important role of the synergistic effect of bimetallic centers in the OER and provides other insight into fabricating tailored electrocatalysts derived from MOF-based templates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High Temperature (>700°C) Molten Salt Pump Technology for Generation 3 Solar Power Tower Systems

Bearings are required for long-shafted pumps historically used in concentrating solar thermal power applications. For molten chloride salts, bearings for such service conditions are not commercially available, nor has a design been demonstrated to work. Therefore, a project was sponsored by the Department of Energy’s Solar Energy Technologies Office for the development and demonstration of a submerged bearing for use in chloride salt pumps. This project’s tasks covered the tribological testing of candidate materials and the design, fabrication, testing, and post-test analysis of full-scale salt-compatible bearings. This work expands upon previous work. The effects of potential particulate in the salt were investigated through tribological bench testing. Through 11 tests, the MgO particulate size and concentration in a molten chloride salt were varied, and the effects on friction, wear rate, and wear characteristics were recorded. Novel journal bearings for chloride salt service were designed and fabricated based on these results. The bearings were of a relevant scale (i.e., for a 1.5 in. pump shaft) to demonstrate the technology with respect to further scale-up. The bearings were made of Haynes 244 and Yttria Partially Stabilized Zirconia. A custom bearing test rig, salt tanks, and associated infrastructure (e.g., heaters, tanks, transfer lines, gas flow control) were designed, procured, and installed. A few issues were encountered in the system fabrication process, resulting in delay of the project schedule. The system was successfully fabricated and assembled. Heating, cover gas, and pump motor systems were integrated into the control logic. This progress of the bearing test system represents a significant step forward towards demonstrating this promising technology. Nevertheless, the project ended before testing of the full-scale bearings could be performed.

14 SOLAR ENERGY↗

Solar Heat for Industrial Processes: Integration with Chemical Reactors

The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.

14 SOLAR ENERGY↗

Nickel-based superalloy single crystals fabricated via electron beam melting

Additive manufacturing technologies have emerged as potential disruptive processes whose possible impacts range from supply chain logistics, prototyping, and novel materials synthesis. Numerous works illustrate the ability to control mi- crostructure in fusion based processes and a few recent authors have even produced single crystals. However, a number of open questions remain regarding the process window which enables printing of single crystals. Furthermore, it has been observed that these additively manufactured single crystals exhibit a preferred $\langle$011$\rangle$ secondary orientation. In this work we investigate fabrication conditions which enable printing of single crystals via electron beam melting. A space filling design of experiments is utilized to efficiently explore the fabrication space. Single crystals were success- fully obtained using both commercially available powders and custom melt alloys. Microstructures obtained via these exploratory experiments exhibited a continuum of columnar structures ranging from weakly textured polycrystals, near single crystal, and fully single crystalline material. Complex geometry experiments are performed to study the grain selection mechanism. We find that the grain selection mechanism is independent of the bulk scale geometry and must therefore by driven by local heat transfer and solidification dynamics. Furthermore, grain selection is shown to be driven by competing driving forces; one which prefers epitaxial growth and another which is driven by the imposed scan pattern geometry. Finally, a mechanism is proposed for the anomalous secondary orientation preference.

36 MATERIALS SCIENCE↗

Oxygen Solubility in Aqueous Amine Solvents with Common Additives Used for CO 2 Chemical Absorption

Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.

60 APPLIED LIFE SCIENCES↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗