Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards

The objective of this work was to evaluate a set of standardized metrics proposed for characterizing a surface that has been scratched from a two-body abrasion test. This is achieved by defining a new abrasion region termed Zone of Interaction (ZOI). The ZOI describes the full surface profile of all peaks and valleys, rather than just measuring a scratch width as currently defined by the ASTM G 171 Standard. The ZOI has been found to be at least twice the size of a standard width measurement, in some cases considerably greater, indicating that at least half of the disturbed surface area would be neglected without this insight. The ZOI is used to calculate a more robust data set of volume measurements that can be used to computationally reconstruct a resultant profile for detailed analysis. Documenting additional changes to various surface roughness parameters also allows key material attributes of importance to ultimate design applications to be quantified, such as depth of penetration and final abraded surface roughness. Data are presented to show that different combinations of scratch tips and abraded materials can actually yield the same scratch width, but result in different volume displacement or removal measurements and therefore, the ZOI method is more discriminating than the ASTM method scratch width. Furthermore, by investigating the use of custom scratch tips for our specific needs, the usefulness of having an abrasion metric that can measure the displaced volume in this standardized manner, and not just by scratch width alone, is reinforced. This benefit is made apparent when a tip creates an intricate contour having multiple peaks and valleys within a single scratch. This work lays the foundation for updating scratch measurement standards to improve modeling and characterization of three-body abrasion test results.

Kobrick, Ryan L.↗

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Revisiting the blocking force test on ferroelectric ceramics using high energy x-ray diffraction

The blocking force test is a standard test to characterise the properties of piezoelectric actuators. The aim of this study is to understand the various contributions to the macroscopic behaviour observed during this experiment that involves the intrinsic piezoelectric effect, ferroelectric domain switching, and internal stress development. For this purpose, a high energy diffraction experiment is performed in-situ during a blocking force test on a tetragonal lead zirconate titanate (PZT) ceramic (Pb{sub 0.98}Ba{sub 0.01}(Zr{sub 0.51}Ti{sub 0.49}){sub 0.98}Nb{sub 0.02}O{sub 3}). It is shown that the usual macroscopic linear interpretation of the test can also be performed at the single crystal scale, allowing the identification of local apparent piezoelectric and elastic properties. It is also shown that despite this apparent linearity, the blocking force test involves significant non-linear behaviour mostly due to domain switching under electric field and stress. Although affecting a limited volume fraction of the material, domain switching is responsible for a large part of the macroscopic strain and explains the high level of inter- and intra-granular stresses observed during the course of the experiment. The study shows that if apparent piezoelectric and elastic properties can be identified for PZT single crystals from blocking stress curves, they may be very different from the actual properties of polycrystalline materials due to the multiplicity of the physical mechanisms involved. These apparent properties can be used for macroscopic modelling purposes but should be considered with caution if a local analysis is aimed at.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insitu Calibration of Quartz Crystal Microbalances

Computer models that predict the rate at which molecular contamination will deposit on optical surfaces typically use outgassing source terms, measured with quartz crystal microbalances, as a basis for the prediction. The American Society of Testing and Materials, Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials (Method E-1559), is probably the best know technique used by the aerospace community to measure the outgassing rates or source terms of materials. A simple method for the insitu calibration of quartz crystal microbalances, based on the heat of enthalphy of Adipic Acid, has been developed and demonstrated by the Marshall Space Flight Center, Environmental Effects Group. The calibration has been demonstrated over a sample temperature range of 25 to 66 degrees Celsius and deposition rates of 7 x 10 (exp -11) grams/cm(sup 2)-s and greater, for several measurement system configurations. This calibration technique is fully compatible with the American Society for Testing and Materials, Method E-1559, as well as other methodology. The calibration requires no modification of outgassing facilities employing an effusion cell and does not degrade the performance or function of typical vacuum systems.

Albyn, Keith↗

Fire Chemistry Testing of Spray-On Foam Insulation (SOFI)

An experimental study was initiated that included the long-term testing of the following SOFI materials, which make up the majority of the Thermal Protection System of the Shuttle External Tank: NCFI 24-124 (acreage foam) and BX-265 (close-out foam, including the intertank flange and bipod areas). A potential alternate material, NCFI 27-68 (acreage foam with flame retardant removed), was also tested. Fire chemistry testing was completed on samples that were retrieved after aging/weathering at intervals of 3, 6, and 12 months. The testing included three standard test methods: limiting oxygen index (ASTM G125), radiant panel (ASTM E162), and cone calorimeter (ASTM E1354).

Source record↗

Processing and Characterization of Basalt Fiber Reinforced Ceramic Composites for High Temperature Applications Using Polymer Precursors

The development of high temperature structural composite materials has been very limited due to the high cost of the materials and the processing needed. Ceramics can take much higher temperatures, but they are difficult to produce and form in bulk volumes. Polymer Derived Ceramics (PDCs) begin as a polymer matrix, allowing a shape to be formed, to be cured, and be pyrolized in order to obtain a ceramic with the associated thermal and mechanical properties. The two PDCs used in this development are polysiloxane and polycarbosilane. Polysiloxanes contain a silicon oxycarbide backbone when pyrolized up to 1000degC. Polycarbosilane, an organosilicon polymer, contain a silicon-carbon backbone; around 1200degC, -SiC begins to crystallize. The use of basalt in structural and high temperature applications has been under development for over 50 years, yet there has been little published research on the incorporation of basalt fibers as a reinforcement in composites. Basalt is a naturally occurring material found in volcanic rock. Continuous basalt fiber reinforced PDCs have been fabricated and tested for the applicability of this composite system as a high temperature structural composite material. Testing for this included thermal and mechanical testing per ASTM standard tests.

High Temperature Composites↗

A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

Czabaj, Michael W.↗

Crack Growth Testing of an Aluminum Oxynitride (AlON) for International Space Station Kick Panes

The mechanical properties of an aluminum oxynitride supplied as ground beams and disks were measured using ASTM International (formerly American Society for Testing and Materials) standard test methods. The slow crack growth tests were complicated by a "short" finish that increased strength scatter. Refining of the finish by more material removal in the second stage of grinding or the use of uniaxial grinding as specified in ASTM C1499 might have avoided the issue. The structural design parameters are an elastic modulus of E = 319 GPa, Poisson's ratio of v = 0.26, a fracture toughness of KIvb(A) = 2.18 MPa/m, slow crack growth (SCG) parameter n = 36, and SCG parameter A = 1.96 x 10-11 m/s.(MPa/m)n. For a ground finish, the Weibull parameters are a mean modulus of m = 14.0 and characteristic strength of sigma theta = 250.2 MPa. The 2015 vintage material exhibits similar mechanical properties to a 2010 vintage billet. Indentation flaws were not sensitive to the inherent crack growth mechanisms of this material and produced misleading results.

strength↗

Dry and wet arc track propagation resistance testing

The wet arc-propagation resistance test for wire insulation provides an assessment of the ability of an insulation to prevent damage in an electrical environment. Results of an arc-propagation test may vary slightly due to the method of arc initiation; therefore a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc by dripping salt water over pre-damaged wires which creates a conductive path between the wires. The power supply, test current, circuit resistances, and other variables are optimized for testing 20 guage wires. The use of other wire sizes may require modifications to the test variables. The dry arc-propagation resistance test for wire insulation also provides an assessment of the ability of an insulation to prevent damage in an electrical arc environment. In service, electrical arcs may originate form a variety of factors including insulation deterioration, faulty installation, and chafing. Here too, a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc with a vibrating blade. The test also evaluates the ability of the insulation to prevent further arc-propagation when the electrical arc is re-energized.

Beach, Rex↗

Static testing and proposed standard specifications

Static tests fall into two groups, the first of which is designed to load all members of the structure approximately in accordance with the worst loads which they carry in flight, while the second is directed to the testing of specific members which are suspected of weakness and which are difficult to analyze mathematically. The nature of the loading in the second type is different for every different test, but the purpose of the first is defined clearly enough to permit the adoption of some standard set of loading specifications, at least for airplanes of normal design. Here, an attempt is made to carry through an analysis leading to such a standard, the goal being the determination of a load which will simultaneously impose on every member of the airplane structure a stress equal to the worst it will carry in flight.

Warner, E P↗

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rugged Target Standards for HSI Remote Sensing

There is a need for stable test standards for many remote sensing applications that can be used both in the laboratory and in rugged test environments. Ideally these standards would be stable over time such that the same standard could be used from year to year for comparison of system performance. While ink-jet and spray gun methods can disperse controlled doses of dissolved analytes, methods to maintain particle size spectral variations are lacking. In addition, standards that are environmentally robust and stable over time are limited. As part of the recent Lighthouse work toward a Hyperspectral Imagery (HSI) proximal handheld sensor, Special Technologies Laboratory (STL) was tasked to do preliminary work toward a rugged, transportable, waterproof target board. This involved developing test standards using minerals of known particle sizes that have spectrally relevant features. Mineral powders were dispersed in binders that did not change their spectral characteristics. These standards were packaged such that they could be transported and used repeatedly. This paper discusses the methodology for developing this preliminary set of targets. Target sizes were limited to the proximal case, and further work is required to finalize the optimum binder and examine other possible appropriate minerals.

target standards, hyperspectral, minerals, analyte↗

Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards

Abrasion of mechanical components and fabrics by soil on Earth is typically minimized by the effects of atmosphere and water. Potentially abrasive particles lose sharp and pointed geometrical features through erosion. In environments where such erosion does not exist, such as the vacuum of the Moon, particles retain sharp geometries associated with fracturing of their parent particles by micrometeorite impacts. The relationship between hardness of the abrasive and that of the material being abraded is well understood, such that the abrasive ability of a material can be estimated as a function of the ratio of the hardness of the two interacting materials. Knowing the abrasive nature of an environment (abrasive)/construction material is crucial to designing durable equipment for use in such surroundings. The objective of this work was to evaluate a set of standardized metrics proposed for characterizing a surface that has been scratched from a two-body abrasion test. This is achieved by defining a new abrasion region termed Zone of Interaction (ZOI). The ZOI describes the full surface profile of all peaks and valleys, rather than just measuring a scratch width. The ZOI has been found to be at least twice the size of a standard width measurement; in some cases, considerably greater, indicating that at least half of the disturbed surface area would be neglected without this insight. The ZOI is used to calculate a more robust data set of volume measurements that can be used to computationally reconstruct a resultant profile for de tailed analysis. Documenting additional changes to various surface roughness par ameters also allows key material attributes of importance to ultimate design applications to be quantified, such as depth of penetration and final abraded surface roughness. Further - more, by investigating the use of custom scratch tips for specific needs, the usefulness of having an abrasion metric that can measure the displaced volume in this standardized manner, and not just by scratch width alone, is reinforced. This benefit is made apparent when a tip creates an intricate contour having multiple peaks and valleys within a single scratch. The current innovation consists of a software- driven method of quantitatively evaluating a scratch profile. The profile consists of measuring the topographical features of a scratch along the length of the scratch instead of the width at one location. The digitized profile data is then fed into software code, which evaluates enough metrics of the scratch to reproduce the scratch from the evaluated metrics. There are three key differences between the current art and this innovation. First, scratch width does not quantify how far from the center of the scratch damage occurs (ZOI). Second, scratch width does not discern between material displacement and material removal from the scratch. Finally, several scratches may have the same width but different zones of interactions, different displacements, and different material removals. The current innovation allows quantitative assessment of all three.

Street, Kenneth W., Jr.↗