Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal. Parameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermal Radiation Analyzer

Thermal Radiation Analyzer System TRASYS II solves radiation related aspects of thermal analysis problems. TRASYS II provides for calculation of internode radiation interchange data and for calculation of incident and absorbed heat rate data originating from environmental radiant heat sources. When TRASYS II used in conjunction with generalized thermal analysis program such as Systems Improved Numerical Differencing Analyzer (SINDA), any thermal problem expressed in terms of lumped parameter RC thermal network solved.

Vogt, R. A.↗

Thermal shock resistance of ceramic matrix composites

The experimental and analytical investigation of the thermal shock phenomena in ceramic matrix composites is detailed. The composite systems examined were oxide-based, consisting of an aluminosilicate matrix with either polycrystalline aluminosilicate or single crystal alumina fiber reinforcement. The program was divided into three technical tasks; baseline mechanical properties, thermal shock modeling, and thermal shock testing. The analytical investigation focused on the development of simple expressions for transient thermal stresses induced during thermal shock. The effect of various material parameters, including thermal conductivity, elastic modulus, and thermal expansion, were examined analytically for their effect on thermal shock performance. Using a simple maximum stress criteria for each constituent, it was observed that fiber fracture would occur only at the most extreme thermal shock conditions and that matrix fracture, splitting parallel to the reinforcing fiber, was to be expected for most practical cases. Thermal shock resistance for the two material systems was determined experimentally by subjecting plates to sudden changes in temperature on one surface while maintaining the opposite surface at a constant temperature. This temperature change was varied in severity (magnitude) and in number of shocks applied to a given sample. The results showed that for the most severe conditions examined that only surface matrix fracture was present with no observable fiber fracture. The impact of this damage on material performance was limited to the matrix dominated properties only. Specifically, compression strength was observed to decrease by as much as 50 percent from the measured baseline.

Carper, D. M.↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Effects of plasma spray parameters on two layer thermal barrier

The power level and the type of arc gas used during plasma spraying of a two layer thermal barrier system (TBS) were found to affect the life of the system. Life at 1095 C in a cyclic furnace test was improved by about 140 percent by increasing the power during plasma spray applications of the bond and thermal barrier coatings. This improvement is due to increases in the densities of the bond and thermal barrier coatings by 3 and 5 percent, respectively. These increases in densities are equivalent to about 45 and 30 percent reduction in mean porosities, respectively. The addition of hydrogen to the argon arc gas had the same effect as the reduction in power level and caused a reduction in TBS life.

Stecura, S.↗

Thermal Radiation Analyzer System

Thermal Radiation Analyzer System, TRASYS/II, is computer software system with generalized capability to solve radiation-related aspects of thermal-analysis problems. When used in conjunction with generalized thermalanalysis program, such as Systems Improved Numerical Differencing Analyzer (SINDA) program, any thermal problem expressed in terms of lumped-parameter RC thermal network solved.

Skladany, J.↗

Fast Measurements Of Thermal Diffusivities Of Ceramics

Temperature rises of samples compared with reference sample. Apparatus quickly measures thermal diffusivities of ceramics at high temperatures. Produces data on relative thermal diffusivities of as many as six ceramic specimens per hour. Thermal-diffusivity tester makes it easy to determine thermal diffusivities of ceramics. Pronounced effects of processing parameters on thermal properties of ceramics evaluated quickly.

Smith, Marnell↗

System overview on electromagnetic compensation for reflector antenna surface distortion

The system requirements and hardware implementation for electromagnetic compensation of antenna performance degradations due to thermal effects was investigated. Future commercial space communication antenna systems will utilize the 20/30 GHz frequency spectrum and support very narrow multiple beams (0.3 deg) over wide angle field of view (15-20 beamwidth). On the ground, portable and inexpensive very small aperture terminals (VSAT) for transmitting and receiving video, facsimile and data will be employed. These types of communication system puts a very stringent requirement on spacecraft antenna beam pointing stability (less than .01 deg), high gain (greater than 50 dB) and very lowside lobes (less than -25 dB). Thermal analysis performed on the advanced communication technology satellite (ACTS) has shown that the reflector surfaces, the mechanical supporting structures and metallic surfaces on the spacecraft body will distort due thermal effects from a varying solar flux. The antenna performance characteristics (e.g., pointing stability, gain, side lobe, etc.) will degrade due to thermal distortion in the reflector surface and supporting structures. Specifically, antenna RF radiation analysis has shown that pointing error is the most sensitive antenna performance parameter to thermal distortions. Other antenna parameters like peak gain, cross polarization level (beam isolation), and side lobe level will also degrade with thermal distortions. In order to restore pointing stability and in general antenna performance several compensation methods were proposed. In general these compensation methods can be classified as being either of mechanical or electromagnetic type. This paper will address only the later one. In this approach an adaptive phased array antenna feed is used to compensate for the antenna performance degradation. Extensive work has been devoted to demonstrate the feasibility of adaptive feed compensation on space communication antenna systems. This paper addresses the system requirements for such a system and identify candidate technologies (analog and digital) for possible hardware implementation.

Acosta, R. J.↗

Dynamic Pressure Drag on Rising Buoyant Thermals in a Neutrally Stable Environment

Abstract This study examines dynamic pressure drag on rising dry buoyant thermals. A theoretical expression for drag coefficient C d as a function of several other nondimensional parameters governing thermal dynamics is derived based on combining the thermal momentum budget with the similarity theory of Scorer. Using values for these nondimensional parameters from previous studies, the theory suggests drag on thermals is small relative to that on solid spheres in laminar or turbulent flow. Two sets of numerical simulations of thermals in an unstratified, neutrally stable environment using an LES configuration of the Cloud Model 1 (CM1) are analyzed. One set has a relatively low effective Reynolds number R e and the other has an order-of-magnitude-higher R e ; these produce laminar and turbulent resolved-scale flows, respectively. Consistent with the theoretical C d , the magnitude of drag is small in all simulations. However, whereas the laminar thermals have C d ≈ 0.01, the turbulent thermals have weakly negative drag ( C d ≈ −0.1). This difference is explained by the laminar thermals having near vertical symmetry but the turbulent thermals exhibiting considerable vertical asymmetry of their azimuthally averaged flows. In the laminar thermals, buoyancy rapidly becomes concentrated around the main centers of rotation located along the horizontal central axis, leading to expansion of thermals via baroclinic vorticity generation but doing little to break vertical symmetry of the flow. Vertical asymmetry of the azimuthally averaged flow of turbulent thermals is attributed mainly to small-scale resolved eddies that are concentrated in the upper part of the thermals.

Meteorology & Atmospheric Sciences↗

Efficient sensitivity analysis of the thermal profile in powder bed fusion of metals using hypercomplex automatic differentiation finite element method

Rapid cyclic temperature fluctuation occurring in powder bed fusion of metals using a laser beam (PBF-LB/M) influences the formation of flaws in printed parts. Consequently, there is a pressing need to enhance the quality of printed parts by developing innovative methodologies that can predict thermal histories and help uncover the intricate relationships between process parameters and thermal profiles. Sensitivity Analysis (SA) emerges as an essential tool for this, offering the potential for process optimization and enhanced quality control. Nonetheless, conventional SA methodologies often incur in excessive computational costs and potential numerical approximation errors. Here, to address this technical challenge, we present a novel method for SA that integrates the HYPercomplex-based Automatic Differentiation (HYPAD) technique with transient thermal simulations conducted via the finite element method (FEM). Leveraging this methodology, we efficiently and accurately perform SA for PBF-LB/M processes in a post-processing step. Compared to traditional methods like Finite Differences (FD), HYPAD-FEM required 96 % less computational time for obtaining sensitivities for 22 process parameters, under a comparative study conducted within the context of the 2018–02 AM benchmark of the National Institute of Standards and Technology. In summary, HYPAD-FEM offers superior efficiency and accuracy in SA over conventional methods, delivering the best sensitivity of a model without the need for step-size selection and problem or parameter-based implementations.

36 MATERIALS SCIENCE↗

Generation of localized reactor point kinetics parameters using coupled neutronic and thermal fluid models for pebble-bed reactor transient analysis

The systems analysis of anticipated operating occurrences and design basis accidents for pebble-bed reactor systems requires knowledge of neutron point kinetics equations (PKE) parameters. Typically, the generation of PKE parameters is performed in a global manner using standalone neutronics calculations, without the inclusion of thermal fluid distributions. We utilize Griffin and Pronghorn for generating global and local PKE parameters which includes the use of thermal fluid distributions to account for localized effects. This work establishes a methodology for calculating PKE parameters for a pebble bed reactor with a coupled neutronics/thermal fluids analysis. PKE parameters generated on a global and local basis are compared against a diffusion solve for a typical load-following transient. Locally-generated neutron kinetic parameters are able to reduce the maximum error in the transient power level from 5% to below 1.5%; along with this, bulk temperature errors were reduced from 12 K to 4 K.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of SCALE and MELCOR for a generic pebble bed fluoride high-temperature reactor

This paper presents the development and application of SCALE and MELCOR models for a fluoride salt-cooled high-temperature reactor (FHR) based on publicly available specifications. SCALE version 6.3beta15 was used to generate power distributions and decay heat curves, and MELCOR version 2.2.18019 was used to calculate the thermal hydraulic response of an assumed FHR primary system. Here, an approach was developed for determining the equilibrium state of the core using depletion of a core slice model and blending of fuel compositions at different burnups to provide three-dimensional fuel composition in the core. Results compared between a core with entirely fresh fuel and one with an equilibrium fuel composition revealed that the equilibrium core led to lower steady-state temperatures but slower cooldown during a loss of flow accident (LOFA). A sensitivity study was then conducted to explore the transient response of our FHR system to variations in thermal hydraulic parameters of the system using the equilibrium core. The inlet temperature, graphite thermal conductivity, and SCRAM time all provided significant control over peak fuel and coolant temperatures. Uncertainties in radionuclide decay data in SCALE were used to perform a decay heat sensitivity study, and we found that uncertainties in decay heat led to negligible impact on peak temperatures during the course of the transient. In all cases evaluated, the observed peak fuel temperatures remained approximately 700 K below anticipated failure limits for the LOFA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Space Shuttle Orbiter flight heating rate measurement sensitivity to thermal protection system uncertainties

A study was completed to determine the sensitivity of computed convective heating rates to uncertainties in the thermal protection system thermal model. Those parameters considered were: density, thermal conductivity, and specific heat of both the reusable surface insulation and its coating; coating thickness and emittance; and temperature measurement uncertainty. The assessment used a modified version of the computer program to calculate heating rates from temperature time histories. The original version of the program solves the direct one dimensional heating problem and this modified version of The program is set up to solve the inverse problem. The modified program was used in thermocouple data reduction for shuttle flight data. Both nominal thermal models and altered thermal models were used to determine the necessity for accurate knowledge of thermal protection system's material thermal properties. For many thermal properties, the sensitivity (inaccuracies created in the calculation of convective heating rate by an altered property) was very low.

Bradley, P. F.↗

Measurement from satellites of land surface parameters and fluxes in the thermal infrared bands: Problems and methods

The main problems arising in the elaboration of accurate and reliable algorithms for extracting land surface parameters and flux from their measured radiances are discussed. Methods of solution in the thermal infrared spectral domain are described. Particular interest is given to the inversion of thermal models and to the problems resulting from the heterogeneity of the observed surfaces.

Becker, F.↗