Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

The mechanics of nucleation and growth and the surface tensions of active matter

Homogeneous nucleation, a textbook transition path for phase transitions, is typically understood on thermodynamic grounds through the prism of classical nucleation theory. However, recent studies have suggested the applicability of classical nucleation theory to systems far from equilibrium. Here, in this article, we formulate a purely mechanical perspective of homogeneous nucleation and growth, elucidating the criteria for the properties of a critical nucleus without appealing to equilibrium notions. Applying this theory to active fluids undergoing motility-induced phase separation, we find that nucleation proceeds in a qualitatively similar fashion to equilibrium systems, with concepts such as the Gibbs–Thomson effect and nucleation barriers remaining valid. We further demonstrate that the recovery of such concepts allows us to extend classical theories of nucleation rates and coarsening dynamics to active systems upon using the mechanically derived definitions of the nucleation barrier and surface tensions. Three distinct surface tensions—the mechanical, capillary, and Ostwald tensions—play a central role in our theory. While these three surface tensions are identical in equilibrium, our work highlights the distinctive role of each tension in the stability of active interfaces and the nucleation and growth of motility-induced phases.

Capillary waves↗

Measurements of the electron energy distribution function in partially magnetized low temperature plasmas

While Langmuir probes (LPs) are relatively simple and inexpensive plasma diagnostics for the electron density, temperature, and the electron energy distribution function (EEDF), the interpretation of the measured current–voltage (I–V) characteristic is complicated considerably by the presence of a magnetic field. In regimes where the electron gyroradius is comparable to the probe radius, the electron flux to the probe surface is retarded by reduced mobility across field lines and can no longer be described by a thermal model. Predicting the current collected by the probe in these regimes requires accurate estimates of the plasma diffusion coefficients, which are usually difficult to obtain. In this work, we measure electron energy distribution functions in E×B plasmas with magnetized electrons and non-magnetized ions in argon and krypton gases, using both a LP and laser Thomson scattering (LTS) at various magnetic fields. Using the LTS measurements to provide a robust benchmark for comparison, we compare existing theories describing the flux to the probe under magnetized conditions. We find that even when the electron gyroradius associated with the effective electron temperature is small compared to the probe radius, the EEDF computed using classical probe theory is still robust at energies higher than the energy at which the gyroradius becomes larger than the probe size. For plasmas that are not strongly non-Maxwellian, we formulate a method to extract robust density and temperature measurements using physics-informed fitting techniques to analyze EEDFs computed using classical theory.

Devin, E. G. [Princeton Plasma Physics Laboratory ↗

Multiphasic size-dependent growth dynamics of nanoparticle ensembles

Colloidal nanoparticles are of great interest in modern science and industry. However, the thermodynamic mechanism and dynamics of nanoparticle growth have yet to be understood. Addressing these issues, we tracked hundreds of in-situ growth trajectories of a nanoparticle ensemble using liquid-phase TEM and found that the nanoparticle growth, including coalescence, exhibits nanoparticle size-dependent multiphasic dynamics, unexplainable by current theories. Motivated by this finding, we developed a model and theory for an ensemble of growing nanoparticles, providing a unified, quantitative understanding of the time-dependent mean and fluctuation of nanoparticle size and size-dependent growth rate profiles across various nanoparticle systems and experimental conditions. Our work reveals that the chemical potential in a small nanoparticle strongly deviates from the Gibbs-Thomson equation, shedding light on how it governs the size-dependent growth dynamics of nanoparticles.

Kim, Ji-Hyun↗

High resolution measurements of core density collapse dynamics in LHD

The core density collapse (CDC) is an abrupt instability that degrades the performance of super dense core stellarator plasmas on the Large Helical Device (LHD). In LHD, CDCs have proved to be an operational limit in so-called outward-shifted configurations. New measurements with high time resolution Thomson scattering characterize dynamics of the instability in the core. The density profile is observed to collapse inwards, narrowing the density peak till the core itself collapses. A hot, radially localized feature is also observed in the electron temperature profile during the collapse and disappears within a few hundred microseconds of CDC onset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Post-puff SOL broadening on MAST-U under high-recycling conditions: evidence consistent with cross-field transport changes

Transient broadening of the scrape-off layer (SOL) density profile can modify main-chamber first-wall particle fluxes and divertor loading, yet its control parameters remain debated between divertor-regime transitions, neutral dynamics and changes in cross-field transport. We investigate fueling-driven SOL density-profile evolution and post-fueling relaxation on MAST-Upgrade (MAST-U) in ohmic L-mode, using two otherwise similar double-null Conventional Divertor discharges (I p = 450 kA, B T = 0.33 T) with identical 50 ms low-field side gas puffs; the only intentional difference is the puff start time. Upstream Thomson scattering shows that both discharges develop a transient far-SOL density profile modification, expressed as an increased SOL-width metric λ n e and a far-SOL enhancement consistent with a shoulder-like signature. In the earlier-puff case, the SOL-width metric remains elevated after puff termination and the post-puff decay time scales are systematically longer across the analysed radii. Outer-target Langmuir probes indicate high-recycling conditions during the analysed window (few-eV T e with radially peaked j sat,∥ and q ∥ profiles, without signatures of deep detachment). The outer-divertor collisionality proxy Λ div is elevated in both cases and does not discriminate between the different post-puff persistence. The target-integrated ion flux proxy ∫ J sat dA evolves nearly identically in both discharges when aligned to the puff start. Taken together, these observations suggest that the late/post-puff upstream SOL evolution is not set by parallel exhaust to the outer targetalone and is more consistent with upstream cross-field redistribution, with a possible role for plasma–neutral coupling and fueling geometry.

MAST-U↗

Neutrino and pair creation in reconnection-powered coronae of accreting black holes

A ubiquitous feature of accreting black hole systems is their hard X-ray emission which is thought to be produced through Comptonization of soft photons by electrons and positrons in the vicinity of the black hole, in a region with optical depth of order unity. The origin and composition of this Comptonizing region, known as the corona, is a matter open for debate. In this paper we investigate the role of relativistic protons accelerated in black-hole magnetospheric current sheets for the pair enrichment and neutrino emission of AGN coronae. Our model has two free parameters, namely the proton plasma magnetization σ p , which controls the peak energy of the neutrino spectrum, and the Eddington ratio λ X,Edd (defined as the ratio between X-ray luminosity L X and Eddington luminosity L Edd ), which controls the amount of energy transferred to secondary particles. For sources with λ X,Edd ≳ λ Edd,crit (where λ Edd,crit ∼ 10 -1 for σ p = 10 5 or ∼ 10 -2 for σ p = 10 7 ), proton-photon interactions and γγ annihilation produce enough secondary pairs to achieve Thomson optical depths τ T ∼ 0.1-10. In the opposite case of λ X,Edd ≲ λ Edd,crit , the coronal pairs cannot originate only from hadronic interactions. Additionally, we find that the neutrino luminosity scales as L 2 X /L Edd for λ X,Edd ≲ λ Edd,crit , while it is proportional to L X for higher λ X,Edd values. We apply our model to four Seyfert galaxies, including NGC 1068, and discuss our results in light of recent IceCube observations.

active galactic nuclei↗

Effect of detachment on Magnum-PSI ELM-like pulses: direct observations and qualitative results

Abstract Conditions similar to those at the end of the divertor leg in a tokamak were replicated in the linear plasma machine Magnum-PSI. The neutral pressure in the target chamber is then increased to cause the target to transition from an attached to a detached state. Superimposed to this steady state regime, edge localised mode (ELM)-like pulses are reproduced, resulting in a sudden increase in plasma temperature and density, such that the heat flux increases transiently by half an order of magnitude. Visible light emission, target thermography, and Thomson scattering are used to demonstrate that the higher the neutral pressure the more energy is removed from the ELM-like pulse in the volume. If the neutral pressure is sufficiently high, the ELM-like pulse can be prevented from affecting the target and the plasma energy is fully dissipated in the volume instead (ID 4 in table 1). The visible light images allow the division of the ELM-plasma interaction process of ELM energy dissipation into 3 ‘stages’ ranging from no dissipation to full dissipation (the target plasma is detached). In the second publication related to this study, spectroscopic data is analysed with a Bayesian approach, to acquire insights into the significance of molecular processes in dissipating the plasma energy and particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of confinement regime boundaries via separatrix parameters on Alcator C-Mod based on a model for interchange-drift-Alfvén turbulence

The separatrix operational space (SepOS) model (Eich and Manz 2021 Nucl. Fusion 61 086017) is shown to predict the L–H transition, the L-mode density limit, and the ideal magnetohydrodynamic ballooning limit in terms of separatrix parameters for a wide range of Alcator C-Mod plasmas. The model is tested using Thomson scattering measurements across a wide range of operating conditions on C-Mod, spanning $\overline{n}_{\mathrm{e}}$ = 0.3–5.5 $\times 10^{20}\,$m −3 , $B_{\mathrm{t}} = 2.5$–8.0 T, and $B_{\mathrm{p}}$= 0.1–1.2 T. An empirical regression for the electron pressure gradient scale length, $\lambda_{{p}_{\mathrm{e}}}$, against a turbulence control parameter, $\alpha_{\mathrm{t}}$, and the poloidal fluid gyroradius, $\rho_{\mathrm{s,p}}$, is constructed for H-modes and found to require positive exponents for both regression parameters, indicating turbulence widening of near-scrape-off layer widths at high $\alpha_{\mathrm{t}}$ and an inverse scaling with $B_{\mathrm{p}}$, consistent with results on ASDEX Upgrade. The SepOS model is also tested in the unfavorable drift direction and found to apply well to all three boundaries, including the L–H transition as long as a correction to the Reynolds energy transfer term, $\alpha_\mathrm{RS} \lt 1$ is applied. I-modes typically exist in the unfavorable drift direction for values of $\alpha_{\mathrm{t}} \lesssim 0.3$. Finally, an experiment studying the transition between the Type-I ELMy and EDA H-mode is analyzed using the same framework. It is found that a recently identified boundary $\alpha_{\mathrm{t}} = 0.55$ at excludes most EDA H-modes but that the balance of wavenumbers responsible for the L-mode density limit, namely $k_\mathrm{EM} = k_\mathrm{RBM}$, may better describe the transition on C-Mod. The ensemble of boundaries validated and explored is then applied to project regime access and limit avoidance for the SPARC primary reference discharge parameters.

ELM suppression↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Towards fully predictive gyrokinetic full- f simulations: validation and triangularity studies in TCV

Designing economical magnetic confinement fusion power plants motivates computational tools that can estimate plasma behavior from engineering parameters without direct reliance on experimental measurement of the plasma profiles. In this work, we present full-f global long-wavelength gyrokinetic simulations of edge and scrape-off layer turbulence in tokamaks that use only magnetic geometry, heating power, and particle inventory as inputs. Unlike many modeling approaches that employ free parameters fitted to experimental data, raising uncertainties when extrapolating to reactor scales. This approach directly simulates turbulence and resulting profiles through gyrokinetics without such empirical adjustments. This is achieved via an adaptive sourcing algorithm in Gkeyll that strictly controls energy injection and emulates particle sourcing due to neutral recycling. We show that the simulated kinetic profiles compare reasonably well with Thomson scattering and Langmuir probe data for Tokamak á Configuration Variable (TCV) discharge #65125, and that the simulations reproduce characteristic features such as blob transport and self-organized electric fields. Applying the same framework to study triangularity effects suggests mechanisms contributing to the improved confinement reported for negative triangularity (NT). Simulations of TCV discharges #65125 and #65130 indicate that NT increases the E x B flow shear (by about 20% in these cases), which correlates with reduced turbulent losses and a modest change in the distribution of power exhaust to the vessel wall. While the physical models contain approximations that can be refined in future work, the predictive capability demonstrated here, evolving multiple profile relaxation times with kinetic electron and ion models in hundreds of GPU hours, indicates the feasibility of using Gkeyll to support design studies of fusion devices.

Hoffmann, Antoine Cyril David [Princeton Plasma Ph↗

Recent advances in plasma control and physics research in the Large Helical Device

The Large Helical Device (LHD), the largest superconducting helical system in the world, is equipped with advanced heating and diagnostic tools, facilitating plasma control and physics research. Data assimilation was employed for electron temperature control using a real-time Thomson scattering system and real time prediction code. A virtual LHD environment enabled visualization of escaping high-energy tritium ions and demonstrated that these ions impact the rear side of the divertor plate. Pioneering results crucial to plasma control have also been achieved. Real-time wall conditioning using Lithium granule dropping improved bulk ion energy and particle transport while simultaneously enhancing the heavy impurity transport. Progress has also been made in the investigation of turbulence-driven transport. At the confinement bifurcation, ion-scale turbulence decreased, while electron-scale turbulence increased. A change in the anisotropy of turbulent eddies was also observed at the confinement bifurcation. Coexistence of local and non-local turbulence was identified in electron-scale turbulence. Non-local turbulence exhibited the rapid spatial propagation of perturbations throughout the plasma, while local turbulence followed the temperature gradient. A transition between drift-wave turbulence and magnetohydrodynamics (MHD) turbulence was observed with the turbulence minimized at the transition condition. Machine learning analysis was employed to evaluate the temperate and density conditions of this turbulence transition. Then, real-time control of fueling and heating was applied to maintain the turbulence transition condition, improving the energy confinement enhancement factor by 20%. In addition, evidence was obtained for collisionless ion heating by energetic-ion-driven geodesic acoustic modes and MHD bursts. These achievements represent unique contributions to the development of fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of outer divertor leg detachment on the high field side scrape-off layer in DIII-D and ASDEX Upgrade

In this work, evidence is presented that detachment of the outer divertor leg leads to a reduction of electron density and neutral pressure in the high-field side (HFS) scrape-off layer (SOL) of the ASDEX Upgrade (AUG) and DIII-D tokamaks with ion $B$ x $∇B$ drift directed toward the X-point (favorable configuration). These results are observed across multiple diagnostics and without the use of impurity seeding to reach detachment. In AUG, outer divertor leg detachment correlates with a decrease in electron density near the separatrix at the inner midplane, measured with HFS reflectometry. A concurrent reduction in inner divertor density and neutral pressure at the inner target is observed using divertor Thomson scattering and neutral pressure gauges. These effects are present in both L- and H-mode plasmas. In DIII-D, a similar reduction is detected through analysis of line-integrated hydrogenic emission measured by multiple diagnostics in the HFS SOL close to the separatrix. The consistent trends in both devices indicate that high electron density and strong hydrogenic emissivity in the HFS SOL are common features of H-mode plasmas in the favorable configuration, independent of wall material and divertor geometry. In L-mode plasmas, the reduction in electron density and neutral pressure is not observed in DIII-D, possibly due to differences in wall material. These results emphasize the importance of the divertor state in determining the two-dimensional neutral distribution and edge fueling.

detachment↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Dynamical structure factors of warm dense matter from time-dependent orbital-free and mixed-stochastic-deterministic density functional theory

Abstract We present the first calculations of the inelastic part of the dynamical structure factor (DSF) for warm dense matter (WDM) using time-dependent orbital-free density functional theory (TD-OF-DFT) and mixed-stochastic-deterministic (mixed) Kohn Sham TD-DFT (KS TD-DFT). WDM is an intermediate phase of matter found in planetary cores and laser-driven experiments, where the accurate calculation of the DSF is critical for interpreting x-ray Thomson scattering measurements. Traditional TD-DFT methods, while highly accurate, are computationally expensive, motivating the exploration of TD-OF-DFT and mixed TD-KS-DFT as more efficient alternatives. We applied these methods to experimentally measured WDM systems, including solid-density aluminum and beryllium, compressed beryllium, and carbon–hydrogen mixtures. Our results show that TD-OF-DFT requires a dynamical kinetic energy potential in order to qualitatively capture the plasmon response. Additionally, it struggles with capturing bound electron contributions. In contrast, mixed TD-KS-DFT offers greater accuracy in distinguishing bound and free electron effects, aligning well with experimental data, though at a higher computational cost. This study highlights the trade-offs between computational efficiency and accuracy, demonstrating that TD-OF-DFT remains a valuable tool for rapid scans of parameter space, while mixed TD-KS-DFT should be preferred for high-fidelity simulations. Our findings provide insight into the future development of DFT methods for WDM and suggest potential improvements for TD-OF-DFT.

36 MATERIALS SCIENCE↗

Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums

By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. Finally, these experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗