Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient photoconductive terahertz detection through photon trapping in plasmonic nanocavities

We present a photoconductive terahertz detector that employs a plasmonic nanocavity to offer high-sensitivity and broadband operation when used in a terahertz time-domain spectroscopy system even at very low optical pump power levels. By employing a plasmonic nanocavity, all of the photocarriers are generated within a 100 nm distance from the photoconductor contact electrodes, enabling a short transport time for almost all of the photogenerated carriers. As a result, the photoconductive detector maintains high quantum efficiency and ultrafast operation simultaneously, enabling high-sensitivity and broadband operation at very low optical pump power levels. We utilize a photoconductive detector based on a plasmonic nanocavity optimized for operation at a 770 nm optical wavelength in a terahertz time-domain spectroscopy system and demonstrate a 100 dB signal-to-noise ratio and a 0.1–6 THz noise-equivalent bandwidth at a record-low average optical pump power of 0.1 mW, compared to the state-of-the-art photoconductive terahertz detectors. The extremely low optical power budget of the demonstrated photoconductive detector makes this detector attractive for multi-pixel terahertz imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of laser ablation of silicon as a function of pulse length at constant fluence via time-resolved x-ray spectroscopy

We investigate the ablation of silicon as a function of laser pulse length at a constant fluence using time-resolved x-ray spectroscopy data obtained from OMEGA EP experiments at the University of Rochester's Laboratory for Laser Energetics. Our targets consisted of three-layer planar structures composed of Si (50 μm), Cu (25 μm), and SiO 2 (500 μm) layers. The Si layer was irradiated by a 351-nm laser with varying pulse widths of 250 ps, 500 ps, 1 ns, and 10 ns while maintaining a constant fluence of ~27.9 kJ/cm 2 . Electron temperatures and densities of the ablated plasma were determined by analyzing the time-resolved x-ray spectroscopy data through a comparison of experimental measurements with synthetic results obtained from Si atomic calculations in a steady state and non-local thermodynamic equilibrium. These calculations were computed using PrismSPECT. Additionally, radiation-hydrodynamics simulations with FLASH are used to generate simulated plasma-density and plasma-temperature profiles, which are then compared with the experimental measurements. Our analyses reveal that increasing the laser pulse length at a constant fluence results in a decrease in electron temperatures and densities. Furthermore, the longer pulses with lower intensities lead to deeper ablation regions before reaching the peak ablation but lower ionization balances in the silicon layer. Furthermore, these findings emphasize the critical role of laser pulse length in plasma ablation and shock generation for laser-impulse studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution time- and angle-resolved photoemission spectroscopy with 11 eV laser pulses

Performing time- and angle-resolved photoemission (tr-ARPES) spectroscopy at high momenta necessitates extreme ultraviolet laser pulses, which are typically produced via high harmonic generation (HHG). Despite current advances, HHG-based setups still require large pulse energies (from hundreds of μ J to mJ) and their energy resolution is limited to tens of meV. Here, we present a novel 11 eV tr-ARPES setup that generates a flux of 5 × 10 10 photons/s and achieves an unprecedented energy resolution of 16 meV. It can be operated at high repetition rates (up to 250 kHz) while using input pulse energies down to 3 µ J. We demonstrate these unique capabilities by simultaneously capturing the energy and momentum resolved dynamics in two well-separated momentum space regions of a charge density wave material ErTe 3 . This novel setup provides the opportunity to study the non-equilibrium band structure of solids with exceptional energy and time resolutions at high repetition rates.

47 OTHER INSTRUMENTATION↗

Time-Resolved Grazing Incidence X-Ray Absorption Spectroscopy for the In Situ Investigation of the Initial Stages of Sputter-Deposited Copper Thin Films

The sputter deposition and the growth of thin copper films on float glass substrates are in situ studied using grazing incidence, reflection mode X-ray absorption fine structure spectroscopy with subsecond time resolution. The experimental data are compared with model calculations, assuming the presence of crystalline, face-centered cubic metallic Cu nanostructures. From a detailed analysis of the measured spectra, the film thickness as well as the surface roughness is determined, leading to a detailed understanding of the films growth as a function of the sputter deposition time. In particular, different stages of film growth can clearly be distinguished from the fits of the experimental data. The results suggest the formation of isolated, approximately nm-sized copper clusters in the initial phase of the film deposition for the first few seconds, a coalescence phase with a nominal thickness of ≈1.5–2.8 nm, constant roughness of about 1.4 nm for the subsequent ≈5 s, and finally 3D growth of the Cu crystallites in the film for later stages of film growth. Further prospects of the methodology are given.

36 MATERIALS SCIENCE↗

High mass resolution, high angular acceptance time-of-flight mass spectroscopy for planetary missions under the Planetary Instrument Definition and Development Program (PIDDP)

This final report covers three years and several phases of work in which instrumentation for the Planetary Instrument Definition and Development Program (PIDDP) were successfully developed. There were two main thrusts to this research: (1) to develop and test methods for electrostatically scanning detector field-of-views, and (2) to improve the mass resolution of plasma mass spectrometers to M/delta M approximately 25, their field-of-view (FOV) to 360 degrees, and their E-range to cover approximately 1 eV to 50 keV. Prototypes of two different approaches to electrostatic scanning were built and tested. The Isochronous time-of-flight (TOF) and the linear electric field 3D TOF devices were examined.

Young, David T.↗

Oxidative Deboronation of Boronic Acids by Hydrogen Peroxide in Planta Generates Borate for Cross-Linking of Rhamnogalacturonan II

Vascular plants require boron to cross-link the rhamnogalacturonan-II (RG-II) domain of pectin to form functional cell walls. Boronic acids, which form reversible esters with cis-diols like borate, have been proposed to influence RG-II cross-linking, though the mechanism remains unclear. We used suspension-cultured rose cells adapted to grow without boron to investigate the effect of boronic acids on RG-II dimerization. When grown with phenylboronic acid (PBA) as the sole boron source, nearly all RG-II was crosslinked, whereas methylboronic acid (MBA) only partially restored cross-linking. In contrast, in vitro assays showed that homogeneous RG-II monomers did not dimerize with alkyl or aryl boronic acids unless supplemented with hydrogen peroxide (H2O2), which oxidatively converts boronic acids to boric acid. Real-time NMR spectroscopy and density functional theory calculations provided insight into the reaction mechanism and energetics of oxidation respectively. Together, our data show that exogenous boronic acids are a source of boric acid for plants, and that the deboronation reaction generates aryl or alkyl alcohol byproducts that can undergo further chemical modification in planta. The fate and potential roles of these byproducts in planta remain to be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared absorption spectroscopy of dynamically compressed water

Streaked visible spectroscopy is well established in dynamic compression research. Infrared measurements remain problematic, however, due to the diminishing sensitivity of streak camera photocathodes beyond 800 nm. Time-stretch techniques offer an alternative method for probing infrared features during single-event experiments. This paper discusses the development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breaking Simple Scaling Relations through Metal–Oxide Interactions: Understanding Room-Temperature Activation of Methane on M/CeO 2 (M = Pt, Ni, or Co) Interfaces

The clean activation of methane at low temperatures remains an eminent challenge and a field of competitive research. In particular, on late transition metal surfaces such as Pt(111) or Ni(111), higher temperatures are necessary to activate the hydrocarbon molecule, but a massive deposition of carbon makes the metal surface useless for catalytic activity. However, on very low-loaded M/CeO 2 (M = Pt, Ni, or Co) surfaces, the dissociation of methane occurs at room temperature, which is unexpected considering simple linear scaling relationships. This intriguing phenomenon has been studied using a combination of experimental techniques (ambient-pressure X-ray photoelectron spectroscopy, time-resolved X-ray diffraction, and X-ray absorption spectroscopy) and density functional theory-based calculations. The experimental and theoretical studies show that the size and morphology of the supported nanoparticles together with strong metal–support interactions are behind the deviations from the scaling relations. These findings point toward a possible strategy for circumventing scaling relations, producing active and stable catalysts that can be employed for methane activation and conversion.

03 NATURAL GAS↗